Since 18 of December 2019 conferences.iaea.org uses Nucleus credentials. Visit our help pages for information on how to Register and Sign-in using Nucleus.

19–22 Apr 2022
Vienna, Austria
Europe/Vienna timezone
FR22 starts in Vienna 19 - 22 April 2022 Online Stream: https://event.do/iaea/a/#/events/5048

Assay of Waste drum based on Passive Neutron Counting Technique

21 Apr 2022, 13:40
2h
Vienna, Austria

Vienna, Austria

POSTER Track 3. Fuels, Fuel Cycles and Waste Management Poster Session

Speaker

Dr Sivakumar P

Description

Characterization of alpha emitting nuclide and other fission products in the radioactive waste generated in reprocessing plants is a regulatory requirement for their disposal. The assay of plutonium in the solid radioactive wastes could be carried out either using gamma spectrometry or neutron counting, depending mainly on the surface dose of the container. Presence of large amount of fission products renders the use of gamma spectrometry inappropriate due to the increased background radiation. In order facilitate the detection of plutonium in such instances, a passive neutron based assaying system for alpha bearing solid wastes has been designed and developed. The detector system has been fabricated in a semi-circular shape to assay the alpha bearing solid wastes in a 200 L capacity SS drum. This detector employs eight numbers of 3He neutron detectors embedded in High Density Poly Ethylene (HDPE). All the detectors were identical with an active length of 900 mm and a diameter of 50 mm filled with a gaseous mixture of 75% 3He and 25% Kr at 3 bar pressure. For deploying this system in an environment with reasonably high beta gamma background radiation, 25 mm lead shield in front of the detector was used.

Studies reveal that, the rotation of the drum during the assay improves the accuracy of the results. However, only rotation by supplementary angles was found to yield results with minimum error which was found to be in the range of ± 20%. Hence two measurements at 180º apart were found to be sufficient for satisfactory assay. This system was calibrated with plutonium source typically handled in fast reactor fuel reprocessing facilities. The minimum detection limit of typical of research reactor grade plutonium has been estimated to be 35 mg with a 99.9 % confidence level for the back ground prevailing in the site. It has been determined that a gamma radiation background of up to 5 mSv/h could be tolerated without loss of accuracy.

Speaker's title Mr
Speaker's email address psk@igcar.gov.in
Country/Int. organization India
Affiliation/Organization DAE, IGCAR

Primary author

Co-authors

Mr Vijayan K S Mr Santhosh Kumar Dr Govindan P (RpG, IGCAR, Kalpakkam, India) Dr Subba Rao R V (RpG, IGCAR, Kalpakkam, India) Ananthasivan Krishnamurthy (IGCAR, DAE)

Presentation materials

There are no materials yet.

Peer reviewing

Paper