Speaker
Description
To enhance safety, an emergency heat removal system (EHRS) is provided as a part of the reactor plant. One of the main elements of this system is an air heat exchanger (AHX), equipped with a device for air flowrate control with passive opening principle, which is a gate.
To ensure operability of this gate, high-temperature experimental test facility was developed and manufactured. This test facility permits to test the gate under operation conditions similar to the standard ones (temperature higher than 500°C).
A gate prototype is installed on a special box (3000 × 3000 mm) located on the site.
For uniform heating of air in the gate box equipped with an electric heating system of 170 kW electric power; and a special slot gap with optimum space provided by a spacing system is made.
To arrange flowrate, cold air supply and hot air discharge, air duct paths with required valves and a blower (fan) were designed. Because of the high temperature, the air circuit was unclosed; air duct outlet with special flare emission beyond the bounds of the building was arranged.
High-temperature thermal insulation is used at the test facility to ensure safe operation.
An information-and-measuring system was designed for on-line reporting on test facility parameters (temperature, pressure, flowrate, etc.).
Considering large overall dimensions and a high-altitude location of the test facility, special process tooling was developed in the course of test facility construction.
A process was developed and process tooling was manufactured to provide the slot gap in the course of manufacture.
A process was developed to simplify thermal insulation installation.
Now, the gate is tested at the made experimental test facility.
Speaker's title | Mr |
---|---|
Speaker's email address | frolova@okbm.nnov.ru |
Country/Int. organization | Russian Federation |
Affiliation/Organization | JSC “Afrikantov OKBM” |