Conveners
B07: Radiotracers for Energy of the Future II
- Quang Nguyen Huu
- TSec Patrick Brisset
Mr
Zahir IDIRI
(Centre de Recherche Nucleaire d'Alger, 02 Bd Frantz Fanon, BP399, Alger-Gare, Algeria)
25/04/2017, 16:30
RADIATION TECHNOLOGIES FOR MEASUREMENT
Oral
A neutron back scattering set-up for analysis of hydrogenous sample materials has been simulated using MCNP5 neutron and photon transport code. The set-up is mainly composed of an Am-Be neutron source of 37.2GBq and a He-3 neutron gas detector which are embedded in polyethylene bloc, the latter acting as a reflector. The modelisation used in the simulation was validated comparing thermal...
Mr
Sung-Hee Jung
(Korea Atomic Energy Research Institute, Korea, Republic of)
25/04/2017, 16:45
RADIATION TECHNOLOGIES FOR MEASUREMENT
Oral
Radiotracer techniques have been widely applied in various fields of industry in order to diagnose plant processes during operation. This is possible because radioisotopes can selectively label certain process media and represent their movements. Recently, radioisotopes have been successfully used as tracers in the investigations for clarifiers and digesters in wastewater treatment plants....
Mr
Abbas Sultan
(Chemical Engineering and Biochemical Engineering Department Missouri University of Science and Technology, Rolla, MO 65409-1230. United States of America)
25/04/2017, 17:00
RADIATION TECHNOLOGIES FOR MEASUREMENT
Oral
Linear attenuation coefficient distribution, time-averaged cross-sectional gas holdup distribution, and their radial profiles have been measured in 6'' (152 mm) Plexiglas bubble columns with and without internals for the air -water system at a superficial gas velocity 45 cm/s by utilizing a gamma-ray computed tomography (CT) technique. 1" (25.5 mm) diameter Plexiglas internals covers 25% of...
Mr
Rachad ALAMI
(National Center of Energy Science and Nuclear Techniques, Morocco)
25/04/2017, 17:15
RADIATION TECHNOLOGIES FOR MEASUREMENT
Oral
In distilation column, the packed column for gas-liquid contacting are used extensively for absorption, stripping and distillation operations. One of principal troubleshooting encountered in the operation packed bed is the coke disposition which is related process condition and structural problems. As the gamma scanning technique is an adequate to define on-line troubleshooting, in the...
Mr
Shantanu Roy
(Indian Institute of Technology - Delhi, India)
25/04/2017, 17:30
RADIATION TECHNOLOGIES FOR MEASUREMENT
Oral
Utilization of noninvasive radiation based techniques has become widespread in several industrial applications. Of particular importance is its deployment in systems involving two or more phases. Such systems are ubiquitously found in areas concerning from the processing of fuels and chemicals to the production of feed, food, pharmaceuticals, and specialty materials. In spite of extensive...
Mr
Vaibhav Khane
(Chemical Engineering and Biochemical Engineering Department Missouri University of Science and Technology, Rolla, MO 65409-1230. United States of America)
25/04/2017, 17:45
RADIATION TECHNOLOGIES FOR MEASUREMENT
Oral
The pebble bed modular reactor (PBMR) is a type of 4th generation nuclear reactor. In a pebble bed reactor, nuclear fuel is in the form of spherical pebble and moves slowly inside the core of the reactor under the influence of gravity. A coolant gas moves through the voids formed in between the pebbles and removes fission heat generated from the nuclear fuel. Multiphase Reactors and...