Development of a new confocal-macro X-ray fluorescence spectrometer built on 3D printer

5 Nov 2018, 16:55
5m
M Building (Vienna International Centre)

M Building

Vienna International Centre

Wedge Participant Leveraging technological advancements for safeguards applications (TEC) [TEC] Recent Examples of Innovation in Safeguards

Speaker

Dr Imre Szalóki (Institute of Nuclear Techniques, Budapest University of Technology and Economics)

Description

For 3D analysis of elementary composition on surface and depth layers of objects with non-regular spatial shape a new type of confocal macro XRF (CM-XRF) spectrometer was designed and built. A simply constructed 3D printer was applied as the moving system for the basic devices of the XRF spectrometer. The SD detector and the low-power air-cooled X-ray tube (4W) mounted on a vertically moving console and the sample is fixed on x-y stage of the 3D printer that translates it in horizontal directions within 20 cm lengths. For both excitation and secondary X-ray beams were planned a new collimator system on the basis of Monte Carlo simulation, performed by MCNP6 software package, in order to create a macro confocal measuring set-up. The minimum step-size is 100 μm and the spatial precision of the positioning of each mechanical stages (x-y-z) of the 3D mechanical structure is about 5 μm. The minimum of the achieved diameter of the focal spot of the confocal measuring arrangement was found as 480 μm using aluminum tubes as collimator. The measuring confocal spot at the cross junction of the excitation and secondary fluorescence X-ray beams is positioned on the sample surface by application two laser beams and a built-in digital microscope. The positioning optical system together with the MC-XRF spectrometer are fixed on the horizontal arm of the 3D printer that is moved in vertical direction. The elements of XRF and optical positioning systems are mounted on additional mechanical moving stages for fine manual setting the confocal geometrical set-up. The analytical capability and geometrical resolution of the MC-XRF spectrometer were determined in x-y-z directions and the MC-XRF spectrometer was tested with some analytical application. Acknowledgments This work has been carried out in the frame of OAH-ABA-23/15-M, OAH-ABA-14/16-M projects supported by Hungarian Atomic Energy Authority and VKSZ-14-1-2015-0021 Hungarian project supported by the National Research, Development and Innovation Found.
Topics NEW1
Which "Key Question" does your Abstract address? NEW1.3

Primary author

Dr Imre Szalóki (Institute of Nuclear Techniques, Budapest University of Technology and Economics)

Co-authors

Ms Anita Gerenyi (Institute of Nuclear Techniques, Budapest Universití of Technology and Economics) Mr Gábor Radócz (Budapest University of Technology and Economics, Institute of Nuclear Techniques)

Presentation materials

There are no materials yet.