Since 18 of December 2019 conferences.iaea.org uses Nucleus credentials. Visit our help pages for information on how to Register and Sign-in using Nucleus.

International Conference on Applications of Radiation Science and Technology

Europe/Vienna
IAEA Board Room B/M1 (IAEA Headquarters)

IAEA Board Room B/M1

IAEA Headquarters

Vienna, Austria
Description
The saga of the radiation sciences goes back to the astonishing discoveries by Röntgen and the Curies at the turn of the twentieth century. Driven initially by the quest to comprehend the complex effects of radiation fields on chemical processes, radiation chemistry, in particular, has emerged as a valuable tool for understanding the intricate chemical reactions of importance to a variety of disciplines. It has also found wide-ranging commercial applications in such areas as materials processing, health care, food and agriculture. While the development of ultrafast techniques such as pulse radiolysis has allowed for the exploration of important chemical processes, the simultaneous technological development of high intensity gamma radiation sources and high powered electron beam accelerators has assured the radiation sciences’ on going tryst with industry, leading to the successful commercial utilization of many of the applications developed by scientists and researchers. The International Atomic Energy Agency (IAEA), working in close partnership with its Member States as well as with professional scientific bodies and the industry, has striven to maximize the contribution of radiation sciences and technologies towards the achievement of the Member States’ development priorities in a safe manner.

While acknowledging the many innovations and accomplishments achieved in the field of radiation sciences so far, it is now time to take a comprehensive look at their status in academia and industry in the years ahead and their ability to meet the challenges of contemporary times. Radiation scientists are currently engaged in addressing issues related to producing advanced high performance materials through ‘green’ industrial processes ensuring cleaner environment, attaining a thorough understanding of the chemical effects of radiation under extreme conditions (which is important for extending the lifetime of present nuclear reactors, making their fuel cycles safer and secure to operate), and overcoming impediments regarding the transportation and storage of waste materials (which requires novel approaches to address the complicated chemistry at interfaces). Radiation technologists on the other hand are faced with such tremendous challenges as ensuring the safe and reliable operation of large radiation facilities, implementing requisite international standards for process control, ensuring the continued supply and transport of large cobalt-60 consignments across continents, and developing a new generation of high power electron beam accelerators and X-ray sources for emerging applications. Besides radiation processing applications, there are other radiation technologies such as the use of radiotracers to improve and optimize the performance of industrial processes, as well as to study environmental processes, and the use of nucleonic measurement systems to control the quality of products.

The first IAEA International Conference on Applications of Radiation Science and Technology (ICARST-2017) will provide a unique opportunity to review the key developments in the applications of radiation science and technology as well as the ‘state of the science’ in this field as well as revising national, regional and global initiatives for implementing proven industrial applications that lead to socio-economic benefits and strengthen capacity building in Member States. ICARST -2017 also aims to serve as a composite platform through which industry and academia can foster new initiatives for ensuring the success of radiation technologies in meeting the emerging challenges in various areas.
Form for Submission of a Paper (Form B)
Grant Application Form (Form C)
Participation Form (Form A)
    • Registration Vienna International Centre (M Building)

      Vienna International Centre

      M Building

    • OP: Opening Ceremony IAEA Board Room B/M1

      IAEA Board Room B/M1

      • 1
        Opening Remarks
        Speaker: Mr Yukiya Amano (IAEA Director General)
      • 2
        Welcome by DDG-NA
        Speaker: Mr Aldo Malavasi (IAEA)
      • 3
        Welcome by DDG-TC
        Speaker: Mr Dazhu Yang (IAEA)
      • 4
        Ionizing Radiation - Innovative and Effective Tool for Science and Industry
        Ionizing radiations in the form of gamma rays, energetic electrons and X-rays (Bremsstrahlung) are being used for many practical applications. Successful irradiation processes provide significant advantages in comparison to typical thermal and chemical processes, such as higher throughput rates, reduced energy consumption, less environmental pollution, more precise process control and products with superior qualities. Ionizing radiation can modify the physical, chemical and biological properties of materials on an industrial scale. Many gamma sources and electron accelerators were built and installed for these purposes over the past fifty years and the field is still expanding. The biggest industrial use of ionizing radiation is the modification of polymer properties in a variety of industrial applications such as wire and cable insulation, tire manufacturing, production of polymeric foams, hydrogels and heat-shrinkable films and tubing, curing of coatings, adhesives and composites. Ionizing radiation became a perfect tool for formation and synthesis of nanoparticles and nanocomposites. Sterilization by ionizing radiation accounts for the preparation of approximately 50% of single use medical devices in UK and 40–50% of all disposable medical products in North America. Radiation technologies may also be applied to environmental protection and cultural heritage preservation. Efficient radiation technologies for gas, liquid and solid wastes treatment were developed to reduce environmental degradation. Cultural heritage artefacts based on paper, textiles or wood are prone to biological attack and their disinfection using ionizing radiation has been successfully demonstrated. Another field of applications is based on ionizing radiation penetration properties and its precise detection, through utilization of open and sealed radiation sources. Optimization of industrial processes is essential not only for efficient, safe and sustainable operation, but also to save materials, energy, protect the environment and reduce plant shutdown time. Complex industrial processes include environmentally related processes (such as harbours and dams, oil fields and ore/coal mines) so it is essential to have suitable means to investigate them for process optimization and trouble-shooting – preferably without shutting down the plant/process. Radiotracers and sealed source techniques are best-suited methods to address these problems. Nuclear techniques in most of the cases provide on-line investigations without shutting down the plant/process. Automation and improvements in instrumentation and hardware, such as tracer injection systems, detectors and data acquisition systems are developed for safer and reliable application. All applications are based on science developed in universities and research centres and then transferred to industry to be used in a safe and proper manner. It is a joint input of scientists and professionals working in the field to the main UN Millennium Goals of achieving a resource-efficient and climate-change-resilient economy and society, protecting and sustainably managing natural resources and ecosystems, and ensuring a sustainable supply and use of raw materials and other environmental resources. This universal humanistic role of science was articulated by Madame Curie, a lady born exactly 150 years ago in Warsaw as Maria Skłodowska. She developed a new innovative and effective tool – ionizing radiation, which broke new ground in physics and chemistry opening the door for advances in engineering, biology and medicine.
        Speaker: Mr Andrzej Chmielewski (Institute of Nuclear Chemistry and Technology, Poland)
    • 11:00
      Coffee break
    • 13:15
      Lunch break
    • A02: Advanced Polymeric Materials IAEA Board Room B/M1

      IAEA Board Room B/M1

      Conveners: Ms Celina Horak (CNEA), TSec Agnes Safrany
      • 16
        Past, Present and Near Future of Radiation Processing of Polymers
        Past, present and near future of radiation processing of polymers Olgun Güven Hacettepe University Department of Chemistry Beytepe, 06800, Ankara, Turkey www.polymer.hacettepe.edu.tr In the early years of radiation processing, radiation-induced crosslinking of polymers and radiation sterilization of medical products have developed into substantial industries. Radiation processing of polymers in its widest sense is the application of radiochemical effects of ionizing radiations (Gamma rays, X-rays, Accelerated electrons and Swift heavy ions) on polymers and plastics on industrial scale. When polymers are irradiated with high energy radiation the ultimate effects are observed as crosslinking and/or scissioning of main or side chains, grafting, curing and formation of oxidized products. Among the established industrial applications of radiation processing of polymers; crosslinking of insulation of cables and wires, preparation of heat-shrinkables, polymer foams, automotive parts, tyres, water distribution pipes, tubes, plastic medical devices, hydrogel burn and wound dressings, composites, controlled degradation of teflon and marine-based cellulosics can be mentioned. The field of lignocellulosic fiber-polymer composites utilizing radiation technology in their formulation is re-emerging[1]. The applications mentioned above are based on radiation-induced control of structure formation in polymers on macroscopic scale, with the growing interest on development of nanomaterials based on polymers however, the unique role and power of ionizing radiation in nanostructuring have been rediscovered. Nanostructure formation by using ionizing radiation encompass a wide range of products namely, nanocomposites, nanogels, metallic nanoclusters, surface grafting at nanoscale, functionalization of track-etched membranes, molecular imprinting. This review will highlight chronologically the milestones of radiation processing of polymers in bulk, radiation-grafted materials for separation and purification[2], for energy conversion and energy storage[3] and health-care applications. Established and emerging applications of radiation technology for nanotechnology will be elaborated with a future outlook. [1] O. Güven, S.N. Monterio, E.A.B. Moura, J.W. Drelich, “Re-emerging field of lignocellulosic fiber-polymer composites and Ionizing Radiation Technology in their formulation” Polymer Reviews, xx(2016)xxx. [2] M.M. Nasef, O. Güven, “Radiation-grafted copolymers for separation and purification purposes: Status, challanges and future directions” Prog. Polym. Scien., 37(2012)1597-1606. [3] M.M. Nasef, S.A. Gürsel, D. Karabelli, O. Güven, “Radiation-grafted materials for energy storage and energy conversion applications” Prog. Polym. Scien., xx(2016)xxx.
        Speaker: Mr Olgun Güven (Hacettepe University, Ankara, Turkey)
      • 17
        Radiation Curing by Cross-Linking Polymerization of Multifunctional Monomers: a Comparison Between Free Radical and Cationic Mechanisms
        Radiation-curing by polymerization of multifunctional monomers is a well-established technology in the field of coatings and adhesives as well as in the graphic arts. UV-visible light and high energy radiation are alternative activation processes exhibiting their specific scope, advantages, and limitations depending on the application. The situation is quite different when the industrial goal is to cure thick and large parts of composites reinforced by fillers or by fibrous materials that induce opacity with respect to UV visible light. High energy radiation processing has been identified since decades a promising method for performing out-of-autoclave curing, with several advantages in terms of processing time, energy consumption, environmental footprint and sanitary concerns. The challenging objective of developing the EB/X-ray curing technology for high performance composite materials drives the needs of the advanced knowledge and understanding of reactivity - structure - properties inter-relations. Our paper will focus on the nanostructural features of radiation-cured networks. The radiation-induced polymerization of multi-acrylate monomer compositions is known to proceed heterogeneously at various dimension scales, depending of monomer composition. In radiation-cured materials based on a single type of monomer, the network were shown to display heterogeneities of cross-link densities resulting from a complex interplay between mechanistic and kinetic factors along the solidification process. Compared to free-radical chain polymerization, radiation-initiated cationic polymerization exhibits peculiarities at the different steps of the chain process (complex initiation and propagation mechanisms, pseudo-living character …). The influence of these features on the reactivity and on the microstructure of multifunctional aromatic epoxy monomers and of their acrylate analogs has been examined using various types of radiation (UV, visible, EB, X-ray). Complementary spectroscopic and analytical methods were implemented in order to correlate the changes of network physical properties with the progress of polymerization. AFM analysis of the networks in the topographic, phase contrast and indentation modes provides quite informative data with indications on the actual dimensions of the soft and rigid domains, and of their evolution, as the curing level is driven to higher values. Solid-state proton T2 NMR relaxation experiments were also performed on radiation-cured materials with valuable quantitative information on the local mobility in the nanoheterogeneous samples as well as on the associated fraction of material, as polymerization proceeds. On the basis of these observations and measurements, a consistent scenario for the build-up of radiation-cured networks is proposed for both types of polymerization mechanisms. The influence of this general behavior is discussed in the perspective of elaborating materials with demanding use properties.
        Speaker: Mr Xavier Coqueret (Universite de Reims Champagne Ardenne, France)
      • 18
        Use of Irradiation, for the Development of Active Edible Coatings, Beads and Packaging to Assure Food Safety and to Prolong the Preservation.
        There is a need to develop active packaging and active edible coating by using natural ingredients. To reduce the pollution problems caused by synthetic and non-biodegradable packaging films, biodegradable packaging materials are encouraged to be developed especially in case of antimicrobial packaging. Also, the consumer demand to replace synthetic antimicrobial by natural compounds is rising. However, natural antimicrobials are not stable and should be encapsulated or immobilized in polymers to preserve their bioactivity and to assure a control release of the active compounds during time. Edible polymers should possess the appropriate barrier and chemical properties and should retain its properties during commercial marketing of foods. Proteins and polysaccharides have been used to develop edible coatings, beads and biodegradable films. However, these polymers are soluble in water and their functional properties should be improved. This presentation will focus on the use of crosslinking and functionalization of polymers by gamma irradiation for the development of active edible coating, beads and packaging and the use of gamma irradiation in combination with these active polymers to assure food safety.
        Speaker: Ms Monique Lacroix (INRS-Institut Armand-Frappier, Canadian Irradiatin Centre, Canada)
      • 19
        Radiation Grafted Antimicrobial Film for Advanced Active Packaging Application
        Low density polyethylene (LDPE) film was grafted with sorbic acid (SA) using radiation induced grafting (RIG) technique to develop advanced antimicrobial grafted film for active packaging application. Instead of mixing antimicrobial additive as food additive directly with food, this additive was incorporated in films via RIG and allow the functional effect at the food surface, whereby the microbial growth is mostly found. Therefore, removal or reduction of preservatives from food formulate with non-migrate additives increases food safety and meet consumer demands for fresher food. The evidences of sorbic acid (SA) grafting film were studied using Grazing-angle Fourier Transform Infra-red Spectroscopy (GA-FTIR), Field Emission Scanning Electron Microscope (FESEM), Atomic Force Microscopy (AFM) and X-Ray Photoelectron Spectroscopy (XPS). The antimicrobial properties of LDPE film functionalized by sorbic acid were evaluated with respect of its mechanical properties and suface properties. The analysis of fungi killing time during storage of freshly baked bread packed in grafted shows a significant antimicrobial efficacy on food indicating the potential of grafting of this active agent on a LDPE film instead of adding it in the food itself.
        Speaker: Mr Zulkafli Ghazali (Malaysian Nucelar Agency (Nuklear Malaysia), Malaysia)
      • 20
        Radiation Mediated Bioactive Compounds Immobilization on Polymers to Obtain Multifunctional Food Packaging Materials
        Background: Irradiation of polymeric surface is a versatile way to implement specific functionalities which further can react with bioactive compounds in order to confer to materials antimicrobial, antioxidant and biological functions absolutely necessary to protect, prolong self life of food products and make them beneficial for health. Methodology: Both undegradable and degradable polymers were exposed in optima conditions to gamma-rays or cold plasma in various atmospheres (air, oxygen, nitrogen) and oxygen and nitrogen - containing groups were reacted with chitosan, vitamin E and C and vegetable oils with high therapeutic value encapsulated in nanostructures obtained by co-axial electrospinning or emulsion techniques. The nanoencapsulation of active (antimicrobial and antioxidant) vegetable oils into chitosan matrix by leads to a significant decrease of Total Viable Counts when compared with the PLA substrate plasma pre-treated and surface modified only with chitosan.Bioactive layer was covalently linked onto polymeric substrate so it is stable, compounds do not migrate in food products and bulk properties of base materials are not changed. Results: Bioactive multifunctional polyethylene based food packaging with antimicrobial activity against both gram positive and gram negative bacteria and antioxidant activities have been obtained. Use of chitosan/vegetable oils shows synergistic activities. Other two biodegradable substrates as polylactic acid and cellulosic materials (cellulose/chitin blends and kraft papers) were undergone to the same procedures with very promising results moreover these are easily recyclable and integrate into environment after use. Assessment of degradation of materials was investigated by enzymatic degradation in presence of Phanerochaete chrysosporium by biochemical investigation (superoxide dismutase activity in fungi mycelium samples, content of malondialdehyde, catalase enzyme, extracellular protein), changes in average molecular weight, ATR-FTIR and AFM. The plasma and gamma radiation exposed PLA and PLA/CHT stratified composites supported fungal growth resulting in their degradation, which is reflected in change in polymeric substrate structure. The presence of bioaccessible material, i.e., PLA and chitosan, facilitated degradation. The plasma and gamma irradiated PLA samples show increased degradation. Natural and synthetic polymeric substrates, plasma activated and /or gamma-irradiated,were tested as active-food packaging to improve the shelf-life of the poultry meat, fresh beef meet, fresh curd cheese and apple juice. Rosehip seeds oil was found to impart the best antioxidant and antimicrobial properties. Conclusion: By comparison of gamma-rays or cold plasma exposure it can conclude that gamma-irradiation is more efficient in terms of bioactive functions of obtained materials.
        Speaker: Ms Cornelia Vasile (P.Poni Institute of Macromolecular Chemistry, Romania)
      • 21
        Radiation Processing of Natural and Synthetic Polymers for Potential Applications
        El-Sayed A. Hegazy , Hassan A. Abd El-Rehim National Center for Radiation Research and Technology, Egyptian Atomic Energy Authority, P.O.Box 29, Nasr City, Cairo 11371, Egypt. Abstract: The effect of ionizing radiations on the cross-linking and degradation of some natural polymers such as CMC-Na, chitosan, carrageenan, alginates and starch was investigated. Trials were made to control and reduce the irradiation dose required for the CMC-Na degradation by the addition of some additives and controlling the irradiation conditions. The possibility to cross-link CMC-Na/PAAm and starch/PAAm blends using electron beam irradiation to obtain good adsorbent materials of unique properties for possible practical uses were also investigated. The end product of irradiated natural products such as carboxy-methylcellulose, chitosan and Na-alginate may be used as food additive or benefited in agricultural purposes. From an economic point of view these doses are not accepted, it was significantly reduced by the addition of APS, KPS and H$_2$O$_2$. The addition of such additives to chitosan or Na-alginate during irradiation process accelerates their degradation. Degraded Na-alginate and chitosan could be used as growth promoter for plants in agriculture purposes. The growth and other responses of Zea maze and bean plants that treated with irradiated Na-alginate or chitosan of different Mw’s were investigated. The test field results showed that the treatment of the zea plant with irradiated Na-alginate or chitosan enhanced the plant growth and increases its productivity. Chemically cross-linked, pH-sensitive PVP/PAAc hydrogel nanoparticles were successfully prepared in a high yield via $\gamma$-radiation-induced polymerization of acrylic acid in aqueous solution of poly(vinylpyrrolidone) (PVP) as a template polymer. The particle sizes of the PVP/PAAc nanogels at different pH values were evaluated using dynamic light scattering (DLS) and the morphology was assessed using atomic force microscopy (AFM) and transmission electron microscopy (TEM). Smaller and more stable nanogel particles can be produced by irradiating a feed solution of $50$–$75$ mol% AAc and using PVP of high molecular weight. Factors affecting size and encapsulation efficiency were optimized to obtain nanogel sufficient to entrap drug efficiently. The use of PVP/PAAc nanogels prepared at different compositions and irradiation doses was evaluated for dry eye syndrome application.
        Speaker: Mr ElSayed Hegazy (Atomic Energy Authority, Egypt)
    • B02: Education, Training and Safety Conference Room M2

      Conference Room M2

      Conveners: TSec Patrick Brisset, Mr Thorsten Bruno Otto Jentsch (German)
      • 22
        A New Approach to Teach to Beginners How to Analyze Tracing Results by a Rapid Visual Method
        When people learn how to analyze the results of Residence Time Distribution (RTD) experiments, it is very difficult to them to immediately be able to have a pertinent idea of the kind of mixing only by looking at the RTD curve; the difficulty remaining in the understanding of the effects of flows in the system (in parallel and/or series, recirculation…) on the global RTD curve. Every people need a long experience to be able to do that (several months and even years). However this period can be significantly reduced. To do this, we developed a new visual method to start to learn RTD complementing the classical method (theory about the residence time, transfer function, simple systems like CSTR or Plug flow reactor). We use the software DTS®. The students use it in an unusual way, to do simulations of reactors associations from the simplest to the very complex. We tested the method along a several years period with students preparing a master of engineering degree, and we progressively improved the different reactors configurations, so that the teaching efficiency was the best. Now, in only one or two hours, the students testing a dozen of selected configurations can gain several months of experience.
        Speaker: Mr Olivier Potier (Université de Lorraine - CNRS, France)
      • 23
        Education Training: INSTN Designated as an IAEA Collaborating Centre
        The National Institute for Nuclear Science and Technology (INSTN) created in 1956 by the French Government has been designated as an IAEA Collaborating Centre in May 2016. This recognition allows the Agency to receive support from this Institute to implement its programs of which those from the Department of Nuclear Sciences and Applications. The perimeter of this collaborating centre is "Education and Training in nuclear technologies industrial and radiopharmaceutical applications". The INSTN and the Agency have defined a work plan to host specific training courses, or to develop new training courses in connection with INSTN's areas of expertise. Thus at the end of June 2017, a three weeks training course on "Training and certification for industrial applications of radiation technologies: radiotracers Residence Time Distribution approach and sealed sources column scanning technique" will be organized in Saclay, near Paris. Through column scanning equipment dedicated to training, innovative training methods, practical room for manipulating radiotracer, theoretical contributions will be delivered by experts from the Agency and practical work will be carried out by participants consisting of both fellows of the Agency but also professionals from the host country. This training will benefit from the infrastructure and logistics of the INSTN for the safe use of radionuclides used for tracing. The INSTN as a part of the French Atomic Energy Commission (CEA), is under the joint supervision of three ministries: Ministry of National Education, Higher Education and Research, Ministry of the Economy, Industry and the Digital Sector, and Ministry of Ecology, Sustainable Development and Energy. The Institute has partnerships with various universities and higher education institutions in France and abroad but also with technical schools for academic degree from operator to PhD diploma, mostly in the nuclear domain. The Institute organises tailor-made professional training courses in France or abroad and support Continuing Professional Development so as to increase staff skills in a large spectrum of nuclear activities such as: nuclear engineering and applications, detection and measurements of radiations; radiation protection, chemistry and radiochemistry; Nuclear medicine, radiopharmacy, medical physics, radiotherapy and molecular imaging; new technologies for energy, economics of energies; micro and nanotechnologies. In the field of academic and vocational training, INSTN also signed another agreement with the IAEA in 2014 which helped to launch the project of Virtual Reactor Laboratory (Internet Reactor Laboratory) which will allow students from European universities a remote access, via the Internet, to the ISIS research reactor (nominal power of 700 kW). These students can monitor, through a video system (via Internet), the operation of the ISIS reactor by exchanging with a trainer-operator present in the control room of the installation of the CEA-Saclay. For 60 years, the INSTN is a key-player in France for Education & training in nuclear domains such as industry, research and medical. Being designated Collaborating Centre will strengthen connections that INSTN has with the IAEA.
        Speaker: Mr Paul LIVOLSI (CEA - INSTN, France)
      • 24
        Training and Certification in Radiotracers and Sealed Sources Industrial Applications
        The International Society of Tracer sand Radiation Applications (ISTRA) has been created in 2015 with his HQ in Vienna as the federation of Tracers and Radiation Application teams in the world with about 500 members today. IAEA activities regarding capacity building are mainly conducted within TC projects through fellowships, scientific visits and expert missions. It has been clearly seen that there is a lack of structure in these trainings. FE hosts, RTC organizers experts are doing their best providing a good work but they do what and how they wish, think and can. It is also quite difficult to synchronise the event with real field work to allow practical experience for the trainees. We have to fix these issues and for that, in collaboration with IAEA, ISTRA has developed syllabuses, e-learning modules and Question Banks on Radiotracers applications (RTD approach – TCS 31, 38 and 49), Sealed sources applications (column scanning, NBS – TCS in publication process), Tracers and NCS applications in sediment transport (TCS 59). The global objective is to create a training and certification system for practitioners, ISTRA acting as examination and certification body worldwide. The system has 3 levels of qualification, similar to the NDT system, based on the recognized syllabuses and examination: - Level 1: helper/assistant - Level 2: autonomous practitioner - Level 3: team leader Beside the better structure of the courses and the associated examination, it is also helping the practitioners and teams in promotion of the technologies, by improving the visibility and recognition of the qualification of personnel. Today approx. 50 practitioners have been trained, qualified and certified in Africa and Latin America and the Caribbean regions. Unfortunately, due to the lack of TC projects, nobody in Europe and Asia-Pacific regions.
        Speaker: Mr Patrick Brisset (Internationa Atomic Energy Agency, (IAEA), Vienna, Austria)
      • 25
        The IAEA Methodology for Radiological Protection of the Environment, Including Human and Non-Human Biota
        In 2005 the IAEA started to work with international organizations and Member States towards enhancing international standards and guidance for the control of radiological impacts to people and the environment. Until then, protection of the environment was based on the assumption that compliance with standards for human protection would ensure that other species are not put at risk; this assumption was being challenged by the international community. IAEA standards considering a new perspective were started in 2006 with the Fundamental Safety Principles and continued with the IAEA Basic Safety Standards on Radiation Protection and the Safety of Radiation Sources. In these standards, the radiation protection objectives for non-human species were related to higher organization levels as populations, communities and ecosystems, rather than on the protection of individuals as it is the case for humans; the need to consider protection of humans and other species in an integrated manner was also recognized. The IAEA followed the 2007 recommendations of the ICRP on protection of the environment, and proposed an assessment methodology for flora and fauna similar to that applied for demonstrating compliance of doses to humans with predefined criteria. The method entails the use of a set of reference animals and plants (RAPs) that relates to various species and ecosystems. Radiation exposure levels can be estimated and compared to criteria identified, below which no or only very limited adverse effects to biota are expected. The integration of the protection of humans and other species was approached by assuming the linkage of the exposure scenarios between humans and flora and fauna. This resulted in a practical methodology which can be implemented with basically the same resources as those used to demonstrate protection of humans; the effectiveness of the approach to protect flora and fauna is verifiable by environmental monitoring programmes similar to those already in place for the humans exposures pathways, considering the relevant media. The IAEA established different ways to consider protection of biota for different exposure situations. For planned exposure situations, the results of the estimation of exposures to RAPs are compared to reference levels, and this could imply the need of control of the source. For existing and emergency situations, the control of those exposures is limited or impossible and the results of the assessments should be considered as an aspect in the optimization process, together with others, like social and economic factors. The paper presents the methodology developed by the IAEA and its implementation in international legal instruments, like in the Convention on the Prevention of Marine Pollution by Dumping of Wastes and Other Matter and the OSPAR Convention for the Protection of the Marine Environment of the North-East Atlantic, and in recently prepared IAEA Safety Guides.
        Speaker: Mr Diego Telleria (IAEA)
      • 26
        Radiation Sciences and Applications Program in Arab countries
        The AAEA works since 1989 to enhance the socio-economical development in Arab countries by promoting the peaceful applications of atomic energy in many aspects of life. The AAEA is implementing “The Arab Strategy for Peaceful use of Atomic Energy up to 2020”, which focusses on: the introduction of nuclear science in educational institutions; the use of nuclear technologies to improve plant and animal production; food and radiation processing methods; the use of nuclear technology in the diagnosis and treatment of diseases; the use of nuclear techniques in water resources management; the integration of the production of radioactive isotopes among Arab countries; the use of EB accelerators in irradiation operations and processing materials; the use of ion accelerators in the field of analysis and properties improvement and strengthening and promoting of the Arab capabilities in the field of NDT. Under the framework of the above topics, AAEA has implemented many training courses, workshops, experts meetings, expert missions, scientific visits, conferences and seminars which will be detailed in the presentation. For the implementation of the activities, AAEA is using country infrastructure such as: research reactors (RRs) that can produce radioisotopes (Egypt–2, Algeria–2, Libya–1, Morocco–1, Syria–1, Jordan–1); ion accelerator (cyclotron) for the production of radioisotopes such as PET (Morocco, Algeria, Syria, Saudi Arabia, Egypt); ion accelerator (VDG) for material researches and analysis (Egypt, Syria, Jordan, Lebanon, Algeria); electron accelerator (LINAC) for research and industrial applications (Tunis, Egypt, Syria, Morocco, Saudi Arabia, Algeria, UAE, Kuwait); electron accelerator (LINAC) for nuclear medicine radiotherapy (all Arab countries) and $\gamma$-irradiators ($\gamma$-ray) for medical applications and others (all Arab countries).
        Speaker: Mr Abdelmajid MAHJOUB (Tunisia)
      • 27
        Quality Management in Radiotracer Technology and Sealed Source Applications
        Radiotracer and sealed source applications technology for industrial processes have become important non-destructive and non-invasive tools for on-line diagnosis of process malfunctioning, optimization and predictive maintenance. The technologies have been developed and established in many countries and are used by others as a routine service activity for preventive maintenance of process columns and tanks in their local industries. The demand for the technology has found to be steadily increasing among the countries who have developed local capacity and capability. Data interpretation from radiotracer and sealed source applications are of a very key in strengthening the development of the technology and increasing its use in various industries. The confidence by industry to use this technology (product) is enhanced if clients know that it has been thoroughly evaluated by an independent, competent accreditation body to provide the third party assurance that the inspection body is competent in all aspects to apply it. Accreditation is a formal means of determining the technical competence of inspection bodies to perform specific types of inspection. Accreditation provides a ready means for customers to identify and select reliable inspection services, suitable for their needs. Therefore, the need for inspection bodies applying the technology to establish quality management systems and the means of achieving this is discussed in this paper. It also provides a guide on how personnel certification by an accredited certification body can be implemented. (Key words: Radiotracer, Sealed sources, Quality management, Accreditation)
        Speaker: Mr Stanslaus Alwyn MASINZA (Kenya Accreditation Service, Kenya)
    • 16:15
      Coffee break
    • B03: Radiotracers for Industrial Processes Optimization and Safety I Conference Room M2

      Conference Room M2

      Conveners: Mr Jovan Thereska (Private Consultant), TSec Patrick Brisset
      • 36
        Study by Radiotracer of a Phosphoric Acid Production Line
        The principle of the study is based on the impulse-response concept. The pulse is obtained at the studied reactor inlet by injection of the radiotracer. The study involved a phosphoric acid production line, consisting in particular of two digesters (D1 and D2) and four crystallizers (C1 to C4). Technically, the interest of the study is to establish the residence time distributions to: - Define mean residence times in the various reactors diagnosed; - Define the arrival times, at all studied compartments: digesters D1 and D2, crystallizers C1 to C4; - Identify the flow pattern in each reactor (perfect mixer, piston, ... .etc); - Identify potential process failures (dead volumes, shorts ... etc). The study was conducted in two phases: - First injection of radiotracer, at the inlet of digester D1; - Second injection of radiotracer, at the inlet of crystallizer C1. The radiotracer used is 131I, as liquid Na131I. The two injections of radiotracer, have established with precision the residence time distributions in the studied reactors and flow regimes prevailing there. From the response-curves, product arrival times and mean residence times were also determined.
        Speaker: Mr Rachad ALAMI (CNESTEN (Centre National de l'Energie des Sciences & des Techniques Nucléaires), Morocco)
      • 37
        Studying Flow Dynamics of Catalyst Powder in CCU for Troubleshooting
        Gamma scanning and radiotracer applications are very effective and inexpensive tools to understand and optimize the process as well as troubleshoot the various types of problems in many chemical, petrochemical industries and refineries. These techniques are noninvasive, hence the problems can be pinpointed online which leads to reduce the downtime, schedule the shutdown and maintenance of the plant equipment, rendering huge economic benefits. In a leading refinery of India, the Catalytic Cracking Unit (CCU) was malfunctioning. It was suspected by refinery engineers that the catalyst powder is being carried over to the fractionator which could have lead to erosion of the fractionator column internals resulting their rupture, consequentially the fire hazard. To understand the flow behavior of catalyst powder and to ensure the mechanical integrity, catalyst accumulation and choking, both radiotracer study and gamma scanning of the CCU reactor was carried out. The reactor consists of a riser, three primary cyclones and three secondary cyclones. Gamma scanning of the reactor was carried out with the help of automatic gamma scanner using 1.8GBq of Co-60 sealed source. Results showed that catalyst powder was accumulated in one of the secondary cyclones and uneven density distribution was observed in another secondary cyclone. The radiotracer study was carried out using irradiated catalyst powder as a radiotracer which contains 0.9GBq of Na-24. The radiotracer was injected in the reactor through specially fabricated injection system. Radiation measurement was done using thermally insulated and collimated NaI(Tl) scintillation detectors located at various strategic locations coupled to multi-detector data acquisition system. The data were mathematically analysed. It was confirmed that the catalyst powder was accumulated in one of the secondary cyclones with no flow downwards. This resulted in excess powder available, to travel along with hydrocarbon towards fractionator. Since the quantity of powder released through hydrocarbon outlet of CCU was higher than the designed value, the catalyst powder was observed in various zones of the fractionator. Mathematical modelling of the radiotracer data obtained at various locations corroborated the scanning results.
        Speaker: Mr Vivek Yelgaonkar (Board of Radiation and Isotope Technology, Navi Mumbai, India)
      • 38
        The Application of CFD for Modelling Flow and Visualization in a Cement Mill and Experimental RTD Validation Using Radiotracer Technology
        Cement manufacturing represents an energy-intensive process due to the large power consumption of mills which are an integral process units of the entire cement manufacturing process. Therefore, performance optimization of cement mills is key in ensuring inefficiencies. Yet, performance optimization of such mills is impossible without adequate technical information about the milling process. Experimental residence time distribution (RTD) techniques are known to provide accurate process information and are useful in the validation of computational fluid dynamic models of the particular process under study. This first part of the study presents key process parameters of a cement mill obtained using the radiotracer residence time distribution (RTD) technique at the Ghana Cement plant located in Tema in the Greater Accra region of Ghana. 40mCi of liquid 198AuCl4 agglomerated with cement powder and water was used as the radiotracer and introduced at the mill inlet. The passage of the radiotracer at the outlet was monitored by an external sodium iodide scintillation detector. Data analysis revealed the presence of dead zones or channeling within the mill as indicated by the disparity in the experimental mean residence time of 33.65 minutes and theoretical mean residence time of 58.15 minutes. In the second part of the study, ANSYS CFD Simulation Software will be used to model the flow in the cement mill for visualization as a complimentary method to the radiotracer RTD technique. ANSYS DesignModeler will be used to create the geometry of the 11.4 m long mill with a diameter of 3.6m and ANSYS meshing used to create the computational mesh. FLUENT, the fluid analysis tool of the ANSYS sotware, will be employed to calculate the fluid flow throughout the geometry using the computational mesh, and CFD-Post for the analysis of the results in the form of velocity profiles. Particle tracking discrete phase model (DPM) will be used for the RTD simulation by tracking virtual particles injected at the inlet of the mill and recording the time required for them to reach the outlet. The results of the CFD simulation will aid the optimization of experimental parameters of the radiotracer RTD technique for cement mill investigations.
        Speaker: Ms Hannah Affum (Ghana Atomic Energy Commission, Accra, Ghana)
      • 39
        Radiotracers for Pulp Flow Dynamics Study in Three Different Phosphoric Acid Reactors
        Radiotracers are the method of choice to diagnose the functioning of the chemical reactors providing the most important parameters of the flow hydrodynamic and homogenization. It is known that radiotracers are the most sensitive and accurate techniques for online measurements of process parameters in industrial chemical reactors. Thus three different chemical reactors for the production of phosphoric acid in Tunisian phosphate processing plant were diagnosed by applying radiotracer method. The diagnosis of these reactors hydrodynamic behaviors was requested to evaluate the necessary parameters for assessment of the current performance and for planning further action to improve their efficiency. Tracer tests were carried out under production condition using 131I (Na131I in powder form). The radiotracer was solved in some 0.5 l water and was injected at the entrance of the reactor inside the central unit. The injection was performed instantaneously (as Dirac pulse). Two scintillation probes (2”x2”) were placed looking at the exit pipe from reactor. Both gamma detectors were well collimated with lead shield to reduce the influence of background radiation. The measuring time was fixed 10s in order to detect fast movements inside and outside the reactors, in particular to measure the flow rate of the internal recirculation inside the reactor. The experiment allowed determination of the experimental RTD curves, the MRT, the flow rate of internal recirculation, the coefficient of internal recirculation, the dead volume rate, and identification of the mixing model corresponding to the whole reactor system operation.
        Speaker: Ms Haifa Ben Abdelouahed (CNSTN, Tunisia)
      • 40
        Residence Time Distribution Study of Geothermal Vapor Flow in Pipe Using Axial Dispersion Modeling
        In the present study, the residence time distribution of geothermal vapor phase flow is studied using axial dispersion model. The experimen is carried out by injection of Krypton-85 (85Kr) gas isotope into 10 inch pipe diameter containing dry geothermal vapor. The pressure and the temperature of the vapor are 8 kg.cm-2 and 170oC respectively. Three collimated radiation detectors positioned respectively at 127, 177 and 277 m from the injection point are employed to capture gamma radiation from the injected 85Kr isotope. The data represents residence time distribution (RTD) of isotopes in the selected experimental section. During the experiment, the flow properties is assumed time invariant, therefore the flow properties is also assumed linear in character. Flow parameter calculated using first moment method shows that the flow rate of the vapor is 11 m.s-1. Model parameter, represented by the Peclet number (P_e), predicted from best fitting of the axial dispersion model to the experimental data is 223, whereas the coefficient of molecular diffusion (μ) calcualted from the Peclet number is 0.5 m2.s-1. The experiment concludes that the vapor flow is dominated by convection transport and the flow pattern tends to follow plug flow due to big value of the Peclet number. Keywords: vapor phase, geothermal, residence time distribution (RTD), axial dispersion model, 85Kr, Peclet number.
        Speaker: Mr Sugiharto Sugiharto (Center for Isotopes and Radiation Application, Indonesia)
      • 41
        Radiotracer Investigation of a Pulp and Paper Mill Effluent Treatment Plant
        **Abstract** Background of the study: Pulp and paper industry is highly dependent on water for most of its processes, producing a significant amount of wastewater that should be treated to environmental standards before discharging into the atmosphere. The wastewater generated primarily consist of substantial amount of organics, inorganics, nutrients, toxic and pathogenic compounds which are treated in an effluent treatment plant (ETP). Effluent treatment plant is a combination of primary, secondary, tertiary and advanced treatment and vary industry to industry according to the process utilized. Effective performance of ETP is crucial both environmental and economic point of view and radiotracer technique can be effectively used to optimize its performance and detect anomalies like dead zones, bypassing, channelling etc. Methodology: A detailed residence time distribution (RTD) analysis of the aeration tank and secondary clarifier were carried out at Shreyans Paper Ltd., Ahmedgard was carried out using Iodine-131 (131I) as radiotracer to detect possible anomalies in the system. The aeration tank and secondary clarifier had capacity of 5472 m3 and 1017 m3 respectively. Flow rate of effluent water at the inlet of aeration tank was 5.21± 0.1 m3/min. A pulse input 131I was injected 18 m from the inlet of aeration tank and monitored using eight scintillation detectors placed at various locations of the reactors. These detectors are attached to the data acquisition system (DAS) using wired network that facilitated collection and visualization of the online data. The recorded RTD data were used to evaluate the residence mean residence time (MRT). Result: The MRTs obtained from the experimental RTD data were found lower than their respective theoretical MRTs. Estimated dead volume of the secondary clarifier was found to be 30%, that indicates significant capacity of the tank is inoperative reducing its treatment efficiency. Conclusion: Radiotracer technique is a very effective tool to study complex industrial effluent treatment plant and identifying flow anomalies in the process unit. Keywords: effluent treatment plants, wastewater, RTD, radiotracer
        Speaker: Mr Vikas K. SANGAL (Department of Chemical Engineering, Thapar University, Patiala, Punjab, India)
      • 18:00
        Discussion
    • A04: Radiation For Environmental Protection I IAEA Board Room B/M1

      IAEA Board Room B/M1

      Conveners: Mr El-Sayed Hegazy (Prof. at Egyptian Atomic Energy Authority), TSec Sunil Sabharwal
      • 42
        Ionizing Radiation Induced Decomposition of Antibiotics in Wastewater
        Background of the study Wide varieties of toxic organic compounds are entering the aquatic environment. The main sources of these impurities are the waste water treatment plants for domestic sewage. The co-occurrence of sublethal antibiotic concentration and high density of microbial population provides ideal condition for facilitating the selection and propagation of resistant bacteria in sewage treatment plants. To reduce the amount of harmful organic compounds entering into the receiving bodies of waste water a family of new technologies with the name advanced oxidation processes (AOP) is under development. In these technologies highly reactive, oxidizing radical intermediates (mainly OH radicals) are produced by various techniques, e.g. , by ionizing radiation. Radiolysis provides the benefit to produce reactive oxidizing ($^{\bullet}$OH and H$_2$O$_2$) and reduce (O$_2^{\bullet}$, $\mathrm{e}_{\mathrm{aq}}^-$ and $^{\bullet}$H) species (or from a kinetic point of view highly reactive electrophile and nucleophile species) in situ from water Methodology Electron pulse radiolysis experiments were conducted using a Tesla Linac LPR-4 accelerator with kinetic spectrophotometric detection. A $^{60}$Co facility with $11.5$ kGy/h dose rate was used for $\gamma$-irradiation. LC/ESI-MS was used for final product analysis. The samples were also characterized by COD, TOC, TN and pH measurements and by complex toxicological analysis. Results The oxidative and reductive decomposition of penicillin derivatives was studied, the change in the antimicrobial activity of the drugs was followed. The reaction mechanism of $^{\bullet}$OH induced oxidation of penicillins indicates the existence of a short-living and a stabilized long-living $^{\bullet}$OH adduct to the sulfur. The $\mathrm{e}_{\mathrm{aq}}^-$ is accommodated on the carbonyl groups of the penicillin skeleton yielding ketyl radicals. Penicillins react with the hydrated electron somewhat similarly to a tripeptide. It appeared that excessive or insufficient absorbed dose is deleterious in relation to elimination of antibacterial activity. At low radical exposure the forming products exhibit enhanced toxicity and antimicrobial potency. The adverse effect at high radical exposure presumably arises from the forming polyhydroxylated phenolic compounds. The $^{\bullet}$OH induced decomposition of sulfonamide antibiotics in dilute solutions was also studied by a wide variety of analytical techniques. The degradation was shown to start with $^{\bullet}$OH addition to the aromatic ring, the cyclohexadienyl type radical thus formed reacts with dissolved oxygen transforming to peroxy radical. This radical yields hydroxylated molecules by HO$_2^{\bullet}$ elimination, or it undergoes ring opening to aliphatic compounds. Conclusion It was shown that $\mathrm{e}_{\mathrm{aq}}^-$ and $^{\bullet}$OH are able to demolish the penicillin’s $\beta$-lactam system responsible for their antimicrobial activity. However, careful optimization of the advanced oxidation process, determination of the dose necessary for decreasing the toxicity and improving the biodegradability is necessary. Based on complex investigations for both types of antibiotics the degradation with the formation of inorganic ions is multistep process, the molecules first are step-by-step oxidized and then mineralized.
        Speaker: Ms Erzsebet Takacs (Centre for Energy Research, Hungary)
      • 43
        Ionizing Irradiation-Induced Degradation of PPCPs in Aqueous Solution
        Pharmaceutical and personal care products (PPCPs), especially the pharmaceutically active compounds (PhACs) such as antibiotics and hormones have attracted great concerns worldwide for their persistence and potential threat to ecosystem and public health. PPCPs are being increasingly detected only recently and considered as potential hazardous to ecosystem owing to the rapid development of analytical techniques which enable to quantify PPCPs at trace level and investigate their fate and transformation pathways. Ionizing irradiation is a promising alternative for degradation of PPCPs in aqueous solution. The studies reviewed have demonstrated that ionizing irradiation was effective to degrade a wide range of PPCPs in aqueous solution. Many PPCPs such as antibiotics and X-ray contrast agent could be removed completely by radiation. Solution pH is a key factor to affect PPCPs degradation. However, high doses are needed for mineralization and toxicity reduction. Development of the combined processes of ionizing irradiation with other techniques such as H2O2 and ozonation would be a solution to increase the rate of mineralization and reduce the cost. In most cases, •OH radicals are the major reactive species responsible for degradation of PPCPs by irradiation. Identification of the intermediates and end products, addition of a radical scavenger and the application of pulse radiolysis technique are the most tested methodologies to explore the reaction mechanism of radiation-induced degradation and optimize the degradation efficiency. The majority of studies on PPCPs removal using ionizing irradiation have been orientated towards the treatment performance and effects of operational parameters in pure water solution. Moreover, high concentrations of PPCPs were used in most studies for detecting those compounds easily, which can only reflect some situations such as the treatment of industrial pharmaceutical effluent and are far from the real situation in water matrix. From a practical point of view, studies on the decontamination and disinfection of the real effluent or water containing PPCPs by ionizing irradiation should be paid more attention and the transformation byproducts are of concern owing to their potential stability and toxicity. The bioluminescence inhibition assay with Vibrio fischeri has been used to evaluate the toxicological effect of PPCPs in aqueous solution after ionizing irradiation. Research on the toxic evaluation of parent compounds and their degradation byproducts using a variety of methods are needed in future studies.
        Speaker: Mr Jianlong Wang (Tsinghua University, China)
      • 44
        Efficacy of Electron Beam Irradiation to Address Emerging Microbial Contaminants in Water Reuse Programs
        Water availability is a major challenge facing municipalities around the world. To meet growing residential and agricultural needs, there are major water reuse programs around the world. These reuse programs span all the way from indirect potable reuse to direct potable reuse. The underlying hypothesis was that eBeam technology can breakdown the emerging contaminants of concern in water reclamation and reuse projects. We also hypothesized that the inactivation and elimination of contaminants by eBeam technology can be achieved cost-effectively. Having this technology in the “tool-box” of water reclamation technologies would open up innovative high-value, commercially-viable, and environmentally sustainable solutions and strategies for water reuse High energy electron beam irradiation was found to be effective in eliminating a variety of emerging microbial contaminants such as hepatitis A virus, norovirus, rotavirus as well as protozoa such as Cryptosporidium parvum. Additionally, eBeam was effective at achieving significant reductions of bacterial pathogens such as Shigella spp., Aeromonas spp., and Salmonella spp. Based on these studies, it was found that viral pathogens are the most resistant to eBeam irradiation and protozoan oocysts were the most sensitive. If 5 kGy eBeam is used for water reuse programs, greater than 50-log reduction of bacterial and protozoan pathogens can be achieved. The log reduction of viral pathogens however was significantly lower ranging between 1 and 3 logs. These results suggest that eBeam irradiation technology can be major cost saving for water reuse programs since it avoids the needs for other disinfection treatments and expensive membrane filters (to remove pathogens). The outcome of these analysis indicated that for large municipalities that require effluent treatment in the hundreds of millions of gallons per day, the minimum power requirement is at least 1 MW. Presently, commercial off the shelf (COTS) eBeam technology is available at significantly lower power ratings.
        Speaker: Mr Suresh Pillai (National Center for Electron Beam Research, United States of America)
      • 45
        Toxicity Assays Aplications for Assessing Acute Effects for Radiation Decomposition of Organics in Waters
        The knowlege for using electron bem irradiation for pollutants degradation is developing. Textile effluents and pharmaceuticals were the samples submitted to irradiations and to acute toxicity assays. Electron Beam Accelerator was the radiaiton source used for the treatment in batch experiments. Dafnids, rotifers and bacteria were applied for toxicity measurements. All the assays were performed at LEBA/IPEN (Environmental Biological Assays Laboratory). Doses required for decomposition of organics in water and related toxicity indicated that reduced colour of effluents with 2.5 kGy and 5 kGy. These doses were also suitable for toxic effects removal at pharmaceutical solutions (fluoxetine in sewage; propranolol and fluoxetine mixture and at fluoxetine and voltaren mixture). Part of real textile effluent (about 35% of samples) were very toxic (CE50 < 5%) for daphnids and luminescence Vibrio fischeri. The surfactants contained at textile effluent were the most toxic compound. Vibrio fischeri luminescence was confirmed as one of the most sensitive assay, followed by Ceriodaphnia dubia, Brachionus plicatis rotifers and Daphnia similis.
        Speaker: Ms Sueli Borrely (Instituto de Pesquisas Energéticas Nucleares, IPEN-CNEN/SP, Brazil)
      • 46
        Radiation Technology Application in Environmental Protection
        Nitrogen oxides (NOx) , sulphur dioxide (SO2), volatile organic pollutants (VOCs), polyaromatic hydrocarbons (PAHs) and dioxins are still main air pollutants. They are mostly formed during fossil fuels combustion, solid waste incineration or at other industrial processes. In recent years, cargo ships are the major emission source of SO2 and NOx emission generating very high concentrations of these pollutants in off gases. Electron beam (EB) flue gas treatment technology for purification of gaseous effluents from coal fired boilers after testing in Japan, US, Germany, Poland, China and Bulgaria has been implemented in industrial scale in Pomorzany Power Plant, Szczecin, Poland. It is a dry scrubbing process with ammonia addition, high removal efficiency of SO2 ( > 90% ) and NOx ( >70%) were obtained at 8 kGy absorbed dose, benign products were formed. EBFGT is also a very promising technology to remove SO2 and NOx from flue gas generated by oil fired burner plants what was demonstrated at the pilot test carried out in Saudi Arabian oil refinery plant using a mobile accelerator. High removal efficiency of SO2 can be easily achieved at low dose, however it needs very high does ( i.e., high energy consumption ) to obtain high removal efficiency of NOx. EB technology combined with catalyst to increase removal efficiency of NO emitted from stationary source was investigated through computer modeling simulations. The feasibility to remove SO2 and NOx from off gases generated from cargo ship by using EB technology was investigated, preliminary results showed that EB technology might be used to remove SO2 and NOx from off gases emitted from cargo ship with presence of wet scrubbers instead of ammonia addition. NOx removal efficiency was increased from 3% ( EB only) up to 62% ( EB combined with 4.5% salty water scrubbers) at 8.8 kGy absorbed dose at 90 Celsius degree for the initial concentration of NOx being 1500 ppmv with 500 ppmv SO2 presence. EB technology might be used for PAHs and other organic pollutants removal as well. Recently emerging organic pollutants have been detected in tap water or ground water , their persistence cause people’s concern. Institute of Nuclear Energy and Technology (INCT) researchers have studied perfluorinated organic compounds ( perfluoctanoic acid as a representative compound) destruction in aqueous solution by using EB or gamma irradiation. It showed that more than 80% PFOA was decomposed at 5 kGy dose under gamma ray irradiation in argon-saturated solution of pH 2.0 containing 20 mg/L of t-butanol for initial concentration of PFOA being 1 mg/L; under EB irradiation, nearly 100% PFOA was decomposed at 105 kGy dose. In order to get better understanding decomposition mechanism of PFOA under EB irradiation, a computer simulation was carried out. Good agreement was obtained between calculation and experimental results.
        Speaker: Ms Yongxia Sun (Institute of Nuclear Chemistry and Technology, Poland)
      • 10:40
        Discussion
    • B04: Mitigating Climate Change: Protecting Coast Line and Environment Conference Room M2

      Conference Room M2

      Conveners: Ms Catherine Hughes, TSec Patrick Brisset
      • 47
        Radiotracer Methods for Understanding Contaminant Dynamics in Aquatic Environments
        Radioactive tracers have a distinct advantage in tracing contaminant migration in natural systems and characterising contaminant mobility and uptake into living organisms in already-contaminated environments or at trace (environmental) levels. To use the contaminant itself in its non-radioactive form, concentrations significantly higher than the normal contaminated background level are commonly required which may be undesirable from a toxicological, chemical or regulatory perspective by impacting on the very processes under study. In contrast, radioactive forms of the contaminant can often be more easily measured (often in-situ or non-destructively) and imaged at trace levels (using autoradiography), and usually have the advantage of a short half-life to remove residual contaminant. As such radiotracers have a valuable role to play in contaminant dynamics studies from the lab scale to the field. In the lab, radiotracers are well established in studies of contaminant kinetics and bio-distribution in living organisms, in interactions with non-living natural environments e.g. sorption to soils and sediment, rocks and organics matter, and in tracing contaminant flow pathways and rates. Radioisotopes of heavy metal contaminants (e.g. Cd, As, Se, Zn, Pb, Hg), nutrients (P, C) and the shorter-lived isotopes of longer lived radioactive contaminants such as Cs and Sr are commonly used in environmental contaminant studies. Recently, there is increasing interest and benefit in using radiotracer versions of emerging environmental contaminants such as persistent organic compounds or nano-particles. While most radiotracer work is conducted in laboratories, this approach can be up-scaled to field environments. There are obvious scientific benefits of conducting studies in situ, where the tracer interacts with the complex natural environment rather than an artificially simplified laboratory representation. However there are few examples where this has been done. Since the first field scale uses of radiotracer in the mid-1950s, the majority of field scale radiotracer applications have been in the nexus between industry and environment –sediment transport in harbours and dams, effluent dispersion from outfalls and in mining and oil extraction. Exceptions include whole ecosystem studies in the Canadian Experimental Lakes in the 1970s, heavy metals downstream of a uranium mine in Kakadu NP in Australia, and studies demonstrating the retardation of metals and nutrients in studies in Sweden. Increasingly public and regulatory concern about the potential impact and perception of radiotracing in field environments has made these methods appear largely inaccessible to the research community. However, the introduction of new biota dose modelling tools and guidelines over the past two decades has provided improved evaluation of the environmental impact of radiotracer releases to the environment and ensure and demonstrate their safe use.
        Speaker: Ms Catherine Hughes (ANSTO, Australia)
      • 48
        Nuclear Technologies Applied to Sediment Transport in River, Estuarine and Oastal Zones to Validate CFD Codes
        Siltation in harbour is a lonstanding problem which could generate important costs for maintenance program to secure nautical conditions. This paper reports different studies on sediments in France (Le Havre, Bordeaux, Saint-Michel and Fort-de-France) aiming to characterise the rheological properties of sediment, analyse sedimentation-consolidation processes and propose a numerical model for simulating sediment dumping and water injection dredging. Two non-intrusive techniques are used to measure the time evolution of the vertical profile of concentration during batch settling test. The first one is a Magnetic Resonant Imaging (MRI) vertical prototype used on Gironde estuary. The second is an X-ray ‘home-made’ prototype used on Seine estuary. Both are used to observe the sedimentation and the consolidation processes of natural cohesive sediments that was sampled close to Ports. They provide both movements of the supernatant/suspension interface and the isoconcentration lines of the process. A space-time based method is proposed to close the governing equation. Two different computational fluid dynamic (CFD) codes are used to simulate observations in well controlled laboratory conditions. The one is an open source and industrial 2D code (Telemac) while the other is a research and modern 3D code (NSMP). Both are considered to reproduce sedimentation consolidation of very fine sediments from sites of studies with an analysis of what happens when cohesive and non cohesive sediment are presents. Even through the results are satisfying, there are many questions arising from these exercices. More experiments (using nuclear tecnologies) are therefore essential to confirm interpretations of processes and further improve their modelling. Since the CRP F22066 is formed, there is a new hope to tackle this longstanding challenge.
        Speaker: Mr Damien Pham Van Bang (Laboratory for Hydraulic Saint-Venant, France)
      • 49
        Radiotracer Study to Investigate the Spatial Dispersion Pattern of Dredged Materials in Hooghly Estuary, West Bengal, India
        Maintenance of adequate draft in navigation channel for movement of ships from the sea to the port is a serious concern for port authorities. Available draft gets reduced in course of time due to silt deposition on the channel bed and one has to resort to maintenance dredging which is quite an expensive work. The problem of silt deposition is particularly critical for riverine ports like Kolkata and Haldia where the river and its tributaries carry large volume of silt. The navigational channel leading to Haldia from the Hooghly estuary requires maintenance dredging throughout the year. The dredgers use the tidal window to dredge over the critical shallow area in the navigation channel and then move to the dumping grounds to dispose of the dredged materials. Effectiveness of this dredging and dumping work depends on the location of the dumping site and the dispersion pattern of the dumped sediments, since there is always a possibility of return of the disposed materials to the dredged site during tides. Hence, it becomes essential to identify the pattern and rate of dispersion of the dumped sediments, which subsequently will help in identifying proper location of the dumping site. Keeping this problem in perspective, a project was undertaken to study the movement and dispersion pattern of dredged materials near the dumping site in Hooghly estuary with the help of radiotracer experiment. Use of radioactive tracers offers a cost-effective method of determining transport of sediments caused by tidal currents and processes of erosion, transport, settling and deposition. Radiotracers can be used to obtain quantitative information, such as direction, velocity and thickness of sediment movement. In this project, Scandium-46 in the form of scandium glass powder is used as the radiotracer for tracing the dredged sediments. The tracer is prepared by incorporating 1% of inactive Scandium in the glass composition, then grinding the glass to different grain size fractions to have the same grain size distribution as that of the dredged material. It is then irradiated in the reactor to produce Scandium-46. After preparation of the radiotracer, it is transported to the the dumping site in Hooghly estuary. A specially designed remote operated injection apparatus containing the radiotracer mixed with dredged sediments is lowered into the water with the help of a crane and the mixture is discharged on to the sea bed. After the injection, dispersions of the tracers were monitored using a waterproof scintillation detector mounted on a sledge which was dragged on the seabed. The concentration at different spatial locations are measured. This tracking work was performed during the next five months. Isocount contour maps are prepared from the tracking data, from which the general direction of movement of tracer is drawn and maximum longitudinal and lateral dispersion are estimated. It is observed that the overall movement of the sediments during these five months is away from the main navigation channel. A two-dimensional hydrodynamic model for the study area was also developed and the velocity distribution patterns are compared.
        Speaker: Mr Kalyan Bhar (Indian Institute of Engineering Science and Technology, Shibpur, Howrah, India)
      • 50
        Technetium-99m: From Nuclear Medicine Applications to Fine Sediment Transport Studies
        Technetium $^{99m}$Tc is, nowadays, the most applied radioisotope in nuclear medicine, whose use began in the mid-1960s. Features such as emission of $\gamma$-radiation of low energy ($140$ keV) with very good imaging properties, half-life $\tau_{1/2}=6.02$ h, and production via relatively long-lived generators, facilitating their supply and use in locations far from manufacturing sites, were instrumental for the widespread use of the radionuclide. However, in the aquatic environment, heavy metals and many organic compounds are usually associated with the fine sediment phase (silt, clay, or mud). The fate of these contaminants will be associated with the dynamic behaviour of suspended or bottom sediments in polluted streams. The study of suspended sediment behaviour is central to many environmental studies. Of special interest is the study of individual discharges of contaminants associated with suspended sediments, the short-term dispersion of contaminated material dredged from harbours and reservoirs when dumped into water bodies and the behaviour of natural sediment in suspension in bays, estuaries or reservoirs. Tracking for few hours of the contaminated suspended sediments introduced into streams or in the coastal area by individual discharges could allow the quantitative in situ determination of the advection, dispersion, dilution and sedimentation rates, parameters important for the calibration and validation of hydrodynamic models that comprise both the solid and liquid phases. Radioactive tracers, in appropriate chemical form, are used to label fine sediment by chemical sorption, and some (such as $^{198}$Au and $^{51}$Cr) have been employed to study the dynamics of fine sediment in suspension. But these tracers have to be produced in nuclear reactor each time they are used and require heavy shielding due to the dense flux of high-energy $\gamma$-radiation they emit, which hampers their use in remote areas. Given the favourable characteristics of $^{99m}$Tc, the feasibility of its use for labelling mud, through the chemical reduction of the TcO$_4^-$ eluted from Mo/Tc generators, was studied in laboratory with regard to the following aspects: 1) labelling yield as function of different factors (type and amount of reductant; effect of pH; sediment concentration; contact time; labelling stability); and 2) hydrodynamic behaviour of labelled and non-labelled sediment, through sedimentation tests. The laboratory tests were successful and this new use of the $^{99m}$Tc allowed already interesting results obtained in various applications: Montevideo Bay (Uruguay), Pampulha Hydrographic Basin (Brazil), Orinoco River (Venezuela), environmental impact due to the fine sediment originated from bottom discharge of small hydroelectric power plant (Brazil), etc. The work performed in some field applications used second week generators obtained, at no cost, from Nuclear Medicine laboratories. The reason is that the $^{99m}$Tc detector for environmental applications is placed into the water, in $4\pi$ geometry and for medical applications it is situated externally to the patient. So, the necessary activity concentrations for environmental use (Bq/m$\ell$ in water) are much lower ($10^{-7}$) than in nuclear medicine utilization (Bq/m$\ell$ in blood).
        Speaker: Mr Jefferson Vianna Bandeira (National Nuclear Energy Commission (CNEN-CDTN), Brazil)
      • 51
        The Use of Nucleonic Gauge JTTX in the Port of Nantes Saint Nazaire
        There is a continuous sedimentation in harbour basins and access channels. Therefore maintenance dredging is necessary. The depth necessary for sailing includes the free space between the keel and the bed of the channel called keel-clearance . Tests on physical models indicated that free movement of ships in the harbour is possible upto silt density 1.2 g/cm3. The layer of fluid mud (silt) where the density equals 1.2 g/cm3 is defined as “sea bed”. This layer shifts upwards with time due to deposition resulting in decrease in the “nautical depth”. To keep the required nautical depth it is necessary to measure the depth periodically The depth is usually measured using an echo sounder. The upper trace recorded by the echo sounder is taken as the bottom of the channel. It is misleading in the case of channels with muddy bottoms. In these conditions the echo sounder readings cause excessive dredging adding extra cost. This can be avoided by the measurement of sediment density at different depths. To effectively determine when and how dredging operations must be undertaken, the underwater sediment and mud layers must be monitored and analysed. This paper presents an innovative vertical profiling technique measuring the density versus depth of the sediment layer. The instrument uses X-ray to measure the sediment density and has been developed by the French Atomic Energy Commission and ALTAIX Cie. The information is used for two important aspects. 1. the quality control of dredging works where the data is used to determine the dry matter content of the dredged material and to know precisely the real solid matter removed during the dredging operation 2. In combination with echo-sounding survey methods, it is used for optimizing the dredging works based on the concept of navigability depth limit. Ships can operate through loose mud layers if the physical characteristics of the mud stay below a critical limit. Nowadays the measured physical characteristic in many ports is density. The navigability depth limit is usually corresponding to the density 1.2. The proposed measurement technique allows visualization of density and enables ports to evaluate nautical depth criteria. Dredging only when the navigability depth limit is above the navigation depth allows very important savings. The paper will present the operation of the gauge in the Port of Nantes Saint-Nazaire (France).
        Speaker: Mr Patrick Brisset (Internationa Atomic Energy Agency (IAEA), Vienna, Austria)
      • 52
        Water Renewal in Montevideo´s Bay II: a Compartmental Fractional Model for Tritium Kinetics
        This paper describes the construction of a new compartmental fractional model for water renewal in Montevideo’s Bay that improves a conventional two compartments model [1]. The validity of the fractional kinetic model and its practical applicability are discussed. The available evidence suggests that the highly polluted Montevideo’s bay operates as an intermittent tidal pump that injects contaminants in the nearby coastal waters, with potential effects on the beaches located east to the bay’s mouth. In order to assess this effect, several field studies were done in the bay itself and in the adjacent coastal waters covering water and sediments dynamics [2]. In the framework of a field research of the dynamics and renewal of water in Montevideo´s Bay, 3.7 ×1012 Bq of tritiated water were evenly distributed in the north-east region of the bay, during five hours of continuous injection. The whole bay was divided in 20 concentration cells, taking into account available bathymetric data and corrections from field data obtained in situ. Tritium concentrations (activities per unit volume) and other relevant parameters (temperature, electrical conductivity, etc.) were measured in vertical profiles during three weeks, in the mid-point of each cell, first twice a day and the on a daily basis. Remnant total tritium activity was estimated from cells volumes and midpoint cells activity concentrations. The details of the measured tritium kinetics, available bathymetric data, water movements in a tidal environment measured with drogues, fluorescent tracers and current meters, as well as the results of computer fluid dynamics modelling (averaged in depth), suggests that in a first approximation the bay can be meaningfully divided in two main compartments: a North-East and a South-West compartment. The time course of the tail of the tritium remnant function suggests the use of fractional calculus to model the process of water renewal. The conventional two compartments model is generalized by the introduction of fractional derivatives (in Caputo´s sense) following a procedure that does not violate mass balance [3]. Fractional order parameters are estimated from available experimental data and the measured time evolution of the tracer remnant function is explained. The wash out kinetics from the bay of toxic chemical substances or dangerous microbial populations, introduced after a sudden contamination accident in the harbor, is described using the fractional compartment model and additional information from CFD simulations. [1] Suárez Antola R (2013) Water renewal in Montevideo´s Bay I: A two compartments model for tritium kinetics, 2013 International Nuclear Atlantic Conference - INAC 2013, Recife, Brazil, ABEN DOI: 10.13140/2.1.2675.2005 [2] Suárez Antola R (2012) Tracer studies in the coastal waters of the Department of Montevideo, Proceedings of the Eight Meeting of the International Centre for Earth Sciences, Mar del Plata, Argentina DOI: 10.13140/2.1.3461.6322 [3] Dokoumetzidis A, Magin R and Macheras P (2010) A commentary on fractionalization of multi-compartmental models, J. Pharmacokinet. Pharmacodyn. 37:203-207.
        Speaker: Mr Roberto Suárez-Antola (Asesor, Ministerio de Industria, Energía y Minería, Uruguay)
      • 53
        The Radiotracer 7Be in Studying Environmental Processes
        THE RADIOTRACER 7Be IN STUDYING ENVIRONMENTAL PROCESSES A. Ioannidou1, A. Vasileiadis1, D. Melas2 1Aristotle University of Thessaloniki, Physics Department, Nuclear Physics Laboratory, Thessaloniki 54124, Greece 2Aristotle University of Thessaloniki, Physics Department, Laboratory of Atmospheric Physics, Thessaloniki 54124, Greece The objective of the study is to define the time delay between the elevation of tropopause and the concentration of the radiotracer 7Be in near surface air in order to understand the aerosol transport inside the troposphere as a part of the general atmospheric cycle transfer. The relatively short-lived 7Be radionuclide (t1/2 = 53.3 d) of cosmogenic origin occurs permanently in the atmosphere. It is formed continuously by the interactions of cosmic-ray particles with atmospheric nitrogen and oxygen. The 7Be production rate depends primarily on latitude, altitude and the 11 – year solar cycle and has been proved powerfull tool in studying atmospheric processes. The concentrations of 7Be in the troposphere and near the ground level show variations which are connected with air mass exchange between the stratosphere and the troposphere, in situation of tropopause folding events. Air coming from the upper troposphere or from stratosphere can be identified by its enhanced 7Be levels. The tropopause marks the boundary between troposphere and stratosphere. The height of tropopause is variable in space and time, because of the latitudinal and seasonal dependence of solar irradiation as well as the changes due to weather patterns. There is a well-marked “tropopause gap” or break where the tropical and polar tropopause overlap at 30°-40° latitude. The break is in the region of the subtropical jet stream and is of major importance for the transfer of air and tracers (humidity, ozone, radioactivity) between stratosphere and troposphere. The height of the tropopause varies seasonally and also daily with the weather systems. Fig. 1 Correlogram between 7Be surface concentration and tropopause height The current study presents an analysis of 7Be data at geomagnetic latitude of 40°N. In Fig. 1 is presented the pattern of the cross-correlation analysis of 7Be surface concentration values and tropopause height. It is clearly shown that after the third day the Correlation Coefficient falls dramatically. The Rmax was found in the third day (~0,44). The study revealed that the concentration of 7Be at surface air is expected to correspond within 3 days after the changes of the tropopause height. Moreover, measurements and calculations throughout the research were extremely beneficial in a variety of ways and led to the following findings: ➢ The verification of the yearly variations of the tropopause height in mid attitudes. ➢ The understanding of aerosol transport inside the troposphere as a part of the general atmospheric cycle transfer. ➢ That the persistence in the state of the atmosphere cannot be ignored. ➢ Temperature and tropopause height indicate the time of transport of a useful tracer radioactive nucleus through air transfer cycles and as a consequence of any other aerosol particle with similar origin inside the tropopause. ➢ Higher values of temperature or tropopause height result to shorter transport times.
        Speaker: Ms Alexandra IOANNIDOU (Aristotle University of Thessaloniki, Physics Department, Nuclear Physics Laboratory, Thessaloniki, 54124, Greece)
      • 10:45
        Discussion
    • 11:00
      Coffee break
    • A05: Advances in Radiation Chemistry Research I IAEA Board Room B/M1

      IAEA Board Room B/M1

      Conveners: Mr Olgun Guven (Hacettepe University), TSec Agnes Safrany
      • 54
        Basic Radical Reactions in Water Treatment by Ionizing Radiation
        Background of the study In the so-called advanced oxidation processes (AOP) and in water treatment by ionizing radiation, which belongs to the class of AOP’s, too, the main goal is to destroy, or at least to deactivate harmful water contaminants: pharmaceuticals, pesticides, surfactants, health-care products, etc. The chemical transformations are suggested to be initiated by hydroxyl radicals. However, some other inorganic radicals may also contribute to initiating the degradation. Methodology The changes due to irradiation were followed by taking the UV-Vis spectra and by measuring the chemical oxygen demand (COD) before and after irradiation. The degradation products were identified after LC separation with MS-MS detection. To obtain information about the degradation, kinetics pulse radiolysis with kinetic spectroscopic detection was used. The spectra of the intermediates were calculated from the kinetic curves (radical concentration versus time, on the $\mu$s time scale) taken at different wavelengths. These spectra give information about the structure of the intermediates. Results The kinetics and reaction mechanisms of a large variety of inorganic radicals with organic molecules were studied. It was shown that other inorganic radicals as $^\bullet$OH also contribute highly to the initiation of degradation in most AOP’s. Cl$^{-}$ and HCO$_3^{-}$ in the treated water reacting with $^\bullet$OH transform to the Cl$_2^{\bullet-}$ and CO$_3^{\bullet-}$ oxidizing. Reactions of $\mathrm{e}_{\mathrm{aq}}^-$ and H$^\bullet$ water radiolysis intermediates may also contribute to the degradation. In the primary reactions of all these radicals with organic molecules, carbon-centred radicals are produced. The reactions of the carbon-centred radicals with dissolved oxygen (DO) basically determine the oxidation rate. The peroxy radicals formed in the reactions of aliphatic carbon-centred radicals with DO may transform to peroxides and hydroperoxides, with the intervention of these intermediates gradual degradation takes place. Aromatic carbon-centred radicals (cyclohexadienyl radicals) in reversible processes react with DO, where the ring degradation is suggested to take place from the aromatic peroxi radicals. The primary carbon-centred radicals in uni- or bi-molecular processes may transform to other, e.g., oxygen or nitrogen centred radicals. These intermediates (e.g., phenoxy or anilino radicals) do not react with DO. Therefore, the initial degradation rate is low when, during the degradation reactions, there is a possibility for the formation of these radicals. Conclusion The carbon-centred radical formed in the reaction of a one-electron oxidizing radical with an organic molecule undergoes a second oxidation step when it reacts with DO. This reaction may be followed by further oxidations starting from the peroxy radical thus formed, or from the peroxide/hydroperoxide stabilization products. These reactions increase the degradation efficiency with a result that the one-electron oxidants induce $2$–$4$ electron oxidations. When the radical does not react with DO, the degradation rate is low.
        Speaker: Mr Laszlo Wojnarovits (Centre for Energy Research, MTA, Hungary)
      • 55
        Synthesis of Novel Fabrics for Extraction of Uranium from Seawater
        Abstract The world’s oceans contain more than 4.5 billion tons of uranium; however access to this resource is limited by the ability to extract uranium from seawater efficiently. Lacing fabric substrates with chemical functionalities specific for uranium adsorption is one approach to meeting this challenge. Advanced adsorbent materials are being developed using polymeric substrates with high chemical stability, excellent degradation resistance and improved mechanical properties. Fabrics include polypropylene, nylon and advanced Winged Fibers from Allasso industries featuring extremely high surface areas for improved grafting density. Using Co-60 gamma source and 10-32 MeV electron beam linear accelerator, the various fabrics have been irradiated over a wide range of dose rates, total doses and temperatures. Innovative vinyl phosphate and oxalate exhibiting high distribution coefficients and selectivity for uranium along with excellent potential for free radical polymerization have been utilized in the functionalization of the fabric substrates. Azo compounds with higher selectivity have also been utilized but have required the use of a grafted chemical precursor. Attachment of the chelating adsorbent or its precursor to the substrate polymer is maximized through the optimization of numerous variables including monomer concentration, dose rate, total dose, solvent and temperature. Following irradiation, fabrics are washed, dried and weighed to determine the degree of grafting (DoG). The presence of monomer in the fabrics is verified using numerous experimental techniques including X-ray photoelectron spectroscopy (XPS), scanning electron microscopy-energy dispersive spectroscopy (SEM-EDS), and Fourier-transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR). Zeta potential measurements allow for surface charge measurements to confirm the negative charge required for uranium chelation. The fabric capacity for uranium extraction was tested by rotating samples for 7 days in a rotary agitator with actual seawater spiked with 0.2 or 1.0 mg∙L-1 uranium. The fraction of uranium in the solution which was removed due to uptake on the fabrics was found to rise with increasing DoG at both uranium concentrations. SEM-EDS measurements are used to map the distribution of adsorbed uranium on the polymeric fibers. Current work includes optimization of grafting density in addition to material characterization on the molecular level and analysis of the sample microstructure. Further testing in synthetic seawater will be conducted to compare the selectivity of each adsorbent fabric towards uranium compared to that of other species, in addition to determining the loading and adsorption rates under various conditions such as pH, temperature and salt concentration. Experiments in real seawater will consider effects of organics on the adsorbent materials, test for durability and reusability and determine kinetics and efficiency of the uranium extraction as a function of degradation.
        Speaker: Mr Mohamad Al-Sheikhly (University of Maryland, United States of America)
      • 56
        Ultrafast Electron Transfer Studied by Picosecond Pulse Radiolysis
        Furthering our knowledge on the reactivity of short-lived species in irradiated water at ultrafast timescales is necessary to understand the competitive reactions occurring within the first ps. The composition of aqueous solutions and the water/solid interface can potentially favour or inhibit one of these competitive ultrafast processes, such as electron hydration, electron hole recombination, proton transfer, or oxido-reduction of the solute. Pulse radiolysis measurements with 7 ps time resolution show that ultrafast electron processes occur in highly concentrated aqueous solution. The reactivity’s of pre-solvated electron, pre-OH• radical and pre-H• atom radical are examined. By measuring the yield of the transient radical after the pulse it is shown that H2O•+ radical undergoes an electron transfer and pre-solvated electron and pre- H• atom are very efficient reducing species.
        Speaker: Mr Mehran Mostafavi (Paris-Sud University, France)
      • 57
        Advances in Etched Ion-Track Polymer Membranes for Environmental and Microelectronic Applications
        Etched ion-tracks membranes are well-known and commercially available membranes for filtration and, in the past decades, have attracted a huge interest for applications in life sciences. More recently, since these membranes serve as template for nanowires or nanotubes fabrication, applications in microelectronics (eg. MRAM for computers) have also been widely investigated. Control over the swift heavy-ion irradiation and subsequent etching condition enables the production of multiple or single channels of high aspect ratio. Playing on polymers chemical structure, crystallinity and track-etching strategies, channels of predefined sizes and geometries can be tuned such as cylindrical, conical or oblade-shaped channels, crossed-channels … Track-etching technique presents the advantage to be industrially scalable. Among other exemples, we will discuss how a large area fabrication of self-standing nanoporous graphene-on-PMMA substrate, interesting candidates for field-emission transistors, can simply be achieved. Ten years ago, we have shown that, after a relatively short etching time, some track-etched nanoporous polymer membranes exhibited an EPR signal witnessing the presence of remaining radicals. These radicals, results of ion-matter interactions from previous irradiation, have been found reactive enough to initiate the radiografting of vinyl monomers. The grafted polymer chains are specifically localized on and all along the nanopores walls. This discovery has opened our applications field from polymer electrolyte membranes for fuel cells to the development of sensors of pollutants in waters. In this talk, we will present our very recent achievements on etched ion-track polymer membranes for sensor applications in environment and microelectronics. The key of success is the use of a peculiar polymer, the poly(vinylidene difluoride) (PVDF). PVDF is a biocompatible and semi-cristalline polymer. Depending its crystillinity phase, it can also be piezoelectric. We will present how we have exploiting these properties for sensor applications.
        Speaker: Ms Marie-Claude DUBOIS-CLOCHARD (Laboratoire des Solides Irradiés (CEA), France)
      • 58
        Using Ionizing Radiation for Studying Radical Reactions with Nitroxides: Implications for their Biological Activity
        Radicals are part of the chemistry of life. The ever-increasing knowledge of the involvement of radicals in diverse pathological processes has expanded the search for more efficient antioxidants that can diminish radical-induced damage.Stable nitroxide radicals are receiving increased attention as potential therapeutic agents because of their pronounced antioxidative activity, low toxicity, and attenuation of oxidative and nitrosative damage in vitro and in animal models of inflammatory diseases. We have used ionizing radiation for elucidating the kinetics and mechanisms of nitroxides reactions with radicals as well as with reduced metal ions and semiquinone radicals. Radicals which are neither good oxidants nor reductants such as carbon-centered radicals generally add to the nitroxyl group forming relatively stable adducts. The reactions of •NO2, HO2•and peroxyl and thiyl radicals with nitroxides proceed via an inner-sphere electron transfer mechanism. The reactivity of nitroxides towards most radicals, excluding HO2• and peroxyl radicals, hardly depend on their structure. In the case of HO2•(pKa = 4.8) the nitroxides reactivity decreases as the pH increases and, therefore, at physiological pH they are poor SOD-mimics. The rate constant of nitroxides reaction with •NO2 is extremely high (7 x 108 M-1s-1), and nitroxides catalytically prevent protein nitration, which is involved in diverse pathological processes. This has been demonstrated in vitro during the peroxidative activity of heme proteins in the presence of H2O2 and nitrite and in vivo using a mouse model of allergic asthma, which is an inflammatory disease,reflected by increased production ofreactive oxygen and nitrogen species.The protective effects of nitroxides in suppressing the increase of main asthmatic inflammatory markers substantiate the key role played by reactive oxygen and nitrogen species in the molecular mechanism of asthma. Nitroxides are superior over common antioxidants, which their reaction with radicals always yields secondary radicals leading eventually to consumption of the antioxidant.Nitroxides act catalytically since their reactions with radicals form the respective oxoammonium cations, which are readily reduced back to the parent nitroxides by biological reductants. The effects of the nitroxides are instrumental not only in protecting against oxidative and nitrosative damage, but also in elucidating the mechanisms underlying these processes.
        Speaker: Ms Sara Goldstein (Institute of Chemistry at the Hebrew University of Jerusalem, Israel)
      • 59
        Influence of N20 and Ethanol on the Chemical Stage of Radiobilogical Mechanism
        The biological effect of ionizing radiation may be rather strongly influenced by the presence of other substances in corresponding medium during irradiation; see the problem of oxygen effect in tumor radiotherapy (at lower LET values). The radicals HO2 arising in diffusing radical clusters formed mainly by densely ionizing ends of secondary electrons are responsible for the enhanced effect in damages of DNA molecules. Their frequency in the dependence on oxygen concentration will be presented, having been established with the help of our model based on the use of Petri nets. There are, of course, other substances (radiosensitive as well as radioprotective) that may influence the radiobiological effect and be practically applied too. We have chosen two of them: N2O and Ethanol (acting in opposite ways). Molecules N2O react with hydrated electrons to form OH radicals which increase DNA damage while Ethanol acts as scavenger of radicals and lowers DNA molecule damage. To create the mathematical model which describes physical and chemical processes in the chemical stage of radiobiological mechanism we have used Continuous Petri nets. It enables us to describe and study the influence of both the main parallel processes: chemical reactions and diffusion of radical clusters. It is possible to study the time change of concentration of individual radicals during this diffusion process, which may be very helpful when the efficiency of different substances present in medium in the DNA damage (radiobiological effect) is to be studied. Concurrently, Petri nets enable us to simulate dependences of radical concentrations on concentration of oxygen, N2O and Ethanol which may be very helpful to study influences of those substances on DNA damage and find out their optimal concentration for radiotherapy and protection of cells against ionization radiation. We have started to study the corresponding problem earlier with the help of analytical model where system of differential equations has been used. The given model has been applied to the experimental data obtained for Co60 radiation. The results of this model have been used for setting of basic parameters of Petri nets model.
        Speaker: Mr Jiri Barilla (Jan Evangelista Purkyne University in Usti nad Labem, Czech Republic)
      • 60
        EPR Characterization of Gamma-Irradiated Xerogels
        Silicate glass was considered as suitable material for dosimetric purposes, and the study of stable paramagnetic centers induced by radiation has proven its potential for radiation dosimetry. Despite its several advantages that make it especially attractive, silicate presents some disadvantages like heterogeneity of chemical composition and high melting temperature. These problems can be resolved by elaboration of silica glass at room temperature via sol-gel method, which was an excellent and economically process offering purity, homogeneity besides to control components and properties of this material. In this study, the sol gel process preparation starts from a solution containing tetraethoxysilane (TEOS) precursor and consist mainly on two steps, hydrolysis and polycondensation. Hence, the sol to rigid glass conversion took place after loss of solvent, with drying gels at room temperatures and then gamma irradiated in order to induce paramagnetic centers. Therefore, we report in this study, the paramagnetic states induced after irradiation in iron doped and pure SiO2 sol-gel glasses. The aim of the present work is to investigate the EPR properties of sol-gel silica glass and to ascertain its possible use for high dose dosimetry. The EPR spectra of unirradiated silica, recorded at room temperature and at 140 K exhibit a silent spectrum. However, major changes occur in the spectrums of gamma irradiated samples are attributed to the formation of non-bridging oxygen hole centers and E’ centers. The spectrum of iron doped silica recorded at 140 K consists of four resonances : g=4,3 attributed to ion Fe3+ , g=8,27 and g=2,73 associated to presence of iron clusters in pores, finally g=1,99 may be due to defects of irradiation in sol-gel material. The preliminary EPR analysis of radiation induced paramagnetic centers in sol-gel silica represents a relevant approach to dosimetry. According to the current results, complementary AFM and FTIR studies are in progress.
        Speaker: Ms Kaouther Marzouki (National Center for Nuclear Sciences and Technologies, Tunisia)
    • B05: Radiotracers for Energy of the Future I Conference Room M2

      Conference Room M2

      Conveners: Mr Muthanna Al-Dahhan, TSec Patrick Brisset
      • 61
        Liquid Holdup Studies in a Cocurrent Gas-Liquid Upflow Moving Packed Bed Reactor with Porous Catalyst Using Gamma Ray Densitometry
        Upflow moving packed bed reactors are widely used in industries for hydrotreating like hydrodenitrogenation, hydrodesulfurization, hydrodemetallization, etc. In these reactors, deactivated catalyst are removed from the bottom, and fresh catalyst are added from the top, gas and liquid phase move concurrently upwards. The catalyst removal occurs only once in a week and that too in small increments. Some of the common problem associated with this reactor are maldistribution, hot spot, and reduced expected conversion. To overcome these challenges detailed study to enhance the understanding of hydrodynamics in this reactor is still required. In this work line-average liquid holdup is determined using Gamma-Ray Densitometry (GRD) in a scaled down lab scale upflow packed bed column. Gamma ray densitometry is noninvasive radioactive technique and can be implemented to monitor the flow distribution even at industrial scale. There are no studies reported on determination of line average phase distribution for packed bed with the porous catalyst using GRD. In this study, a new methodology has been developed to determine the line average liquid holdup for a porous catalyst. Which gives the line average holdup in the void space of catalyst bed plus the line average internal porosity of catalyst. This study has been conducted on a Plexiglas column of 11-inch ID and 30-inch height, randomly packed with extrudate catalyst of 3mm diameter till 24-inch height. GRD scanning is conducted at various axial and radial location. The line average liquid holdup is determined at superficial liquid (water) at 0.017 cm/sec and varying superficial gas (air) velocity in the range of 0.6-7.7 cm/sec. The result showed that the liquid holdup decreased as the superficial gas velocity increased. It was also found that the liquid holdup radial distribution was not uniform. This kind of information is essential to improve the performance of the reactor.
        Speaker: Mr Muthanna Al-Dahhan (Chemical Engineering and Biochemical Engineering Department Missouri University of Science and Technology, Rolla, MO 65409-1230. United States of America)
      • 62
        Bed Expansion Studies in Upflow Moving Catalytic Packed/Expanded Bed Hydrotreating Reactror Using Gamma Ray Densitometry
        Upflow moving catalytic packed or expanded bed reactor are widely used in industries for hydrotreating of feeds with a higher level of contaminants including heavier feeds. In these reactors spent catalyst are replaced periodically by adding fresh catalyst at the top and removing spent catalyst from the conical bottom which supports catalyst bed. While the catalyst moves downwards periodically, gas and liquid phase move upwards. The catalyst is removed in small increments once a week. The other times the reactor operates in upflow packed or expanded bed condition. The problem associated with these reactors is maldistribution, which causes hotspots, sintered carbon deposition and reduces expected conversions. It is seen that the main reason for these issues is maldistribution of phases at the local level inside the catalyst bed region. Bed expansion plays a huge role in local flow distribution of phases. In these reactors the expanded bed region gives the better radial distribution of phases, but less overall mixing intensity of phases as compared to packed bed region. Furthermore, the movement of catalyst particle in expanded bed profoundly affects reaction kinetics in these areas. It is seen that at industrial best operating condition of these reactors the catalyst bed exhibit packed and expanded bed region. Expanded bed can be seen at the top part of the bed. There are no studies done yet to demarcate the expanded and packed bed region. In this work quantification of bed expansion will be done on scaled down lab scale reactor by online monitoring with gamma-ray densitometry (GRD) along the bed height. The time series data obtained from GRD will be analyzed to identify flow regime, and variation in flow regime trend between packed bed with expanded bed region will be used to demarcate the boundary. The analysis of time series are done on time domain (Standard Deviation, Mean, and Variance), Frequency domain (Power Spectrum, Wavelet Analysis) and chaotic analysis (Kolmogorov Entropy (KE)). We focus in this work on the catalyst bed section, which is a plexiglass column of 11-inch (ID) and 30-inch height, filled with extrudate catalyst of 3mm diameter till 24-inch height. The measurements were conducted at superficial liquid (water) velocity of 0.017 cm/sec to 1.78 cm/sec and superficial gas (air) velocity of 1.27 cm/sec to 8.8 cm/sec. This kind of information is essential at industrial scale, for efficient design and operation of these reactors. In this presentation, results and findings are discussed.
        Speaker: Mr Vineet Alexander (Chemical Engineering and Biochemical Engineering Department Missouri University of Science and Technology, Rolla, MO 65409-1230. United States of America)
      • 63
        Radioactive Tracing of an Industrial Scale Continuous Pulp Digester
        Background of the study: Indian paper industry is having an approximate share of 2.6% to the global paper production from ~813 paper mills. The chemical pulping process is widely used to produce paper using different types of raw material such as wood, bagasse, agro residue (wheat straw, rice straw) etc. The raw material is directly fed to a pulp digester along with white liquor to produce pulp. The obtained pulp from the digester is being used to manufacture of various type of paper including writing paper, printing paper, packing paper, etc. The performance of the pulp digester is very crucial for product yield, product quality, overall operating cost and waste generation. Hence, it is important to understand the flow behavior/ hydrodynamics of the pulp digester to optimize operating variables. Methodology: The industrial scale experiments were conducted for radioactive tracing of three tube continuous pulp digester in Satia Industries (India) using radioisotopes Br-82 and Au-198. The tube length and diameter of single tube of pulp digester is 12m and 1.45 m respectively. Wheat straw and white liquor were fed to the digester at 157–169 °C temperature and 5.39–6.45 kg/cm2 pressure. The white liquor was fed at the rate of 360 liter per minute and wheat straw was fed at feeder screw speed of 65 rpm. The radiotracer was injected at the inlet of the pulp digester using high pressure pump. The four radiation detectors were used to record the radiotracer concentration at the inlet and outlet of each individual digester tubes. The recorded radioactive signals were compared and used to elucidate the residence time distribution, mean residence time (MRT) and flow behavior of pulp digester. Results: Approximate ~20% difference were found in MRTs of Au-198 and Br-82. The higher value of MRTs for Au-198 than Br-82 indicating some adsorption of Au-198 on wheat straw. MRTS for Au-198 is representing MRTs of bulk flow (pulp), whereas MRTs using Br-82 represent MRTs of liquid phase only. The segregated, erratic and inhomogeneous flow were observed in first digester tube. The axial dispersion model with plug flow component in series were found suitable for both cases. The non-dimensional axial dispersion coefficient for third digester tube were found as 270 and 250 for Au-198 and Br-82, respectively. Conclusion: The present radiotracer technique is found well suited for tracing of the pulp digester even at high temperature and pressure to identify the malfunctioning such as back-mixing, reverse flow, bypassing and stagnation volume of pulp digester, etc. This technique can be used for locating the leakage, fouling or other abnormalities. Keywords: Pulp digester, Radiotracer, Bromine-82, Gold-198, Residence time distribution, Mean residence time.
        Speaker: Mr Avinash Chandra (Department of Chemical Engineering, Thapar University, Patiala 147004, Punjab, India)
      • 64
        Evaluating the Operating Conditions of a Rectifier Column Using Gamma Column Scanning
        This paper reports the gamma scanning carried out to a rectifier column in one of the refineries in the Philippines. Several scans were performed to gather information on the operating conditions of the column at different sets of operating parameters using a 10-mCi Co-60 source and a 2-inch detector tandem. Result of each scan reveals the presence of blockage at several sections of the column. These blockages cause flooding inside the column when process settings were changed as reflected in the profiles of several scans. Gamma column scanning was able to specify the presence and location of blockages and their effect to the operating condition of the column at varying process parameter settings.
        Speaker: Mr Denis Aquino (Philippine Nuclear Research Institute, Philippines)
      • 65
        Gamma Scanning Technique as an Efficient Investigation Tool for Diagnostics and Troubleshooting in Industry – Case Studies
        In nuclear technique applications in industry, gamma scanning is recognized as a simple but very common and useful on-line investigation technique for diagnostics and troubleshooting in industry. Based on the principle of attenuation of gamma beam intensity according to the density of material while penetrating through the object, gamma scanning provides data or information about situation of components such as pipe, columns to optimize the performance or to identify maintenance requirement. Among a number of applications carried out by CANTI, this paper gives the typical case studies of use of gamma scanning to detect damage, blockage in pipeline and to investigate of malfunction in process columns in the petroleum refinery which provided the technical evidences to engineers in planning the troubleshooting. Gamma column scanning was used to determine the malfunction in the flue gas absorber tower of Dungquat Refinery. The scanning results showed the heavy foam occurred in many trays that help the operator to adjust the operational parameters to recover the normal performance which was confirmed by the re-scanning data afterward. In other applications of gamma column scanning, the inside situation of columns such as tray damage, flooding, deformation of tray… was also detected that is useful to plan the maintenance. In pipeline, gamma scanning technique was used to detect the blockage inside flare pipeline, to inspect the damage of refractory inside the withdrawing well and to detect the part of steel valve dropped and stuck inside the steam pipeline. In many cases, gamma scanning showed as the only technique to solve problem owing to the high penetration capability of gamma ray through the thick steel wall of components that allows to “see” inside the object; and implementation of the online inspection without shutting down the process.
        Speaker: Mr Quang NGUYEN HUU (Centre for Applications of Nuclear Technique in Industry (CANTI), Viet Nam)
      • 66
        Validation of CFD Codes Using Radiotracer RTD Analysis of Stirred Vessels
        ABSTRACT Radiotracer residence time distribution (RTD) and computational fluid dynamics (CFD) are two methods (experimental and numerical) that can be used to study the performance of industrial process reactors. Although all the required parameters of a process vessel can be gotten using RTD methodology results should be used to validate CFD codes. CFD simulations does not only make the design of flow systems much more easier but also better explains the system's flow structure. The aim of the investigation was to used results obtained from a radiotracer RTD analysis of stirred vessels to validate CFD codes. The flow field in the vessel was simulated using CFD multiphase and turbulence models. The simulated flow field was used generate the RTD using a Lagrangian particle tracking method. The simulated RTD curves and mean residence time were in good agreement with experimental results.
        Speaker: Mr Christian Priesley Kofi Dagadu (Ghana Atomic Energy Commission, Ghana)
      • 12:45
        Discussion
    • 13:15
      Lunch break
    • A06: Dosimetry and Standards for Radiation Processing IAEA Board Room B/M1

      IAEA Board Room B/M1

      Conveners: TSec Bum Soo Han, Mr Wilson Calvo (IPEN-CNEN/SP)
      • 67
        Process Control Methods in Radiation Technologies
        Radiation processing has become a well-known and well-accepted technology worldwide using different type gamma irradiation facilities, electron accelerators and X-ray machines. The technology is applied at various fields like radiation sterilization of medical devices, manufacturing of polymer products used in industry and health care, irradiation of various food and agricultural products, as well as the emerging technologies like synthesis of advanced materials and environmental protection. The successful implementation of these technologies depends very much on reliable quality assurance, i.e. the measurement of absorbed dose during process validation and control, the continuous check of machine parameters and the use of mathematical modelling in certain stages of the technology. It is achieved by using harmonized and standardized dosimetry procedures performed with different type and category product specific dosimetry systems. Dosimetry, as part of the total quality system provides quality assurance and documentation that the irradiation process was performed according to the pre-set specifications. Accurate and traceable dosimetry measurements, based on suitable calibration procedures, provide independent means for quality control in radiation processing. In all validation steps (as described in ISO Standard 11137), i.e. during process definition, installation-, operational- and performance qualification, as well as in routine process control, various reference standard and routine dosimetry systems are applied for quality control. In the course of the presentation the main dosimetry procedures, required during the validation steps will be discussed. Thus the selection and use of reference and routine dosimeters for the characterization of the irradiation facility and the establishing of the irradiation technology as well as for routine process control will be highlighted through practical examples. Besides the challenges and solutions relevant to different irradiation facility designs and recent radiation technology requirements will be shown with respect to available process control methods.
        Speaker: Mr András Kovács (Atomic Energy Engineering Co. Ltd., Hungary)
      • 68
        Dosimetry and Process Control for Using Low Energy Electron Beams for Sterilization or Decontamination of Surfaces
        Low energy electron beams (100-200 keV) are used for sterilization or microbiological decontamination of surfaces in the medical device and pharmaceutical industry. This paper describes dosimetry methods used for validation and routine process control of these processes. Dosimetry methods employed in high energy e-beam or gamma sterilization cannot be used at low energy e-beam, where the accelerated electrons are stopped within the dosimeter, and special methodology has been developed for this purpose. It is described how measurement traceability is maintained for dose measurement at low energy electron irradiation, and an uncertainty budget is also developed and described. The basis for establishing a maximum acceptable dose and a dose needed for an effective process is given as well.
        Speaker: Mr Mark Bailey (Risø High Dose Reference Laboratory)
      • 69
        Is IQ/OQ/PQ Part of Irradiation Process Control?
        Regulations and ISO standards applicable for medical devices require that validation of a process shall be performed. In fact, both the U.S. Quality System Regulation 21 CFR Part 820 and ISO 13485:2012 have explicit elements requiring the manufacturer to perform tasks associated with IQ, OQ and PQ. Only after performing IQ, OQ, PQ successfully with a desired result and established documents that verify each phase, the production can get underway. This defined discipline for process validation has proven to be the ideal way to guarantee the best quality production and this, constantly over time. During production, process control is the phase involved in ensuring the process is stable and consistently operating at the target level of performance with variations which have been set accordingly during OQ and PQ. Relevant documents adapted to the radiation processing industry, such as ISO 11137-3, ISO14470, ISO/ASTM51649, ISO/ASTM51702, ISO/ASTM51608, ISO/ASTM52303, AAMI/TIR 29 describe the purpose and the experiments to be conducted during IQ, OQ, PQ and routine control of the process of irradiation. The purpose of this presentation is to show actual results of irradiation plant qualification following the mentioned standards/guides and an approach for routine process control. Preliminarily to those results, the dosimetry system calibration step and a dose measurement inter comparison conducted within the RLA 1013 004 ARCAL project, will be addressed since OQ/PQ results are mainly based on absorbed dose measurements.
        Speaker: Mr Florent KUNTZ (Aerial CRT, France)
      • 70
        Dosimetry Standards and Dissemination Systems for Radiation Processing in China
        In order to adapt the development of radiation processing and ensure that the product has been treated with an acceptable range of absorbed doses in China, a program of high dose standardization was initialed in1983. The high-dose standards and dissemination system has been established at NIM. The ferrous sulfate (Fricke) dosimeter is accepted as national reference standards, the ceric-cerous sulfate and potassium/silver dichromate liquid chemical dosimeters and alnine/EPR dosimeter are selected as transfer standards at NIM. The Fricke, potassium/silver dichromate, several kinds of radiochromic films (RCD), cellulose triacetate (CTA) and polymethylmethacrylate (PMMA) dosimeters have been recommended as routine dosimeters for radiation processing in China. A series of national standards, verifications and technical norms have been enacted and issued on the dosimetry for radiation processing and on the approval of irradiation facilities. This program plays an important role in the dose measurement standardization and product quality assurance for radiation processing. This paper presents a brief overview of dosimetry activities for radiation processing carried out at NIM during the last 10 years. Calibration of systems with the Fricke reference standard and comparison of absorbed dose results obtained from NDAS program with potassium/silver dichromate dosimeter and alnine/EPR dosimeter for radiation processing in China are also discussed.
        Speaker: Mr Yanli ZHANG (Ninational Institute of Metrology, China)
      • 71
        EPR Dosimetry Systems; Assessment and Developed in NCRRT
        During the last two decades, a team of NCRRT researchers developed and assisted many dosimetry systems depending on the electron paramagnetic resonance (EPR) analyzing method. EPR dosimetry is characterized by its non-destructive read-out and the possibility of dose archival. Recently, monosodium glutamate powder and prepared rods containing different concentration of it ($3\times 10$ mm) were studied to be a radiation sensitive dosimeter measured by ESR method of analysis. The dose range from $10$–$90$ kGy tested for powder, whereas, rods are useful in the dose range from $10$–$120$ kGy. NCRRT researchers studied different substances evaluated as; taurine, strontium carbonate, riboflavin, strontium carbonate, anhydrous strontium sulfate, 2-methylalanine, magnesium lactate, ammonium oxalate, and arginine mono-hydrochloride. The response of taurine to $\gamma$-radiation doses in the range from $0.1$ to $50$ kGy was investigated, as well as that in the range from $1.0$ to $20.0$ Gy using numerically enhanced EPR taurine spectra. The radiation-induced defects in strontium carbonate (SrCO$_3$) rod dosimeter in the dose range of $2.5$ Gy–$25$ kGy was investigated using EPR resonance technique. The un-irradiated riboflavin (RF) exhibits a very weak EPR signal ($g = 2.00950$) and upon $\gamma$-ray exposure the signal increases up to an absorbed dose of $50$ kGy. Anhydrous strontium sulfate (SrSO$_4$) has shown a promise candidate as a dosimeter for low dose applications producing unique EPR signals with $\gamma$-rays which it has a linear response relationship ($r_2 \approx 0.999$) in the range of $1$–$100$ Gy. The dosimetric characteristics of $\gamma$-radiation induced free radicals in 2-methylalanine (2MA) pellet dosimeter are investigated using EPR in the high-dose range of $1$–$100$ kGy. The EPR spectrum of irradiated magnesium lactate (ML) rods was characterized by a quartet signal with the spectroscopic splitting $g$-factor of $2.0048700003$ at $0.4$ mT. The useful dose range of the rod dosimeter was $100$ Gy to $80$ kGy. The dosimetric properties of the of ammonium oxalate (COONH$_4$)$_2$H$_2$O studied under low and high radiation doses. The EPR spectra of ammonium oxalate have the spectroscopic splitting $g$-factor of $2.00095$ for C$_2$O$_4^-$ radical detected as EPR signal. The dose-response curves have very good linearity in the range $10$–$1000$ Gy for low doses and show slight sub-linearity in high dose region up to $25$ kGy. Arginine mono-hydrochloride rods ($3$–$10$ mm) were irradiated with $^{60}$Co $\gamma$-rays to study radicals for dosimetric materials with EPR. The rods have significant signal which develops upon irradiation and the intensity of signal increases upon the increase in irradiation dose, in the dose range from $5$ to $120$ KGy. More and more articles ware published by the NCRRT researchers group dialing with this issue represents the unique analyzing method of using EPR in the field of dosimetry.
        Speaker: Mr Seif EBRAHEEM (National center for Radiation Research and Technology, Egypt)
      • 15:55
        Discussion
    • B06: Radiation Techniques for Energy of the Future Conference Room M2

      Conference Room M2

      Conveners: Mr Rubens Martins Moreira, TSec Patrick Brisset
      • 72
        The Gamma Scanning: a Tool for the Quality Control of the Process of Alcohol Distillation
        Gamma scanning is a technology management tool to increase manufacturing efficiency. Modern industrial production requires strict process control, in order to meet established quality standards. The technique of gamma-ray scanning allows nondestructive diagnosis, which has among its applications the study of distillation columns. The method is based on the different degree of attenuation of gamma radiation as it passes through materials of different density. Through the analysis of a vertical density profile, it is possible to identify functioning problems without stopping the industrial process under study, and without physical intrusion. This improves the operational efficiency and reduces the time for maintenance. The present paper shows the results of a study conducted applying the technique of gamma- ray scanning to a distillation column of alcohol from the distillery "Hector Molina". The study revealed the presence of some small anomalies such as the presence of foam in some regions of the distillation column. The identification of these anomalies contributed to improve the efficiency of the tower, improving as a consequence the quality of the obtained alcohol, and contributing to the environmental management system that should be associated to the process of alcohol distillation
        Speaker: Ms Isis María Fernández Gómez (Centre of Radiological Protection and Hygiene (CPHR), Cuba)
      • 73
        A New Method for Detecting Trace Oil Concentration by Neutron Radiography Technique
        Modern Neutron Imaging (NI) facility in the ETRR-2 provided precise information for detection of trace oil concentration in cultural heritage treasures. The presence of high scattered oil materials distorted the neutron radiography quantitative measurements and caused blurred images. This work presented a new technique in precise quantitative measurement and calibration. The technique was based on the scattering correction of images. The correction was not based on the Monte Carlo (MCNP) code simulations, but rather on a real case scattering correction by a designed code. Also, the distinction of this work was showing a real free scattered image that was not performed before. The designed code possesses an extensive set of algorithms for digital image processing. The code has arithmetic menu commands performing versatile operations between images. The installation of excellent neutron imaging (NI) system at the research reactor in Egypt increased the reliance on appropriate software for advanced imaging processing and data analysis. The code provided up-to-date high quality images by designing formula commands supported by all standard mathematical functions. This open source code was used for detection and measurement of trace oil concentration by the neutron radiography (NR) technique.
        Speaker: Mr Tarek Abd El Slam (Atomic Energy Authority (AEA), Egypt)
      • 74
        Leaks Determinations in Reboilers from Natural Liquid Fractioning Units
        INTRODUCTION In recent years, IPEN has developed various techniques based on the application of tracers and radiation sources to solve problems operating facilities oil refining and gas. The objective of the experiments was to identify leaks and passes in reboilers, either thermal fluid or hydrocarbon products in the reboiler of a depropanizer column, in the reboiler of a debutanizer column and, in the reboiler of a stripping column from a fractionation column naphta-diesel. A set of determinations are reported with various radiotracers experiments in reboilers from natural liquid fractioning units, for leaks / passes that could exist in three reboilers. The tracer technique for online detection was used, by using two radiotracer depending on the phase to be investigated: oleic acid labeled with Iodine 131 as a radiotracer for the hydrocarbon phase and an aqueous solution of iodine 131 for the aqueous phase, when necessary. A data acquisition system, a portable PC, and detectors in proper positions were used. Recording values were synchronized as well as ambient background, prior to each injection of radiotracer. Radiation counts were recorded at intervals of 1 second, in each case. Six determinations were conducted by six injection of radiotracer incorporated, either in tubes or shell, as applicable. We achieved detection limits leakage of 0.1 %, of one stream to another.
        Speaker: Mr Carlos Sebastian Calvo (Nuclear Energy Peruvian Institute (IPEN), Peru)
      • 75
        RPT for Tracking Microalgae Cell Movement in Split Photobioreactor Column
        Radioactive Particle Tracking (RPT), is a visualization technique utilizing for multiphase flow systems. This technique has used to track the microalgae’s cells movement through all the segments of growth by tracking a single radioactive particle (Co-60) 200 µCi. This particle was coated by 2mm Polypropylene particle to mimic the motion of the liquid inside the reactor. The Gamma-ray intensity distributions are reveal by a 30 NaI detectors placed uniformly in a certain angles and levels, around the reactor. The performance of split photobioreactor requires in-depth knowledge and understanding for photosynthetic growing and for hydrodynamic parameters. Therefore, the advanced non-invasive measurement technique Radioactive Particle Tracking RPT will plug this hiatus. This present study investigates the flow features in the 5.5-inch (0.14m) inner diameter Plexiglas split photobioreactor for air-green algae (Scenedesmus) system. Moreover, seeks to examine the impact of algae growth rate on the three-dimensional liquid velocity field and turbulent parameters (Reynolds stresses, turbulent kinetic energy, and turbulent eddy diffusivities) at different superficial gas velocities (1, 2, and 3 cm/sec). The experimental results will provide benchmark data for simulation, design, scale-up, and performance calculation of split photobioreactor. The experimental results and conclusions will present at the conference.
        Speaker: Mr Laith Sabri (Chemical Engineering and Biochemical Engineering Department Missouri University of Science and Technology, Rolla, MO 65409-1230. United States of America)
      • 76
        Flow Regime Identification in a Co-Current Gas-Liquid Upflow Moving Packed Beds Reactor Using Gamma Ray Densitometry
        In industries, upflow moving packed bed reactors are widely used as guard reactor to residual desulfurization unit (RDS). Efficient working of these reactors has a huge impact regarding efficiency and product quality from RDS units. Identification of flow regimes is one of the important aspects of design, scale up, predictive model and reactor performance. Flow regime identification in this reactor was studied using gamma-ray densitometry (GRD). GRD is an important noninvasive measurement technique and flow identification can be determined by on-line monitoring. Time domain, frequency domain, and state space or chaotic methods are employed on photon count time series of GRD to determine flow regime. Time domain analysis includes determination of Standard Deviation, Mean, and Variance. Frequency domain analysis includes power spectrum and wavelet analysis. Chaotic analyses include determination of Kolmogorov entropy (KE). All analysis are done using in-house developed programs. GRD experiments were performed on a lab scale upflow packed bed reactor built by scaling down the industrial reactor. The lab scale reactor is Plexiglas column of 11” I.D and 30” height, and it is packed randomly with 3mm diameter catalyst till 24” height. Various axial and radial position are selected to conduct GRD scanning. The selected test location covers the bottom, middle and top of the packed bed. The measurements are conducted at superficial liquid (water) velocity 0.017 cm/s and superficial gas (air) velocity in the range of 0.6-7.7 cm/s. All analysis showed similar flow regime trend. When compared with flow regime map for upflow packed bed, the results indicate bubbly and pulse flow are the main regimes under this operating conditions. In this presentation, results and findings are discussed.
        Speaker: Mr Ali Toukan (Chemical Engineering and Biochemical Engineering Department Missouri University of Science and Technology, Rolla, MO 65409-1230. United States of America)
      • 15:55
        Discussion
    • 16:15
      Coffee break
    • A07: Advances in Radiation Chemistry Research II IAEA Board Room B/M1

      IAEA Board Room B/M1

      Conveners: Ms Sara Goldstein (Hebrew University), TSec Agnes Safrany
      • 77
        The Radiation Chemistry of Organized Systems: Basic Studies and Implications
        The development of new approaches to radiation stabilization and radiation processing in various fields should be essentially based on consideration of the efficiency and spatial selectivity of the radiation-induced events in complex molecular systems and polymers. In fact, as shown in a number of recent studies, the radiation chemistry of such systems may be controlled by rather subtle effects, e.g., molecular packing determined by relatively weak interactions, conformation, supramolecular structure, dynamics on interfaces, etc. It implies that, in addition to understanding of the radiation-chemical processes at the molecular level, one should consider the effect of system organization on the primary radiation-induced processes and kinetics of post-irradiation reactions. This lecture will present an overview of modern concept of the radiation chemistry of organized systems and illustrate its basic aspects and implications with the results on different systems (from the simplest intermolecular complexes to nanocompsites) obtained in our laboratory during the past decade. Experimental characterization of the radiation-induced effects and structural changes was carried out using various methods, including EPR, UV/VIS, and FTIR spectroscopy, TEM and XRD analysis and complemented by theoretical simulations, when applicable. The illustrative examples briefly covered in this lecture will include (i) radiation-chemical transformations of frozen intermolecular complexes; (ii) specific features of the radiation-driven processes in room-temperature ionic liquids (RTIL); (iii) mechanism of the radiation-induced degradation of crown-ether based systems. Particular attention will be paid to nanostructured systems. A new method of controlled single-stage radiation-chemical synthesis of metal-polymer nanocomposites from the interrpoyelectrolyte complex films developed in our laboratory will be presented. This method makes it possible to obtain the composite films containing metallic or bimetallic nanoparticles with various size distribution and spatial organization using X-rays or fast electron beams. The results obtained with X-ray irradiation of nanostructured systems demonstrated a prominent effect of “radiation-chemical contrast” with possible applications for selective modification of nanocomposites and targeted sensitization (e.g., in radiotherapy). Finally, the implications of the radiation chemistry of organized systems for various existing and emerging technologies (ranging from nuclear waste treatment to fabrication of new nanomaterials and nanolithography) will be outlined.
        Speaker: Mr Vladimir Feldman (Lomonosov Moscow State University, Department of Chemistry, Russian Federation)
      • 78
        Interfacial Radiation Chemistry in Nuclear Technology
        Radiation effects on materials constitute a unique and often crucial feature in the nuclear industry. The effects can be either direct, due to radiation energy deposition in the material, or indirect, due radiation energy deposition in the surrounding media subsequently transferred to the material via chemical reactions. In the majority of nuclear technological systems such as nuclear reactors, fuel reprocessing plants and geological repositories for used nuclear fuel, the surrounding medium exposed to ionizing radiation is water. This is one of the reasons why the radiation chemistry of aqueous solutions has been studied so extensively. However, even though processes occurring in aqueous solutions are extremely important, the most crucial processes from a practical point of view are those occurring at the interface between the aqueous phase and solid materials as these can strongly influence the performance and the integrity of the facility. Of particular concern are corrosion processes induced by oxidative radiolysis products. In most cases the solid material of relevance is metallic or ceramic (primarily UO2 in nuclear fuel). Hence, the surface of the material is an oxide. It has been reported that the yields (G-values) of the radiolysis products can change significantly in the vicinity of oxide surfaces. The rationale for this phenomenon is still debated. In addition, oxide surfaces have been shown to catalyze several reactions involving the molecular aqueous radiolysis products (H2, H2O2 and O2). Consequently, it is of utmost importance to gain fundamental understanding of the radiation driven processes of interfacial systems. In this paper, interfacial radiation chemistry will be discussed in general and the reactions of molecular radiolysis products catalyzed by oxide surfaces in more detail. The oxide materials that have been studied are UO2, Cu2O and CuO of relevance in geological repositories for spent nuclear fuel according to the KBS-3 concept (copper coated canister), ZrO2 of relevance in nuclear reactors (fuel cladding) and numerous other oxides that were mainly studied in order to understand the influence of fundamental oxide properties on the catalytic properties of the surface. The experiments show that the catalytic decomposition of H2O2 yielding O2 and H2O as final products proceed via the intermediate formation of surface bound hydroxyl radicals. This process is catalyzed by most oxide surfaces. For irradiated systems it is also obvious that radiolytically formed hydroxyl radicals adsorb to oxide surfaces present in the aqueous phase. Specific studies of metallic Copper in water have shown that Copper irradiated in anoxic aqueous solution undergoes significant corrosion and takes up more hydrogen than Copper exposed only to water during the same period. Other experiments reveal that H2 and O2 produce H2O2 at room temperature in aqueous solution containing oxide surfaces. In conclusion, oxide surfaces catalyze a number of reactions that are usually not accounted for in homogeneous aqueous radiation chemistry. The molecular radiolysis products yield surface bound radicals of unknown stability. To fully understand present and future systems of relevance in nuclear technology, we must strengthen our knowledge in interfacial radiation chemistry.
        Speaker: Mr Mats Jonsson (KTH Royal Institute of Technology, Sweden)
      • 79
        Radiation Sterilization of Devices and Scaffolds for Tissue Engineering
        A sterile medical device is one that is free of viable microorganisms. This can be achieved through: a terminal sterilization process, sterilization of some components, a combination of chemical/physical sterilization and aseptic processing. The choice of a sterilization process and the Sterility Assurance Level (SAL) should be addressed early in the development of the product and process design requirements in conformance with an integrated quality and risk assessment management system. For radiation sterilization, many standards are proposed to validate the process, and the substantiation of this sterile claim over time is through the dose audit process. For the sterilization of all medical devices the most rigorous SAL (10-6SAL) should be selected and used based upon the ability of the product to function after it undergoes the sterilization process. But, many of the proposed scaffold materials do not withstand high doses to reach a 10-6SAL; so a lower SAL should be investigated on a risk based assessment, that involved the following criteria according the pretended use: Products intended to come into contact with breached skin or compromised tissue; Invasive products that enter normally sterile tissue; Products with claims of sterile fluid pathways; Surgically implanted devices; Products not intended to come into contact with breached skin or compromised tissue; Topical products that contact intact skin or mucous membranes; among others. Sterilization by irradiation has shown a strong applicability for a wide range of products, such as single-use medical devices, tissue-based devices, combination devices, implantable devices and pharmaceuticals. Most of them are sensitive products, but, due to the new standards approaches, radiation sterilization has proven itself to be an effective and flexible method as indicated by its acceptance in the different pharmacopeias and sanitary authorities.
        Speaker: Ms Celina Horak (Comisión Nacional de Energía Atómica, Argentina)
      • 80
        Effect of Sterilization by Gamma-Irradiation on Biocompatibility of Starch-Based Polymers and Composites Suitable for Stem Cell Growth
        Studies with biodegradable starch-based polymers have recently demonstrated that these materials have a wide range of properties, which make them suitable for use in several biomedical applications, ranging from bone plates and screws to drug delivery carriers and tissue engineering scaffolds. A novel non-toxic biodegradable starch based polymer was developed for use in tissue engineering applications. The starch and its blends consisted of: 100 % starch, starch mixed with 10 % cellulose acetate & 10 % acrylic acid & 5 % carboxy methyle cellulose and starch mixed with 10 % cellulose acetate & 10 % carboxy methyle cellulose. Scaffolds were sterilized by ionizing radiation and cells were allowed to grow on the designed scaffolds. Biocompatibility evaluation of such blends was carried out using Hep-2 cells, which were cultured in direct contact with the different starch blends for 72 hours and observed in light and scanning electron microscopy (SEM). Viability was assessed using the light microscope, DNA content, nitric oxide content, lipid perocidation and MTT assay. Also, the effect of low level laser energy (LLLI) on enhancing the proliferation of cells on such scaffolds, were examined , where cells were exposed to He:Ne laser at doses 1, 2.5 and 5 J/cm2 every daily for a duration of two days. Both types of starch-based polymers exhibit biocompatibility that can allow for their use as biomaterials. Starch mixed with 10 % cellulose acetate & 10 % carboxy methyle cellulose.blends were found to be the less cytotoxic for the tested cell line, although cells adhere better to starch cellulose acetate surface. Exposure to 2 J/cm2 He:Ne laser greatly enhanced cell proliferation on all of the given scaffolds.
        Speaker: Ms Soheir Korraa (National Center for Radiation Research and Technology - Egyptian Atomic Energy Authority, Egypt)
      • 81
        Radiation Chemical Studies Leading to the Development of Selenium Radioprotectors
        Radiation chemistry, a discipline involving study of chemical changes induced by ionising radiation, has been the subject of interest for both researchers and technologists. Extensive research carried over the last few decades has translated into applications in the areas of advanced materials, nuclear fuel cycle, radiotherapy, sterilisation, waste treatment, water purification etc. Radiation chemistry of water as one of the important areas of research, provided understanding of the primary processes of water radiolysis, the same has also led to the progress of another related field, radiation biology. Hydroxyl (•OH) radical, a powerful oxidant generated during water radiolysis triggers sequence of events in the living cells causing several changes including mutations in DNA and cell death. While this formed the basis of radiotherapy for cancer treatment, the same became a matter of concern due to unwanted normal tissue radiation damage. In order to minimise this unwanted radiation damage to the normal tissue, radioprotectors are employed. Search for radioprotectors began from Second World War and after screening several thousands of natural and synthetic sulphur compounds, only one compound, amino thiol known as, “amifostine” has been approved in the clinic. Our recent experience in the research area of radiation chemistry of selenium compounds, prompted us to find a new direction of developing radioprotectors from organoselenium compounds. Selenium as a member of chalcogen group shares similarities with sulphur and is a micronutrient and a constituent of redox active selenoenzymes like glutathione peroxidise. A number of selenium compounds such as selenoethers, diselenides, monoselenides have been synthesised and screened for radioprotection. Since •OH radical reaction is the primary process in radiation damage, the reactions of selenium compounds with •OH radical were studied in real time scales. For these studies, pulse radiolysis, a time resolved linear electron accelerator based technique, used to follow chemical reactions in nanoseconds, was employed. The results indicated that in these compounds, selenium is the active centre for the attack of •OH radical and the reaction leads to formation of selenium centred radical cation, which interacts with the nearby hetero atoms through non-bonding interactions. Depending on the strength of interactions, the radical actions are converted to oxidised products, which played a crucial role in deciding whether the selenium compound can be explored as a radioprotector or not. Similar studies on several substituted selenocarboxylic acid derivatives suggested that a diselenide having propinoic acid substitution is structurally best suited for developing as radioprotector. Accordingly diselenodipropionic acid examined in vivo systems was found to be a good organ specific radioprotector. Some of these results will be presented in the lecture.
        Speaker: Ms Indira Priyadarsini Kavirayani (Bhabha Atomic Research Centre, Mumbai-400085, India)
      • 82
        The International Atomic Energy Agency (IAEA) Research on Radiation Sterilization in Tissue Banking
        IAEA program on radiation and tissue banking is a major effort to establish and improve tissue banks in Member States (MS). It was originated in 1971 and became supported by IAEA’s Department of Technical cooperation in 1982. Until now, there are a number of running projects in this area coordinated by the Agency. Less known is that, apart from capacity building by the TC, IAEA’s Department of Nuclear Sciences and Applications carried out Adaptive Research and Development projects related to tissue sterilisation. These two directions of work reinforce each other and result in better Tissue Banking services in MSs. IAEA Coordinated Research Project (CRP) E31006 on “Safety and optimisation of radiation sterilization in tissue banking: Studies on functional properties of irradiated tissue grafts” was started in 2010 and completed in 2015. 16 organisations, represented by Chief Scientific Investigators: Paulina Maria Estela Aguirre Herrera (CHI), Dr Emma Castro Gamero (PER), Mark Forwood (AUS), Clara Linda Guerrero (COL), Marisa Herson (AUS), Eulogia Kairiyama (ARG), Artur Marek Kaminski (POL), Astrid Ann Lobo Gajwala (IND), Jan Koller (SLO), Menkher Manjas (INS), Monica Beatriz Mathor and Wilson Aparecido Calvo (BRA), Peter Myint (UK), Isabel Maria Otero Abreu (CUB), María del Carmen Salidas Farinella (URU), Suzina Sheikh Ab. Hamid (MAL), Sven Scheffler (GFR) contributed to this project. The use of tissue allografts in surgical procedures has increased tremendously over the last two decades. Radiation has been used to sterilize tissue allografts on a large scale. Controversies exist regarding the optimal dosage required since radiation may also compromise tissue allograft integrity and/or its biological function. Tissue banks use radiation doses just based on empirical and/or historical data, or use a fixed dose of 15 or 25 kGy for all tissue allografts. Moreover, radiation conditions differ very strongly from institute to institute which may strongly influence the efficacy of the radiation treatment. In order to improve the knowledge on radiosterilization of tissue allografts “new” and additional studies were designed and conducted under controlled and validated conditions. This “new knowledge” will lead to an optimization of the radiation sterilization process/procedures. Five main categories of research topics were studied: Bone, Demineralized bone, Cartilage allograft, Skin and Amnion. Bone: Adoption of sterilization doses below 15 kGy improves tissue quality and surgical outcomes. Demineralized bone (DMB): Sufficient Osteo-induction was observed after experiments using DBM treated at 15 kGy radiation dose. Cartilage: The present studies demonstrated that Optical Coherence Tomography (OCT) is a suitable non-destructive technique to evaluate the changes in costal cartilage after sterilisation by ionizing radiation. Skin: Most sensitive tissue to structural changes induced by radiation proved to be animal skin, least sensitive human skin. Irradiation dose up to 25kGy had minor impact on the ultrastructure of the irradiated skin and its functionality (evaporation index). It can be concluded that since 2010 significant progress has been made by the participating tissue banks/institutes leading to the production of safer allografts both with respect to its functionality and sterility.
        Speaker: Mr Oleg Belyakov (International Atomic Energy Agency (IAEA), Vienna, Austria)
    • B07: Radiotracers for Energy of the Future II Conference Room M2

      Conference Room M2

      Conveners: Mr Quang Nguyen Huu, TSec Patrick Brisset
      • 83
        Simulation and Optimization of a Neutron Backscattering Analysis Set-Up Using MCNP5 Code
        A neutron back scattering set-up for analysis of hydrogenous sample materials has been simulated using MCNP5 neutron and photon transport code. The set-up is mainly composed of an Am-Be neutron source of 37.2GBq and a He-3 neutron gas detector which are embedded in polyethylene bloc, the latter acting as a reflector. The modelisation used in the simulation was validated comparing thermal neutron flux calculated values with measured ones using indium activation foils and He-3 neutron detector. Then, calculations were carried out to determine optimal dimensions of the reflector and the sample holder with the constraint that the neutron and gamma doses must be at acceptable levels. We have also studied the response of the set-up for other reflector materials such as wax and Perspex. Finally, the analysis of organic samples was simulated and the calibration curves were determined for hydrogen and (C+O/H) ratio. The simulated calibration curves were then compared with those experimentally determined
        Speaker: Mr Zahir IDIRI (Centre de Recherche Nucleaire d'Alger, 02 Bd Frantz Fanon, BP399, Alger-Gare, Algeria)
      • 84
        RPT Study on a Vertical Impeller Mixer
        Radiotracer techniques have been widely applied in various fields of industry in order to diagnose plant processes during operation. This is possible because radioisotopes can selectively label certain process media and represent their movements. Recently, radioisotopes have been successfully used as tracers in the investigations for clarifiers and digesters in wastewater treatment plants. Quantitative information about the performance and flow patterns of digesters and clarifiers were obtained without posing any disturbance to the systems themselves. More recently, studies were conducted to show the feasibility of radiotracer techniques in investigating the particle velocity in fluidized bed reactors compared with the techniques based on optical fibre probes and borescopic particle image velocimetry $[1]$. It has been well described that radioisotope technologies are somewhat superior to others in terms of the limitations in the measurements caused by the signal cross-correlation and minimum measurable flow velocity and vertical angle. CFD simulations on a digester with an internal airlift loop were performed to study the influence of the geometric design on the flow pattern, location of circulation and stagnant regions, liquid velocity profiles, and volume of dead zones, and are subsequently compared with experimental data obtained by radioactive particle tracking $[2]$. CFD simulations must be developed for individual situations because multiphase systems have very complicated physics and are difficult to fully understand. Once the CFD predictions are validated with experimental measurement data, the predicted hydrodynamic parameters can be quantified and used in the design selection and optimization of systems $[3]$. A vertical impeller devised to move up and down along the axis of a cylindrical digester is believed to generate a mixing flow inside, saving the energy for operating the process since the downward movement can be accomplished with the gravitational force. However, the flow pattern and mixing characteristics as a function of the operation parameters of the vertical impeller have not been investigated. In a preliminary study, a radiotracer experiment was carried out for a pilot-scale digester equipped with a vertical impeller. Unfortunately, tomographic measurements that can reveal the flow in 2-dimensions cannot be applied due to the size of the digester. The flow was roughly guessed from the data collected from radiation probes installed inside the digester. In the present paper, as a subsequent study, a smaller lab-scale digester was built for further tomographic investigations. Radiotracers were injected into it for SPECT and RPT studies that provide local information on the flow and multidimensional visual images. $[1]$ S. Tebianian, *et al.*, Chem. Eng. Sci., **127**, 310–322 (2015).\ $[2]$ M. S. Vesvikar and M. Al-Dahhan, Biotechnol. Bioeng., **89**, 719–732 (2005).\ $[3]$ S.-H. Jung, *et al.*, Appl. Rad. Isotop., **70**, 2471–2477 (2012).\
        Speaker: Mr Sung-Hee Jung (Korea Atomic Energy Research Institute, Korea, Republic of)
      • 85
        Linear Attenuation Coefficients and Gas holdup Distributions of Bubble Column with Vertical Internal Bundle for FT Synthesis
        Linear attenuation coefficient distribution, time-averaged cross-sectional gas holdup distribution, and their radial profiles have been measured in 6'' (152 mm) Plexiglas bubble columns with and without internals for the air -water system at a superficial gas velocity 45 cm/s by utilizing a gamma-ray computed tomography (CT) technique. 1" (25.5 mm) diameter Plexiglas internals covers 25% of total cross-sectional of the column have been equipped with the column and similar to those using for Fischer-Tropsch (FT) synthesis. The experimental results revealed that the reference scan significantly affects the values of the linear attenuation coefficients and consequently the gas holdup distribution images. The results show that using air (no column) as a reference scan, enhances the accuracy of linear attenuation coefficients and hence the precision of gas holdup results, while using the empty column with internals as a reference scan gives incorrect values for linear attenuation coefficients and gas holdup values. Moreover, using air (no column) as a reference scan had eliminated the error in gas holdup profiles in the wall region. Furthermore, the CT scan images exhibit symmetric gas holdup distributions for bubble columns with and without internals as studied for the superficial gas velocity. Finally, the gamma-ray computed tomography technique was capable of capturing the wall thickness of a column and position of each internal when air (no column) is used as reference scan.
        Speaker: Mr Abbas Sultan (Chemical Engineering and Biochemical Engineering Department Missouri University of Science and Technology, Rolla, MO 65409-1230. United States of America)
      • 86
        Numerical Simulation of Measurement by Gamma Ray Scanning of Coke Deposition in Packed Bad of Distillation Column
        In distilation column, the packed column for gas-liquid contacting are used extensively for absorption, stripping and distillation operations. One of principal troubleshooting encountered in the operation packed bed is the coke disposition which is related process condition and structural problems. As the gamma scanning technique is an adequate to define on-line troubleshooting, in the present study, we try to define by Monte carlo numerical simulations the minimum rate of coke deposition in the packed bed that can be revealed by this technique. Such information, permit to assist engineers in troubleshooting process problems, optimize production and minimize plant down time. A simple packed bed geometry was reproduced in the numerical model, with a differents coke deposition rates. The preliminary simulation results show that it is possible to detect coke deposition for coke occupation volume higher than 7.3% compared to the packed bed total volume. In the the second part in this work will be dedicated to define an optimal cofiguration of gamma scaning to provide accurate measurement of coke deposition rate taking into account the coke
        Speaker: Mr Rachad ALAMI (National Center of Energy Science and Nuclear Techniques, Morocco)
      • 87
        Noninvasive Radiation Based Densitometry and Velocimetric Monitoring of Fluidization of Coal and Bottom Ash Mixtures
        Utilization of noninvasive radiation based techniques has become widespread in several industrial applications. Of particular importance is its deployment in systems involving two or more phases. Such systems are ubiquitously found in areas concerning from the processing of fuels and chemicals to the production of feed, food, pharmaceuticals, and specialty materials. In spite of extensive presence of multiphase systems, lack of knowledge on complex local flow structure have rendered non-availability of any single established methodology for their design. Nonetheless, two classes of radiation based measurements – tomographic and velocimetry (commonly referred to Radioactive Particle Tracking) have emerged as attractive strategies for providing dynamic information on phase distribution and flow pattern of phases of interest respectively. In this work application of such measurement techniques are being reported for fluidization of coal and bottom ash mixtures. The talk will present details of this work and how radiation based non-invasive tool proves to be a great benefit in fundamental analysis, design and scale-up of coal fluidized bed gasifiers.
        Speaker: Mr Shantanu Roy (Indian Institute of Technology - Delhi, India)
      • 88
        Experimental Study of Pebble Flow Dynamics in a PBMR Using RPT
        The pebble bed modular reactor (PBMR) is a type of 4th generation nuclear reactor. In a pebble bed reactor, nuclear fuel is in the form of spherical pebble and moves slowly inside the core of the reactor under the influence of gravity. A coolant gas moves through the voids formed in between the pebbles and removes fission heat generated from the nuclear fuel. Multiphase Reactors and Applications Laboratory (mREAL) at Missouri S&T has designed, developed, and tested a scaled down continuous pebble re-circulation experimental set-up, mimicking the flow of pebbles in a PBMR. An experimental study of pebble flow dynamics in a cold flow setup was carried out using a radioactive particle tracking (RPT) technique that used a cobalt-60 based tracer to mimic pebbles regarding shape, size, and density in a non-invasive way. The RPT technique is capable of providing a full description of the 3-D flow field in highly dense and opaque reactors. Obtained results of the Radioactive Particle Tracking technique regarding Lagrangian trajectories, residence time distributions, velocity field, etc. are a valuable benchmark data for an assessment of the contact force model used in the Discrete Element Method (DEM) based simulations.
        Speaker: Mr Vaibhav Khane (Chemical Engineering and Biochemical Engineering Department Missouri University of Science and Technology, Rolla, MO 65409-1230. United States of America)
      • 18:00
        Discussion
    • A08: Radiation Sources and Facilities - panel discussion IAEA Board Room B/M1

      IAEA Board Room B/M1

      Conveners: Mr Suresh Pillai (National Center for Electron Beam Research), TSec Sunil Sabharwal
      • 89
        Review of the two New Rhodotron Accelerators: The Compact 10 MeV TT50 and the High Energy 40 MeV Rhodotron
        Emerging applications drive development of new innovative accelerators. IBA is currently developing two new accelerators. The first new accelerator is a compact Electron beam accelerator called the TT50 allowing to produce beam up to 10 MeV. This accelerators is perfectly suited for industries sensitive to cost such as cargo screening, medical device sterilization or applications requiring mobile systems. The second new product under development is a high energy Rhodotron able to reach 40 MeV and 125 kW of beam power. These specifications makes Mo-99 production using particle accelerators very competitive. Development status, innovations and target performances will be reviewed.
        Speaker: Mr Philippe Dethier (IBA, Belguim)
      • 90
        A Billion Curies and Counting: Ensuring Cobalt-60 Supply and Disposal for Decades to Come
        Nordion has been a leader in the production of Cobalt-60, used for prevention and treatment of disease, since the inception of the technology in the 1950s. This product has become a critical component of healthcare, impacting the daily lives of millions of people around the world. Since the production of the first C-188 Cobalt-60 source in 1964, Nordion has shipped more than one billion curies of Cobalt for use by the gamma processing industry. During this 50 year period, there have been significant changes in technology, regulation and the global supply chain. Our approach to managing the full lifecycle of the C-188, from sourcing to production to transportation to disposal, has allowed us to adapt to these changes and continue to provide a reliable supply of Cobalt to a global customer base Today, we face a changing reactor landscape and new industry dynamics that offer both challenges and opportunities. Our Extend, Expand, Develop strategy is aimed at exploring a wide array of possibilities for strengthening the supply chain for the coming decades. We now have more than 20 active projects under way, from the development of new technology platforms to enhancement of existing partnerships, as well as the creation of new ones. We also continue to make use of established paths for disposal of spent sources, while pursuing other solutions in order to provide the best options for the industry. This presentation will describe the evolving industry landscape as we see it, and provide an update on Nordion’s efforts and successes around securing supply of Cobalt-60 and managing the complete lifecycle for the long term.
        Speaker: Mr Richard Wiens (Nordion Inc., Canada)
      • 91
        How to Apply Radiation Technology for Pollution Control
        Since 1980's radiation technology has been introduced to pollution control, over the past few decades, this technology has been developed aimed at ensuring the safety of gaseous and liquid effluents discharged to the environment. It has been demonstrated that flue gas treatment (SOx and NOx removal), wastewater purification and sludge hygienization by radiation can be effectively deployed to mitigate environmental degradation. Even they showed promising results through the operation of several pilot scale plants and industrial scale implementation, however, the technology was boggled and it needs to achieve a breakthrough. There are several drags to implement larger scale applications. Not like other industrial applications, the environmental plant should operate all the year round without stopping. Once it stops, the waste (stack gas or wastewater) will discharge without any treatment, and the stand-by system costs too much. Thus, technical upgrades to manage the plants in such cases are required. Radiation technology, like other technologies, also has strong completion in market with conventional pollution treatment technologies. And hence, it is necessary to decrease the capital cost with the operating cost to have competitiveness in waste treatment cost. Nowadays, the radiation processing equipments are getting more powerful and reliable, and ready to apply for pollution control, but required a systematic operation for preventing the shutdown of entire plant. To avoid the tough competition, it is better to find the niche applications that the radiation technology can do better, such as removal of EDCs and pharmaceutical residues in domestic wastes, VOCs removals from industries, sludge hygienation. Computational methods, mobile e-beam and other eeffective ways to confirm the laboratory result will help for easy scaling up to industrial implementation.
        Speaker: Mr Bumsoo HAN (EB TECH Co., Ltd., Korea, Republic of)
      • 92
        ILU Industrial Electron Accelerators
        ILU electron accelerators designed and produced in Budker Institute of Nuclear Physics are working in industry and in research organizations. ILU-8 and ILU-10 machines have single-cell cavities, their maximum energies are 1 MeV and 5 MeV, maximum beam powers are 20 kW and 50 kW respectively. The recently developed ILU-12 and ILU14 machines have multi-cavity accelerating structures, their energy ranges are 5-7,5 MeV and 7,5-10 MeV, maximum beam power of ILU-14 is 100 kW. Radio frequency (RF) generators of the ILU machines are based on pulse vacuum triodes. Compact accelerator ILU-8 with energy up to 1 MeV is using mainly for wire irradiation, it has local radiation shield. All other ILU accelerators can be supplied with X-ray converters and can work in X-ray generation mode. Powerful ILU accelerator are using for wires, cables and pipes modification as well as for medical device sterilization and food irradiation.
        Speaker: Mr Aleksandr Bryazgin (Budker Institute of Nuclear Physics, Russian Federation)
      • 93
        EB Technology vis-a-vis Gamma Radiation for Irradiation Sterilization: Emerging Scenario
        The irradiation sterilization as a green and safety sterilization method is widely used in the treatment of food, medical products, herbals and agricultural products in the worldwide. The main technologies for irradiation sterilization are Gamma radiation and Electron beam technology which includes EB and X-ray. Co-60 based technology was developed more than half century, but following the continuous concerns on the radiation safety, nuclear security, the radioactive waste and the supply of Co-60 sources, the development of Gamma radiation for irradiation sterilization faces more and more challenges Electron beam based technology was developed relatively much later to Gamma technology. As the need of alternative methods which not use the radioactive material for irradiation sterilization, the EB technology developed very fast in last decade. The presentation provided the general analysis of the advantages and drawbacks on different aspects such as regulation requirement, safety and security, products scope, economically competitive for both gamma and EB technologies and then gave some suggestion and outlook for this emerging scenario of irradiation sterilization.
        Speaker: Mr Wei Peng (Vanform Corporation, China)
      • 94
        Gamma Irradiator Technology: Challenges and Future Prospects
        Gamma irradiator technology has served the bulk irradiation industry very well. Sterilization of medical disposables has been the most popular application followed by irradiation of food and other products. However, it has faced number of challenges in its journey so far. The initial irradiators utilized Cs-137 sealed sources in highly soluble chloride form. Wet storage irradiators had risk of contamination due to Cs-137 sources. There were incidents of irradiator facility and surrounding soil contamination due to source leakage. Availability of Co-60 in metallic form came handy to surmount this challenge. Over-exposure of plant personnel while carrying out maintenance has been reported. With the improvements in safety systems, this challenge was adequately tackled. Later, shortages of Co-60 in addition to high prices coinciding with availability of the challenger linear accelerator technology became the biggest challenge. Higher capital cost in addition to higher running cost of the LINACs was though a deterrent. Also, non-availability of reliable power supply in different parts of the world was an additional factor in accelerators not replacing the gamma irradiators at faster pace. The most recent challenge to gamma irradiator technology has come due to heightened security risk the world is facing now. There are fears being raised regarding security of the high intensity radioactive sources in such irradiators. The security challenge is due to fear of the sources going into wrong hands. This possibly could happen when sources are in installed position or more so during their transportation. Such fears have forced the authorities to strengthen the regulations. Shipping companies have become reluctant to carry radioactive materials, particularly when trans-shipment is involved. There are number of instances of denial of shipments making the situation worse. The maximum activity which can now be carried in a Type B(U) container is also limited to only 30kci of Co-60 whereas the requirements in industrial irradiators is much higher which makes the transportation by air exorbitantly high. The other requirement of regulatory body to obtain guarantee of return of sources to the original supplier is another impediment. To prevent stealing of sources when those are in installed position, hardening of facilities or devices needs to be carried out so that response time for the security agency in case of theft attempt is shorter than what is needed by the adversary to remove the sources from the device and shift those to a makeshift container. Lastly, challenge due to possible dismemberment of installed sources which can result in large areas becoming inaccessible due to contamination is forcing the operators to think hard before making a choice. Accelerator Technology being “ON-OFF”, does not have such drawbacks. Because of this, LINACs have gained much higher importance in recent times. Additionally, LINAC’s lower efficiency of conversion of energy to electromagnetic radiation and its dependence on availability of economic and reliable power supply will eventually decide the time at which it replaces the gamma irradiator technology fully in any particular part of the world.
        Speaker: Mr Anil Kohli (Department of Atomic Energy, India)
    • B08: Seeing the Invisible: Structure Imaging - Safe and Effective Industry I Conference Room M2

      Conference Room M2

      Conveners: Mr Nicholas George Cutmore, TSec Patrick Brisset
      • 95
        Next-Generation Fast-Neutron/X-Ray Scanner for Air Cargo Interrogation
        There is a growing need for improved methods for rapidly inspecting bulk air cargo, the majority of which is currently subjected to no physical inspection or scanning. Fast-neutron/X-ray radiography provides a method to produce images that show the shape, density and composition of objects in cargo. These can be used to identify a wide range of threat materials, including organic substances such as explosives and narcotics that can be hard to resolve using conventional, X-ray only scanning technology. Following initial development and demonstration by CSIRO of a fast-neutron/X-ray scanner at Brisbane Airport in Australia, the technology was commercialised with the Chinese security technology firm Nuctech Company Ltd. First-generation air cargo scanners combining neutron and dual-energy X-ray imaging are operating at airports in the Middle East and China. In this paper, we present the latest technical developments, which have focussed on reducing the footprint, cost and complexity of the technology, whilst improving image quality and performance. We have developed a completely new plastic-scintillator neutron detection system with silicon photomultiplier (SiPM) readout. The low-noise characteristics of SiPMs allow much lower energy neutron interactions to be detected that was possible using our previous photo-diode based readout, increasing detection efficiency for 14 MeV to 30%. The small form-factor and simple signal amplification and processing requirements allow detectors to be tightly packed; the complete detection system includes 1440 elements and has a 5 times higher detection efficiency than the array used in the first-generation scanner. This efficiency has allowed us to significantly decrease the size of the neutron source. The first-generation scanner used a liquid-cooled, deuterium-tritium (DT) neutron generator producing 5×109 n/s to image air-cargo at scan speeds of up to 6 m/s. The latest system uses an air-cooled, laboratory-scale neutron generator with an output of just 3×108 n/s. With advanced image processing, image quality and scan speeds can be maintained despite the reduced neutron output. The smaller generator is also considerably easier to install and maintain in airport environments. We also report on the development of novel, low-cost and compact neutron shielding, that allows a combined neutron/X-ray scanner to be deployed within a footprint similar to that of conventional X-ray only cargo screening systems. Figure 1 shows a typical image of various test and cargo objects, obtained using the first model of the new scanner operating in Nuctech’s factory. Colours indicate material type, with metals in blue, mixed materials, ceramics and glass in green, and organic substances in yellow, orange, red and pink. The scanner was subsequently installed and operated at Beijing International airport, and we report on results of this trial.
        Speaker: Mr Nicholas George Cutmore (Commonwealth Scientific and Industrial Research Organisation (CSIRO), Australia)
      • 96
        Monte Carlo Simulation and Experimental Verification of Blockages in Pipelines Using Gamma-Ray Computed Tomography
        Blockages and material build-up in pipelines are most common problem in many types of process industries, particularly, in petroleum and chemical industries. Partial blockages may impair process plant operation whereas total blockages could lead to a shutdown. Thus, development of non-destructive methods for on-line blockages detection in pipelines is of a prime importance. In this paper, a study on Monte Carlo simulation using Geant4 code package and an experimental work using a newly developed portable gamma-ray computed tomography (CT) system, called “GammaSpider” for detecting blockages in pipeline was conducted. The Geant4 code package provided various features suitable for simulating the geometry and required parameters of GammaSpider, the results were compared and validated by the experimental data and finally mass attenuation map of various materials was reconstructed in 2D or 3D image. Elements to be implemented in the simulation code include a highly collimated incident beam of 662 keV gamma-rays from Cs-137 radioisotope source, the transmitted radiation after traversing through a cross-section of a 20 cm diameter steel pipe containing process water and a simulated partial blockage (concrete deposit) and the transmitted intensity data were recorded by a collimated sodium iodide (NaI) scintillation detector at many different translation steps (projections) and rotation angles (views). The results of Geant4 simulation permits to optimize experimental parameters of the gamma-ray CT system. This will also provide an improvement in the resolution of the reconstructed tomographic images. Results from Geant4 simulation can be used in planning a test for the routine-used of the GammaSpider system.
        Speaker: Ms Haifa Ben Abdelouahed (CNSTN, Tunisia)
      • 97
        Associated Image Processing Algorithm in Dual-Projection Systems
        Methods like single-projection detecting and CT detecting are widely used in radiation scanning systems, however, these methods have shortages such as an inability to differentiate materials and low efficiency so that methods with high accuracy and efficiency are required. In this paper, we introduce a dual-projection radiation detection technique. Two groups of radioactive sources and detectors are fixed to obtain gray-scale images of target objects from two orientations. Algorithms are developed to combine these images and calculate the shape, position, attenuation coefficient and density of target objects rapidly and accurately. Ideally, target objects are assumed as convex polygons of single material. The gray-scale curves follow the ray attenuation theorem which contains physical property information such as attenuation coefficient and density. Inflections on the curve show when vertexes on target objects are scanned. To recover the target object geometry from gray-scale images, algorithms are developed with functions as follows: 1. Locating the position of each inflection on the curves and calculating their coordinates in real space coordinate where the vertexes are. 2. Combining these calculated vertexes to form polygons and remove those that do not meet the mentioned assumptions. 3. The selected polygons are re-projected by emulation. The calculated polygon whose gray-scale curves are closest to the ones of target object is chosen as the result of recovering. And its position, shape and density can also be calculated. Matlab simulations were performed, verifying the feasibility of the algorithms. Given $10$ mm detectors and an arbitrary pentagon target object, the result shows that the relative error of calculated absorption coefficient is $0.33\%$. Realistic experiments with ideal target were performed. Standard aluminium blocks with sections of quadrilateral and pentagon are used as the target. The detectors are $7$ mm in size and the radioactive source is $^{60}$Co. The relative error of calculated density is within $3$–$5$%. The difference between two experiment results of absorption coefficient is $4\times10^{-3}$ which shows the high reproducibility of this system. Further experiments using non-ideal objects were made. A bucket of water was put in a container as the target. By moving the container continuously, a series of gray-scale curves, representing different sections of all things in it, are obtained and processed to recover the shape and position. The results show that the relative error of calculated density is $10.4$% after eliminating the impact of background noise. Details of the method and its application will be presented.
        Speaker: Mr Peng Cong (Institute of Nuclear and New Energy Technology, Tsinghua University; Beijing Key Laboratory on Nuclear Detection and Measurement Technology, China)
      • 98
        Comparison of Image Reconstructions for Gamma Transmission Computed Tomography System by using MATLAB and i-Gorbit Software
        With wide industrial application, computerized tomography CT is rapidly developing technique that is especially useful for imaging and measuring multi-component and multiphase processes. The most important contribution of CT is to greatly improve abilities to distinguish regions with different gamma ray transmittance and to separate over-lying structures. The CT system of single source and detector gamma transmission tomography GORBIT, designed by CANTI, Vietnam, was used to analyze the different density materials. Hardware of the GORBIT CT system consists of two servo motors, data logger, computer, a radiation source and a radiation detector. The measurements in GORBIT system were carried out at the CT Laboratory in Department of Atomic Energy, Yangon. This tomography system operates with a gamma ray source of 60Co1.85 GBq (50 mCi of intensity) and a NaI(Tl) scintillation detector. Measured gamma transmitted data were used to reconstruct the cross-sectional images of research samples. These images were reconstructed from the measured transmitted data in different image reconstructions algorithms. Analytical methods of back projection (BP), the filtered back projection method (FBP) and iterative algorithms of algebraic reconstruction method (ART) and estimation maximizations (EM) methods were used in i-GORBIT image reconstruction software. Another image reconstruction program GCTS was created by using MATLAB package. In this image reconstruction, different algorithms of back projection (BP) and filtered back projection (FBP) were used. In FBP method, different filters of Ram-lack filter, Sheep-Logan, Hamming, Hann and Cosine filter can be chosen and different interpolation methods can be applied to improve the quality of images. The results of different image reconstructions programs were compared and analyzed for the sample materials. In this research work we will present some results obtained by using tomographic techniques to analyze various samples to check the distribution of various density materials. These samples are made by using different properties of materials with high and low density materials of lead, ion, six holes brick, polymer slab contained in a polymer pipe vessel. These samples are also used to verify the outcome from the CT analysis with different image reconstructions programs i-GORBIT and MATLAB. Keywords: Industrial Gamma ray computed tomography, transmission measurement, image reconstruction algorithms, MATLAB, linear attenuation coefficients
        Speaker: Ms Khaing Nyunt Myaing (U Chit Khe, Myanmar)
      • 99
        Gorbit - the Flexible Gamma Computed Tomography System for Pipeline Inspection
        Gamma computed tomography is a non-intrusive technique, which is capable to provide the density based images of structure or phase distribution inside the industrial components without shutting down or disturbing normal operation. However, the field applications pose a lot of challenges to a tomography system which are related to mobility, compatibility to mount on the components, weight and cost of system, etc. GORBIT – a flexible gamma computed tomography system was designed and fabricated for pipeline inspection. The first version of GORBIT was based on the parallel configuration that allows inspection of the pipeline of OD up to 60 cm at any angle, easy installation and mounting on the pipe and automatic scanning. The image resolution can be achieved 16 x 16, 32 x 32, 64 x 64, 128 x 128 and 254 x 254 pixels. The image reconstruction software was also developed based on Filter Back Projection (FBP) and Algebraic Reconstruction Technique (ART) algorithms. The GORBIT system has been deployed to inspect the pipeline of petroleum industry for detection of corrosion, deformation and blockage. GORBIT was also used for in-house experiments to validate the CFD simulation results of fractional phase flows. The new version of GORBIT was recently developed based on the modified 3rd generation using fan beam that reduced significant operation time while maintaining the resolution of image.
        Speaker: Mr The Duy DANG NGUYEN (Centre for Applications of Nuclear Technique in Industry (CANTI), Viet Nam)
      • 10:40
        Discussion
    • 11:00
      Coffee break
    • A09: Preservation of Cultural Heritage IAEA Board Room B/M1

      IAEA Board Room B/M1

      Conveners: Mr Pablo Vasquez (A.S.), TSec Sunil Sabharwal
      • 100
        Disinfection and Consolidation of Archived Materials and Cultural Heritage Artefacts by Radiation Processing Techniques
        Degradation of organic and especially cellulose based heritage is caused by both endogenous and exogenous factors. One of the most common exogenous factor is moisture, and the variation of the equilibrium moisture content of the material can initiate the development of mold in the substrate. Mold not only affects cellulose materials, but is also impacts occupational health and thus should be rendered inactive as soon as possible. Doing nothing is not an option because active mold (even dormant) may deteriorate cellulose based heritage easily, while its wake-up call, i.e., an atmospheric moisture increase, can occur easily. Much work has been performed on the application of $\gamma$-radiation and therefore it is well accepted in, e.g., the food industry and for medical device sterilization. However for cultural heritage application, discussions are still on-going as ionizing radiation may be capable of deteriorating organic materials. Compared to conventional disinfection with chemicals, $\gamma$-radiation can be seen as a clean disinfection method as no harmful volatiles are emitted after the treatment with full effectiveness on deteriorating the mold species. In the past decade, many heritage science research programmes world-wide were dedicated to the application of ionizing radiation for disinfection and conservation. The research varied from optimization of the treatment to understanding of deterioration mechanisms, and in 2012 for the first time, an IAEA supported event was held in São Paulo, Brazil. The IAEA now supports a new research network dedicated to this topic aiming to solve final research gaps and produce well accepted recommendations. This paper reviews not only the state-of-the-art of international developments on the application of ionizing radiation for cultural heritage for both disinfection and conservation, but includes a summary of show-cases. For example, the disinfection of the Library collection of the Peace Palace, the Hague (Netherlands) and conservation of a XVIIIth century parquet, Grenoble (France). Finally a novel book dedicated to the topic of this presentation, supported by the IAEA, shall be introduced.
        Speaker: Mr John Havermans (TNO Environmental Modelling, Sensing and Analysis, Netherlands)
      • 101
        Irradiation Method in the Protection of Cultural Heritage Objects Endagered by Massive Biodegradation
        Cultural heritage artefacts of organic origins are susceptible to deterioration by the action of insects, moulds, fungi and bacteria. The infestation of museum store rooms, collections and sacral places is a serious permanent worldwide problem to the safekeeping of such objects. Protecting cultural heritage objects against biodeterioration becomes especially urgent when provoked by sudden changes of their stable and optimum storage conditions, caused either by natural catastrophes (floods, earthquakes, tempests, etc.) or by human activities (wars, riots, street unrest, etc.). The emergency recovery of many objects in the course of a rescue operations can bring infested and non-infested objects into contact, engendering an abrupt development of pests and endangerment of whole collections. The commonly used methods for suppressing massive biocontamination (capable of fast processing of large numbers of objects), are treatment with poisonous gasses and treatment with ionizing radiation. While the use of ethylene oxide gas is now severely restricted, irradiation has proven an effective physical, noncontact method of preservation, applicable to massive treatment of cultural heritage objects. In its $\sim 50$ years of application to cultural heritage preservation, the irradiation method has most often been used for disinsection, i.e., eradication of insect pests from objects. In the course of safekeeping, massive treatments of entire museum collections during regular and/or urgent maintenance and clean-up procedures provide examples of especially appropriate applications of irradiation method. Likewise, in cases of simultaneous endangerment of many objects by mold, literally for entire collections caught up in catastrophes, the irradiation method has proven to be the method of choice. Professional literature presents some especially successful cases of massive decontamination by irradiation and it will be briefly presented in the lecture. Croatian experience in the field gained at the irradiation facility of the Radiation Chemistry and Dosimetry Laboratory of the Ruđer Bošković Institute in Zagreb during the past 25 years will be illustrated by two groups of examples of successful application of irradiation to the protection of large numbers of cultural heritage objects endangered by massive biocontamination: a) Massive radiation desinsection in the process of maintenance of museum collection and interventive treatment of an entire polychromic altar; b) Radiation treatment in the massive process of rescuing and protecting art objects endangered during the war in Croatia (1991–1995). In co-operation with the Croatian Conservation Institute, one third of evacuated objects, mostly polychromic wooden sculptures, parts of altars and other wooden pieces, comprising almost 1500 complete altars, were irradiated for disinsection, or disinfection by the RBI facility. Besides halting degradation, irradiation was used as the first step of conservation to enable safe object storage without the risk of cross-contamination before final conservation and restoration.
        Speaker: Ms Branka Katušin-Ražem (Ruđer Bošković Institute, Croatia)
      • 102
        Radiation Processing for Cultural Heritage Preservation – Romanian Experience
        Radiation sterilization was taken into consideration as mass decontamination techniques for the bio-degradable cultural heritage (CH) as soon it was spread in the medical field. Earlier experiments showed the advantages and disadvantages, namely “side-effects” on the CH materials. More than 50 years later, the suitability of ionizing radiation treatment for CH items is still under debate. The main reason is that the science and industry where not able to provide yet another mass decontamination technique with higher efficiency and effectiveness. For wood items there is a general agreement that the irradiation dose needed for insect eradication will not produce any damage, even in case of painted wood. For cellulose in paper there is a reduction of the degree of polymerization (DP) at higher doses required for stopping the fungal attack but this should be taken into consideration against the purpose of the treatment. Emergency or salvage treatments are required for mitigation of consequences of accidents or bad storage conditions. In some cases (archives) the value of the written information is higher than the historical value of paper artifact. For other materials (textiles, leather, parchment) there are less published investigations on the effects or ionizing radiation. As a general rule, irradiation is not needed when there a few CH items affected by biological contamination. The conservators and restaurateurs can handle the problem by classical means. The need for irradiation appears when there are large collections (hundreds, thousands or more items) heavily affected by biological attack. Following new literature reports there is a slow increase in the quantities and kinds of irradiated CH items in different countries of the world. In Romania, IRASM gamma irradiator of IFIN-HH is receiving an increasing number of requests for CH irradiation, mainly because an intensive research program on this topic and a close contact with the CH owners or administrators. After more than 10 years of CH irradiation, IRASM facility can advise the CH owners about chousing the irradiation dose and how to evaluate the irradiation side effects (if any). Beside the review of the scientific results obtained in Romania and abroad, this paper is presenting some examples from Romanian experience.
        Speaker: Mr Ioan-Valentin Moise (Horia Hulubei National Institute for R&amp;D in Physics and Nuclear Engineering, Romania)
      • 103
        Development of New Radiation-Curing Monomers-Resins Systems for the Consolidation of Wooden Cultural Heritage Artefacts
        The styrene unsaturated polyester resin is implemented so far by ARC-Nucléart Conservation Centre for the consolidation of degraded wooden artefacts from cultural heritage, following a process so called “Nucléart” by liquid state resin impregnation under vacuum/pressure, and in-situ polymerization of the resin under gamma irradiation. However, this method is irreversible due to the crosslinked solid state resin which is insoluble in any solvent, and moreover, the consolidation of wood by such 100 % reactive resin fills almost completely the wooden pore structure, creating in fact a wood-plastic composite which densities are much higher than untreated wood ones. These features are the drawbacks of the method because in conservation-restoration of art objects, the two well-known criteria among others are the reversibility of the products and the minima intervention in order to avoid the denaturation of the original and unique object. Having proven during many decades its effectiveness for saving from destruction numerous highly degraded artefacts, another drawback of the actual process is the more severe regulation in terms of safety, toxicity when using the styrene monomer, without considering its high vapour pressure and its residue in treated artefacts even after long periods of storage or display. For these different reasons, the aims of our research are the improvement of our radiation method in two directions: the application of already available styrene-free resins, and the development of hydroxyl-acrylic monomers which polymers are in principle reversible, respecting one of the most important criteria in conservation. In this paper, we will describe first the irradiation conditions to overcome the inhibition effect of oxygen on the complete curing of the resin or monomers, the formulations of monomers in order to obtain polymers with the most appropriate Tg (around 40° to 60°C), and their polymerization in selected solvents in order to modulate their content in the wood. Structural characterizations are carried out by using FTIR and solid state NMR spectroscopies. The second part of our work will present the impregnation of two species of wood, beech and fir, by the styrene-free selected resin and by the monomers. They are characterized by various techniques such as colorimetry, dimensional changes, radiography, computerized tomography, and mechanical resistance. Last but not least, the interaction or not of the resins or monomers with various polychromies (pigments, colorants) has to be checked, and it is important to assess the feasibility of their implementation in consolidation of samples of sacrificed artefacts presenting gilded or polychrome surface layers.
        Speaker: Mr Quoc Khoi TRAN (CEA ARC-Nucléart, France)
      • 104
        Application of Ionizing Radiation for Cultural Heritage
        Ionizing radiation has specific and indisputable advantages over classical procedures for conservation and preservation in Cultural Heritage, such as no risk for the operators, no toxic residues and hence no risks for curators, visitors or the environment. This technology can replace the traditionally used toxic or carcinogenic gases such methyl bromide or ethylene oxide, eliminating the associated health problems and environmental pollution. Large amount of bio-deteriorated objects can be treated in a short time with excellent reliability, using controlled and codified procedures. The evaluation of the often not reversible physical-chemical modification induced by ionizing radiation on treated materials, namely side-effects, represent an important goal to guarantee the safeguard of the artifacts and the reliable diffusion of this technology. Irradiation procedures and characterization methodologies will be assessed for the conservation and preservation of archives materials and for the consolidation and protection of porous artefacts. Defined irradiation conditions (in term of irradiation dose and dose rate, environmental atmosphere, pre-treatment of the cultural heritage object) and the proposal of shared guidelines are extremely desirable. The ENEA activities regarding the application of ionizing radiation in Cultural Heritage performed at Calliope plant are focused on conservation and preservation (bio-deteriogen eradication in archived materials) and on consolidation and protection (degraded wooden and stone porous artefacts consolidation). The biocide effect of gamma radiation has been confirmed on selected papery materials at dose effective for the treatment and the harmful effects on the irradiated materials have been demonstrated. With the aim to be effective for disinfestation, microbiological studies about the dose rate and atmosphere (air and inert gas) effects on gamma irradiated archived materials have been performed. Irradiation side-effects on paper have been also investigated by chemical and spectroscopic techniques (DP, FTIR, ESR). Different atmospheric and biological agents induce severe and somewhat irreversible degradation phenomena on wooden or stone artefacts (i.e. porous materials). Consolidation and surface protection of these degraded objects is usually obtained by the application of natural or synthetic consolidating agents but the penetration inside the porous material it rather difficult, limiting the effectiveness of the treatment. Impregnation of cultural artefact with a diluted solution of consolidant precursors (i.e. low-sizes monomers or oligomers) followed by radiation induced in situ polymerization represents a very promising solution to achieve actual bulk strengthening. Formulation of different polymeric composition for the consolidating agents to improve their strengthening efficacy and safeguard towards the cultural object has been investigated, modifying their features by gamma irradiation and aiming to increase their functional, chemical and time stability. Particular attention has been paid on the solvent compatibility, aiming at employing environmental friendly and not harmful to the health substances. Characterisation by means of different techniques (optical measurements, FTIR, ESR, NMR, mechanical tests) has been carried out to evaluate side-effects and the post-irradiation behavior. Standardisation of irradiation procedures and methodologies by a correct choose of irradiation parameters and their reliability and reproducibility has been verified and supported by dosimetric measurements.
        Speaker: Ms Alessia Cemmi (ENEA, Italy)
      • 105
        Uses and Prospects in $\gamma$-Biocide Treatments for Cultural Heritage
        Biocide treatment by $\gamma$-irradiation for wooden and archival items has been proposed more than $50$ years ago, but, despite some resounding success and a demonstrated real efficiency, it is still of limited uses for heritage conservation. Indeed, if such denoted “nuclear” process can scare the less scientific public, more rational reluctance due to fear of negative effects induced by ionization in irradiated material have been expressed. Despite such, secondary effects are usually insignificant or very low, $\gamma$ irradiation has been (and is still) often understood by many curators as resulting in a strong and irreversible degradation, comparable to well-known ultraviolet exposure ageing. Of course, as with any process in which we ask to be active—in this case to kill biodegrading species—it is impossible to ask for absolute harmlessness. Any biocide process, as innovative or not as it is, can be problematic. Anoxia is known to induce colour changes of some dyes. Ethylene oxide, not only being very dangerous, is very reactive. Temperature treatments can cause mechanical tensions and so on. In choosing between different ways to manage pest infestation, curators have to evaluate a balance between benefits and drawbacks, selecting the best compromise regarding the conservation issue (including the benefits and drawbacks of “doing nothing”). In this context, advantages of the $\gamma$ irradiation are various. Beyond its proven effectiveness on any kind of living organism, whatever the life stage, this contactless technology meets very well the concept of minimum intervention, being able to insure the required successful conservation with very low impact, only “changing as much as necessary but as little as possible”. The ability to treat by mass, even through packaging, and the absence of other associated heat effect or residue in processed materials are two other desired qualities. But it is definitively its reliability, besides its efficiency, which distinguishes $\gamma$ irradiation, thanks to $\gamma$ penetrating power and the facility to ensure that biocidal conditions are achieved everywhere in the volume. In the other hand, possible secondary effects need to be evaluated carefully. Material behaviour under irradiation is studied in the field of heritage, as well as it is widely investigated in many areas (nuclear, space, medical, etc.). Effects depend largely on the type of material and on the absorbed dose. Very few materials are known to be incompatible with $\gamma$-irradiation biocide treatment. The possible interaction with informative properties of patrimonial goods (DNA information, dating parameters) is another relevant issue. ARC-Nucléart, Grenoble, France, makes use of $\gamma$ irradiation for more than $45$ years for cultural heritage. While insects are most often targeted, mass treatment of fungal species contaminated collections are more and more demanded. It seems that during the last $10$ or $15$ years, it is also increasingly used around the world. We will give an overview of the latest developments of this technique, both in actual use in France, and in the studies that are ongoing to quantify so-called secondary effects.
        Speaker: Mr Laurent Cortella (ARC-Nucléart CEA Grenoble, France)
    • B09: Radiotracer for Managing Natural Resources Conference Room M2

      Conference Room M2

      Conveners: Mr Rachad Alami (CNESTEN (Centre National de l'Energie des Sciences &amp; des Techniques Nucléaires)), TSec Patrick Brisset
      • 106
        Development of Radiometric Methods for Optimization of Phoshate Transport Process by ''Slurry Pipe''
        Moroccan reserves of phosphates are the largest ones in the world. They are estimated to more than 85 billion m3. The drainage of the phosphate rock from the mines site to the chemical sites, which is currently done by train, requires dry phosphate to lower the humidity in order to carry it cheaply. However the chemical processing of raw phosphates, to get the final products (phosphoric acid, fertilizers…) requires large amounts of water to be added back. For the transport of phosphate, It has been decided to build a pipeline between Khouribga mines to JorfLasfar chemical units, for convergence between cost reduction and rationalization of water and energy consumption. Determination of physical parameters, such as concentration, viscosity, flow rate, etc… of the material inside the pipe becomes a key issue for handling and maintaining the whole system. The current study aim to develop radiotracer methodologies and specific nucleonic control systems to obtain such information. The first phase of the study consists in carrying out of a series of field experiments, aimed flow measurement of pulp phosphates, transported by gravity, by using radiotracers (I-131) in various flow conditions.
        Speaker: Ms Samira MIMOUNT (Centre National de l’Energie, des Sciences et des Techniques Nucléaires (CNESTEN), Morocco)
      • 107
        Determination of Mineral Behaivior in Ball Mills at Chilean Copper Minning Using Radioactive Tracers
        Minera Los Pelambres (MLP) is located in the IV Region of Chile, with a mine located at 3100 masl and a concentrator located at 1600 masl. MLP started its operation in the year 2000 and by 2015 it was one of the 10 largest producers of copper concentrate in the world, achieving 405.300 tons of copper and 9.000 tons of molybdenum concentrates in 2013. MLP has established within its goals to improve the process efficiency and to increase the concentrate production. For these reasons, all the process stages are being evaluated, including the comminution circuits (crushing and grinding), which are the more intensive in terms of energy consumption. The MLP grinding circuit consists of three parallel SAG mill lines, each one formed by a semi-autogenous mill (SAG) and two parallel ball mills. The first two SAG mill lines have ball mills of 10.500 HP, and the third has one ball mills of 10.500 HP and another of 20.700 HP. The ball mills operate in a closed-circuit (direct circuit) with a hydro cyclone battery, which allows the adequate particle for the flotation process to be obtained. In this paper the fluid dynamic characterization of ball mills by means of the residence time distribution (RTD) is presented. The RTD were obtained at industrial scale by using direct measurements of radioactive tracers in the input and output streams of the ball mills. Dried mineral samples from the hydro cyclone underflow were used as a solid tracer. This material was irradiated by neutron activation in La Reina Nuclear Center, Chilean Nuclear Energy Commission. The RTD determination was obtained by measuring the solid tracer in the input and output streams of the ball mills, employing scintillation detectors for real-time measurements. The tracer activities were of 15 mCi of Na-24 in each injection, which contained between 15 and 30 grams of solid. A pneumatic system was designed for the tracer injections. This system allows the tracer injection to be carried out remotely. The measurements demonstrated that a significant percentage of tracer recirculation to the input stream exists. Therefore, the use of parametric deconvolution methods for the RTD determination were required. The model of N perfectly mixed reactor in series was employed for the RTD descriptions, where the N parameter ranged from 2.1 to 3.9 with effective mean residence times between 1.9 and 9.5 minutes. The RTD estimation by the use of radioactive tracers is a powerful tool to characterize the mixing regime in large industrial machines from the mining processes and other productive industries.
        Speaker: Mr Francisco DIAZ (Trazado Nuclear, Chile)
      • 108
        Radiotracer Methods for Ore and Flotation Tailings Leaching
        The copper mining and ore processing is one of the most stable and profitable branch of the Polish economy and the fastest growing industry. However the technologies used lead to high losses of valuable and so called deficit metals (rare earths, uranium and copper) in solid wastes streams. The development and implementation of hydrometallurgical technologies is a solution feasible from the higher elements recovery efficiency and decreasing hazardous impact of the wastes storage on the environment. Radiotracer methods are the suitable tool for process investigation since most of the elements involved may be activated and their radioactive isotopes easily detected. The separation efficiency, process kinetics and flow dynamics of hydrometallurgical systems can be therefore qualitatively and quantitatively evaluated. The objective of the project is elaboration of new efficient method for recovery of copper and critical metals from the various raw materials using radiotracers for process optimization. A key stage of metal recovery process is a leaching process. The raw material was crushed and decarbonized using oxidation techniques and characterized. Initial concentrations of the copper and other elements were determined by ICP-MS, ASS and chromatography methods. The leaching process is carried out in a periodic chemical reactor. For process optimization a radiotracer techniques based on nuclear activation analysis has been used. The samples of the material were activated into neutron flux at the MARIA Reactor and mixed with leached materials. The radiotracers (activated 64Cu) were used to determine leaching efficiency instead of common analytical methods. The results were validated using ICP-MS and ASS analyses. Obtained metal solution will be separated at mixer settlers and ion exchangers also optimized by radiotracers techniques. As raw material we used copper ore and flotation tailings. As we expected the samples contain several metals (Cu, V, Zn, Co, Ag, Ni, Mo, Fe, Pb, Mn, U, REE ect.). The copper concentration was at level 4% in the ore and less than 1% in the tailings waste. The sulfuric acid has been selected as the optimal leaching medium for future experiments. The material was ground and sieved to extract individual fractions. The optimal granulation was selected: 0.25-0.5mm. At leaching step the material was treated with sulfuric acid at various concentrations (2-16M). We also calculated activation parameters for developing activation procedure. The samples were activated and used at leaching experiment for RTD test. Radiotracer methods seems to be suitable tool for leaching process investigation since most of the elements involved may be activated and their radioactive isotopes easily detected. The separation efficiency, process kinetics or flow dynamics of hydrometallurgical systems can be therefore qualitatively and quantitatively evaluated. Radiotracer methods were validated using common analytical procedures and can be used instead of them for controlling and optimization of the process. This work is part of the studies for the IAEA Coordinated Research Projects: “Radiometric Methods Applied in Hydrometallurgical Processes Development and Optimization” and “Radiometric and Radiotracer Techniques in Hydrometallurgical Processes for Deficit Elements Recovery” co-financed by Polish Ministry of Science and Higher Education.
        Speaker: Mr Marcin Rogowski (Institute of Nuclear Chemistry and Technology, Poland)
      • 109
        Radiotracer Investigation in an Industrial-Scale Fluid Catalytic Cracking Unit
        Fluid catalytic cracking (FCC) is one of the main processes used for processing the crude oil in refineries. The efficiency of the cracking process depends upon process parameters such as residence time, residence time distribution, radial distribution and axial mixing of catalyst and gas phases in various sub-units such as riser, disengager, stripper and regenerator of the FCCU. Radiotracer techniques are widely used for measuring for process parameters in industrial process systems. The measured parameters are often used for troubleshooting, performance evaluation, design improvements, and process visualization, optimization and intensification. This paper describes a series of radiotracer experiments carried out in an industrial-scale FCCU in India for measurement of the flow parameters of catalyst and gas phase in various sub-systems of the FCCU. The objective of the experiments was to measure the process parameters to evaluate performance of the FCCU and process intensification. A series of radiotracer experiments was carried out in four sub-units of the FCCU for tracing catalyst and gas phases. Lanthanum-140 (La-140) as catalyst itself and Krypton-79 (Kr-79) gas were used as radiotracers for tracing catalyst and gas phase cracked, respectively. The amount of activities used for tracing catalyst and gas phase in different sub-systems ranged 0.5-2GBq and 4-8 GBq, respectively. The radiotracer was instantaneously injected at the inlet of each sub-system and monitored at different strategically selected locations using scintillation detectors. The data recorded in different radiotracer tests were treated and analyzed. From the treated curves mean residence time, velocity, slip factor were obtained. In order to investigate radial mixing of the phases across the cross-sections of the different sub-systems, multiple detectors mounted at each axial location were plotted and analyzed. In case of a good radial distribution, all the detectors mounted at an axial position will provide identical responses provided the wall and insulation thicknesses at the monitoring conditions were identical. However, different intensities of the monitored curves will indicate poor radial distribution of the phases. To investigate axial mixing, axial dispersion model was used values of model parameter i.e. Peclet number (Pe) was obtained. The parameters were successfully measured and flow anomalies were identified. Homogeneous radial distribution of the two phases was observed in the riser section of the FCCU, whereas in other sub-systems, the radial distribution of the phases was poor. The velocity of gas and solid phase were measured to be 9.9 and 6.4 m/s, respectively. The slip factor was estimated to be 1.5, which was as per design criteria for efficient cracking reactions in the riser section. The flow of gas phase in the riser was observed to be as plug flow, however moderate degree of axial backmixing was observed in case of catalyst flow. The results obtained helped to plan the necessary modifications in the FCCU, scale up the capacity and optimize the performance of the system.
        Speaker: Mr Harish Jagat Pant (Bhabha Atomic Research Centre, Trombay, India)
      • 110
        Developing a Commercial Facility for Rapid Assay of Gold and other Elements in Mineral Ores Using Gamma Activation Analysis
        The global mining industry relies on elemental analysis throughout their value chain. The development of near real-time analysis techniques such as on-stream and hand-held X-ray fluorescence allows assay data to be used for process control and optimisation. Unfortunately, current methods have insufficient sensitivity to measure metals such as gold, which are mined at concentrations of a few parts-per-million (ppm) or less. Gold is currently measured commercially using the process of fire-assay, a laborious, time-consuming, manually intensive and hazardous process. Extensive sample preparation requirements mean that analysis turn-around times are typically at least 24 hours, precluding the use of the results for control purposes. We have been developing gamma activation analysis (GAA) as an alternative approach. GAA mimics the more conventional neutron activation analysis (NAA), using a high-intensity radiation source to activate target elements in samples, and then measuring characteristic gamma-rays emitted from activated radioisotopes. Unlike the nuclear reactor commonly required for NAA however, GAA uses a high-energy X-ray beam produced using an electron accelerator. GAA is particularly well-suited to the analysis of gold via excitation of the 409 keV, 7.73 s half-life meta-state of 197Au. The short half-life of the meta-state, and the fact that it can be excited using X-rays with energies below the activation thresholds of major rock-forming elements, make the method particularly rapid and sensitive. Notwithstanding these potential benefits, the GAA method has found only very limited commercial application, with only one industrial facility operating worldwide to our knowledge. In this paper we report developments in several areas: • Our work to better understand the physics of GAA and significantly improve sensitivity and accuracy. We demonstrate how a novel correction method allows accuracies of better than 1-3% to be achieved (figure 1). • Optimisation of a practical system for round-the-clock commercial operations, including design of the X-ray source, shielding, detector systems, and automated sample handling. • Safety and regulatory approval. We discuss the development and use of advanced Monte Carlo software tools for shielding design and evaluation of residual activity. • A profitable facility model and effective industry engagement strategy. We report on experiences setting up our first commercial GAA facility and our strategy for engaging with industry partners and customers to build acceptance of a new analysis method. • Planning for a containerised GAA facility, suitable for rapid deployment on mining and mineral processing sites to facilitate provision of near real-time analysis data. The new facility is currently in the advanced planning stage and is scheduled to start operations in mid-2017. [Figure 1 goes here] Caption: Comparison of GAA and lab grades for a large suite of gold samples; results for samples below 3 ppm gold (linear scale, left-hand plot) and all samples (log scale, right-hand plot).
        Speaker: Mr James Tickner (Commonwealth Scientific and Industrial Research Organisation (CSIRO), Australia)
      • 111
        A Tracer Application in Detecting Damage to Oil Industry Piping
        Damage to the internal surfaces of piping systems of process industries is caused by continuous exposition to mechanical and chemical processes throughout their life span. This paper reports on a preliminary evaluation as to whether radiotracer techniques can be used in the detection of the two most frequent deterioration processes in an oil production and refining, viz. corrosion and scaling. Usually conventional non-destructive tests, all of which suffer from some some limitation, are used in inspecting the impaired material and equipment. In turn, radiotracers are can be inserted into the flow and afford easy detection and measurement. The question is: the method is sensitive enough? Residence time distribution models that are widely used in fluid flow studies may disclose the conditions inside the investigated system. In this paper both the competence of the tracer technique in identifying which process - corrosion or scale formation - is acting, and of evaluating how much it is interfering with the flow. The tests were performed in pieces of the API 5L-B structural steel, which used in oil refineries. Three test specimens were used: one was flawless (CP-A), in a second one (CP-B) an ad hoc groove had been carved around its inside surface aiming at simulating a corrosion singularity, and in the third one (CP-C) an encircling metallic bulge was welded to its internal surface to simulate a scaling anomaly. Activated manganese sulfate monohydrate (56MnSO4.H2O) in aqueous solution has been as the radioactive tracer. The manganese salt has been irradiated in the CDTN TRIGA reactor facilities. A fluorescent tracer (Rhodamine-WT) has also been tested for comparative purposes. Thr The tests were performed under different flowrate conditions: 0.10, 0.40, and 0.90 m³/h. The DTSPRO software has been used to analyze the flow residence time distribution curves and the ANSYS CFX 15 fluid dynamics software was used to define the flow in the flow obtained inside test specimens. The results achieved with both radioactive and fluorescent tracers indicated that the presence of the discontinuities in the specimens caused a perturbation in the flow that could be detected by the tracer technique. No deviations relative to a free flow were fount in the CP-A probe, whereas some localized recirculation was detected in the CP-B probe, and stagnation or dead zones was noticed in the CP-C probe. It has been considered that the tracer technique has a potential use in discerning the presence of discontinuities such as corrosion and scale formation in pipes.
        Speaker: Mr Rubens Martins Moreira (Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Brazil)
      • 12:45
        Discussion
    • 13:15
      Lunch break
    • P-A1: Irradiation Facilities and their Applications

      Poster Session on Irradiation Facilities and their Applications. Authors will present.

      Conveners: Mr Mark Bailey, TSec Sunil Sabharwal
      • 112
        $\gamma$-Radiation-Co-Cryogelation Induced Synthesis of Macroporous rpCryogels for Bioengineering Applications
        Abstract Polymeric porous scaffolds are a key component in several bioengineering and biomedical applications. In a recent development, we have introduced a novel approach for the designing of macroporous matrices by combining $\gamma$-radiation with cryogelation technology. This new prototype has been optimized and compared with the classical cryogelation technology. The acrylic derivatives like acrylamide (AAm) and N-(2-hydroxyethyl) methacrylamide (HEMA) have been used in our study as the model precursor units considering their inert behaviour and selective biocompatibility. In the process of radiation-co-cryogelation, optimum radiation dose causes polymerization of monomers, which do not require addition of any reaction initiator and activator for free-radical polymerization. However, simultaneous cryogelation allow the phase separation which leads to the formation of water ice crystals (porozens) at sub-zero temperature. The optimum process parameters like radiation dose, temperature, monomer’s concentration, physical/chemical molding, volume and incubation time, are providing suitable environment to fabricate an ideal porous radiation-cryopolymerized cryogel (rpCryogel). This new approach is suitable to fabricate scaffolds with controlled physico-chemical properties like variable pore sizes, pore interconnectivity and desired mechanical integrity and rheological properties by varying the dose of $\gamma$-radiation and temperature at constant polymer precursor’s ratio. The scanning electron microscopic observation of AAm and HEMA rpCryogels shows presence of interconnected pore morphology having pore size range of $20$ to $200~\mu$m at different doses of irradiation. Like classical cryogel, the rpCryogels showed similar behaviour of various physico-chemical properties like hydraulic permeability ($10^{-4}$ m$^4$N$^{-1}$s$^{-1}$), density ($1$ to $1.5$ g/cm$^3$), water uptake kinetic (reach to equilibrium within $1$ min) and water retention capacity (more than 10 times its dry weight). Mechanical stiffness of rpCryogel showed a steep decrease ($10$ times reduction in compression modulus) upon hydration in distilled water suggesting its hydrophilic nature and soft material like property, which is preferable in many bioprocesses. These monoliths can be compressed up to $70\%$ of their original length without showing permanent deformation presenting their high elastic behaviour. Importantly, unlike classical cryogel which require approximately $18$ h for synthesis, this novel integrated approach requires only $3$ h for the fabrication of rpCryogels in different formats. The transitional changes between dry and wet state did not show change in its physico-chemical properties, which describe long term storage stability of these rpCryogels in dry state and wet state. Thus, the designing of elastic and macroporous monoliths by integrated controlled radiation and cryogelation process provides novel speedy approach for the fabrication of macroporous rpCryogel for various bioengineering application and could meet the supply requirement for commercial utilization. At present, we are investigating the successive use of macroporous polymeric cryogels for biomolecules immobilization, bioprocessing, tissue-engineering and environmental applications.
        Speaker: Mr Anuj Tripathi (Bhabha Atomic Research Centre, Mumbai, India)
      • 113
        A New Fluorescence Detection Method with Plastic Scintillators Using a Conventional LSC -Organic Waste Less Method
        Introduction; For tracer experiments in life science field, many types of compound are labeled with beta-emitters. The beta-emitters are generally measured using an liquid scintillation counter (LSC) because of their low energies. An LSC is a superior machine with high counting efficiency; however, there are mainly 2 demerits. Organic liquid wastes are generated after measurement because the sample is dissolved in liquid organic scintillator. And also a quenching of spectra always arises, so no one can identify what kind of nuclides exist in a sample. We developed a new fluorescence detection method with plastic scintillators, which are alternative material of liquid scintillator, using a conventional LSC without generation of organic liquid waste. Methodology; Two kinds of plastic scintillator (PS) were prepared; a sheet type (BC-400; Saint Gobain USA) and a pellet type (EJ-200; G-tech Japan). The sheet was 0.5 mm in thickness and it was cut 55 mm in length (max. 75 mm) and 20 mm in width (max. 30 mm) for a 100 mL Teflon vial which inner diameter is 33 mm (Sanplatec Co. Japan) and it was used for nonvolatile compounds. The pellet was a 3 mm cylindrical shape and approximately 90 g of pellets were put in the Teflon vial, which were used for volatile compounds. An LSC used was LSC LB-7 (Hitachi, LTd. Japan). Radioactive materials used (Moravek Biochemicals Inc. USA) were 3H-methionine, 14C-arginine and 35S-methionine as nonvolatile compounds and tritiated water and 14C-acetic acid sodium salt as volatile compounds. Additionally, the surface of the PS-sheet was treated with dielectric barrier discharge plasma or fluorine gas treatment for tritium compounds measurement, because the surface was changed hydrophilicity and the contact area with the sample solution was extremely widened. Quantitative analysis and detection limits for using both of sheets and pellets were studied. Results and discussion; The counting efficiency using the PS-sheets was same as that of liquid scintillator use, when the surface of PS-sheets were treated with plasma for tritium measurement. Though the PS-pellets showed higher counting efficiency compared with that of liquid scintillator when the sample solution was less than 500 μL, the counting efficiency was decreased depending on the sample solution increased. However, the detection limit became low with large sample solution. Conclusion; Quantitative and qualitative analysis of beta-emitters were possible using plastic scintillators without generation of liquid organic waste. The PS-pellets and sheets could be used repeatedly after rinsing under hot running water. These PS-methods are low load and eco-friendly.
        Speaker: Ms Etsuko FURUTA (Ochanomizu University, Japan)
      • 114
        Application of Electron Beam for Preservation Biodeteriorated Cultural Heritage Paper-Based Objects
        Paper provides the ideal nutrient base for mould fungi. Therefore biodeterioration is the most common source of degradation of paper-based materials in museums and libraries. Application of electron beam irradiation in field of cultural heritage preservation is very promising alternative for commonly used ethylene oxide treatment, which is toxic to human and natural environment. Moreover electron beam irradiation can be effectively applied for decontamination of biodeteriorated archives as well as for preventive conservation of large volumes of books in short time. However, to gain public acceptance for radiation methods in large-scale applications many analytical techniques must be used in order to determine possible changes of mechanical, chemical and physical properties of treated objects. Complex study of material properties before and after radiation decontamination should ensure degradation monitoring and process validation. In this work the influence of electron beam irradiation used for microbiological decontamination process on paper-based objects was evaluated. In this study the connections between electron beam irradiation doses and a change of some chemical, optical and thermal properties of different kinds of paper were established. Electron beam radiation inactivation patterns of different microorganisms present in different paper materials were studied as well. The samples were exposed to electron beam irradiation using a 10 MeV-10 kW linear electron accelerator “Elektronika” and dosimetric analysis necessary for the proper realization of the process was performed with application of Riso B3 thin-film dosimeters as well as graphite calorimeters. A wide range of doses from 0.4 kGy up to 25 kGy were studied in order to determine safe and simultaneously effective dose for different papers decontamination with electron beam. Changes in all samples properties were determined according to the relevant ISO and TAPPI standards. Microbiological investigation confirmed that dose of 5 kGy completely eliminate all studied kinds of bacteria (gram-positive and gram-negative) as well as fungi in Whatman CHR 1 paper, newsprint paper and office paper. Optical parameters for all studied papers are stable for materials irradiated with doses not higher than 5 kGy, however colour coordinates are still changing with time after irradiation and the effect is being evaluated. Investigation of optical parameters of the paper after irradiation confirmed that coordinate b* is the optical parameter the most sensitive to electron beam irradiation, what means that paper samples irradiated with high doses became more yellowish. The control samples and the irradiated samples show similar thermal stability in air on heating. Taking into account even high levels of the microbiological contamination (in the order of 10^5 CFU/cm^2) of paper-based objects electron beam irradiation with doses of 5 kGy ensures elimination of harmful microorganisms and simultaneously prevents paper materials degradation. Acknowledgement This work was supported by International Agency of Atomic Energy, Research Contract No. 18493 and by the Polish Ministry of Science and Higher Education, project “Electron beam for preservation of biodeteriorated cultural heritage paper-based objects”
        Speaker: Ms Dagmara Chmielewska-Śmietanko (Institute of Nuclear Chemistry and Technology, Poland)
      • 115
        Application of Ionizing Radiation for Treatment and Valorization of Cork Wasterwater
        The wastewater produced from cork industry has a high concentration of undesirable cork extracts such as phenolic acids, tannins and 2,4,6-trichloroanisol. These compounds are difficult to degrade by conventional treatments, which make this water a toxic and recalcitrant effluent that constitute a risk for the ecosystem and require treatment before being discharged into the environment. This work represents a comprehensive study of the use of gamma radiation as an advanced oxidation process for wastewater treatment. This work was carried out aiming to degrade recalcitrant compounds, although it was also assessed the potential valorization of the cork industry wastewater through the selected recovery of the valued antioxidants. The irradiations were performed at room temperature in a Co-60 chamber at the absorbed doses: 20, 50 and 100 kGy and dose rate range of 1.6-2.4 kGyh-1. pH, COD, BOD and TSS were determined according to the Standard Methods for the Examination of Water and Wastewater. Total Phenolic content (TP) was quantified by Folin-Ciocalteau method. The antioxidant activity was measured by DPPH radical scavenging activity, reducing power and inhibition of β-carotene bleaching. The identification of the phenolic compounds and its radiolytic products was carried out by HPLC-DAD-ESI/MS. To test the hypothesis that the radiolytic effect of gamma radiation could promote the biodegradability of phenolic acids products, microbial culture growth experiments were performed using a microbial population of four bacterial strains naturally present in cork wastewater sedimentation tank samples. Recovery studies of antioxidant compounds present in cork wastewater were carried out at adsorption/desorption experiments using a synthesized mesoporous carbon. The toxicity of irradiated cork wastewater and its radiolytic products was evaluated by cellular growth inhibition method using different prokaryotic and eukaryotic cells. Cork wastewater indicated a low pH of 5.14, a high value of COD (2903 mgO2L-1) and a low biodegradability (BOD5/COD=0.136), that can be explained by the presence of hardly biodegradable natural compounds. The TSS and TP values are 134 mgL-1 and 680 mg gallic acid L-1, respectively. The most abundant phenolic compounds identified were: gallic, protocatechuic, vanillic and syringic acids, that presented high antioxidant activity. After irradiation, the results suggested that gamma radiation is a potential technology for wastewater treatment. The BOD and TSS values are greatly reduced (≥45%) at 100kGy. TP and antioxidant activity increase around 33% which opens the possibility of recovery of the added value compounds to be utilized in other industries. Concerning adsorption/desorption studies it was achieved a 40% recovery of vanillic and syringic acids using the activated carbon. Non-treated cork wastewater seems to be non-toxic for the majority of the studied cells. Gamma radiation treatment affected the toxicity of cork compounds for prokaryotic and eukaryotic cells, which could be related to a cytotoxicity effect of radiolytic products of cork compounds. Further studies are being carried out to understand these radiolytic mechanisms and alternative adsorbents will be tested for selective extraction of the valuable antioxidants.
        Speaker: Ms Sandra Cabo Verde (Instituto Superior Técnico, Portugal)
      • 116
        Application of Isotopic Techniques Using Mathematiocal Models in Environmental Process
        During the last few decades, the use of tracer techniques in dealing with a variety of hydro-logical and hydro-geological problems have proved their value in improving the assessment , development of water resources. In this regard , the methodologies based on observations of temporal and spatial variations of naturally occurring isotopes, often referred to as { environmental isotope techniques} , are widely employed as an integral part of the routine investigations related to various hydro-logical systems, and particularly in regional groundwater aquifers. A substantial amount of isotope data was so far collected and published from hydro-logical applications of natural isotopes, however, it is often used for qualitative inferences to be made of the system under study, and improve understanding of processes and dynamics of water circulation. The need for improved methodologies for quantitative evaluations to be made from isotope data with regards the relevant physical parameters of the system has been recognized. This has been the main motivation to intent the progress on mathematical models for quantitative evolution of isotope data in hydrology. Isotope-hydrology(Stable and Radio isotopes) have been previously used to investigate water resources, interconnection between different aquifers ,relationship between surface and groundwater as well as direction of recharge ,…etc. Now a day ,mathematical modeling by using isotopes are used in modern ecosystem studies, for investigating the source, direction, quantity and transport of pollutant, moisture isotope fluxes in present and past climate systems ,as well as transit time estimation in catchments hydrology. Focusing our discussion on the use of environmental tracers in water molecule itself such as , 18O, 2H, and 3H. These ideal tracers are applied by precipitation and are generally distinct isotopic-ally, which makes them reliable tracers of subsurface flow and groundwater recharge mechanism. Two case studies were chosen, the first case illustrate calculation of the mean residence time for groundwater in the investigated area, using Tritium isotope. The age of groundwater was found in the range from few tens to several hundreds of years, reflecting the recharge mechanism and possibility of contamination. The second case study was applied using deuterium isotope balance approach to separate evaporation and seepage rates per year in lake area.
        Speaker: Ms Wafaa Mohamed Moustafa (Egyptian Nuclear and Radiological Regulatory Authority, Egypt)
      • 117
        Application of Low Energy Electron Beam in Microbiological Decontamination Process
        Food preservation with ionizing radiation has about 100 years of history. To date, more than 50 countries have given approval for over 60 products to be irradiated. The most popular is application of gamma irradiators. The increasing interest is also observed for application of high energy electrons as well as x-rays. New trend in application of this technology is related to use of low energy electron beam, characterized with limited penetration depth. In the process with the use of high energy electrons, the whole volume of food is irradiated. Since microorganism reside mostly on the surface of dry food, irradiation of external layer should be sufficient to eliminate food-borne microorganisms. Additionally the operation safety issue is also important, since low energy EB machines are equipped in local compact shielding and can be installed along with other industrial machinery in same room Presented study concentrates on determination of microbiological decontamination process efficiency with the use of e-beam of energy between 300 and 100 keV. Two electron accelerators installed in INCT were be used in experiments. Elektronika (10 MeV, 10 kW) was applied for irradiation with high energy electrons. Accelerator ILU-6 is a resonant type machine which nominal operating range of the beam covers the energy range from 600keV to 2MeV. Low electrons energy was achieved by reducing the accelerating RF voltage. For the need of this study the modification in pulse power supply system, arrangement of electron gun and beam sweep system of accelerator ILU-6 was performed to lower energy of emitted electrons below 300 keV. The energy of used electron beam was controlled using stack of B3 dosimetric film. In the experiments the microbiological load reduction was tested for food products, irradiated with doses from 1 to 10 kGy. Selected samples of spices, dries herbs and seasonings with different density and porosity were tested to control total amount of aerobic bacteria and mould. The relationship between dose of radiation for different energies of electrons and effectiveness of the process was established. The effects of irradiation with low energy electrons were compared with effects for high energy electrons. *The work was supported by Polish Ministry of Science and Higher Education under the project "Investigation on application of low energy electron beam for microbiological control of food and agricultural products" and by International Atomic Energy Agency under the Coordinated Research Project D61024.*
        Speaker: Ms Urszula Gryczka (Institute of Nuclear Chemistry and Technology, Poland)
      • 118
        Assessment of Safety Systemns Design of Industrial Irradiation Facilities in Brazil
        **BACKGROUND** Accidents occurring in irradiation facilities have demonstrated that these facilities have safety-critical systems, which should be designed to meet proper safety requirements. The IAEA’s publication SSG 8 provide specific and practical recommendations on the safe design and operation of irradiations facilities, for use by operating organizations, the designers of these facilities and by regulatory bodies. The first industrial irradiation facility in operation in Brazil was designed in the ’70s. Since then, minor modifications and upgrades, as sensors replacement, have been introduced in order to reduce the technological gap in the control and safety systems, however, in the case of safety systems in irradiation facilities, the requirements concerning safety and reliability are of ultimate importance. **METHODOLOGY** This work evaluates the adequacy of existing safety systems and their sensors at Brazilian irradiation facilities, taking into account the recommended IAEA’s design requirements. The study is based on an assessment of the licencing process of irradiation facilities, as well as the experience of regulatory inspections in these facilities. It was also taken into account the knowledge, concepts and solutions developed to upgrade existing safety system in facilities throughout the world. **RESULTS** Irradiation facilities can be defined on the basis of its design and, in particular, the accessibility and shielding of the radioactive source. The Brazil facilities can be categorized into 9 panoramic $\gamma$ irradiators (4 dry and 5 wet storage) and 4 panoramic irradiation facilities using generators. Notable findings arising from this study include: a)  Some sensors are not interlocked with the irradiator central controls unit, thus they not act automatically when a predetermined value is exceeded, this condition is normally observed, basically, on the radiation monitor of the water treatment system and on the fire protection system; b) In older irradiators the seismic detector is not installed; c) Redundant systems in the personnel access door can be improved, using pressure mats combined with optoelectronic barriers. Additionally, it was considered if the irradiation facility can be operated only if all safety systems are in place and functioning. **CONCLUSION** It was carried out a diagnosis of the “state of the art” of safety systems of Brazilian industrial irradiators, taking into account the national regulations and the latest IAEA´s recommendations. Some sensors of safety systems in oldest Brazilian irradiators can be improved, basically for automatic actuation, thus the upgrade of control systems in irradiator facilities would use the advances in computer technology, old control units based on relay logic should be replaced with a new one based on redundant programmable logic controllers, however, it should be emphasized that the operating organization should obtain the approval of the regulatory authority before implementing any modifications on the irradiator that may have significant implications for radiation protection.
        Speaker: Mr Rogerio Gomes (Brazilian Nuclear Energy Commission, Brazil)
      • 119
        Conceptual Development of an Irradiator for Cross-Linking of Cables Using 60Co Gamma Rays
        ** Setting up of new radiation Facilities -------------------------------------- ** Cross-linking provides significant commercial benefits to wire and cable insulation. Ionizing energy is an efficient means of cross-linking the polymers to improve many cable properties including insulation. In this process chemical bonds are formed between layers of polymer molecule to produce three-dimensional insoluble network. The present methods of cross-linking are thermal/chemical/e-beam from accelerators. E-beam cross-linking is the latest and improves properties like fire resistance, flame properties, abrasion resistance, stress crack resistance etc. However there is a limitation of e-beam penetration in large diameter cables (>0.030 m dia.) restricting its application. Therefore the feasibility of processing multi core cables of large diameters with gamma rays was explored. The insulation jacketing of multi core cables are made of PVC or PE. The dosimetric aspects were studied for a cable irradiator- design which has been made in such a way that the cable will move through a pipe housed in Gamma Irradiation Cells (GICs) each of which have 60Co source pencils (BRIT made BC-188) of 7.4PBq arranged around the pipe in a suitable diameter (PCD). The pipe can accommodate cables of diameters up to 0.072m. The cells have effective irradiation lengths (~1m) and lead shielding of adequate thickness. The objective of the study was to evaluate the dose profile in cables when irradiated in a gamma irradiation cell and to optimize the PCD of source pencil arrangement to get the appropriate Dose Uniformity Ratio with the specified target dose of 100kGy & to arrive at no. of irradiation cells required for a suitable through-put. Based on the results of the study a gamma irradiator with multiple no. of irradiation cells is under development in BRIT, a unit of the Department of Atomic Energy, India.
        Speaker: Mr Jain Reji GEORGE (Board of Radiation & Isotope Technology, Department of Atomic Energy, India)
      • 120
        Core Neutronic and Source Strength Analyses of Co-60 Production in Local Power Reactors
        A detailed analytical study on the feasibility of local production of cobalt-60 in power reactors of Pakistan, C-1 & C-2 (Chashma Nuclear Power Plant, unit-1/unit-2, PWR type), has been made by irradiating metallic pencils of cobalt-59 in-core and out-of-core locations. In the first scheme, four fresh fuel assemblies with 4 guide tube locations per fuel assembly have been selected for in-core Co-59 loading. A total of about 150000 curies of Co-60 are produced in these locations over a period of one fuel cycle (~ 385 days). Detailed neutronic analysis of C-1/C-2 core was carried out in order to determine the effect of samples irradiation upon core performance at full power. The reactivity calculations show that fuel cycle length would be slightly shortened approximately by 1 day without affecting the safety parameters due to Co-59 loading at in-core locations. The estimated specific activity of cobalt pencil at the end of 1 year is 19.25Ci/g. Alternatively, in C-1 & C-2 reactors the four out-of-core vacant locations on the outer surface of Reactor Core Barrel, which were earlier occupied by the now-withdrawn Surveillance Capsules Assemblies (SCAs), have been selected for Co-60 production. In this scheme four bundles in the form of stainless steel tube, each tube containing 18 concentric cobalt pencils would be loaded in SCA hanger assemblies. An estimated 30,000 curies of Co-60 are produced in these locations over two core cycles (~ 770 days). Since cobalt targets are placed in the same ex-core locations that earlier contained the stainless steel and other RPV material samples in SCAs, the cobalt loading would have no impact on nuclear reactor safety. In order to determine the effect of Cobalt-59 irradiation upon core reactivity, a detailed neutronic analysis of C-1/C-2 core was also carried out at full power. The core design calculations show that there is no significant effect on critical core parameters and reactor operation, and fuel cycle length is not reduced. The calculations show that the estimated specific activity of capsule at the end of 2 years is 0.83Ci/g at the cobalt loaded SCA location. For a total mass of 35kg of 72 Cobalt-59 samples, the total activity from the production of Co-60 is estimated to be 30,000 Curies. Detailed shielding analysis and dose rates of irradiated Co-60 pencils have also been carried out. Thicknesses of shielding materials have been optimized based on the surface dose rate criteria of ≤ 2mSv/h. Based on these analyses, the cylindrical shielded transport containers with different loading combinations have also been designed for safe transportation. From these analyses, feasibility of production of cobalt-60 at the in-core and out-of-core vacant locations of SCAs in power reactor has been demonstrated without any major modification in reactor core and imposing any serious impact on reactor core performance and plant safety.
        Speaker: Mr Aamir Ihsan (PAEC, Pakistan)
      • 121
        Degradation Characteristics and Transformation Products of Iodinated Contrast Media Using Ionizing Radiation
        In the present study, the degradation of iodinated X-ray contrast media (ICMs) using ionizing radiation was investigated. ICMs, radiocontrast agents containing iodine for enhanced visibility of vascular structure and organs, are one of the widely used diagnostic pharmaceutical compounds. ICMs are considered as persistent pollutants in watershed due to continuous release into aqueous ecosystem and low degradation efficiency in conventional treatment processes. Therefore, various advanced oxidation processes (AOPs) have been currently applied to treat non-degradable pharmaceuticals including ICMs. Radiolysis is a new treatment technology to eliminate a variety of non-degradable compounds, showing higher degradation efficiency. Although studies considering degradation of non-degradable compounds with AOPs have been increased, there has been insufficient information of byproducts produced by the treatment, especially ionizing radiation. Therefore, the aims of this study was to evaluate the degradation characteristics of ionizing radiation treated ICMs, and to identify the radiolytic transformation products. The target compounds were treated using ionizing radiation, with the absorbance doses from 0.1 to 5 kGy (1 kGy = 1 kJ kg-1). Ionizing radiation was achieved using a high level 60Co source at the Korean Atomic Energy Research Institute (KAERI, Rep. of Korea). LC-QTOF-MS (Agilent Technologies, USA) and LC/ESI-MS/MS (Agilent Technologies, USA) were used for qualification and quantification analysis of degradation byproducts. In order to confirm that the byproducts of irradiated ICMs were originated from the radiolysis, the variation of parent compounds in dark control was estimated. There was no relevant change of target compounds in dark control for 40 days, indicating that hydrolysis of target compounds were negligible. Target compounds were rapidly declined with absorbance doses, showing the rate constants (kr) of 1.7299 kGy-1 (ioversol), 1.5485 kGy-1 (iohexol), 1.3745 kGy-1 (iopromide), 1.3522 kGy-1 (diatrizoate), and 1.2726 kGy-1 (iopamidol) (r2>0.99). Degradation of ICMs led to sequential release of iodide, indicating that reductive deiodination is one of the major degradation mechanism of ICMs. Deiodinated degradation byproducts of iopromide including TP665 (C18H25I2N3O8), TP540 (C18H26IN3O8), TP414 (C18H27N3O8) were also detected in qualification analysis.
        Speaker: Mr Seungho Yu (Korea Atomic Energy Research Institute, Korea, Republic of)
      • 122
        Detoxification of Aflatoxin B1 and Ochratoxin A by Gamma Radiation
        **Background of the study**. Mycotoxins aflatoxin B1 (AFB1) and ochratoxin A (OTA) are widely distributed food contaminants that have adverse effects to animal and human health. In order to reduce mycotoxins’ contamination and protect animal and human health, various strategies are applied. Some studies indicate that gamma irradiation is effective in reducing mycotoxins’ contamination. Therefore the aim of this study was to investigate the effect of gamma irradiation on the AFB1 and OTA degradation as well as toxicity of mycotoxins’ radiolytic products in vitro. **Methodology.** Mycotoxins stock solutions in methanol (50 mM) were gamma irradiated with doses of 5 and 10 kGy and dose rate of 140 Gy/min using panoramic 60Co source in the Radiation Chemistry and Dosimetry Laboratory at the Ruđer Bošković Institute. The dose rate was established using the ethanol-chlorobenzene dosimetry system. Molecule structure analysis of non-irradiated and irradiated AFB1 and OTA was performed by liquid chromatography tandem mass spectrometry (HPLC-MS/MS). Toxicity of non-irradiated and irradiated AFB1 and OTA (in concentration 1-500 μM; 24 h) was tested on HepG2, SH-SY5Y and Pk15 cells by quantitative colorimetric MTT assay. **Results.** Gamma irradiation even at 5 kGy effectively degraded AFB1 and OTA molecule. The signal intensity for non-irradiated AFB1 was 16 times higher than for irradiated AFB1 (5 kGy) and signal intensity for non-irradiated OTA was 2 times higher than irradiated OTA (5 kGy). These results indicate that AFB1 has greater susceptibility than OTA to gamma irradiation. Besides of fragment ions of AFB1 or OTA with mass less then parent ion, several radiolytic products with mass higher then parent ion were detected. These results strongly indicate the contribution of addition reactions caused by free radicals generated in solution during gamma radiolysis. Results on cytotoxicity indicate that radiolytic product of irradiated AFB1 and OTA are less toxic to HepG2, SH-SY5Y and Pk15 cell lines than non-irradiated mycotoxins (parent compounds). **Conclusion.** Based on the AFB1 and OTA structure modifications induced by gamma irradiation, free radical mechanisms are operative in the irradiation of mycotoxins. Additionally, cell viability assay demonstrated that mycotoxins radiolytic products are less toxic to cells than parent non-irradiated compound. Based on these results gamma irradiation can be considered as an effective method for the detoxification of mycotoxins.
        Speaker: Ms Branka Mihaljevic (Ruđer Bošković Institute, 10000 Zagreb, Croatia)
      • 123
        Detoxification of High Toxic Substances by Radiation Transformation Technique
        Developing a new substance takes a large amount of time, money and effort in the pharmaceutical developing process. Usually, translation of a promising molecule into an approved drug takes more than 10 years. Therefore, it lead to develop advance techniques to reduce the time and cost. We have attempted to develop radiation fusion technology for transforming toxic substances such as abandoned drugs and naturally occurring polyphenols, known to toxic, in order to reduce their toxicities. About 200 substances were exposed by gamma irradiation, result in 18 compounds were generated with low toxicity compared to their mother compounds. For instance, rotenone, isolated from roots of derris plant, was reported as an anti-cancer agent. However, recent studies have demonstrated that rotenone has the potential to induce several adverse effects such as a neurodegenerative disease. Radiolytic transformation of the rotenone with gamma irradiation afforded new products, named rotenoisin A, and rotenoisin B monitored by HPLC and purified by column chromatography. It was found that rotenoisin A and B were potent anticancer candidates similar to parent rotenone in breast cancer and hepatic cancer cells, respectively, without toxic effect to normal cells even at high concentrations compared to rotenone. These results suggest that the radiolytic transformation of high toxic compounds by gamma-irradiation may be a good strategy for modifying the structure and decreasing the toxicity of the parent compound. More systematic structural modifications together with gamma-irradiation will be performed in the future to further clarify these interesting findings in order to develop even more promising anti-cancer candidates.
        Speaker: Mr Jinhong Kim (Korea Atomic Energy Research Institute, Korea, Republich of)
      • 124
        Development of a Digital Model for the Dosimetry of the Cobalt 60 Irradiator at the National Polytechnic School of Ecuador
        This project presents the development of a digital model using the MCNP program to simulate the dosimetric distribution of the Cobalt-60 irradiation facility of National Polytechnic School of Quito-Ecuador, with a 100 kCi installed capacity. First, a map of absorbed dose was obtained with Fricke dosimeters distributed through the irradiation chamber, at five different distances fixed from the source (20, 40, 60, 100, 165 cm). A irradiation time based on the time required for a dose of 300 Gy at 20 cm from the source was set to measure the dose. This time was fixed for all the distances. The irradiation process was performed three times. To define the input data for the model it was necessary to establish the geometry, dimensions, materials and chemical compositions forming the irradiation chamber. To calculate the absorbed dose a quantizer data or "tally " was used to determine the energy deposited in a given area , called cell. In order to characterize the twelve pencils composed the Cobalt -60 source, the SDEF code was applied to simulate a fixed source and photons. Several changes at the starting model input data were needed to set and improve the perfomance. The final digital model was achieved with an error of less than 15% when compared with data obtained by Fricke dosimetry, therefore this model was validated.
        Speaker: Mr Francisco SALGADO (Escuela Politecnica Nacional del Ecuador, Ecuador)
      • 125
        Dose Increase System in a Gamma Irradiator
        In China, many gamma irradiators’ users encounter a problem, i.e. the product kinds are various, but each product quantity is small. The absorbed-dose for each kind of product is usually different. When processing these products, the user has to wait for completing one kind of product, empties the source pass mechanism, changes the master time, then start to irradiate another kind of product. This cause the throughput and source efficiency to be lower. To solve this problem, in the new type gamma irradiators (BFT type) in China, we have designed a dose increase system. This system includes joint roller, stopper, barcode reader etc., which is set inside the maze. Barcodes are attached on all totes. For different products, the master time is set according to the absorbed dose common divisor. For example, there are three kinds of product whose absorbed doses are 10kGy, 15kGy and 25kGy. In order to process them at the same time, the master time can be set to make one cycle of irradiation to reach 5kGy. So the totes loading these products should be irradiated for 2, 3 or 5 cycles, which are related to their barcodes. During the irradiation, when a tote is conveyed to the outlet of the maze, the barcode reader will send its barcode to the control system. The control system will decide the next motion by the tote’s total cycles and its finished cycles: if the finished cycles are less than the total cycles, the tote will be moved to the joint roller and be conveyed back to the radiation room; if the finished cycles equal to the total cycles, the tote will be moved to the unloading station. The dose increase system has been applied in many BFT type gamma irradiators. The result shows that the system works out the problem of dealing with many kinds of small batch products. The system improves the throughput and source efficiency greatly.
        Speaker: Mr Ge Liu (BINE High-Tech Co., Ltd., China)
      • 126
        Dosimetric Calibration of a Panoramic 60Co Gamma-Ray Source
        **Background of the study**. The panoramic 60Co source at the Ruđer Bošković Institute is the only irradiation facility in Croatia suitable for variety of applications: from medium range doses used in radiobiology and accident dosimetry to high doses pertaining to radiation processing and research in radiation chemistry. In November 2015 thanks to the IAEA support the source was upgraded with additional 3.5 PBq. The results of precise dosimetric calibration and determination of dose distribution curves typical of the cylindrical gamma ray panoramic source geometry are presented. **Methodology**. Because of the cylindrical shape of the source, the radiation field also has a cylindrical symmetry and is best described by cylindrical coordinates. Radiation field mapping was performed with ethanol-chlorobenzene (ECB) dosimetry system which was developed 50 years ago in our Radiation Chemistry and Dosimetry Laboratory and subsequently accepted as an international standard (ISO/ASTM 51538). The commercial 5 cm3 pharmaceutical ampoules were used for irradiations. Irradiated ECB dosimeters were analysed for chloride ion concentration by two methods: oscillometry before opening; after opening aliquots were taken for mercurimetric titration. Oscillometry was performed by an oscillotitrator Model OK-302/1 (Radelkis Electrochemical Instruments, Budapest). After measurements, the doses were evaluated from the previously determined calibration curves. For mercurimetric titration, the standardization of Hg+2 solution used for titration with standard NaCl solutions was performed daily before the analysis of irradiated dosimetric solutions. All doses were expressed as “absorbed dose to water”. For dosimetry calibration and “transit” dose measurements an ionization chamber type 2581 and a Farmer Dosimeter type 2570 (NE Technology Limited, England) were used. **Results**. Dose mapping in horizontal and vertical planes was performed with ECB dosimetry system, as follows: (a) The check for the angular symmetry of the radiation field was performed inside the annular space enclosed by the source rack. (b) The dependence of the dose rate *D* on the radius *r* from the axis of the cylinder was measured at two heights: at *h* = 0 cm, which is in the horizontal plane passing through the centre of the source cylinder and at *h* = 100 cm. (c) The dependence of dose rate *D* on the height *h* was measured at two radii: at *r* = 50 cm from the axis of the source, and at *r* = 100 cm from the axis, both in vertical planes through the axis. The “transit dose” was measured at different radii at *h* = 0. **Conclusion**. It was shown that the radiation field of the cylindrical gamma ray panoramic source is fully describable by using only two parameters, radius *r* from the axis and distance *h* from the reference horizontal plane. **Acknowledgment**: The support of the IAEA in ensuring timely supplies of radioactive 60Co over the years, especially through the recent Technical Co-operation Project CRO/1/006 (2014-2015) is gratefully acknowledged.
        Speaker: Ms Branka Mihaljević (Ruđer Bošković Institute, Croatia)
      • 127
        Dosimetric Characterization of the ISOGAMMA LLoCo Irradiator.
        All irradiation facilities must, before being put into operation, perform dosimetric characterization of the radiation field. This data obtained from the commissioning dosimetry is used to determine the irradiation times necessary so that irradiated products receive the required absorbed dose value, and establishes the facilities operational parameters, such as dose uniformity ratio, and maximum and minimum dose positions. The ISOGAMMA LLCo radiation facility at CEADEN had no such procedure carried out during commissioning by the manufacturer. Thus, it was necessary to perform dosimetric trials to characterize the dose distribution in the irradiation chamber of the facility, to contribute to the correct operation of the facility, and ensure the quality of future radiation process. The experimental measurement points were selected taking into account the geometry of the irradiation chamber and dosimeters were distributed in the areas where the maximum and minimum dose values were expected. Initially, the Fricke dosimetric system was used to determine dosimetric characterization, and considering the cylindrical geometry of the irradiation chamber and its dimensions, the chamber was divided into three study zones. The dosimeters were measured by using the spectrophotometric method. Later, the alanine-ESR dosimetric system was employed to determine the dose distribution and the chamber was divided into six study levels, and alanine dosimeters were measured by using the electron spin resonance (ESR) technique with MiniScope 400 equipment. In this experimental work, the dosimetric characterization of the ISOGAMMA LLCo radiation facility was measured with two different dosimetric systems. The measured dose distribution has a similar profile for both dosimetric systems and the highest dose values are observed in the central part of the radiation chamber and the lower dose values in the upper and bottom parts.
        Speaker: Mr Enrique Francisco Prieto Miranda (Centro de Aplicaciones Tecnológicas y desarrollo Nuclear. (CEADEN), Cuba)
      • 128
        Dosimetric Eevaluation in Industrial Gammagraphy Operations
        This work, we developed a dosimetry study in industry in order to examine the parameters influencing the operators dosimetry in Gammagraphy interventions. These parameters are determined in a description of the practice and are subject to individual measures in real working conditions, using TLD dosimeters for estimation of the whole body dose [HP10] and the extremities and bone surface dose [Hp0.07]. This approach established a dosimetric estimated including various phases of radiographic testing under real conditions of the intervention, but also during the phases of transport and handling Gamma radiography, in order to prevent and reduce the risk of exposure to these operators.
        Speaker: Ms Samira MIMOUNT (National Center of Energy Sciences and Nuclear Techniques (CNESTEN), Morocco)
      • 129
        Dosimetric Properties of MgB4O7:Ce and MgB4O7:Ce, Li for Thermoluminescence Dosimetry Applications
        Thermoluminescent dosimetry is known as a well-established technique for monitoring radiation dose in medical practices. Some most used thermoluminescent dosimeters (TLDs) are: LiF:Mg,Ti (TLD-100), CaF:Mn, CaSO4:Dy, Li2B4O7, and aluminophosphate glasses. Recent studies have demonstrated that borates can be very useful for TL dosimetry because their compounds may be more sensitive to radiation than the commercial dosimeters as TLD-100. Furthermore, compounds with boron-10 allow the detection of thermal neutrons (E <0.25 eV). They also have other good dosimetric properties, such as linear dose response over a large absorbed dose range, effective atomic number close to the human tissue, and a simple TL emission curve with a single peak. However, there is not much discussion about preparation routes for dosimeters based on borates and on and the structure of their compounds. Among these, we examined thermoluminescence properties of magnesium tetraborate doped with cerium (MgB4O7:Ce) and co-doped with lithium (MgB4O7:Ce,Li). Some important TL properties were investigated such as: dose response for gamma and beta, fading and kinetic parameters of TL curves. To study TL response, the material was investigated in pellet format (3mm of diameter) that were irradiated with sources of beta particles (90Sr/90Y) and gamma rays (60Co) with different absorbed doses. The TL responses were measured using an TL/OSL reader (TL/OSL reader Riso). The results showed that the materials have great potential for TLD dosimetry, presenting low fading of TL signal (< 3% in one month) and prevalence of first-order TL peak. The dose response curves also show that saturation occurs at higher doses (up to 1000 Gy) and the kinetic parameter shows TL curve follow kinetic of first order.
        Speaker: Ms Divanizia Souza (Universidade Federal de Sergipe, Brazil)
      • 130
        Effect of Gamma-Ray and Electron Beam Irradiation on Reduction of Graphene Oxide Suspension in Aqueous Alcoholic Solution
        Enormous scientific and technological progress has been in the application of graphene, since its unique properties were unearthed by Andre Geim and Konstantin Novoselov in 2004. To realize the commercialization of graphene, the cost-effective and scalable production has been of great important and still considered as one of key issues in the graphene community. In this context, the wet chemical method based on the reduction of graphene oxide (GO) has been the most popular way to produce graphene because it probably offers large scalability and production of solution-processable graphene that can facilitate its many applications. Thus, numerous chemical reducing agents-, heat-, and light-based reduction strategies has been numerously exploited. However, these strategies have such drawbacks such as a necessity of toxic and explosive reducing agents, high temperature processing, and less scalability. Hence, there still is a high demand for the development of a cost-effective and large-scale method. This research was aimed to investigate the reduction of GO suspension in aqueous ethanol (EtOH) through gamma-ray or electron beam (EB) irradiation with discriminable advantages as no need of reducing agent, room-temperature processing, and mass-producibility. For radiation-reduction of GO, a solution of GO suspension in 50 v/v% EtOH/water (H2O) prepared by diluting a 5 mg/ml GO solution in H2O was added to glass vial, sealed with a rubber septum, and purged with nitrogen gas. The resulting vials containing the GO suspension were irradiated at room temperature by gamma-rays from a Co source or EB from a 10 MeV UELV-10-10S electron accelerator located at Korea Atomic Energy Research Institute at the various absorbed doses ranging from 50 ~ 100 kGy. The dose rate for gamma-ray irradiation was 10 kGy and the scan rate for the EB irradiation was 10 kGy/min. The resulting reduced GOs (rGO) were systematically characterized in terms of optical, chemical, thermal, morphological and electrical properties. From the results of UV-Vis, FT-IR, TGA, and TEM analyses, it is clearly confirmed that GO suspension in aqueous EtOH was effectively reduced by gamma-ray and EB irradiation, and the thermal, chemical, and thermal properties of the resulting rGO was dependant on the absorbed. Noticeably, on the basis of the results of the electrical conductivity measurement, the rGO prepared by the EB irradiation exhibited similar magnitude of the electrical conductivity to that prepared by the gamma-ray irradiation at the same absorbed dose, indicating that the EB irradiation can reduce GO more quickly than the gamma-ray irradiation. In conclusion, the reduction of GO suspension in aqueous EtOH can be successfully achieved by both gamma-ray gay and EB-irradiation. More importantly, EB-based reduction is much faster than the gamma-ray irradiation. Therefore, this EB-irradiation reduction is promising for the cost-effective and large-scalable production of graphene.
        Speaker: Mr Seungho Yu (Korea Atomic Energy Research Institute, Korea, Republic of)
      • 131
        Electron Accelerator for R&D Study and Radiation Processing
        Upgrading of radiation facility located at Institute of Nuclear Chemistry and Technology (INCT) in Warsaw has been performed towards higher technical and economical effectiveness, better operational characteristics suitable for radiation processing and research programs. The radiation facility located at INCT was established in 1993, when 10 MeV, 10 kW linear accelerator powered by magnetron was installed in separate building and equipped with appropriate conveyer system. During facility exploitation the spare parts availability and cost become major problems to achieve continuous services required by facility customers. The objective of the project partly supported by IAEA was construction 10 MeV, 10-15 kW linear electron accelerator equipped with the microwave source based on TH 2158 klystron (Thales, France), and standing wave accelerating section (manufactured by NIIEFA, St Petersburg, Russia). The following stages of the design have been followed: electron gun, microwave system of accelerator, auxiliary systems including klystron stand, pulse power supply stand, driving generator stand and waveguide system, control, vacuum and water cooling systems. The triode electron gun with spherical impregnated cathode was selected as a source of electrons. The gun parameters were optimized to meet requirements of standing wave accelerating structure (distance between cathode and grid, distance between grid and anode, additional beam focusing to obtain proper beam dimensions). The nominal parameters of accelerator gun: 0,3 A; 50 keV; pulse repetition rate up to 300 Hz; pulse duration 20 µs. Fiber-optic synchronization and triggering circuit based on pulse generator as reference source were applied as triggering track of electron gun modulator, klystron modulator, and microwave amplifier. Klystron modulator was designed on the based of semiconductor switch (current load 1600 A, with voltage up to 18 kV). The modulator has been constructed to fulfill requirement of TH-2158 klystron including safety (shutdown) circuit for protection against current overload which may appear at semiconductor switch. The modulator is switched off, and modulator load current falls to zero if value of overload current surpasses 900 A. The microwave system of the accelerator is composed from standard S-band microwave including microwave isolator which was used to separate klystron against reflected wave after breakdown occurs in accelerating section. SF6 isolation gas is used in waveguide elements to improve isolation properties. The main accelerating section parameters are as follow: electron energy 10 MeV, energy spectrum ± 2 %, average beam power in the range 10-15 kW, pulse microwave power <5 MW, frequency 2856 MHz, electrical efficiency up to 58 %, electron beam capture coefficient up to 85 %, pulse output beam current 210 mA in nominal conditions. Accelerator control system is equipped with Siemens microprocessors and modules type Simatic S7-300, with communication channel Profibus and as SCADA tool (Supervisory Control And Data Acquisition) WinCC. The vacuum system consists of three ion vacuum pump type (pumping velocity 60 l/s) and turbomolecular vacuum pump which is used to start ion pumps at certain vacuum level. Accelerator is installed in vertical position and equipped with beam scanner 60 cm wide.
        Speaker: Mr Zbigniew Zimek (Institute of Nuclear Chemistry and Technology, Poland)
      • 132
        Electron Beam Techniques for Air Pollution Control
        Abstract Various technologies such as absorption, adsorption, incineration, biofiltration and advanced oxidation have been developed to treat air pollutants. However, these methods have some limitations such as a high pressure drop, short lifespan, large site, economics and formation of secondary pollutants. To solve these problems, recently, advanced oxidation processes have been studied. An electron beam (EB) technology is one of the most promising advanced technologies due to its special characteristics. The EB technologies for volatile organic and odorous compounds treatment are introduced in this paper. The removal efficiency of these compounds by an EB processing is discussed in diverse conditions, such as different initial concentrations, background gases, absorbed doses, relative humidities, etc. Furthermore, the characteristics and effects on new EB hybrid technologies designed to overcome problems of only EB system are reviewed. In additional, the limitations and potentials of EB technology for air pollution treatment are also discussed. Keywords: Electron beam; VOC; Odor; Irradiation; Absorbed dose; Acknowledgments The author would like to thank Clarian H. for her insightful contributions. This research was supported by the Nuclear R&D program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning.
        Speaker: Mr Seungho Yu (Koea Atomic Energy Research Institute, Korea, Republic of)
      • 133
        Enhancing Safety and Control Features of Radiation Processing Facility SIBO INRA/Tangier Morocco
        The automatic control system is one of the central parts of all irradiation facilities. The level of this control is always implemented to achieve strict safety procedures in routine facility use. However, sometimes the system is limited to the minimum legal regulation required due to economical restrictions; some commercial systems are generally made by manufactures of industrial facility and considered in the price of the irradiator. In some cases there is some specific irradiation facility with specific control system. For this kind of irradiator the control system can be developed and upgraded according to feedback from operating experiences and in accordance with industrial experiences. These upgrading procedures are also used as input by others to upgrade their systems. The objective of this paper is to share a local experience in upgrading the safety systems and special upgrading of $^{60}$Co for the irradiator. This work has been done with other works related to security and $^{60}$Co upgrading which are published in other scientific paper and concerns 1) Upgrading of $^{60}$Co in SIBO irradiator in Tangier (an operation made in collaboration with the IAEA and has been a success story of the year 2014 during the general conference of IAEA), and 2) Installation and upgrading of the security system in accordance with the Global Threat Reduction Programme to reduce the threat of a Radiological Dispersion Device (RDD) in collaboration with The United States Department of Energy’s National Nuclear Security Administration (NNSA).
        Speaker: Mr Mohammed MOUHIB (INRA Tanger, Morocco)
      • 134
        EPR Characterization of a Medical Grade Polyethylene for High Dose Dosimetry
        Background of the study The Quality Control of radiation processing of polymers and composites by electron beam (0.1-10 MeV), gamma and X-ray (0.6-7.5 MeV) can often be achieved by full knowledge of the irradiation parameters and by periodic analysis product. In such cases where the product itself is used for the quantitative control efficiency process other radiation dosimeters are not necessary. The main changes induced upon irradiation on the structure of the polymers are the creation of free radicals and the modification of the electronic configuration of these materials. The electronic paramagnetic resonance of the ionizing radiation induced free radicals in polyethylene has been extensively investigated by many authors. However, in the best of our knowledge, there is no data in the literature available regarding EPR dosimetric properties of the polyethylene. In this work we are interested in the free radicals induced by gamma and electron beam irradiation in a polyethylene in order to investigate its use as high dose dosimeter. Methodology The polyethylene samples were obtained from commercial medical grade polyethylene sheets of 28 microns thick and were cut into pieces of 30 mm x 4 mm dimensions for EPR measurements. The PE samples were subjected to different doses irradiation in air and in nitrogen at room temperature of Cobalt-60 gamma rays (5-118 kGy) and 2.2 MeV electrons beam (25-1000 kGy). The EPR measurements were recorded at room temperature by means of X-band Bruker EMX machine with a microwave frequency of about 9.5 GHz. Results and conclusion The EPR spectrum obtained immediately after irradiation consists of six lines with a small amount of an asymmetric component, the six-line spectrum is attributed to alkyl radicals (AR) and the unbalanced line spectrum is attributed to the peroxide radical (PR). The effect of increasing the dose of PE films was studied in the range 5-50 kGy. The intensity of EPR spectra increase with increasing dose. The dose response curve of AR follows a linear model, while the curve of evolution of PR follows a first order kinetics model. We observed a strong decrease of ARs during the first three days after irradiation followed by a slow decrease until their total disappearance after 9 days. The concentration of PRs increased significantly after irradiation to stabilize after 31 days. The PRs thus formed are interesting for dosimetry because there exist alone without overlapping with other radicals and it is stable. However, the very long time to stabilize at a disadvantage. We found that the PR is completely separable after annealing for 20 minutes at 100 °C. The repeatability of measurements for the two radicals has been proven. The coefficients of variation were found to be less than 1 %.
        Speaker: Mr Khaled Farah (Research Laboratory: Energy and matter. Development of Nuclear Sciences, National Center for Nuclear Sciences and Technology. 2020, Sidi-Thabet, Tunisia.)
      • 135
        EPR Dosimetric Potential of Ammonium Oxalate Monohydrate in Radiation Technology
        This study aims to examine the dosimetric properties of the of ammonium oxalate monohydrate (COONH4)2H2O under low and high radiation doses. The EPR spectra of ammonium oxalate have the spectroscopic splitting g-factors of 2.0095 and 2.0047. Results indicate that the dose-response curves have a good linearity in the range between 10-1000 Gy for low doses. Slight sub-linearity has been found in high dose region up to 25 kGy. The effects of temperature and humidity on the EPR signal amplitude of the irradiated samples are studied. Stability of the irradiation rods upon storage (signal fading) was also investigated. Energy dependence has been found within 38% at the range below 100 keV. Slightly energy dependence within 4% over the energy range 6 – 10 MeV has been recorded. The overall uncertainty of this dosimetry system is 4.64% (σ2) in low dose range and 3.67 % for the high dose range.
        Speaker: Mr Mohamed RUSHDI (Sudan Atomic Energy Commission, Sudan)
      • 136
        ESR Dosimetric Properties of Sodium Glutamate
        MONO SODIUM GLUTAMATE powder and rods (3x 10 mm) were studied to be a radiation sensitive material for ESR dosimetry. Samples were irradiated with 60Co γ- rays. The developed signal after irradiation increases with the increase of the mono sodium glutamate in the rods. The prepared powder can be used in the dose range from (10-90) kGy, whereas the rods are useful in the range from (10-120) kGy. The obtained number of free radicals per 100ev (G value) was found to be 0.201± 0.01. The g factor is 2.0113± 0.0001. The rods have the advantage of negligible humidity effects during irradiation. The pre and post irradiation stability was found to be satisfactory. Keywords: Mono sodium glutamate, Electron paramagnetic resonance, Radiation dosimetry.
        Speaker: Mr Seif Ebraheem Eid (National center for Radiation Research and Technology, Egypt)
      • 137
        Evaluation of Radiation Shield Integrity of DD Neutron Generator Facilities by Monte Carlo and Experimental Methods
        A new deuterium-deuterium (D-D) neutron generator has been installed for a wide range of applications. The generator is an excellent fast, epithermal and thermal neutron sources for laboratories and industrial applications that require neutrons with safe operation, small footprint, low cost and small regulatory burden. The generator has three major components: a Radio Frequency Induction Ion Source, a Secondary Electron Shroud, and a Diode Accelerator Structure and Target. Monoenergetic neutrons (2.5MeV) are produced with a maximum yield of 1010 n/s using 25-50 mA of deuterium ion beam current and a 125 kV of acceleration voltage. Detailed knowledge of the radiation dose rates around the neutron generator are essential for ensuring radiological protection of the personnel involved with the operation. This work describes the Monte Carlo and experimental studies carried out in the Neutron Generator facility of the National Center of Nuclear Sciences and Technologies (NCNST). Verification and validation of the shielding adequacy was carried out by measuring the neutron and gamma dose-rates at various locations inside and outside the neutron generator hall during the operational conditions and comparing with theoretical simulations. A successful operation of this generator will provide a convenient neutron source for basic and applied research at NCNST.
        Speaker: Ms Kaouther BERGAOUI (National Center of Nuclear Sciences and Technologies. Technopole Sidi Thabet, BP 72-CP 2020, Tunisia)
      • 138
        Facilitating Sustainable Education in Nuclear Science and Technology
        **Abstract:** Many e-learning tools are currently available for using in education. However, the environment for nuclear education is changing. Teaching methods and techniques have evolved and trends in enrolment into science and engineering studies. E-learning is regarded as the most modern and cost effective means to supplement traditional face to face education, and the way forward to provide more opportunities to access valuable information and knowledge regardless of time and place. In this paper, we review the new learning methodology, potential challenges of e-learning, the author e-learning tools and the different e-learning tools such as educational platforms, web based meeting. We also comment the most important aims of each tools and define the advantages and the disadvantages. Educational platform is effective in the e-learning development but does not provide social networks. However, the web based meeting is an innovative collaboration solution providing an exceptional experience with the simplicity of a web browser easily and naturally. the overall objective is to contribute to improving the sustainability and quality of nuclear education process and recommended best practices to improve efficiency and effectiveness
        Speaker: Mr Athmane ADJERAD (Nuclear Research Center of Algiers (CRNA), Algeria)
      • 139
        Feasibility of Using Irradiation to Degrade a Toxic Dye Compound
        Crystal Violet (CV), is widely used for dyeing cotton, silk and paper. It has carcinogenic and mutagenic effects other than antimicrobial properties. The toxicity of this wastewater represents a great risk to the ecosystem and need to be treated before being discharged into the environment. However, the complex aromatic molecular structures of CV make them more stable and more problematic to degrade. Therefore, the removal of this synthetic dye is of great concern because of the difficulty in treating such effluent by conventional methods. In this study gamma radiation was investigated as a method for removing CV from water. Absorbance, concentration, toxicity in eukaryotic cells and bacteria’s were analyzed. The CV solution (300 mg/l) in glass bottles were irradiated in a Cobalt-60 gamma-radiation facility. Absorbance (1/10 dilution) and concentration were measured in a UV-vis spectrometer. Cytotoxicity was tested in Vero Cells after 24 h of treatment with different concentration of CV solution irradiated. Cellular viability was determined with CV staining assays and absorbance analysis at 570 nm. Cytotoxic concentration 50% (CC50) was calculated comparing treated cells with cellular control. Antimicrobial susceptibility were analyzed using the NCCLS guidelines for the microdilution method and minimum inhibitory concentration (MIC) was defined. The absorbed doses of CV solution were 1.1, 2.2, 3.1, 4.5 and 5.2 kGy, the absorption spectra showed very small shift of the major peaks at about 300 nm and 580 nm but a reduction in the height as the dose increase, indicating that the concentration of CV is reduced. However, an small peak appears in the irradiated solution at 359 nm, indicating the possible formation of an intermediate metabolite 4,4`-bis(dimethylamino) benzophenone, as was reported by other authors. The absorbed dose strongly affects the degradation of CV in water, at 1 kGy 66% was still remaining, and 20% with 5.2 kGy (Fig. 1). The cell viability results from CV 0 kGy demonstrated the severe inhibitory effects by these chemicals; the CC50 was 8.8 mg/l. In contrast, the treatment of the solution with the incremental doses of gamma radiation reduced the toxicity. The results showed that with 1.1 kGy the CC50 was 85.6 mg/l and 109 mg/l for the solution treated with 5.2 kGy. Antimicrobial activity of the CV solution showed a reduction in a dose-based effect in all the microorganisms tested. *Staphylococcus aureus* MIC increase from 1.5 mg/l to 37.5 mg/l for the solutions 0 kGy and 5.2 KGy. Similar results were obtained with *Bacillus cereus* (6.25 to 100 mg/l) and *Escherichia coli* (50 a >150 mg/l). This study provided both, a reference for radiation degradation of CV without producing undesirable intermediate metabolites and an alternative treatment processes for dye wastewater.
        Speaker: Ms María Verónica Vogt (Comisión Nacional de Energía Atómica, Argentina)
      • 140
        Fungal Decontamination of Historical Oil Painting by Using Gamma Ray
        Preserving historic heritage is the duty of a nation that cares about its history. Canvas based paintings are mainly subject to fungal infestation under improper conservation conditions. The aim of this study was evaluation of optimal gamma ray dose for fungal decontamination of a historical oil painting in dimensions of 3.03m x 1.60 m of XIXth century stored in Melal museum of Saa d-abad Palace . Sampling was done from 31 points of the discolored points directly by wet sterile swab then surface cultured on SDA medium. Growth of fungi was determined after 8-12 days incubation in 29°C. Classification was based on overall morphological properties. Colors used were identified with infrared spectroscopy (mid and far regions). Type of canvas was identified by checking the fiber, type of burning, burning behavior when away from the flame, burning smell and ash type. Fungi resistance to irradiation was investigated on strips made of similar canvas painted with the same colors. Light-thermal aging of strips were done in a QUV/Spray device powered with fluorescent lamp with the emission maximum of 0.71 W/m2 for UVB 313nm , in 60 °C for 100 hours, 4 hours in 100%relative humidity in 50°C. Aged strips were inoculated with spore suspensions and exposed to 0.2-2 kGy of gamma rays from 60Co in GC220, dose rate of 2.08Gy/Sec calibrated with fricke dosimeters. Radiation survival spores were cultured and counted after 5 days. D10 was determined by graphing survival populations after a series of radiation dose. Irradiated strips with 5-25 kGy were subjected to sterility test. The minimum dose in which fungal growth is detected after 14 days of incubation in maximum two tests out of 20 was the sterilization dose. Sampling indicated that Penicillium and Aspergillus were common fungi of the front and the back and between canvas and the frame. Infrared spectroscopy revealed that burnt umber brown and vagone green earth were common colors used in the painting. Checking the fiber showed that linen was the board type. The mean D10 value of Penicillium crysogenumATCC12690 and Aspergillus niger CBS 104.57 on aged colored linen strips was 0.9-1 kGy. There were differences between D10 values on culture medium (0.41 and 0.34 kGy for Penicillium and Aspergillus respectly ) and canvas stips (0.9-1 and 0.9 kGy for Penicillium and Aspergillus respectly ) and no significant differences on aged and not aged strips. Aged strips showed better capacity for spore recovery (1.7%) comparing not aged (0.15%). This may be due to production of nutrition elements in ageing process. Sterility test indicated that minimal dose of 5 kGy was sufficient for sterilization of strips with 2.7 x 106 cfu of each fungus. The color measurement of aged and irradiated samples will be studied later. In conclusion and according to fungal contamination of the painting the dose of 5kGy is suitable for decontamination.
        Speaker: Ms Ramsina Betesho Babrud (Atomic Energy Organization of Iran, Iran, Islamic Republic of)
      • 141
        Gamma Radiation Induced Decoloration and Degradation on Aqueous Solutions of Indigo Carmine Dye
        The textile industry has long been one of the largest water users and polluters. Wastewater released by textile industries contains toxic refractory dye stuff at high concentration. Most of the dyes in the textile industry are non-degradable, therefore, effective treatment of dye waste effluent has not been achieved by ordinary processes. Ionizing radiation has been considered a promising process for the treatment of textile dye waste effluents. In this study, the possibility of using gamma rays to degrade or decolorize a reactive dye in water was investigated. A reactive dye Indigo Carmine in aqueous solutions was irradiated at doses from 0.1 to 5 kGy at 47.62 Gy/min dose rate. The change of absorption spectra, chemical oxygen demand (COD), and the degree of decoloration were examined. The absorption bands at 248, 285 and 606 nm decreased rapidly with increasing irradiation dose. The COD reduction for the dye solutions attended 90% at 5 kGy. Finally, a kinetic study based on spectrophotometric measurements showed that the degradation process is pseudo first order with an apparent constant kapp equal to 2.693 min-1
        Speaker: Ms AMIRA ZAOUAK (National Centre for Nuclear Science and Technology, Tunisia)
      • 142
        Gamma-Irradiation for Cultural Heritage – Treatment of Selected Fungi on Linen Textile
        **Background of the study.** A common carrier for paintings is glue-coated linen that is vulnerable to fungal biodeterioration. The study aimed to assess antifungal effect of gamma-irradiation doses and dose rates against naturally occurring mycobiota and artificially inoculated fungal colonizers common for cellulose materials like linen. The composition of natural mycobiota on glue-coated linen (initial level) and eventual post-irradiation recovery of mycobiota were analyzed. **Methodology.** The initial level of common fungal colony-forming mycobiota on model glue-coated linen textile was determined by plate count method upon 7 days of incubation (at 25°C and 70-80% r.h.) and the data expressed as the number of colony-forming units per gram (CFU/g). Next, linen samples were separately inoculated with selected primary (*Aspergillus jensenii*), secondary (*Cladosporium spaherospermum*) and tertiary colonizers (*Trichoderma harzianum*) at concentration of 10000 CFU/g. Inoculated linen and controls were incubated as described. One group of samples was analysed immediately upon the incubation while the rest of the samples were irradiated at 60-Co gamma source at RCDL to doses of 2, 7, 20 and 50 kGy, at dose rates of 0.1 and 9.8 Gy/s and analysed after incubation for 0, 7, 14 and 28 days. **Results.** *Alternaria* spp., *Aspergillus* spp., *Cladosporium* spp. *Fusarium* spp., *Penicillium* spp. and yeasts comprised naturally occurring mycobiota, in initial concentrations of 1000 CFU/g (moulds) and 10000 CFU/g (yeasts). These fungi were non-homogeneously dispersed on glue-coated linen. On incubation in humid atmosphere the concentration of mycobiota increased for four orders of magnitude. Similar increase was obtained for non-irradaited artificially inoculated samples. All applied doses and dose rates were effective against primary and tertiary colonizers but not for secondary colonizers and linen mycobiota. Doses of 2 and 7 kGy was ineffective in reduction of linen mycobiota to the initial level; after 28 days of incubation fungi were recovered up to 1000000 and 100000 CFU/g, respectivelly. Dose of 20 kGy (0.1 Gy/s) reduced *Cladosporium* spp., and *Alternaria* spp. to 10000 CFU/g; *Penicillium* spp. was reduced to the initial level while yeasts, *Aspergillus* spp., and *Fusarium* spp. recovered in concentrations below initial. For both 7 and 20 kGy dose rate of 9.8 Gy/s was more effective in fungal elimination than 0.1. Gy/s, while for 2 kGy the dose rate effect was inconsistent. Upon exposure to 50 kGy sterile white mycelia was recovered on few plates *C. sphaerospermum* survived radiation with 2, 7 and 20 kGy, showing the similar recovery pattern as obtained for *Cladosporium* spp. After treatment with 7 and 20 kGy (0.1 Gy/s) cladosporia recovered between 7th (or 14th) and 28th day in concentrations between 1000 and 1000000 CFU/g. The same doses applied at 9.8 Gy/s inhibited recovery of *C. sphaerospermum*. **Conclusion**. For successful gamma-radiation reduction of fungal contamination on cultural heritage it is essential to determine mycobiota composition and to irradiate at an appropriate dose rate.
        Speaker: Ms Maja Šegvić Klarić (Department of Microbiology, Faculty of Pharmacy and Biochemsitry, University of Zagreb, HR-10000 Zagreb, Croatia)
      • 143
        Gamma-Irradiation in Protection of Cultural Heritage – Effects on Model Cellulose Based Textiles
        Background of the study Cellulose-based textiles are very common materials in cultural heritage (CH) collections (garments, upholstery, etc) and in art (painting canvases). Natural textile fibers are susceptible to biologic damage particularly by insects and fungi what is a serious problem in the preservation of such CH objects. The canvases are commonly coated with animal glue what makes them more susceptible to fungal attack. Ionizing radiation has been recognized as a fast and efficient treatment of attack by living organisms, particularly insects. At Radiation Chemistry and Dosimetry Laboratory of Ruđer Bošković Institute radiation treatment of CH items is ongoing for about 25 years. Along numerous wooden, paper and leather objects textile artifacts mostly of ethnological significance, were efficiently disinsected by irradiation to 2 kGy or less. However, the application of higher doses needed for the control of fungi has to be justified particularly considering the effects on aged and deteriorated materials. Because of that this study is aimed to assess whether there are side-effects of the irradiation on cellulose-based textile fibers and to identify the type and the extent damage type if present. The role of glue-coating on radiation sensitivity of model canvases is also investigated. Methodology The study consists of two parts. The first part was intended to identify the effect of irradiation and ageing. A set of cotton and linen model textile samples were irradiated and a part was also artificially aged. Two gamma-irradiation doses were selected: 6 kGy that is often used in treatment of fungi and a much higher dose of 120 kGy that is not used in radiation treatment but is expected to cause detectable side-effects. The samples were irradiated in contact with air at the dose rate of 2.8 Gy/s. In a second part of the study linen samples as a model for painting canvas were coated with animal glue prior to irradiation. Those samples were exposed to a range of doses between 2 and 50 kGy at dose rates 0.1 and 9.8 Gy/s, also in contact with air. Before the post-irradiation analysis the glue was removed. The samples were studied by FTIR-spectroscopy, microscopy and thermal techniques. Results Slight changes due to irradiation of model cotton and linen textiles were observed only at the higher dose of 120 kGy but were comparable or lesser that those brought in by aging. Although the process of glue removal from model canvas samples might have somewhat obscured the results it seems that the coating reduces radiation sensitivity of model canvas. Conclusions Since doses up to 10 kGy are needed for control of the most common fungi on CH textile materials the results are encouraging. Efficient radiation treatment of fungal contamination should case no undesirable changes and thus be acceptable to conservator specialists.
        Speaker: Ms Irina Pucić (Ruđer Bošković Insitute, Croatia)
      • 144
        Human Resource Development for the Application of Radioisotope Techniques to Industry in Myanmar
        Competent and efficient manpower is one of the main sectors for the application of radiation science and technology. The Department of Atomic Energy (DAE) has been conducting E&T and R&D in nuclear application field, cooperating with local institutions and international societies. Two technological universities have been offering the academic programs for nuclear engineering (B.Tech, B.E, M.E and Ph.D) under the supervision of DAE. To have professional development, skill development and to have opportunities for career advancement and future job prospects, human resource development program in radioisotope techniques for the application to industry has being carried out through national TC project cooperating with IAEA since 2012. Radioisotope Techniques Laboratory was established under the Department of Atomic Energy to transfer technology and implement radioisotope techniques into a practice. Knowing the basic theory of gamma ray transmission, gamma column scanning and gamma computed tomography techniques were introduced to the students. The simulation of gamma column scanning is conducted by using model of distillation column made of iron. Two computed tomography system, GORBIT first generation CT system supported by IAEA and field-used BATAN CT system provide by BATAN, Indonesia, are used to practice the computed tomography technique. To conduct the experiment for radiotracer technique, in-house pipe line system and water flow-rig for simulation of chemical reactors provided by IAEA are used as compact and useful tools. Each of the tools has been adopted to the specific need of the country to achieve desired HRD results and to assist individuals in learning more effectively with the goal of improving performance. From the development of industry-driven education and training programs, students can develop designs and software adaptable for need in the application to local industries.
        Speaker: Ms Khin Ye Lwin (Department of Atomic Energy, Myanmar)
      • 145
        In-Situ and Non-Destructive Detection of Oleoresin in Standing Agarwood Trees Using Portable Gamma-Ray Tomography Imaging System
        Agarwood is known for its fragrant resinous wood. It is a rare and precious oleoresin on the planet, prized for its rich and wonderful fragrance and healing properties. Because of its high economic value, agarwood has been subject to intensive exploitation in South East Asia’s natural forest for hundreds of years. Consequently, agarwood-producing tree species have become extremely rare.The extinction threat to agarwoods is becoming more worrisome because their harvest is often done by trial and error; specifically, by cutting the standing trees without any reliable means to detect and confirm the presence of oleoresin. This practice is not only inefficient and technically and economically ineffective, but it also contradicts sustainable forest management principles. To decrease random harvesting, technological innovation is needed to detect the presence of oleoresin within the trees. Technology based on the measurement of energy gamma-ray attenuation to assess internal trunk or wood characteristics has been developed. The attenuation of gamma-rays is highly correlated to the atomic number and density of materials. The principle of this technology is based on measuring and recording the transmitted intensity of gamma rays that pass through the trunk of the tree. The transmitted gamma-ray intensities will differ depending on the density of the wood. Since the presence of oleoresin in agarwood changes the density of trunk wood, this technology can theoretically detect agarwood within a tree. A portable clamp-on gamma-ray tomography system, called GammaSpider, was designed and manufactured by scientists and technologists at the Centre for Computed Tomography and Industrial Imaging in Malaysian Nuclear Agency. This paper presents the results of tomographic imaging of several standing agarwood trees of different ages. In addition, the effectiveness of innoculation process to produce oleoresin was also evaluated. Computed tomography (CT) images of the samples were obtained at 1.25mm resolution. Besides a clear distinction between oleoresin, voild and wood fibre, some bright white areas occured in the reconstruction images caused by a denser medium component in the wood, apparently oleoresin deposits that attenuated the radiation. This technique demonstrates a potential application of gamma-ray computed tomography in the detection of oleoresin in standing agarwood trees. The development of GammaSpider was carried out in an attempt to provide an alternative non-destructive means to the conventional cutting methods for the detection of oleoresin in standing agarwood trees. The system has produced quality images with excellent contrast, which shows clear and correct representation oleoresin, void and wood fibre. From the CT images, the positions and extent of oleoresin could be precisely quantified. The scanner has been successfully used for non-invasive detection of oleoresin in agarwood trees in a number of field tests in plantations in Malaysia. The successful utilization of this innovative has been recognized both nationally and internationally, as GammaSpider has won a number of awards. The method offers great advantages for in-situ inspection of agarwood tress as compared to the conventional methods. Work is continuing on improvements to meet the demands of faster scanning.
        Speaker: Mr Jaafar ABDULLAH (Malaysian Nuclear Agency (Nuclear Malaysia), Malaysia)
      • 146
        Intergrating Management Systems to Good Irradiation Practices within a Framework of Social Responsibility
        For more than $50$ years, commercial radiation processing has been used for healthcare products, food and other applications with a main goal in common, which is adding value to products, achievable only if predetermined specifications are met. Technology, process control, standards, quality management systems and personnel training, are some of the many branches which constitute good irradiation practices which should lead to safe and quality products. The introduction of Management Systems for Facilities and Activities (IAEA’s GS-R-3), which through the integration of safety, health, environmental, security, quality and economic elements in a single structure, establishes requirements to be met in order to ensure the protection of people and the environment, enables irradiation facilities to work with unified objectives. The further incorporation of social responsibility principles into the overall management activities helps to increase credibility to society, and motivate and promote commitment of workers, an essential factor to develop safety and a good irradiation practice culture, by understanding actions generate impact on products, environment, organization, employees, community and other stakeholders. The implementation of social responsibility at CNEA’s irradiation facility (PISI) was originally set out with three main objectives: its integration to safety, health, environment, quality and good irradiation practices management systems; relationship consolidation with community and stakeholders; and as an instrument to deploy potentials in different areas by increasing its human capital. This process was divided into three phases. The research phase consisted in selection of the ISO 26000 standard; the identification of overall applicable regulatory framework, including international treaties and further evaluation of our degree of compliance; and formulation of an implementation plan. The training and awareness activities consisted of a thorough study of principles and core subjects defined in the standard. The planning of the application phase was based on the need to prioritize the increase of human capital as it is the main actor in PISI’s activities, which included training the senior management team to strengthen governance as well as activities to improve communications, relationships, teamwork, staff motivation and exercise of individual and group self-evaluation, and promoting participation in continuous improvement of processes. Other activities included worker’s biopsychosocial health care, the identification of stakeholders and expectations, and so on. Relevant results were the elaboration of a shared vision statement and values between members of PISI; strengthening of governance performance; increase of commitment; development of self-evaluation and communication tools; stakeholder’s map. Although societal impact is still not measurable, the implementation of social responsibility in a public domain irradiation facility is possible and replicable. Principles and core subjects are closely related and directly or indirectly contemplated in integrated safety, health, environment management, quality and good irradiation practices, and contribute to increasing cultures and consolidation of relationship with stakeholders.
        Speaker: Ms Andrea DOCTERS (Comision Nacional de Energia Atomica, Argentina)
      • 147
        Ionizing Radiation as a New Technique for Treating Sewage Wastewater and Sludge in Arid Regions
        The production of sewage water and sludge is continuously increasing as a result of population growth and industrial expansion. Utilization of sewage water and sludge without proper treatment can induce environmental pollution and human health problems. Treated sewage water could be considered as a water resource and treated sludge could be used as organic fertilizer and soil conditioner. This is particularly true in arid region, where water scarcity is a major problem for agriculture and the lack of organic matter and nutrients is the main feature of sandy soil. The reuse of treated sewage water and sludge can solve these problems. Sewage water and sludge contain several contaminants, e.g. pathogenic organisms, toxic organic pollutants and heavy metals, high nitrate and high BOD & COD. The convention methods of sewage water treatment (primary, secondary, tertiary) are not efficient in removing such contaminants. Sewage water and sludge were exposed to gamma radiation of Co-60 and electron beam of accelerator. Analysis of pathogenic organisms, heavy metals and toxic organic pollutants, before and after irradiation, was performed according to The Standard Methods for the Examination of Water and Wastewater. Results indicated that ionizing radiation is an effective method in treating sewage water and sludge. The potential effect of radiation includes pathogen disinfection, organic pollutants degradation and soluble heavy metals reduction. The best radiation dose for pathogens disinfection was 1 KGy and 6 KGy for sewage water and sludge, respectively. A reduction in soluble heavy metals was observed in sewage water and sludge as a result of radiation treatment. Degradation of toxic organic pollutants (PAH) in moist sludge reached 79% at 6 KGy gamma radiation dose. Irradiated sludge applied to sandy soil has increased crop yield, improved soil fertility (organic matter and nutrients), improved soil physical and chemical characteristics. In conclusion, radiation treatment is recommended as an innovative and reliable method to improve sewage water and sludge characteristics.
        Speaker: Ms Rawia El-Motaium (Egyptian Atomic Energy Authority, Egypt)
      • 148
        Kinetics of Free Radicals Decay Reactions in Cellulosic-Based Heritage Materials Disinfected by $\gamma$-Radiation
        Disinfection by $\gamma$-radiation of cultural heritage artefacts and archived materials has been successfully applied in recent years. Radiation processing used for cultural heritage disinfection has several advantages when compared to conventional methods (e.g., chemical gases) mainly related to the safety, efficiency, reliability, capacity, process time and safety for users and the environment. However, more research is still required to study undesirable effects (side-effects) which may appear in sensitive materials as a function of the absorbed radiation dose. Some conservators and restorers are frequently worried about possible long-term effects in irradiated materials (post-effects). During the irradiation process, some energetic and unstable chemical species called free radicals appear in the treated matter. They disappear in different ways, interacting either with each other or with the artefact compounds thus becoming responsible for disinfestation and irradiation side-effects. The kinetics of free radical decay reactions depend on the absorbed dose, the properties of irradiated material among others. In this study, contemporary paper samples were irradiated using $\gamma$-radiation from $^{60}$Co with different absorbed doses. The absorbed dose range was chosen taking into account the effective values to promote insect eradication, fungal disinfection and sterilization. The decay kinetics of the cellulose free radicals induced by irradiation was analyzed using electron paramagnetic resonance. Several spectra were obtained at room temperature for each applied absorbed dose immediately after irradiation as reference measurements. To understand the free radical decay process, additional spectra were obtained for different decay times up to almost $50$ days after irradiation. De-noising treatment of the original obtained spectra signals were performed using wavelets. Free radical populations, proportional to the spin concentrations, were found by integrating the electron paramagnetic resonance signal curves. Comparison of spectra was done by normalizing the calculated area corresponding to cellulose spin concentration, taking first measurement after irradiation as $100\%$. Further analyses and calculations were made to study the half-life and the kinetics models of the free radicals created. diffraction was carried out to identify crystalline phases and the effect of ionizing radiation on the crystalline structure of cellulose in paper. Scanning electron microscopy and scanning electron microscopy energy dispersive spectrometry were performed to analyze structure modifications induced by ionizing radiation, identifying cellulose fibre agglomeration zones and to quantify chemical elements. Results show that for the sterilization dose, $80\%$ of the cellulose free radicals induced by ionizing radiation disappear in almost $40$ days and for disinfection dose in $8$ days. It can be concluded that if no modifications (side-effects) appear in the irradiated material after the radical decay time, the material will stay stable for the remaining lifetime. Results showed that the proposed method using electron paramagnetic resonance is suitably to study the behaviour of radicals on cellulosic-based cultural heritage materials.
        Speaker: Mr Pablo Vasquez (Nuclear and Energy Research Institute – IPEN/CNEN, Brazil)
      • 149
        Measurement of Residence Time Distribution of Wastewater in a Constructed Wetland System Using Radiotracer Technique
        **1. Background of the study:** Constructed Wetlands (CW) are human engineered systems that utilize natural process for treatment of wastewater. They have been highly applicable in developing countries, due to their characteristics like utilization of natural processes, simple construction, operation and maintenance, process stability, and cost effectiveness. The design of constructed wetland requires multidisciplinary inputs involving biological and ecological sciences, aquatic chemistry, engineering hydrology and flow hydrodynamics. The CW are heterogeneous in nature. Thus, they are prone to show deviation in the designed flow pattern and residence time for the treatment of wastewater. The aim of the present study is to measure mean residence time (MRT) and flow patterns of CWs using radiotracer technique. **2. Methodology employed:** The wetland is 13.0 m long, 3.0 m wide and 0.7 m deep. The geometric volume of the system is 27.3m3. The system walls and bottom were lined to prevent leakage. The wetland has slope of 1% at the bottom and an average porosity of 52%. About 100 MBq of of Tc-99m (Half life: 6.6 h, Gamma energy: 139 KeV) as sodium pertechnatate used in each run. The radiotracer concentration monitored at different planes across the width and outlet using NaI(Tl) scintillation detectors were connected to a computer controlled data acquisition system (DAS) was set to record tracer concentration at an interval of every one minute at outlet and across the bed of the system. **3. Data analysis and Results** The RTD data was treated and analyzed using a RTD analysis software. The data treatment includes background subtraction, tail correction, radioactive decay correction, zero shifting, smoothing and normalization. The data was used to calculate MRT, dead volume of system and hydraulic efficiency of the plant. A four-parameter model i.e. tank in series exchanging with dead volume model prefixed with plug flow component was used to simulate the RTD data. **4. Conclusions:** Radiotracer experiments were successfully conducted in an artificially constructed wetland system and mean residence times and dead volumes were determined at different operating conditions. No bypassing/short-circuiting was observed in the CW. The proposed four parameter model was found suitable to describe hydrodynamics of wastewater in the wetland. The hydrodynamic parameters were indicating that CW works efficiently at bed height=0.6m, wastewater flow rate=2.3 m3/s and two point distributor geometry. However, the results of the study also indicate that on increasing the no of injection points, the efficiency of the CW will increase.
        Speaker: Mr Sunil Goswami (Isotope Production and Applications Division, Bhabha Atomic Research Centre, Trombay, India)
      • 150
        Measurement of Voidage/Holdup in Industrial Process Systems Using $\gamma$-Ray Densitometry
        Multiphase flow reactors are commonly used in industry. One of the requirements for the efficient operation of these reactors is to have intimate contact or mixing between the different phases. Any spatial nonuniformity of the phases will adversely affect the process efficiency. Therefore, it is important to characterize the void fraction and holdup, and their spatial distribution in multiphase flow reactors. The $\gamma$-ray transmission technique commonly known as $\gamma$-ray densitometry is one of the commonly used techniques for measurement of voidage or phases holdup in multiphase flow systems because of its noninvasive nature and applicability to opaque systems. In $\gamma$-ray densitometry, a collimated radiation source (usually $^{137}$Cs) and a scintillation detector are mounted in a horizontal plane across the diameter of the flow system under investigation. The narrow mono-energetic beam of the $\gamma$-rays with an incident intensity passes through the system (walls and material within the system). A fraction of the incident beam is attenuated within the system and the transmitted intensity of the $\gamma$-rays is recorded by the detector connected to a radiation counting system. Let us consider an industrial process system, i.e., gas-solid fluidized bed system and record intensity of transmitted $\gamma$-rays at three different conditions of operation, i.e., with empty system (with air), with solids and with two phase flow (fluidized condition), then the line averaged void fraction of the fluidized bed is estimated using equations detailed in $[1]$: The technique was used for estimating voidage/holdup in pilot-scale two phase flow systems, i.e., fluidized beds and bubble column reactor to evaluate mixing of the two phases $1,2$. The results of the studies helped to understand the flow dynamics of the phases and validate or improve the design of the system. $[1]$ S. Bhowmick, *et al.*, Ind. Eng. Chem. Res., **54**, \#46, 11653–11660, (2015).\ $[2]$ D. Mandal, *et al.*, Powder Technology, **226**, 91–98 (2012).\
        Speaker: Mr Harish Jagat Pant (Bhabha Atomic Research Centre, Trombay, Mumbai, India)
      • 151
        New Trend in Radiation Dosimeters
        Background: A radiation dosimeter is a device that measures exposure to ionizing radiation. It has two main uses: for human radiation protection and for measurement of dose in both medical and industrial processes. The personal ionizing radiation dosimeter is of fundamental importance in the disciplines of radiation dosimetry and radiation health physics and is primarily used to estimate the radiation dose deposited in an individual wearing the device. Workers exposed to radiation, such as radiographers, nuclear power plant workers, doctors using radiotherapy, those in laboratories using radionuclides, and HAZMAT teams (personnel specially trained to handle dangerous goods, which include materials that are radioactive, flammable, explosive, corrosive, oxidizing, asphyxiating, biohazardous, toxic, pathogenic, or allergenic.) are required to wear dosimeters so a record of occupational exposure can be made. Such devices are known as "legal dosimeters" if they have been approved for use in recording personnel dose for regulatory purposes. Dosimeters can be worn to obtain a whole body dose and there are also specialist types that can be worn on the fingers or clipped to headgear, to measure the localized body irradiation for specific activities. The aim of this study is to identify and highlight the new technology in the types of radiation dosimeters. Method: The study comprises a personal selection of recent reports from radiology journals and the results of Medline searches which highlighted the new trend in radiation dosimeters. Results and Conclusion: Radiation dosimeters and dosimetry systems come in many shapes and forms, and they rely on numerous physical effects for storage and readout of the dosimetric signal. The four most commonly used radiation dosimeters are: Ionization chambers; Radiographic films; Thermoluminescent dosimeter systems (TLDs); Silicon diode dosimetry systems (Diodes). However, there are a variety of electronic personal dosimeters, extremity dosimeters, and comprehensive dosimetry management systems to monitor the exposure to ionizing radiation at any work environment. It can get an effective dose monitoring when and where we need it. Electronic dosimeters protect the wearer from the harmful effects of radiation by tracking changes in exposure and keeping an ongoing record of the user’s dose over time. Combined with access control systems, it is possible to limit total exposure to radiation and control access to radiological areas. Dosimetry readers, Ensure accurate radiation exposure monitoring. Manual and automated systems for whole body, extremity, neutron, and environmental monitoring are easy to operate, service, and maintain. Extremity dosimeter is a disk dosimeter designed for nuclear power or nuclear medicine personnel that have a high risk of exposure to ionizing radiation, particularly on their hands, due to their work in close proximity to radiation materials and radiation producing equipment. Keywords: Radiation dosimeter, Electronic dosimeters, Extremity dosimeter.
        Speaker: Ms Aya ABAZA (Egyptian Nuclear and Radiological Regulatory Authority (ENRRA), Egypt)
      • 152
        Non Destructive Radiation Dosimetery Using Diffuse Reflectance Spectroscopy
        Ultra-high molecular weight polyethylene (UHMWPE) is one of the polymers belongs to polyethylene (PE) family having monomer –CH2– and average molecular weight is approximately 3-6 million g/mol. Due its chemical, mechanical, physical and biocompatible properties, it has been extensively used in the field of electrical insulation, medicine, orthopedic, microelectronics, engineering, chemistry and the food industry etc.In order to alter/modify the properties of UHMWPE for particular application of interest, certain various procedures are in practice e.g. treating the material with high energy irradiation like gamma ray, e-beam, and ion bombardment. Radiation treatment of UHMWPE induces free radicals within its matrix, and these free radicals are the precursors of chain scission, chain accumulation, formation of double bonds, molecular emission, crosslinking etc. All the aforementioned physical and chemical processes are mainly responsible for the modification of polymers properties to use them in any particular application of our interest e.g. to fabricate LEDs, optical sensors, anti reflective coatings, polymeric optical fibers, and most importantly for radiation dosimetry applications. It is therefore, to check the feasibility of using UHMWPE for radiation dosimetry applications, the compressed sheets of UHMWPE were irradiated at room temperature (~25°C) for total dose values of 30 kGy and 100 kGy, respectively while one were kept un-irradiated as reference. Reflectance data (from 200 nm to 1200 nm) of gamma ray irradiated UHMWPE were measured by using diffuse reflectance spectrometer setup. As a result significant changes occur in the absorption behavior of irradiated samples. To analyze these (radiation induced) changes in polymer matrix Urbach edge method and modified Tauc’s equation has been used. The results reveal that optical activation energy has the direct relation with absorbed radiation dose. A similar trend was found for direct and indirect energy band gaps with irradiation due to variation of C=C unsaturation in clusters. We believe that the reported results would open new horizons for radiation dosimetery applications.
        Speaker: Mr Sajjad Mehmood Mehmood (University of Engineering and Technology, 47050, Taxila, Pakistan)
      • 153
        Optimal Design of Co-60 Single Source Radiation Facility with Monte Carlo Method
        Reference radiation field is necessary for calibration of radiation dose monitoring meters, and Co-60 single source radiation facility is an important equipment to produce reference radiation field. Uniformity and scattered photons are the most important criterions for reference radiation field. Monte Carlo method was used to calculate the uniformity and scattered radiation of the reference radiation field which was produced by Co-60 single source radiation facility. A close-to-reality simulation model of the facility was used for calculation scattered air-kerma along the whole range of source-detector-distance (SDD) along the central beam and air-kerma off-axis beam profiles at 1m source-detector-distance (SDD). Other characteristics such as the individual contributions of photons scattered in collimator, floor, walls, mobile platform and other parts of the radiation halls to the total air kerma rate on the beam axis were calculated. Optimal design of Co-60 single source radiation facility was accomplished according to the simulation results. PTW ionization chamber was used to measure the radiation field produced by Co-60 single source radiation facility, measured results show that the scattered radiation and uniformity of the radiation field are in good agreement with the simulation results. The total scattered contribution is less than 4.0%, fulfills the ISO 4037-1 requirement of a maximum scatter of 5%. The Co-60 single source radiation facility performances meet the design requirements.
        Speaker: Mr Fei Gao (China Institute of Atomic Energy (CIAE), China)
      • 154
        Optimizing the Size and Composition of Solid State/EPR Dosimeters
        In the last few decades alanine/ Electron paramagnetic resonance (EPR) dosimetric system has been accepted by International Atomic Energy Agency as secondary, of transferring type, dosimetric system. In order to increase the sensitivity of solid state/EPR (SS/EPR) system up to now several materials have been studied. The sucrose has been studied for a long time as a dosimeter in radiation accident and in high-dose dosimetry by using different analytical techniques. On the other hand optimization of the shape and size of the dosimeters may increase the sensitivity of the system. In the current study, an attempt to improve the sensitivity of the SS/EPR dosimetry is made. In view of this cylindrical dosimeters with different diameters and in presence and absence of internal standard Mn/MgO2 have been prepared and tested. As radiation sensitive materials in the dosimeters were used sucrose and alanine. The influence of the diameter of cylindrical dosimeters on the EPR response was studied at 1 mW microwave power and 0.2 mT modulation amplitude, in other to avoid some interference of the instrumental parameters. At absence of Mn in MgO2, the intensity of the EPR signal increased with increasing of the diameter of the dosimeters at the equal doses. It is normal because the quantity of the material increases. In the samples composing internal standard the ratio of the EPR intensity of the signal (Is) to intensity of the manganese standard (IMn) is used. In this case the EPR response is independent of the diameters of the dosimeters. The effect of size and composition of dosimeters used in SS/EPR dosimetry on their response also is studied. It has been found that in absence of internal standard Mn/MgO2, the EPR intensity increased linearly with the absorbed dose up to 20 kGy after that it is saturated. In dependence on the diameter of dosimeters the slope is different. It is biggest in case of 3 and 4 mm diameter. Further increase of the diameter of the dosimeters is not recommended since the increased penetration of the dosimetric material into the electric component of the microwave field in the EPR cavity decreases the EPR response. In presence of internal standard (Mn/MgO2) into the dosimeter (so-called self-calibrated dosimeter) the EPR signal intensity increased linearly with the dose in the all investigation region of dose (3-80 kGy). It can be concluded that the best results give self-calibrated cylindrical dosimeters.
        Speaker: Ms Yordanka Karakirova (Bulgarian Academy of Sciences, Bulgaria)
      • 155
        Personal Radiation Dosimetry at Radiological Facilities, Nepal
        The saga of using ionizing radiation is long back in Nepal especially in medical sector. With the introduction of radiation therapy and nuclear medicine, it has been felt the need of monitoring occupational radiation exposure. Only few hospitals three to four are monitoring their staff by sending thermoluminescent dosimeter (TLD) badges to Bhabha Atomic Research Centre, Mumbai, India. Over 95% radiation workers are never been monitored for their radiation dose. However, it is a mandatory by ILO that every radiation worker should be monitored for his/her radiation dose. To meet this requirement from the overwhelming requests from various hospitals, Nepal Academy of Science and Technology (NAST) initiated this work in 2013 and getting materialized recently through the assistance provided by the IAEA. Government of Nepal has assigned NAST to provide the dosimetry service for radiation workers in Nepal. For this service, a dosimetry setup comprising a Harshaw 6600 Plus TLD Reader along with TLD cards (TLD 100 LiF:Ti.Mg) has been installed just in the last December 2015 at Physical Science Laboratory, NAST. The complete dosimetry system has become operational only in March 2016 with the help of IAEA expert mission. Under a test service, Manamohan Memorial Cardiovascular and Transplant Centre (MMCTC) was chosen where 22 TLD cards were earlier provided to the personnel to wear the card and the cards were read out for dose assessment. The first personal dosimetrty report for one month was issued in March 2016 for this hospital. The penetrating dose Hp(10) and skin dose Hp(0.07) of individuals have been shown in the Fig.1. The absorbed dose distribution of personnel show that few radiation workers received significant radiation in that duration.
        Speaker: Mr Buddha Ram Shah (Faculty of Science,Nepal Academy of Science and Technology, Nepal)
      • 156
        Pilot-Scale Study of the Radiation-Induced Silica Removal from Underground Brackish Water in Saudi Arabia
        Background of the study: Brackish underground water desalination is the second main water supply, after seawater desalination, used in the Kingdom of Saudi Arabia. Most of the inland cities and villages rely entirely on this supply mode for their domestic industrial and agricultural purposes. High silica concentrations are found in these waters and can cause an excessive and recalcitrant deposit on the membrane fouling in the reverse osmosis (RO) units. This membrane fouling is a worldwide problematic issue in the cost-effective operations in water desalination plants. Methodology: In this work, we investigated the effectiveness of the gamma radiation induced removal of silica in water sample from the Salbukh water treatment plant (near Riyadh, Saudi Arabia). A cobalt-60 source was used to gamma-irradiate the acidic pH solution containing silica mixed with metal iron powder and saturated with oxygen pure gas before irradiation. The radiolytically produced hydroxyl radicals OH● oxidize the iron metal into ferric ions which co-precipitate with the silica resulting in the removal of this latter. Results: The influence of several reaction parameters i.e iron powder dosage, radiation dose, initial pH and equilibrium pH effects were investigated. The removal increased with the irradiation dose and reached a plateau at 350-400 Gy. For a percentage removal as high as 75% obtained in this work, the optimal conditions of the main reaction parameters studied here, were the following: • the optimum initial pH is 2 – 3, • the removal increased with increasing pH up to the pka of the silicic acid. • Fe0 dosage: 8 g/l. Conclusion: This preliminary study showed that this environmentally friendly gamma radiation process is effective in silica removal from underground water. This process could be implemented in arid regions in Saudi Arabia, where population has a limited access to fresh water.
        Speaker: Mr Fathi Djouider (King Abdulaziz University, Jeddah, Saudi Arabia)
      • 157
        Radiation Activities at ENEA Calliope Gamma Facility
        Since the eighties, the Calliope gamma irradiation facility (Casaccia R.C., Rome, Italy) was deeply involved in many research activities, in the framework of international projects and collaborations with industries and research institutions, focused on the investigation of gamma irradiation effects on chemical and physical properties of different materials. The Calliope Facility, located in the ENEA-Casaccia Research Centre, is a pool-type irradiation facility equipped with a 60Co γ cylindrical source array (mean energy of 1.25MeV) in a high volume (7.0×6.0×3.9 m3) shielded cell. The plant is equipped with dosimetric services and a monitoring system for logging the irradiation time, that allow to calculate the absorbed dose in materials due to the irradiation. Available dosimetric systems include Fricke, Red-Perspex, alanine-ESR and TLD. Different irradiation dose rates, from zero to a maximum of some kGy around the rack longitudinal axis, are available by placing the sample in specific position within the irradiation cell. The irradiation tests could be carried out in air, under vacuum or under inert atmosphere. Several researches and qualification activities, in compliance with the international standard specifications, were carried out at the Calliope facility. Irradiation and dosimetric certifications are issued by the Calliope facility after each irradiation test. Qualification tests are mainly performed on electronic components and devices for application in hostile environment such as nuclear plant and aerospace and on concrete matrices for nuclear waste disposal and storage. The Calliope facility is indicated by the Italian Space Agency ASI as ASI Supported Irradiation Facility (ASIF), recommended by the European Space Agency ESA. Synthetic and natural polymeric materials used in many fields (e.g. nuclear and space application, medical devices, food packaging, cultural heritage) are studied in term of gamma irradiation induced processes (cross-linking and degradation). Their behavior is evaluated in different atmospheric conditions (air, vacuum or inert gases), paying particular attention on the irreversible modification occurring during or after the end of gamma irradiation. At the Calliope laboratory, biological researches for the conservation and preservation of cultural heritage archived materials (books, images) are related to the bio-deteriogen eradication assisted by gamma radiation and to the assessment of the recovery procedures. Other biological studies are related to the agriculture and the environmental, such as biological control of pests assisted by gamma irradiation (SIT, Sterile Insect Technique) and agricultural product treatments. Activities concerning polymers and biological applications on cultural heritage are carried out in the framework of IAEA Coordinated Research Project F23032 (Research Agreement No.18922/RO, 2015-2019). The Calliope facility laboratory is equipped with several instruments for the evaluation of scintillating material performances by optical (UV-VIS and FTIR spectrophotometer, luminescence measurements), spectroscopic (ESR spectrometer) and Light Yield measurements in term of number of photoelectrons emitted per unit of the absorbed energy (MeV). Great expertise has been achieved on radiation detectors, optical components and scintillators (optical fibers, crystals and glasses) applied in High Energy Physics experiments, such as CMS ECAL experiment at LHC CERN and Belle II experiment at SuperKEKB (Japan).
        Speaker: Ms Alessia Cemmi (ENEA, Italy)
      • 158
        Radiation Induced Environmental Remediation of Toxic Cr(VI) Heavy Metal in Aerated Neutral Solution under Simulated Industrial Effluent
        Radiation induced environmental remediation of toxic Cr(VI) heavy metal in aerated neutral solution under simulated industrial effluent Background of the study: Chromium(VI) heavy metal is a major water contaminant in most industrial effluents, due to its carcinogenicity and its impact on ecosystems, while Chromium (III) is non-toxic and is an important element for human metabolism. Cr(VI) can be reduced to Cr(III) by the superoxide O2ˉ• free radical radiolytically produced in aerated solution at neutral pH in the presence of formate. Methodology: The degradation of Cr(VI) was investigated by steady state gamma irradiation using a cobalt-60 source and by pulse radiolysis using a van de Graaff accelerator in aerated solution at neutral pH, which is close to natural conditions in most wastewaters. Results: The degradation of Cr(VI) increased linearly with the absorbed dose and was significantly enhanced by the added formate but not by the radiolytically produced hydrogen peroxide at this pH. The rate constant for this reduction was found to be 1.28 x 108 M-1 s-1 and the absorption spectrum of Cr(V) transient species was obtained. A partial recovery of Cr(VI) is observed over a period of ca. 5 ms following a second order kinetics with a rate constant 8.0 x 106 M-1 s-1. Conclusion: These outcomes suggest that gamma-irradiation of Cr(VI)-contaminated wastewaters and industrial effluents in presence of formate can be simple, effective and economical means for the remediation of this major contaminant.
        Speaker: Mr Fathi Djouider (King Abdulaziz University, Jeddah, Saudi Arabia)
      • 159
        Radiation Shielding Analyses of A 10 MeV LINAC for Electron Beam and X-Ray at KACST
        The King AbdulAziz City for Science & Technology (KACST) in the Kingdom of Saudi Arabia plans to build a 10 MeV, 15kW LINAC for electron beam and X-ray applications. The design and construction of the accelerator building will be conducted in the cooperation with KACST and EB Tech Co., Ltd. This report presents the shielding analysis of the accelerator building using the MCNP Monte Carlo radiation transport code. In order to improve the accuracy in estimating deep radiation penetration and to reduce computation time, various variance reduction techniques, including the weight window (WW) method, DXTRAN spheres were considered. Radiation levels were estimated at selected locations in the shielding facility running MCNP6 for particle histories up to 1.0x10+8. The final results indicated that the calculated doses at all selected detector locations met the dose requirement of 50 mSv/yr, which is the US NRC requirement.
        Speaker: Mr Wong-Gu KANG (EB TECH Co., Ltd., Korea, Republic of)
      • 160
        Radiolysis Induced Degradation of Fluoroquinolones
        Background of the study ----------------------- The fluoroquinolones are synthetic antibiotics and inhibit very effectively gram-negative bacteria. These antibiotics do not totally degrade during the common wastewater treatments, hence, they can be released in the environment. Some compounds especially fluroquinolones can be hazardous even in small concentrations to the aquatic environments and ecosystems. The environmental exposure of the fluoroquinolones can lead to bacterial resistance. Because these compounds do not degrade during the common wastewater treatments radiolysis as an advanced oxidation process was investigated. Methodology ----------- Gamma radiation induced degradation of two frequently used fluoroquinolone antibiotics, ciprofloxacin and norfloxacin was investigated with UV-Vis spectrophotometry, with HPLC-UV and with organic sum parameter measurements (chemical oxygen demand (COD) and total organic carbon (TOC)). The samples were irradiated with doses between 0.2 and 10 kGy. The HPLC analysis was performed on a C18 column, with gradient elution and with diode array detection. In the case of UV-Vis spectrophotometry the solutions were saturated with nitrogen, air or dinitrogen-oxide before the gamma radiation. In some cases *tert*-butanol was applied to scavenge the hydroxyl radicals. At the measurements of organic sum parameters and the HPLC analysis the fluoroquinolone solutions were saturated with air. The degradations of ciprofloxacin and norfloxacin were also investigated with pulse radiolysis technique. Microsecond pulse radiolysis experiments were performed with 4 MeV accelerated electrons, with electron pulse length of 800 ns. The detection was kinetic spectrophotometric. An optical filter was used because of the bleaching below 400 nm in the case of fluoroquinolones. Transient absorption spectra of the intermediates produced by reactions with hydrated electrons were calculated. Results ------- The hydroxyl radical induced degradation was the most efficient comparing to the other reactive radicals like hydrated electron and hydrogen atom formed during water radiolysis. The reaction with hydrated electrons was also effective, in this case yellow degradation products were formed. Based on literature these products were presumably isatin analogues. The COD values decrease approximately linearly with the dose. The decrease was faster for low doses, presumably because the more easily degradable compounds degrade first. The TOC values decreased also approximately linearly with the dose and the results in case of ciprofloxacin and norfloxacin were very similar. HPLC analysis with diode array detection showed that three intermediates were produced by gamma radiolysis. The parent compound and one of the intermediates were totally degraded, and two other intermediates were partially degraded with the increasing dose. The concentration of the parent compound decreased strongly with the absorbed dose. Pulse radiolysis experiments showed that hydroxyl radical reacts with the parent compound and one radical intermediate was produced during 5 µs, and then it degraded. In the case of hydrated electrons, presumably two radical intermediates were produced, and then it degraded in microsecond timescale. Conclusion ---------- The experiments showed that the degradation and mineralization of fluoroquinolones linearly depends on the absorbed dose. The removal of fluoroquinolones from water was effective in the case of gamma radiolysis and also in the case of pulse radiolysis.
        Speaker: Ms Anna Tegze (Óbuda University, Hungary)
      • 161
        Relevant Safety Aspects for Radioactive Tracers in Industrial Process
        **BACKGROUND** The use of radiotracers plays an important role to provide methods to optimize industrial process and improve product quality. An increase in the use of radiotracers investigations has been observed in Brazil, however, as there is no specific standard for the licensing of these facilities, generic radiation protection regulations have been used, but these are not comprehensive or technically suitable for this purpose. Regulatory inspections carried out in radiotracer facilities have reported failures in disagreement with best practices for radiological safety, mainly in radioactive waste management and in the control of workplaces during radiotracer injections. In this work, an assessment of radiation protection aspects of radioactive tracers, not covered by generic regulations, is presented, with the aim of contributing to the future development of specific safety regulations in Brazil. **METHODOLOGY** The study is based on an assessment of the licensing process of facilities using radioactive tracers in Brazil, as well as the experience of regulatory inspections carried out at facilities using radiotracers and a review of international standards, in order to point out relevant radiation safety aspects in the establishment of regulatory standards for working practices, procedures and protective measures before, during and after injections of radioactive tracers. **RESULTS** Among the relevant key aspects and actions for radiological protection in radiotracer investigations, we can point out: 1. Detailed radiological protection procedures, including storage,should be elaborated for operations before, during and after injection, taking into account: - The different radiotracer injection strategies; - The available monitoring and decontamination equipment; - The complete injection apparatus should be checked for proper functioning including pressure tests before tracer injection. - A water injection through the injection apparatus and connected equipment should be performed for an extended period to clean out any contamination traces before disconnecting injection apparatus. 2. The facility should have a Radiation Safety Officer (RSO) certified by the Regulatory Authority, specifically for radiotracer applications. The RSO should not be subordinate to operational groups. 3. Personal alarm monitors should be mandatory for each radiotracer worker; for non-uniform exposures, it may be necessary to wear additional dosimeters for hands or fingers. 4. Survey tests should be performed in order to ensure successful decontamination in all areas that have been contaminated by radioactive material. Equipments that cannot be decontaminated at the jobsite should be properly packaged and sent to the field station for further cleaning or storage. Additionally, calculations should also be made on the impacts of any possible discharge into the environment, identifying the exposure pathways in order to ensure agreement with authorized limits of national regulations. **CONCLUSION** The lack of a specific regulatory standard for the licensing of radioactive tracers operations in Brazil weakens the nuclear regulatory body in its aim of regulating and licensing the activity. In this study recommendations are presented concerning relevant aspects of radiation protection for radiotracer applications, discussing specific features that should be part of the future regulations, with the purpose of ensuring safety during radiotracer investigations.
        Speaker: Ms Mara Lucia Costa (Brazilian Nuclear Energy Commission, Brazil)
      • 162
        Research on Conversion of Natural Wastes to Useful Products by Application of Radiation Processing for Agricultural Sector of Myanmar
        Myanmar is an agricultural-based country and its economic development mainly depends on productivity of agricultural sector. People are trying to improve their productivity by using variety of fertilizers. Some kinds of fertilizers cause decline of soil fertility and rest of fertilizer in food that are the main problems for our country. Moreover, temperature of our country is increasing yearly due to global warning. It is also challenging for our agricultural sector since water is essential for agricultural sector. Radiation technology can be used to produce useful products to solve these problems and the main aim of the research is to produce plant growth promoter and super water absorbent from natural wastes by application of gamma radiation. Myanmar has many stream and rivers as well as coconut trees are available in all part of country. Therefore, natural wastes such as prawn shell and coconut (coin dust) shell were used as raw materials. The first step for the production of irradiated chitosan (plant growth promoter) is deproteinization and deminerization processes. Effect of concentration of sodium hydroxide and temperature on deproteinization process and effect of concentration of hydrochloric acid at ambient temperature on deminerization process were studied. Characteristics of products are determined by Fourier Transormed Infrared Spectroscopy (FT-IR). The best chitin was used for the production process of chitosan in which different radiation dose and different concentration of sodium hydroxide were applied to obtain optimum condition for the deacetylation process. The degree of deacetylation (DD) was determined by band ratio method of FT-IR spectra. It was found that the degree of deacetylation (DD) of chitosan decreased with increase of radiation dose. Coir dust cellulose was produced from coin dust shell by using soda process in which various concentration of sodium hydroxide and various temperatures were used to determine the best cellulose. The product cellulose was applied for production of super water absorbent by using potassium hydroxide, acrylic acid and gamma radiation. Effects of acrylic acid concentration and radiation dose on product SWA were studied and determinations of their characteristics were done. Characteristics of cellulose and super water absorbent were determined by Scanning Electron Microscope (SEM) and Fourier Transormed Infrared Spectroscopy (FT-IR). It was noticed that useful properties of SWA increased with radiation dose. Production of useful products such as plant growth promoter and super water absorbent for agricultural sector were studied in the research. Field or pot test of the two products will be studied. It can be concluded that the research is effective not only for agricultural sector but also for environmental monitoring since raw materials used in the research were natural wastes. Keywords – plant growth promoter, super water absorbent, acrylic acid, Fourier Transormed Infrared Spectroscopy (FT-IR), Scanning Electron Microscope (SEM)
        Speaker: Ms Khin Khin Lay (Department of Nuclear Engineering, Mandalay Technological University, Mandalay, Myanmar)
      • 163
        RI-Biomics Technology for the Advance Radioisotope Application in Modern Life
        The RI-Biomics Center opened at ARTRI in the fall of 2013, and is a facility dedicated to improving the quality of life by developing advanced radioisotope applications in domains from basic biological sciences to the pharmaceutical industry. The RI-Biomics Center supports the research interests of a wide range of investigators from multiple disciplines, including academic biomedical sciences and the pharmaceutical industry, to elucidate the phenomena of life and evaluate the pharmacokinetics of drug candidates and medical bio-materials. We designed, build, and have put into routine use a radioisotope based total analysis system to handle the needs of a wide range of experiments from classic $^{3}$H, $^{14}$C based pharmacokinetic studies to small-animal molecular imaging studies using micro-SPECT/CT/PET, $7.0$ T small-animal MRI, fluorescence optical imaging devices and autoradiography, etc. The centre was designated as an Advanced Research Center for Nuclear Excellence in 2012 for development of RI-Biomics Bio-sensing application technology such as evaluation technology of life phenomena using 3D-ADMET(3-dimensional absorption, distribution, metabolism, excretion, toxicity study as advanced pharmacokinetic research), development of high value drug/functional food/medical devices or materials as well as advanced technology including GLP-like non-clinical study for the contribution on the improving quality of human life. The goal of RI-Biomics technology is to contribute to the peaceful application of radiation and radioisotopes through the development of advanced technologies for enhancing understand life phenomena. In pursuit of this goal our research focusses on the development of new technologies such as: a) SPECT/PET based 3D-ADMET study and classic $^{14}$C/$^{3}$H based ADME study for support the pharmacokinetic information of new drug or toxicant from small synthetic chemicals to big biologics such as antibody, biomolecules, nano-materials and polymers); b) Radioisotope based biosynthesis of high value herbal resources used to alternative medicine to support the advanced evaluation for traditional medicines; c) Study of radiation effects on the living organisms such as microorganisms, cells, plant and experimental animals such as fishes and rodents; and d) Development of experimental systems for the study of radiation or radioisotope application such as screening the highly radiation-sensitive experimental animals, etc. In addition, we are involving the professional and public education systems with the University of Science and Technology (UST), Korea Association for Radiation Application (KARA) and National Research Foundation of Korea (NRF), etc., to contribute the enhancing public acceptance for radiation. In the future, we will start a programme sharing the effects of radiation on living organism and environment to enhancing the public acceptance of nuclear & radiation technology. After the Fukushima Daiichi nuclear disaster the public were seized with fear surrounding nuclear and radiation application. Currently we propose convergence research to enhance the public acceptance.
        Speaker: Mr Beom Su Jang (Advanced Radiation Technology Research Institute, Korea Atomic Energy Research Institute, Korea, Republic of)
      • 164
        Setting up of New Radiation Facilities in Alexandria, Egypt
        The Gamma Irradiation Facility (400.000 Curie) from Isotope Hungry is the only unit in Alexandria capable of sterilizing medical and agricultural products as well as industrial irradiation research and applications. The activity of Gamma Co-60 Facility could be increased to (2000.000 Curie) in order to meet the market demand for irradiated food and healthcare products. Such upgrading seems to be sufficient for the wide demand of medical companies especially those who are going to increase their export capacity of irradiated medical products.
        Speaker: Mr Sherif Abdelgawad (Nathional Center for radaition research and technology, Egypt)
      • 165
        Structural Characterization of γ Irradiated GdBO3/Silica Composite Obtained by Sol Gel Process
        Abstract Samples of GdBO3/Silica composite were prepared by the sol gel process. After elaboration, the samples were irradiated at room temperature with γ-rays using a cobalt (60Co) radioisotope source in the dose range from 1 to 5 kGy. The irradiation effects on the structural properties of the synthesized powders were investigated before and after γ-irradiation using several techniques. DSC analysis reveals that the characteristic temperature of crystallization (Tc) increases as γ dose increases up to 2 kGy and then, decreases with γ-ray dose up to 5 kGy but remains higher than the temperature reached by an un-irradiated sample. XRD and TEM results reveal that γ-ray irradiation reduces the crystallite size from 55 nm to 30 nm. Moreover, it is found from the FTIR study that the absorption bands intensity assigned to structural groups containing BO4 and BO3 units as well as the banding of Si–O–Si bond increases with γ-ray dose up to 5 kGy. From these results, it is concluded that the γ-ray irradiation up to a dose of 5 kGy improves the structural properties of the synthesized material. Keywords: Sol gel, γ irradiation, composite, DSC, DRX, TEM, FTIR.
        Speaker: Ms Samia LADJOUZI (Centre de Recherche Nucléaire de Draria, BP.43 Sebala, Draria, Algiers 16000, Algeria)
      • 166
        The Application of Radiochemical and Isotopic Studies to Inform on the Impact of Acidic Effluent Discharges from the Caldas Uranium Mine into Neighboring Surface Waters
        Located in the Poços de Caldas Plateau, in the southeast of Brazil, the Caldas Uranium Mine is undergoing a decommissioning process. The uranium ore consists of uranium oxides, sulfide and zirconium minerals, fluorite, rare earth phases and molybdenum-bearing minerals. The main environmental problem in the site is the generation of acid mine drainage (AMD) due to the presence of sulfide minerals in the ore and in the host rocks. Acidic effluents flow from a tailings dam, from the open pit and from waste rock piles. The study evaluates the influence of these effluents on the surrounding surface water courses. Twelve sampling stations were established in order to carry out the investigation. Two of them were located inside two effluent retention ponds: the tailings pond that collects the effluents percolating from the major waste rock pile at the site, and the settling pond immediately downstream from the tailings dam. The remaining stations were located downstream and upstream of the mine. Sampling was performed in the rainy and dry seasons in 2010 and 2011. Electrical conductivity and pH were measured in situ; uranium and sulfate concentrations were determined by ICP-MS and by liquid chromatography, respectively. Radiochemical procedures were used to measure the 226Ra, 228Ra and 210Pb activity concentrations. 18O and 2H isotopes were determined by isotope ratio mass spectrometry. 238U was estimated to be 12.3 Bq per mg of uranium mass. Samples from the ponds exhibited high median values of SO42- (1301 mg/L), electric conductivity (1788 µS/cm), 238U (≈109 Bq/L), 226Ra (0.49 Bq/L), 228Ra (0.47 Bq/L), 210Pb (0.70 Bq/L), and low pH (3.6). The effluents from the tailings dam pond presented a more enriched isotopic composition (δ18O = -2.6‰ and δ2H = -18‰) than the other sampling stations, while the opposite was noticed in the pond collecting the waste pile effluent (δ18O = -7.1‰ and δ2H = -44‰). The results also indicated that acidic effluents from the ponds were entering the surrounding downstream watercourses, causing a significant increase in the acidity, electric conductivity, sulfate concentration, and 238U, 226Ra and 228Ra activity concentrations. The variation of δ18O and δ2H values along the watercourses suggests that: waste pile effluent discharges caused a depletion of 2H and 18O in the waters downstream; tailings dam effluents have enriched the stable isotope composition of the waters downstream. These results can be relevant to the stakeholders and to the authorities responsible for the site remediation. The authors will continue to carry out studies on the site, emphasizing the identification of acidic effluent underground leakage points. In future work, tracers, radiotracers and isotopes will be used, contributing to the dissemination of these techniques as important tools for solving environmental problems, with focus on those arising from the mining industry.
        Speaker: Mr Carlos Alberto de Carvalho Filho (National Nuclear Energy Commission CNEN, Brazil)
      • 167
        The Efficiency of Radiation Processing by the Tunisian 60Co Industrial Irradiator after 16 Years of Use
        **Background of the study:** Since its commissioning at 1999, The Tunisian 60-Co irradiator has been mainly used for sterilization of single use medical devices and decontamination of agro-food products. At third half life, the irradiator has a low source activity. This activity leads to a very low dose rate and requires a very long processing time. Therefore, it becomes judicious to study the absorbed dose distribution in the processed product. In this study, evaluation of the irradiator performance was carried out by placing multiple Fricke dosimeters. Dose mapping in the front and back planes of the irradiated product has been carried out and microbiological analysis has been established. **Methodology:** Taking into account its huge virtue in different diseases (cancer, heart-vascular, Cholesterol-lowering effect...) and the short time required for their irradiation, garlic 'Allium sativum L' was considered in this study. Boxes containing garlic, with dimension of (24x20.6x15.5) cm3, were irradiated with 50, 100 and 150 Gy during 7, 18 and 29 min, respectively. The determination of radiation doses measured by Fricke dosimeters are performed using UV-visible spectrophotometer. Thus, yeast, mould and mesophilic bacteria were quantified at different doses. **Results:** *Isodose distribution:* The cartography performed using Fricke dosimeters allowed the determination of the dose uniformity ratio (Dmax/Dmin). Two-sided (front and back) irradiation resulted in a dose uniformity ratio of about 1.5 for garlic and 1.13 for rock wood (used for carthograpy). For the front and back planes, the results showed a symmetrical distribution relatively to the horizontal XY plane. The maps showed that the absorbed dose reached the maximum in the center and decreased slightly keeping the same order of magnitude. Statistical uncertainty of Fricke dosimeters is about 2% and systematic error related to the source activity is below 10%. *Microbiological analysis:* Results obtained for the microbiological analysis of the irradiated and non irradiated garlic showed that irradiated garlic with known absorbed doses harbored bacteria. The high dose irradiated samples (150 Gy) were free of viable bacteria. According to the FAO permissible limits, irradiated garlic never exceeded these permissible counts. Considerable number of yeast and mold (20000 cfu/g) were detected only in non irradiated samples. After 50 Gy irradiation dose, the number of these microorganisms decreased to (61 cfu/g) and continue to be absent for all other doses. The number of total aerobic mesophilic bacteria decreased by the irradiation. This is in agreement with literature for different food commodities. **Conclusion:** Performed studies showed that the irradiation facility at third half life gave an uniform absorbed dose rate distribution. however the processing efficacy of the actual source to preserve fresh food (fruits, vegetables, salads and meat products) in terms of microbiological safety is not reliable regarding the very low absorbed dose rate and the required long time of irradiation. However, preserving low needed irradiation time food (garlic, oignon ...) is possible at actual activity and waiting for the 60-Co source pencils reloading.
        Speaker: Ms Leila Ounalli Mejri (CNSTN, Tunisia)
      • 168
        The Numerical Simulation of Cultural Heritage Radiation Treatment by Monte Carlo Method
        Radiation processing techniques are in wide use in for disinfection and consolidation of archived materials and cultural heritage artefacts. The maximum dose (Dmax), which can be absorbed by product without changing its properties, is known from research phase. So, minimal absorbed dose (Dmin) should be transferred to product to achieve disinfection and this dose shouldn’t be more than maximum dose. The location and magnitude of the dose minimum and maximum is critical to process control, optimized irradiation configurations and it affects both disinfection and product properties. Reliable product dose-maps are necessary for identification of these critical process parameters and may involve time consuming and laborious dosimetry. In some cases determination of the dose-maps is difficult to produce by experiment. Such cases are very often occur during cultural heritage artefacts radiation treatment. In such situations the numerical simulation can be used. After consideration of all possible software toolkits for passage of ionization radiation through the matter GEANT4 was chosen. The CADMesh library was implemented in developed code to input complicated geometry. The radiation sources (plaque and cylindrical) were inputed into the code. Their activities, loading date into operation can be loaded from .csv file. The comparison between measuraments and simulated results were made. The simulated results have shown a good agreement with measured ones.
        Speaker: Mr Volodymyr Morgunov (Ukrainian Engineering and Pedagogical Academy, Kharkiv, Ukraine)
      • 169
        The Study of Gamma Ray Efficiency in Converting of Tehran Municipal Sewage Sludge into a Sanitary Fertilizer
        Abstract The reuse of urban sewage water and sludge in agriculture leads to the transfer of some pollutants into food chain and cause hazardous to public health. Sewage sludge samples are from Shahid-Mahallati wastewater treatment plant in North-East of Tehran-Iran. The heavy metals (As, Mo and Zn analysed by graphite furnace atomic absorption spectrometry (GF-AAS), Hybrid system used for Hg and flame atomic absorption used for Pb, Cd, Cu, Cr and Ni analysis), pathogens (Fecal coliforms, Salmonella, Ascaris ova) and shelf life of irradiated sludge samples according to heterotrophic mesophilic bacteria and their resistance to radiation were investigated in this paper before and after 10, 25 and 50kGy Gamma irradiation from Co60 over a period of 3 months. However, sewage sludge is a rich source of organic matter and nutrients but agricultural utilization of this material is limited by excessive quantities of heavy metals. In this paper the obtained results showed these elements were below the maximum permitted levels of EPA standard and comply with Environmental Pollution Agency standards. The pathogens counts reduced to the extent permitted level after exposure to 10kGy.This dose had the efficiency of reducing 6 log numbers of heterotrophic mesophilic bacteria (as irradiation indicator) but exposure to 50kGy inhibited the regrowth of the bacteria for 80 days of study. Bacterial resistance (D10) was between 0.02-3.09kGy. About 0.074% of studied bacteria had D10 of 2kGy or more. The obtained result showed that 10kGy gamma rays destroyed Salmonella. The number of Fecal coliforms (dominant bacteria in human faeces) in this study were in acceptable limit before irradiation and gamma rays cause a significant reduction in their numbers (ttest, ρ=0.05). Among the helminths of sludge, Ascaris has the most resistant eggs to physical and chemical treatment, in this research the number of fertile Ascaris eggs in the sewage sludge (385/4g), were more than EPA requirements before irradiation but 10kGy gamma rays caused a reduction to acceptable limit (<1 egg/4g) so that there were no fertile eggs in irradiated studied samples. The odor of samples reduced by increasing dose in the way that 50kGy irradiated samples had no odor. According to the obtained data, irradiation by 10kGy converted the studied sludge from class B (studied municipal sewage sludge) to class A biosolids which means that it can be applied to agricultural lands, public contact sites and home gardens. If the sludge is not used immediately after the treatment, the storage time should be regarded.Vector attraction reduction processes must be conducted before use. The capability of mentioned dose of gamma ray in converting of municipal sewage sludge into a sanitary fertilizer depends on the microbial contamination level especially the numbers of viable Ascaris eggs. Keywords: effluent; elements; standard; irradiation; Ascaris; pathogens
        Speaker: Ms Ramsina Betesho Babrud (Atomic Energy Organization of Iran, Iran, Islamic Republic of)
      • 170
        Toroidal Electron Source
        Electron beam sources are important for a very broad field of applications. Sterilization of surfaces, irradiation of polymers for degradation, polymerization, grafting and crosslinking, as well as hardening of lacquers and disinfection of seed are an abstract of applications were electron beams are the state of the art. The penetration depth of accelerated electrons on atmosphere is very limited. The electrons lose their energy on air. To apply an homogeneous dose on 3D shaped products is difficult with existing line emitters or scanners with flat window geometry. State of art is the usage of 2 or 3 line emitters to reach every point of surface on these kind of products. FEP has developed an innovative toroidal shaped electron emitter that emits electrons to the center of the source. (Figure 1) Base of this source is the splitting of electron generation and electron acceleration into two separate process steps. The first step is the generation of the electrons. A plasma generates ions. The ions hit a cold aluminum cathode. The electrons were generated by ion bombardment of a cold cathode. In the second step the electrons are accelerated by an negative potential on the cold cathode in direction to the electron exit window. The first laboratory machines are designed in ring shape. The inner dimension on atmosphere is 180 mm. Even more difficult shapes or are much taller inner dimensions are possible. The research and development of initial plasma and the generation of an homogenous electron beam are part of scientific investigations and will be shown on ICARST. FEP will present adjustment of dimensions, pressure and current for reach stable plasma conditions and dosimetric analysis of treated products like 3D shaped SCF tubs that proofs the improvement in comparison to state of the art processes.
        Speaker: Mr André Weidauer (Fraunhofer Institute for Organic Electronics, Germany)
      • 171
        Treatment of Organic Pollutants Based on PCB in the River Sediment by Electron Beam
        BACKGROUND OF THE STUDY Polychlorinated biphenyls (PCBs) belong among the most persistent and bioaccumulative substances. Long-term production of PCBs in the 20th century has resulted in excessive concentrations of this organic pollutant in the environment with about 200,000 inhabitants in the eastern Slovakia. There were evaluated different techniques of removing PCBs in sediments, but none of them has met three requirements of the local authority district: a) Facility for PCB degradation should be non-static and relatively easy relocatable to other site with PCB contamination. b) Techniques for destruction of PCBs should be : - with negligible secondary waste generation, - with minimum catalysts, - without PCB burning and - easy for automation. c) Adequate investment and operating costs. The goals of the present work are to justify the method for electron beem degradation of PCB (EBDPCB) in sediments, which so far has not yet been used industrially. METHODOLOGY To fulfill the requirements of the local authority district the following method were chosen: - The relocotable electron accelerator for in site EB processing in environment with shielding corresponding to electron accelerator parameters and dimensions is considered. - To establish and determine the clean up and remediation levels for PCB mixture, the toxic equivalency factor was used and then the toxic equivalent was determined. - Adequate investment and operating costs depend on the effectiveness of radiochemical reaction, design and technical parameters of the electron irradiator. RESULTS The method EBDPCB demonstrated that ionizing radiation produced by high-energy electron beams (EB) is remarkably effective in transforming PCBs into less problematic species with minimum catalysts. To increase the efficiency of radiochemmical reaction of the EBDPCB the chemical pretreatment of sediments by using various combinations of isopropanol, K2CO3 and CuSO4, have been tested as well. An increased efficiency of EBDPCB by using electron energy of 3.6 MeV compared to 5 MeV was found. It was shown that in comparison to other types the accelerator based on DC transformer 50/60Hz has advantage in its reliability (availability), high average beam power (productivity), electrical and beam utilization efficiency (cost of exploitation), beam energy for EBDPCB, transportable shielding and price (investment cost). Design of transportable DC transformer type 50/60Hz electron accelerator for EBDPCB has been calculated by the Monte Carlo code MCNPX for electron beam irradiators of 2,5MeV/100kW and 3,5MeV/100kW. CONCLUSIONS Main source of PCB contamination in the environment of eastern Slovakia are sediments in Channel Strážske. Among several methods for environment remedation, the method of radiation degradation of PCBs in sediments by electron beam is the most appropriate for application at Channel Strážske. The method of radiation degradation of PCBs is environmentally friendly and the irradiation facility with electron accelerator can be transported directly to the site with PCB contamination. Treated sediments are recyclable as building gravel sand. The investment and operating costs of proposed technical solution of transportable electron beam irradiator of PCB in sediments are comparable to those ones that did not meet requirements of local authorities at localities contaminated by PCBs.
        Speaker: Mr Marko Fulop (Slovak Medical University, Slovakia)
      • 172
        Tunisian Experience Assessment of Installing a Pilot Cobalt-60 Source for Irradiation
        Radiation processing technology started in Tunisia by the installation of a pilot plant gamma irradiator in 1999 in National Centre for Nuclear Science and Technology (CNSTN) situated at about 20 km in north of the capital Tunis. This facility was established with the support of the International Atomic Energy Agency (IAEA) in the frame of the technical co-operation assistance program and the French Atomic Energy Commission (CEA). The facility is equipped with cobalt-60 source with dry storage and an initial activity of 100KCi in 1999 (10KCi in 2016).The source consists of telescopic cobalt-60 source (08 of C188 pencils-from Nordion), this french design was logged in a concrete shielding room about 1.7m of thickness. This irradiation facilities are designed to be used for the promotional activities of radiation processing applications, in particular for conservation of foodstuff, sterilization of medical devices conservation of art objects and also dedicated to play a great role in enhancing research and development work and providing services to industrials mainly in the fields mentioned above and to gives more competitiveness for products dedicated for export to European Union countries. In this reason Tunisia has implemented a regulation that authorizes radiation sterilization of various pharmaceuticals and foodstuffs. The poster will focus on the activity of radiation technology by Tunisian pilot plant, and show the socio-economic advantages in industry and scientific research during fifteen years of this technology in the country, and discuss the goals achieved.
        Speaker: Mr Mohamed Hedi TRABELSI (CNSTN, Nuclear Science &amp; Technology Center, Tunisia)
      • 173
        Upgrading of Cobalt 60 in Temporary Pool for Dry Storage Irradiation Facility SIBO INRA/Tangier Morocco
        In any irradiation facility, upgrading of $^{60}$Co activity is one of the most important maintenance operations, which should be done periodically to maintain the dose rate in the irradiation process given the decay of $^{60}$Co. In general there are two kinds of irradiator with either wet storage or dry storage of $^{60}$Co in the facility. For wet storage facilities, the $^{60}$Co upgrade receives the cobalt in a supplier provided shipping container and the source is transferred into the pool of the facility to the source rake of the irradiators. For dry storage, cobalt upgrade is done at the supplier facility by shipping the entire cobalt irradiation container, which serves also as transport container, back to the supplier to upgrade the source $^{60}$Co. The Station d’ionisation de Boukhalef (SIBO), is a panoramic irradiator with dry storage of $^{60}$Co in a container which is also used as the transport container in the first loading. We have been faced with a problem of the container transport and we need to find a solution to upgrade the $^{60}$Co. Our proposed solution is to bring cobalt in a supplier container and transferring the new sources to our facility container using a temporary pool fabricated in the facility. The objective of this paper is to show a case study experience. This operation has been considered as a success story by the IAEA and opened this solution method for similar irradiators in other countries which have the same problem. Its execution was a real application of the nuclear security system installed in the facility and during the transport of $^{60}$Co.
        Speaker: Mr Mohammed MOUHIB (INRA Tanger, Morocco)
      • 174
        Using of Radiation Sterilization
        There are 2 general types of radiation used for sterilization, ionizing radiation and non-ionizing radiation. Ionizing radiation is the use of short wavelength, high-intensity radiation to destroy microorganisms. This radiation can come in the form of gamma or X-rays that react with DNA resulting in a damaged cell. Non-ionizing radiation uses longer wavelength and lower energy. As a result, non-ionizing radiation loses the ability to penetrate substances, and can only be used for surfaces sterilizing. For enforcement of the Law on State Supervision of Public Health and the Law on the safe deployment of nuclear and radiological activities in Moldova we developed the scientific technology on ionizing radiation of products of different origin on the base of International Standard ISO 11137 with adaptation at the country needs and specific. This scientific elaboration specifies requirements for validation, process control and routine monitoring in the radiation sterilization and will be implemented under the IAEA coordination. It is stipulated that the following sources of ionizing radiation can be used: gamma radiation from radionuclides 60Co or 137Cs; X-rays generated from machine operated from a nominal energy (maximum photons energy) less than or equal to 5 MeV; electrons produced by machines operated from a nominal energy (maximum energy of electrons) less than or equal to 10 MeV. High energy rays damage the DNA of living organisms and make them unable to grow or reproduce. The elaboration stipulated that the mean total dose of absorbed radiation (kGy) (maximum) for the treatment of dried herbs, spices and vegetable products consist up to10 kGy. Gamma and E-Beam sterilization are planned to be used for medical devices. From experience of other countries is known that both methods are equally effective, but E-Beam is more powerful and hence the exposure time of the device is lesser. During radiation certain parameters of the irradiating unit, according to legal metrology standard, must be controlled and continuously recorded. For installations using radionuclides, the parameters include speed transmission of product or time spent in the radiation zone and indications confirming correct position of source. For accelerator facilities, the parameters include speed transport of product and energy level, current of the electron and the width of barrier installation. Before starting the irradiation for a certain category of food minimum/maximum dose level can be determined by performing dose measurements throughout the product volume. These validation measurements must be carried out in sufficient numbers (eg, 3-5 times) to allow consideration of variations in density or geometry. The dose reference position will be quantitatively correlated with minimum/maximum dose. Reference position is to be situated in a convenient place, where dose variations are reduced. If the fluid unpackaged products are irradiated, minimum and maximum dose cannot be determined. In this case, it is preferable to conduct surveys to determine the extremes dose.
        Speaker: Ms Liuba Coretchi (National Centre of Public Health, Academy of Sciencis of Moldova, Republic of Moldova)
    • P-B: Radiation Technologies for Measurement

      Poster Session on Radiation Technologies for Measurement. Authors will present.

      Conveners: Ms Haifa Ben Abdelouahed (Assistant Professor in CNSTN), TSec Patrick Brisset
      • 175
        Adsorption Behaviour of Chloroauric Acid, a Generic Adsorbing Tracer, for Finding Wetting Behaviour of Fluids in Oil and Gas Industry
        Tracers are widely used to study physical phenomena taking place inside reactors like studying the hydrodynamics of the reactor by residence time distribution or characterising the oil reservoirs for heterogeneity and residual oil saturation. Dual tracer method, which uses one adsorbing tracer and one non adsorbing tracer, is used to characterize the reactors for wetting efficiency of the fluid in gas liquid reactors (trickle bed reactor). Non-adsorbing tracers are well studied in the literature. Chloroauric acid (HAuCl4.3H2O), with Au-198 as gamma emitter, is a tracer that adsorbs on the solid surface, therefore can be used as an adsorbing tracer. It is adsorbed on the surfaces that are easily protonated like silicates (albite, quartz, feldspar), chitosan, polymers and a wide variety of surfaces. This adsorbing behaviour makes chloroauric acid a potential generic adsorbing tracer for oil and gas industry. Glass beads are used in lab scale reactor experiments to form a porous medium. Therefore, adsorption kinetics and dynamics of chloroauric acid on glass surface will impact the characterization of the reactor using the two tracer technique. In the present work, adsorption isotherms and adsorption kinetics of chloroauric acid on glass surface are studied. Non-radioactive form of chloroauric acid is used for this study which can be translated to radioactive gold chemical for better accuracy at industrial scale. UV-visible spectrophotometer, at different wavelengths is used for concentration measurement of non-radioactive chloroauric acid in the chloroauric acid solution. In UV-visible spectrophotometer, UV or visible rays are passed through the sample. The absorbance of the incident rays of a particular wavelength follows Beer Lambart’s law, and is proportional to the concentration of chloroauric acid in the sample. Batch adsorption studies are carried out using glass beads and change in concentration of the solution is measured with time by UV-Vis spectrophotometer. The adsorption and desorption behaviour of chloroauric acid on glass beads is obtained for different tracer concentrations. For chloroauric acid, the pH and chloride ion concentration are found to impact the adsorption - desorption behaviour on the glass surface. The results obtained will be used to characterize the lab scale porous medium for wetting efficiency.
        Speaker: Ms Jyoti Phirani (IIT Delhi, India)
      • 176
        Application of Complementary Beam Techniques to Study Deformation Mechanisms in Heterogeneous Materials for Automotive Industry
        The increasing demand on power and efficiency in automotive industry increases the thermo-mechanical loads and power densities in combustion engines. New materials are required, which combine light weight with sophisticated high temperature strength and creep resistance to meet the requirements. AlSi and AlCu alloy systems are developed for structural parts to improve long-term stability and reduce thermal fatigue damage. In such alloys a composite-like heterogeneous microstructure is formed during casting. The Al$_2$Cu phase in AlCu systems and Si phase in AlSi systems acts as reinforcement of a soft $\alpha$-Al phase. The microstructure morphology (interconnectivity) and the matrix stiffness have significant influence on stress distributions, deformability and crack formation. Therefore, not only composition, but also thermal history (i.e., cooling rates after casting and heat treatments) play an important role for material properties. Two current projects, the “$\mu$-Fe Sensitivitätsanalyse” and “OptiAlloy” funded by the Bayrischen Forschungsstiftung, deal with non-destructive characterization of heterogeneous cast light alloys by complementary applications of high sophisticated beam techniques. Several diffraction and imaging experiments were performed to measure microstress (neutron diffraction), characterize damage initiation and propagation (synchrotron tomography) and to relate them to the microstructure’s morphology (transmission electron microscopy and synchrotron tomography). Photons, electrons and neutrons were used as probe particles according to their interaction with metal and spatial resolution limitations, applicable for the specific problem. Neutron diffraction (Stress Spec, FRM2, Garching, Germany) results show elastic and plastic deformation between the brittle primary phase (AlSi and Al$_2$Cu network) and $\alpha$-Al matrix. Big gauge volume and high penetration depths allow in situ acquisition of strains during high temperature tensile testing. Strain measurements under load and after unloading were performed to distinguish between micro- and macrostress contributions. Synchrotron tomography (parallel beam) with absorption contrast imaging of AlCu alloys and phase contrast imaging of AlSi alloys (low-$Z$ contrast between Al and Si) helps to qualify microcracks within the microstructure in 3D. Two independent characteristics could be identified as mainly responsible for crack sensitivity of AlSi and AlCu alloys: First the morphology of the brittle reinforcing phase (isolated particles versus interconnected network) as crack inducing parameter and second the ductility of the $\alpha$-Al matrix (accommodating stresses by plastic deformation) as crack growth inhibitor.
        Speaker: Mr Robert Koos (FRM2, TU München, Germany)
      • 177
        Application of Radiation Science and Technology in the Republic of Tajikistan
        One of the IAEA National TС Projects having relation to radiation science and technology which was successfully implemented in Tajikistan was TAD/8/002 “Creating Non-Destructive Testing Capability” initiated in 2009. Tajikistan, situated in the one of the most seismic-affected areas in the world having a number of civil and industrial buildings, bridges, tunnels, pipelines, hydropower structures, dams and other objects, has only a very limited knowledge and application of non-destructive testing (NDT). The main objective of the project TAD/8/002 was to establish facilities for non-destructive testing of industrial equipment and components as well as for civil engineering structures in accordance with international standards. Fact-finding expert mission found out the detailed sectors and industries for the possible use of NDT technique in the country, checked on personnel availabilities, and visited the possible laboratory buildings. Several meetings with senior governmental officials were organized, where lectures on NDT for industries, including civil engineering and special purposes, QA management as well as training and certification were presented. They aimed in creating awareness among future possible alliances and end-users of NDT. Necessary equipment to be provided for the laboratory was discussed and agreed. Echograph with C-software; X-Ray generator, both with accessories and software for civil engineering applications; Magneto-Anisotropic indicator of mechanical stresses, model Stress Vision-with software for 2D and 3D presentations; ultrasonic testing calibration block with carrying case and certificate; several laboratory equipment, supplies were purchased. Scientific visits were organized to gain knowledge about the NDT applications in industry and civil engineering structures, the new and advanced developments in the field of NDT including the NDT of civil engineering structures. Two group fellowships have been granted to gain some hands-on experience in the use of above NDT methods in industry, acquire training at Levels 1 and 2 in the four basic NDT methods, to familiarize with standards and procedures for carrying out NDT tests in industry and to take certification examinations at Levels 1 and 2 in the above methods. During the national seminar presentations on infrared thermography stress monitor techniques, rebound hammer, carbonation method, ground penetration radar, ultrasonic techniques, ultrasonic pulse velocity testing and electromagnetic method were presented. In addition other methods, e.g. the oldest and most commonly and widest used method Visual techniques, was also presented. Training materials on NDT for industrial and civil engineering safety in Russian language have been prepared and reviewed. Experts advised on formation of infrastructure for accreditation and certification of NDT in Tajikistan to meet requirements of international standards. NDT capability in the country has been developed. Non-destructive testing laboratory has been created and equipped, personnel properly trained and non-destructive testing procedures established. Procedures for non-destructive control service have been documented and established. Tajikistan has now complete know-how, through which industrial and ecological safety can be improved, risk and extended lifetimes of critical components in civil engineering, transportation, uranium mining and other industries reduced.
        Speaker: Mr Ulmas Mirsaidov (Nuclear and Radiation Safety Agency, Tajikistan)
      • 178
        Axial Computed Tomography Phase-Space Source Model in the PenEasy/PENELOPE Monte Carlo System: Implementation and Validation
        The dosimetric quantities currently adopted by national regulations, or for standardization of dosimetric models adopted by manufacturers of CT equipment are based on a basic metric, introduced about thirty years ago: the Computed Tomography Dose Index (CTDI. This quantity, independent of its definition variations, represents the absorbed dose along the longitudinal axis (central and peripheral) of an acrylic phantom with known and well defined dimensions. Since the introduction of CTDI as appropriate metric for determining the dosimetric characteristics of CT procedures, and its acceptance in the scientific community and between equipment manufacturers, the technology modified significantly the architecture of these systems as well as the clinical procedures for their use. The introduction of CT cone beam systems, with enlargement of the dimensions of the radiation beams to accommodation in a small number of rotations of a larger region of interest, brought significant clinical advantages. However, this expansion of the dimensions of the x-ray beams used in CT scans and the use of helical techniques, started to make improper the use of CTDI. As a consequence, the correct assessment of the CTDI through the measurement of the dose profile along the central and peripheral cylindrical phantom axis has become a work of crucial importance. Several research groups around the world have been developed CT dosimetry tools based on the Monte Carlo method. The ImPACT group provides a CT dosimetry tool based on NRPB SR250 dose distribution data or the use of EGSnrc Monte Carlo system to assess the dose distribution in cylindrical and anthropomorphic phantoms. In this work, it will implement an axial computed tomography phase-space source model in the PenEasy/PENELOPE Monte Carlo system in order to assess the dose spread function along the z-axis and along a peripheral axis of a cylindrical phantom. The x-ray source model has been created for a GE Lightspeed CT family, and it considers the tilted anode, the heel effect and the x-ray spectrum self-attenuation. The phase-space file has been simulated after the CT collimator and the CT setup includes the construction of the shaper filter (bowtie filter). Previous result show the primary dose spread function affected by the tilted anode and by the anode self-attenuation as shown in Figure 1. Finally, the phase-space source model will be used to simulate an axial and helical scan introducing the table displacement (pitch).
        Speaker: Mr Alejandro Heyner Lopez Gonzales (Sao Paulo University, Brazil)
      • 179
        CaSO4:Dy and CaSO4:Ce,Eu Intrinsic Efficiencies Dependence on Ionizing Radiation Type and Quality
        The dependence of the thermoluminescent (TL) dosimeters response with the type and the quality of the radiation is a key issue that is being tackled worldwide by the development of new dosimetric materials associated to this technique. In this context, the aim of the present work is to evaluate the intrinsic efficiency of $CaSO_4:Dy$, considered as the standard material, and $CaSO_4:Ce,Eu$, a newly developed TL material, for different ionizing radiation types and energies. To do so, a batch of fifty five dosimeters of each material was selected according to their non-irradiated TL readout and intrinsic efficiency to the $^{60}Co$ gamma radiation on air and electronic equilibrium conditions and then divided into eleven sets of five dosimeters, one of the sets being kept as the control set to evaluate the non-irradiated TL signal while the ten remaining sets were irradiated, again in air and electronic equilibrium conditions, with doses ranging from 0.1 mGy to 10 Gy in secondary standards $^{60}Co$ and $^{137}Cs$ gamma radiation sources, RQR, RQA and RQT ISO/IEC 61267 series and N ISO 4037 series X-ray beams, always including the reference quality for the radiation beam series, and tertiary standard collimated electron beams with effective energies from 4 MeV to 20 MeV. A Thermo (Harshaw) 3500 thermoluminescent reader was used to evaluate TL readouts 24 h after the irradiations and the obtained glow curves were exported in the ASC format through WinREMS TL reader controller associated software. Individual peak intensity, integrated response, peak to peak intensity ratio, calibration curves and intrinsic efficiency, provided that all dosimeters are 0.8 mm thick pellets of 6.0 mm of diameter containing 16.67 mg of TL material, were calculated with the aid of SciLab 5.5.2 software, also used to graphically explore the behavior of $CaSO_4:Dy$ and $CaSO_4:Ce,Eu$ intrinsic efficiencies with the radiation type or the radiation quality. As expected from literature, $CaSO_4:Dy$ intrinsic efficiency presented a dependence of up to 30% with radiation type or quality while $CaSO_4:Ce,Eu$ intrinsic efficiency varied in 200% with radiation quality. Despite this huge dependence, $CaSO_4:Ce,Eu$ peak I to peak II intensity ratio remains stable with the radiation type and varies in 5% from one radiation type to another, so that this newly developed TL material can be used as a dosimeter capable of determining, in non-mixed radiation fields and after an adequate and rigorous calibration, both radiation type and quality besides the dose.
        Speaker: Ms Maira Goes Nunes (National Nuclear Energy Commission, Nuclear and Energy Research Institute, Brazil)
      • 180
        Comparison of Image Reconstructions for Gamma Transmission Computed Tomography System by Using MATLAB and i-Gorbit Software
        Abstract With wide industrial application, computerized tomography CT is rapidly developing technique that is especially useful for imaging and measuring multi-component and multiphase processes. The most important contribution of CT is to greatly improve abilities to distinguish regions with different gamma ray transmittance and to separate over-lying structures. The CT system of single source and detector gamma transmission tomography GORBIT, designed by CANTI, Vietnam, was used to analyze the different density materials. Hardware of the GORBIT CT system consists of two servo motors, data logger, computer, a radiation source and a radiation detector. The measurements in GORBIT system were carried out at the CT Laboratory in Department of Atomic Energy, Yangon. This tomography system operates with a gamma ray source of 60Co1.85 GBq (50 mCi of intensity) and a NaI(Tl) scintillation detector. Measured gamma transmitted data were used to reconstruct the cross-sectional images of research samples. These images were reconstructed from the measured transmitted data in different image reconstructions algorithms. Analytical methods of back projection (BP), the filtered back projection method (FBP) and iterative algorithms of algebraic reconstruction method (ART) and estimation maximizations (EM) methods were used in i-GORBIT image reconstruction software. Another image reconstruction program GCTS was created by using MATLAB package. In this image reconstruction, different algorithms of back projection (BP) and filtered back projection (FBP) were used. In FBP method, different filters of Ram-lack filter, Sheep-Logan, Hamming, Hann and Cosine filter can be chosen and different interpolation methods can be applied to improve the quality of images. The results of different image reconstructions programs were compared and analyzed for the sample materials. In this research work we will present some results obtained by using tomographic techniques to analyze various samples to check the distribution of various density materials. These samples are made by using different properties of materials with high and low density materials of lead, ion, six holes brick, polymer slab contained in a polymer pipe vessel. These samples are also used to verify the outcome from the CT analysis with different image reconstructions programs i-GORBIT and MATLAB. Keywords: Industrial Gamma ray computed tomography, transmission measurement, image reconstruction algorithms, MATLAB, linear attenuation coefficients
        Speaker: Ms Khaing Nyunt MYAING (Department of Atomic Energy, Myanmar)
      • 181
        Development of a New Ambient Dosimetry Monitor Associated with a Software Interface for in situ Environmental Monitoring at the Nuclear Studies Centre of Maâmora- Morocco
        In this paper, we propose the development of a new data logger system for monitoring the radiation environment in situ of Morocco nuclear studies centre. This device is used to measure continuously the $\gamma$-dose rate for plotting and monitoring ambient radioactivity, and equipped with an alert system to alert the operator in cases which exceed the dose rate threshold limits. It mainly consists of a high-pressure ionization chamber whose response is directly proportional to the ionization intensity created by the radiation. This paper details the development stages of a radiation datalogger which is associated to a specific monitoring interface for remote measurement of ambient $\gamma$-radiation. It starts first with studying the relationship between the dose rate and the output ionization current of the HPIC chamber, followed secondly by the development of digital processing unit for measuring and data recording, and thirdly finishes with the development of a data transfer module, using an XBee protocol of RF transmission, to the host computer. In addition, this paper presents also new software which is associated to the datalogger device, used as data acquisition interface, and was designed and characterized by specific parameters for real time remote monitoring of $\gamma$ ambient dosimetry. In fact, environmental radiation dosimetry has been performed with a high-pressure ionization chamber which supplies a current directly proportional to the amount of the incident particles energy. The output ionization current is of the order of $10^{-14}$ A/Gy/h per cubic decimeter, equivalent to energy absorption of $10~\mu$J/h and per gramme of the chamber material. This current is DC coupled first to a preamplifier where it passes through a high ohmic resistance of $10^{10}~\Omega$ to establish a difference of potential, and followed by a negative feedback linear amplifier circuit. The output of this amplifier is then connected to the electronic module for digital data treatment and transmission to the acquisition software installed into PC.
        Speaker: Mr Rachad ALAMI (National Center of Energy Sciences and Nuclear Techniques (CNESTEN), Morocco)
      • 182
        Evaluation of TL and OSL Response of CaF2:Tm for Electron Beams Dosimetry in Radiation Processing
        An increasing number of pytosanitary irradiations using electron beams has encouraged the development of surface dosimetry systems to cope with both low and intermediate absorbed doses and dose rates. Besides the well-stablished reference and routine dosimeters, ranging from alanine to radiochromic films, there is an interest in dosimeters based on thermoluminescence (TL) and optically stimulated luminescence (OSL) effects. In this context, the aim of this paper is to study the TL and infrared stimulated luminescence (IRSL) response of the calcium fluoride dosimeter doped with thulium (CaF2:Tm) produced via combustion synthesis (CS) by the Nuclear Energy Department of Federal University of Pernambuco, Brazil. The pellets with 6mm in diameter and 1mm thickness were obtained by pressing the powder using 10% PTFE as binder material. The individual TL and OSL sensitivities of the dosimeters of the batch were previously evaluated and a group of 50 pellets with a standard deviation of 6.8% was selected to be used in this study. After that, the performance of these dosimeters to electron beams with 1.5MeV from a DC 1500/25/4 – JOB 188 Accelerator at the Radiation Technology Center at IPEN-CNEN/SP was investigated. For each dose, 4 pellets of CaF2:Tm, together with 4 pellets of alanine were irradiated with doses from 0.5kGy up to 10kGy. The TL and OSL readings were carried out after a pre-heating at 100ºC during 15min using a Riso TL/OSL reader, model DA-20. The TL measurements were taken with a heating rate of 2°C/s, in the range from 50°C to 350ºC. The OSL readings were carried out with infrared stimulation with optical power attenuated to 20% during 240s. These readings were thermally assisted at 150ºC. Residual thermoluminescent glow curves for IRSL were recorded after stimulation times. The reproducibility and stability of the TL and IRSL responses were also evaluated, as well as the dependence with different dose rates. The results showed that the main TL peak of the glow is in the region of 200°C and it was observed that the IRSL curve of the dosimeters presents a fast and a slow decaying IRSL signals. The TL and OSL dose response curves were fitted by a second order polynomial function with correlation coefficients of 0.97 and 0.99, respectively. The results indicated the possibility of the application of CaF2:Tm for electron beam dosimetry in radiation processing.
        Speaker: Ms Carmen Cecilia Bueno (Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP, Brazil)
      • 183
        Examination the Performace of the Trayed Ethylen Production Column Using Gamma Ray Scan Techique
        Gamma ray scanning technique has been demonstrated to investigate the performance of trayed column in a petrochemical company. The trayed column is a caustic/water tower of having diameter of 4.2 m and 40 m height. The multigrid scanning was performed using 70 mCi of Co-60 gamma source and scitillation detector. Ten trays, starting flrom tray # 13 at elevation of 35.050 mm to tray # 4 at elevation of 26.950 mm above groun level. Scan data show that all trays were in their potisitons. Tray # 4 to tray # 10 were functioned properly dan carried approximately the same amount of liquid. Light liquid flooding on tray # 11 and heavy flooding on tray # 12 were identified. Partial flooding was identified on the tray # 13. At the time of shutdown, the scanned data was verified and it was found that the liquid flooding on the tray # 12 was caused by presence of a bucket on that tray, covered with solidified mud. Keywords: gamma ray scanning, trayed column, likuid flooding, 60Co,
        Speaker: Mr Sugiharto Sugiharto (Center for Isotopes and Radiation Application, Indonesia)
      • 184
        Ion Irradiation Effects on the Optical Properties of Quantum Dots for Nano-Dosimetric Systems
        A. Ficorella1,2, L. Pancheri1,2, A. Quaranta1,2, G. F. Dalla Betta1,2, M. Dalla Palma1 1University of Trento, Department of Industrial Engineering, via Sommarive 9, I-38123 Povo, Trento, Italy. 2INFN, TIFPA, via Sommarive 14, I-38123 Povo, Trento, Italy. Nowadays it is generally accepted that the radiation damage on cells induced by hadron beams is related to the track structure, i.e. to the spatial distribution of stochastic interactions occurring with nanometric volumes. Luminescent quantum dots (QD) seem to be promising candidates for the realization of portable systems for the evaluation of the nano-dose. Ionization produced in QDs by scattered electrons give rise to quenching or luminescent centers affecting the optical properties of nanocrystals. So, changes of both luminescence features and excited states lifetimes after irradiation can be used for evaluation the damage released by ions in nanometric volumes. In this work, we studied the optical properties of luminescent QDs irradiated with 2.0 MeV H+ proton beams at different fluences. Semiconductor QDs are dispersed into polysiloxane films at different concentrations on silicon substrates and their luminescence properties are analysed before and after the irradiation. During irradiation the light yield is monitored by means of ion beam induced luminescence (IBIL) measurement. The luminescence bands are measured with a spectrofluorimeter Jasco FP6300 by exciting the samples at different wavelength in order to identify possible distribution of emitting centers or size dependent optical properties. Lifetime measurements are performed with different pulsed lasers, at 355, 405 and 450nm. The lifetime changes after irradiation are correlated with the formation of quenching centers in QDs. The results are a proof of concept for the realization of a nanodosimeter based on QD luminescence properties.
        Speaker: Mr Alberto Quaranta (University of Trento - Department of Industrial Engineering & TIFPA, Italy)
      • 185
        Neutron Activation Installments for Control of Flour Spar Enriching Factory in Mongolia
        Mongolia is rich in fluorite resources and enriched fluorine is one of items of mineral export of Mongolia. Sorting fluorite ore on the input of the enriching factory is an important measure to keep the enrichment process running smoothly. A determination of fluorine content in the enriching pulp allows fast control of the enriching process. Rapid neutron activation technique for fluorine content determination in the pulp takes $15$ min against the traditional chemical analysis (one day). In this paper, devices based on neutron activation technique for fluorine determination in fluorite ore and enriching pulp in the factory are described. The first device (Flourite-1) was developed as a stationary instrument for fluorine content determination in the fluorite ore at mine. The second device (Fluorite-2) was developed to determine fluorine content in ore on the lorry to sort ores in the factory input. Sorting ore on arrival by its content is important for enriching process control, as ore to the factory arrives from different mines. The third device (Fluorite 1M) was developed as stationary (like Fluorite-1) to determine fluorine content in the enriching pulp to control a enriching process. All devices use fast neutron activation analysis. Neutron sources $^{238}$Pu-Be, $^{241}$Am-Be, $^{252}$Cf were used for nuclear reaction $^{19}$F$(n,\alpha)$$^{16}$N with measurements based on detecting the resulting $6.13$ MeV $\gamma$-ray. Coincident $\gamma$-ray of $5.5$ MeV and $5.11$ Mev are detected which are released from the samples during the measurement. The $^{16}$N half-life is $7.35$ s and the $\gamma$-ray intensity is proportional to the fluorine content (CaF$_2$) in the ore or enriching pulp. Fluorine content is calculated compared with standard samples. Regular $150\times100$ mm NaI(Tl) $\gamma$-ray detectors collect the data. Fluorite-1 is single channel spectrometry system, where samples and standards are measured in turn using one counter system. Fluorite-2 is a microprocessor controlled system. Neutron activation of the ore and $\gamma$-ray detection is made by a pneumatic system moving source and detector to the lorry. Spectrometry amplifier stabilizer was developed as the detector of device placed outside and amplitude of detector signal was changing depending on temperature change (temperature range is $-40^\circ$C to $+40^\circ$C). Standard $^{137}$Cs sources were used for stabilization, calibration and control of the measuring system. Fluorite-1M has two counters to count pulses from standard and the samples in each counter, which allow to reduce time of measurement. Fluorite 1M had absolute error less than 1% and it was much needed for Bor-Undur, Fluorite Enriching Factory, Mongolia during the economic crisis years 1990–2000, when there were shortage of chemical components for chemical analysis of the factory. This kind of device can be used for control of fluorine enriching factory for industry process control. Especially this kind of device is needed for purchasing of fluorite ore from individual customers or export in Mongolia.
        Speaker: Mr Lodoysamba Sereeter (German-Mongolian Institute for Resources and Technology, Mongolia)
      • 186
        Neutron Radiography Studies for Detection of Hydrogen Distribution in Nuclear Fuel Claddings at Research Centre Řež
        Zirconium (Zr) based nuclear fuel claddings act as, barrier against loss of fuel particles into the coolant water during plant operation, handling and dry storage of the spent fuel rods. Claddings absorb hydrogen produced during reactor operation due to water side corrosion. Increase in the Hydrogen (H) concentration limit can lead to hydride precipitation, resulting in the reduction of cladding strength and/or mechanical failure by a process called Delayed Hydride Cracking (DHC). Mechanism DHC damage is related and dependent on the hydrogen concentration, temperature and stress level in the cladding. Therefore distribution and quantification of hydrogen in Zr based fuel claddings is an object of intensive research. The high sensitivity of neutrons for hydrogen and as a non-destructive method, makes neutron radiography a useful technique for detection metal hydrides and their distribution/location in cladding. Un-irradiated Zr based fuel clads (Zr-1%Nb) have been investigated at neutron radiography facility of LVR-15 research reactor in Rez, Czech Republic. The samples were investigated in horizontal channel that offers an intense thermal neutron beam with a diameter of 10 cm. The facility is equipped with newest Timepix based detectors, with thin 6LiF converters for neutron detection capable of delivering high resolution. 2D radiography results have been obtained from 3 fuel cladding sections that differ in their hydrogen content. Qualitative information on hydrogen concentration locations in fuel cladding were identified. The H-distribution was revealed by image processing based on intensity histograms. Based on the neutron radiography results, quantitative evaluation of hydrides distribution was performed by classical metallographic procedure and electron microscopy. Qualitative and quantitative inspection of hydrogen distribution in fuel claddings is reported in this paper.
        Speaker: Mr Hygreeva Kiran Namburi (Research Centre Rez, Czech Republic)
      • 187
        Radiation Dosimetry of Laboratory Practices based on Radiotracers Techniques
        Radiotracers techniques have become an important tool for the diagnosing industrial reactors and optimizing processes. Recently many radiotracer laboratories have been established aimed at on job training and R&D in the African region with the aid of IAEA TC projects. This paper shows our efforts in radiation dosimetry, safety, and emergency procedures complying with the regulations of the Sudanese nuclear and radiological regulatory authority (SNRRA) for the licensing and commissioning of a radiotracer laboratory. Experiments using Tc-99m 15GBq radionuclide generator have been conducted in the lab in the presence of expert radiation inspectors from SNRRA. Then radiation monitoring for the workplace has been done as well as for the surrounding environment. Consequently personal dosimetry has been recorded for the radiation workers involved in those experiments. The paper shows the results of measurements and discusses how optimizing radiation dosimetry, safety has been achieved during the work.
        Speaker: Mr Mamoun Idris Ali SAGIROUN (Sudan Atomic Energy Commission, Sudan)
      • 188
        Radiation Shielding Design Assessment of Nucleonic Gauges
        **BACKGROUND** In recent years, several standards have been issued by different international committees in order to specify requirements for the design of nucleonic gauges taking into account issues related to radiological protection. For this purpose, the agreement with these standards should be included as part of the equipment specification to the licensing process, however, most nucleonic gauges in Brazil were installed in the period prior to the issuance of these international standards. This study aims to evaluate the shielding performance of different models of nucleonic gauges, installed in Brazilian industrial facilities, during operational and maintenance procedures, taking into account the international standards (ISO/IEC) concerning to the constructional requirements and classification of nucleonic gauges. **METHODOLOGY** In Brazil there are several hundred of these equipments installed in at least 500 industrial facilities. Using the information available into Brazilian nuclear regulatory body database, it was selected reference industrial facilities that use a wide range of nucleonic gauges with different radioactive sources and manufacturers. In order to assess the shielding performance of nucleonic gauges, the dose equivalent rate was determined in-loco during operational procedures. The protocol for the measurements took into account the requirements and procedures proposed by IEC 62598:2011. The maximum dose equivalent rate was determined at different distances from the nearest accessible surface using ionization chambers with different detection volumes. In view of the specific operational conditions found at reference facilities (not covering all operational situations), the measurements obtained have been used for validation of a Monte Carlo code based on GEANT4 to allow extrapolations for other operational conditions. **RESULTS** Initially, it was evaluated different designs of nucleonic gauges developed in Brazil. The maximum dose equivalent rate was determined at the reference facility and the designs were modeled and simulated using GEANT4 Monte Carlo program, as shown in figure 1 for a specific model. With the dose equivalent rate results to each model, the nucleonic gauges should be classified into the seven dose rates classes, as specified in the international standards. It should be noted that, according IEC standard, the equipments in class one are considered not in compliance with constructional requirements, and it should be removed from work. The study is still in progress, in order to include other nucleonic gauge models in use in Brazil. **CONCLUSION** Nucleonic gauges can be subject to extreme environmental conditions such as high temperatures, salinity, humidity and explosive atmospheres. Aspects of the design and manufacture of these devices should be treated as an important feature for a proper approach to radiological protection. The efficacy of a regulatory system to control radioactive sources is determined by its appropriated implementation considering the resources available, normally limited. Therefore an optimization of resources is needed. The results obtained in this study can enable the establishment of a safety indicator tool to industrial facilities, taking into account different designs of nucleonic gauges, so, this additional parameter can be used to determine and to optimize the frequency of regulatory inspections.
        Speaker: Ms Joana D'Arc Ramos Lopes Gomes (Brazilian Nuclear Energy Commission, Brazil)
      • 189
        Resident Time Determination of IPAG60 in Order to Increase Efficiency of Drinking Water Treatment Plant for Peatland Area
        IGNASIUS D.A. SUTAPA Asia Pacific Centre for Ecohydrology (APCE) - UNESCO Jl. Raya Bogor Km 46 – Cibinong - Bogor 16143 INDONESIA Email : ignasdas@yahoo.co.id/ignasdas@gmail.com The majority of areas in Riau Province and Midle Kalimantan Province have the land with peat surface water. The characteristics of the peat water are: low pH levels (2-4) that is highly acidic; high levels of organic; high levels of iron and manganese; yellow or dark brown. This kind of surface water is basically not suitable as raw water for drinking water. Compared with other surface water that is fresh water, the water from the turf needs to be processed specifically by adding stages in the process. In order to improve the efficiency of water treatment plant, it would require a study to determine the resident time of IPAG60. Li tracer will be used in this study for the reason of availability, accuracy and easyness. Peat water treatment technology that has been established in previous studies allows the peat areas have peat water treatment facility for drinking water supply. The implementation and testing of the water treatment facility is limited in the area of Katingan Distric, Central Kalimantan province and Bengkalis Distric – Riau Province, meanwhile, a lot of territory in some areas in Indonesia, especially Sumatra and Kalimantan, which has a clean water source issues. Implementation of this technology in the wider area is necessary to support the increase in water services in the region. The quality of peat water and clean water (treated by IPAG) indicate that the IPAG can improve peat water quality (class C) into clean water quality (class A). Key words : resident time, peat water, IPAG60, water quality, efficiency
        Speaker: Mr Ignasius SUTAPA (Asia Pacific Centre for Ecohydrology (APCE) - UNESCO, Paris, France)
      • 190
        Results of Radiation Protection in Practices with Sources of Ionizing Radiation in the Petroleum Refining Industry
        Sources of ionizing radiation have wide application in medicine, industry, research, agriculture and education. These sources must be managed in conditions of safety and security. If used incorrectly or in unsafe conditions, radioactive sources can cause death, serious injuries and economic losses, as demonstrated by the experience in many areas of the world. In the oil industry, specifically the oil refining industry has wide application of ionizing radiation sources in the following fields: 1. Study and control of catalysis. 2. Measure and control fluid flow. 3. Determination of residence times of liquids in closed systems. 4. Location of interfaces or separation zones of petroleum products circulating in the same pipe. 5. Analytical determination of components such as sulfur. 6. Studies on corrosion protection. 7. Fire detection and gas. 8. other In Cuba three oil refineries are installed in different parts of the country the case in this work is the Cienfuegos refinery located in the south-central Cuba, specifically in the northern margin lobe of the Bay of Cienfuegos region. Its purpose is oil refining and product manufacturing, purchase, storage, processing, distribution and marketing of oil and petroleum products within the Cuban territory and abroad. In the Cienfuegos oil refinery various types of sources of ionizing radiation, linked to the following practices are used: 1. Location of interfaces or separation zones fixed level nuclear gauges are used with Cesium sources 137, Cs-137, for a total of eight sealed sources, which are used in desalination. 2. Fire detection and gas, ionic smoke detectors used with sources of americium-241, Am-241, for a total of 450 sources, 3. Detection of analytical components, two sulfur analyzers with X-ray tubes. The above practices have spent more than 8 years in use with very good results. Radiation protection in the exercise of these was based on the demands and requirements established by law and national legislation in line with the basic rules and guidelines proposed by the IAEA internationally. At the time elapsed they have not reported overdose of occupationally exposed workers, or specialists and workers related to the exercise of practices, nor have reported incidents or radiological events. The results are based on training and training of occupationally exposed workers and workers linked to practices in the documentation of each and study and exercise plan radiological emergency linked to other key plans like plan emergency in case of fire and disaster reduction plan. Training continuity by simple elements such as lectures, conferences, videos, business web, and internal magazines to the entity raise awareness and training of workers in confronting possible events and the responsible use of the potential of the exercise of these practices.
        Speaker: Ms Maricela Rodríguez Alayón (Cuvenpetrol s.a., Cuba)
      • 191
        Simulation Studies on the Image Quality of Industrial Film Radiography
        This communication highlights investigations aimed to attain a comprehension about the Radiographic Non-Destructive Testing (RT) of water-filled pipes; with the objective of improving the radiographic quality. A radiographic Testing computational toolkit was used to simulate film radiography of a water-filled pipe having an outside diameter of 219 mm (8 inches), using Ir-192. The results showed that water significantly increases the Scattered Direct Ratio (SDR) on the film, which results in a poor sensitivity. An approach to decrease the SDR was examined; and the results indicated prospects to improve the radiographic quality. Simulation results will be used to set up experiments; to further study the proposed approach.
        Speaker: Mr Mohammed Siddig Mohammed (Department of Nuclear Engineering, King Abdulaziz University, Department of Nuclear Engineering, King Abdulaziz University, Saudi Arabia)
      • 192
        Study of Sediments in a Sub-Basin of the Panama Canal Using Nuclear Techniques
        In early December 2010 a storm that occurred was named “La Purisima " the largest storm in the history of the Canal watershed. According to the Panama Canal Authority (ACP, acronym in Spanish for Autoridad del Canal de Panamá) Yearbook of suspended sediments for 2010, the storm was associated with the interaction of a low pressure center, the remnants of a stationary front and the intertropical convergence zone in the north-eastern part of the basin of the Panama Canal. The storm produced a record 760 mm of rain in 24 hours. There were more than 500 landslides in the watershed above the dam Alajuela. These landslides resulted in a large amount of suspended sediment lead to this dam, where potable water facilities for the City of Panama are located. This led to a turbidity of water from the dam to 700 Nephelometric Turbidity Units (NTU), causing the collapse of the water treatment plant, leaving a large part of Panama City without drinking water for nearly two months. On the other hand, waste waters contribute to serious pollution problems not just in Panama Canal basin but also at the Panama Bay influencing marine and coastal environment, and there is not an effective monitoring program for contaminants in treatment plants wastewaters effluent and coastal marine areas. In addition to this, the sediments are vectors of contaminants such as heavy metals, etc. The Panama Canal Authority (ACP) must operate efficiently and scientifically sediments from dredging works (suspension, deposition at some site, etc.) because it is basically great interest to maintain and better water quality both in Panama Canal river basin as in the urban area. Therefore, a characterization of the dynamics of sediment transport phenomenon using the radiotracer and chemical tracers would offer a rigorous and efficient methodology for a national program of measurements or monitoring plan of transport and behavior of pollutants into resources water of Panama, including the study of sediments at the biggest Panamanian WWTP. For sediment transport monitoring, radioactive and chemical tracer technology was selected because it is a very reliable, accurate and non-intrusive procedure. Its use required low amounts of radioactive substance. Also, tracers have high resistance to physical factors, such as temperature and pressure, which make them ideal for this type of studies. One of the goals of this study is to contribute in reducing contamination level to international water quality standards, through an efficient sediment transport monitoring program in a Panama Canal basin and check out the contribution of wastewaters treated at WWTP to marine and coastal environments. To achieve this goal, it is necessary to study and compare both methods, non-nuclear and nuclear techniques, using nucleonic gauge, and comprehend all the processes involved in sediment transport along the Panama Canal basin, including the contribution of treated waste waters, during dry and rainy seasons, considering also physic-chemical factors.
        Speaker: Ms Kathia Broce (Universidad Tecnológica de Panamá, Panama)
      • 193
        Synthesis Method of Multimodal Radiotracers for Industrial Processes and Environmental Research
        **Background** Radiotracer methodology has been described extensively in the literature. Though radioisotopes have been applied to the solution of problems in industry for over 60 years, research and development of the technology continues unabated. Their role in investigating industrial problems has been expanding both in routine testing and process research and development. Extensive experience has been gathered all over the world in application of radiotracers in industry. There are many reasons for the continuing interest. One of the most important is industry driven. Multimodal radiotracers with other specific properties (fluorescent or magnetic properties) are attractive field of investigation. It can be used for mass transport experiments into copper metallurgy industry. Such studies require the development of representative tracers in order to follow raw material particles along their routes of transfer. Second great area of interesting is using radiotracers into environmental research field. Radiotracers are used primarily to reveal the transport processes, dispersion and settling of industrial waste in the natural environment. With their limited environmental impact, radiotracers have the potential to be used in a variety of new applications to create a wider awareness of the environment and the challenges it faces. **Methodology** The objective of the work is developing of novel multimodal radiotracers with optical and/or magnetic properties. Basing on our experience, silica crystals SIO2 have been selected as a matrix for radiotracer. This kind of material is easy to obtain by advanced chemical-ceramic method called sol-gel process. Gels in the forms of powders were prepared by hydrolysis and subsequent polycondensation of tetraethoxide/Me nitrate solutions containing ascorbic acid (ASC) as a catalyst, instead of the HCl or NH4OH that are routinely used for catalysis in this kind synthesis. During the formation of the silica gel various metals can be immobilized into crystal structure of silica particles. The material is sintered and milled. Finally the metal incorporated into the structure is activated into neutron flux and radiotracer is ready to use. **Results** Following our method we obtained several samples of various radiotracers. As a radiotracer 192Ir was selected. Iridium is easy to activate into neutron flux and the half-life time of 192Ir seems to be acceptable. For obtaining fluorescence or magnetic properties we can use a various additives. The properties of the tracer was investigated on fluorimeter, magnetic resonance and gamma spectroscopy. **Conclusion** The advanced radiotracers with combined properties are very unique and can be used for wide range of applications. Proposed materials can be used for wide range of industrial and environmental applications. Modified sol-gel process is suitable and efficient method for synthesis of this kind of radiotracers. **Acknowledgments** This work is part of the projects: “Nano-radiotracers with magnetic and fluorescence properties for labeling of micro-particles of sand and clay.” co-financed by Polish Ministry of Science and Higher Education and IAEA.
        Speaker: Mr Tomasz Smolinski (Institute of Nuclear Chemistry and Technology, Poland)
      • 194
        Terrestrial Background Radiation in Norochcholai in the North Western Coast of Sri Lanka
        Radiation from natural sources can be broadly classified in to two, namely, terrestrial radiation and extra-terrestrial radiation. Terrestrial radiation originates from natural radio-nuclides present in rocks, soils, atmosphere, and the hydrosphere. Extra terrestrial radiation or cosmic radiation having very high energy originates from the sun. In most of the cases radiation exposure from natural sources is not harmful to humans but health protection measures need to be considered. The objective of this study was to assess background radiation in soil, water and air in a Sri Lankan population (in Norochcholai) living in close proximity to the nuclear power plant in Kudankulam, India for future monitoring of potential radiation leaks. This study assessed radiation levels in soil, water and air in the Norochcholai area situated in the north western coast of Sri Lanka. Background radiation levels at 1m height were recorded using a survey meter (automess dose rate meter 6150AD). Superficial soil samples from 23 locations and water samples from 15 locations were analysed by Gamma spectrometry. The activity concentration of natural radionuclides in the soil and water samples were measured by using a HPGe detector having a relative efficiency of 32.6 % with G1 geometry (diameter of 8.4cm and a height of 2.9cm ) at ISO 17025:2005 accredited Gamma spectrometry laboratory of the Sri Lanka Atomic Energy Board. The radioactivity concentrations of 232Th, 40K, 226Ra and 210Pb radionuclides in the soil and water samples were measured. The median radioactivity concentrations (range) of 232Th, 40K, 226Ra and 210Pb were 56.0 Bqkg-1(16-256 Bqkg-1), 96 Bqkg-1 (62.5-294 Bqkg-1) 24Bqkg-1 (0.7-83Bqkg-1) and 27Bqkg-1 (13-81Bqkg-1) respectively. Mean background radiation level was 0.1μSv h-1. The gamma ray absorbed dose rates due to 32Th, 40K and 226Ra 2 in soil samples varied between 13.9nGyh-1 and 202.8 nGyh-1 with an average of 61.0 nGy h-1 which is higher than the global average of 57 nGyh-1. The mean effective dose was 74.9 μSv.y−1. Radium equivalent activity ranged from 30.3-458.4 Bqkg-1 and the mean was 136.5 Bqkg-1. In one soil sample the radium equivalent activity was above 370 which is the cutoff value set by the NEA group of experts as safe to be used in building materials. The absorbed dose rate did not correlate with the background radiation levels detected (p= 0.727). The annual effective dose due to terrestrial radiation (0.074 mSv.y−1) was less than the worldwide average of annual effective dose from natural background radiation due to terrestrial gamma radiation (0.46 mSv.y−1). No radioactivity was detected in any of the water samples. The soil from this study area is safe for use in construction of human dwellings. No radioactivity was detected in water sample.
        Speaker: Ms Thiwanka Weerakkody Appuhamillage (Sri Lanka Atomic Energy Board, Sri Lanka)
      • 195
        The Concentrations of Major and Trace Elements in Powdered Milk using XRF and NAA, and Comparison to Other Techniques
        Milk and dairy products are considering one of the unique sources for children and even adult’s nutrition. They are also the source of some vitamins and many minerals. Furthermore, they are most versatile for natural food in terms of configuration and determine the necessary components for a healthy life. Milk contains more than twenty elements of different trace, most of them are necessary and very important, such as copper, zinc, manganese and iron. These elements are the factors involved in many enzymes and play an important role in many physiological functions. The lack of these elements cause disturbances and pathological conditions. In addition, it was noted that the increase in the concentrations of heavy elements such as chromium, cadmium, lead and mercurywill cause damage to the human origins such as kidney’s disorder, liver and anemia. Furthermore, these inspections on the heavy elements are of particular concern as milk is largely consumed by infants and children . In this study eight different milk samples were selected from the Iraqi markets to measure the concentrations of major and trace elements. The samples that were selected are most widely usedby the Iraqi consumers. These brands are Ankor, Nan, Similac, Nedo, Gold, Novalac, Kikoz/1 and Kikoz/2. Different analyzing techniques were used to cover most of the elements that exist in the samples. Techniques such as X-Ray fluorescence (XRF), Neutron activation analysis (NAA) technique, chemical analyses Kjeldahl technique and atomic absorption spectroscopy (AAS) technique were employed to determine these elements and their concentrations. The obtained results were compared with authorized limit by FAO/WHO standards. Necessary to evaluate the contents of ‘‘essential’’ and ‘‘toxic’’ heavy metals on a greater number of milk samples from various supplies and confirm the absence of possible toxicological risks.
        Speaker: Mr Jamal Kadhim Jaber Al-Saedi (Ministry of Science and Technology, Iraq)
      • 196
        The Study of Industrial Process with Radioactive Tracer RTD Method Enhanced System Analysis
        Radioactive tracers RTD method is one of the most common nuclear techniques used for troubleshooting and optimizing industrial processes involved in different industries such as petroleum, petrochemicals, chemicals, ore mining, cement and waste water treatment . The technique is easily implemented with simple concept of instantaneous impulse response so called Dirac. On the last decades, significant development has been done with the advent of new equipments, electronics, portable computers and software. However the style and quality of the results itself has not considerably changed since its beginning. Correct data gathering and system analysis, interpretation and reporting are abilities often difficult to go with or require a long time of training and experience. This paper describes our attempts on developing a new approach on the radiotracer RTD technique using Tc-99m radiotracer to measure the RTD of closed circuit water flow rig tank. The data has gathered and treated using both Dirac and non-instantaneous impulse. The paper shows and discusses the comparative results of some experiments conducted.
        Speaker: Mr Amar Osman Abdalla ABDELBARI (Researcher at Sudan Atomic Energy, Sudan)
      • 197
        Tracers of High Altitude Pollution Sources and Impact on Mt. Kenya Ecosystem
        Tracers of pollution sources have been used in atmospheric studies to track sources of long distance transported particulate aerosols in the lower and middle troposphere. To identify the sources of suspected pollutants that are responsible for the degradation of glaciers on Mt. Kenya the tracers were used in this study. Mt. Kenya is one of the major sources of water in Kenya and therefore important in sustaining underground and river water levels. Its ecosystem is therefore important in sustainable economic growth, food production and poverty eradication. However Kenya have been experiencing reduction in river water levels and drying of many wetlands resulting in extended arid lands, especially in the neighborhood of semiarid areas. Strong winds and convective systems are known contribute mineral dust particles in the middle troposphere. This species of aerosol particles have an estimated lifetime of weeks and can be transported for long distances, for example the impact of Saharan dust in the Atlantic Ocean and America. The semiarid lands and increasing anthropogenic activities, especially cultivation, within the fast increasing population in Kenya were suspected of impacting on Mt. Kenya ecosystem. However tracing of the sources that contributed to pollution at that altitude remained inhibited due to scanty measurements in the region. In March 2015, during a period of dry and hot conditions, which preceded the long rains, a measurement campaign was carried out at a site on the south-south eastern slopes of Mount Kenya. The site location is at the Equator, at more than 4.7 km above sea level (asl) and is characterized by tropical alpine highland glacier in the neighborhood of high mountain peaks of heights ranging from 4985 to 5199 m asl and Lakes. The campaign mobilized gas and particle monitors, which included a black carbon monitor, and battery powered particle samplers. Gravimetric measurements of collected airborne particles on Teflon filter media; the elemental constituents of those particles, glacier snow/ice and water were used as tracer properties for assessing the source on pollution impacting the site. Water, snow and ice samples were collected into pre-cleaned plastic containers. The filter samples were analyzed using convectional EDXRF spectrometer and the samples of water, snow and ice by TXRF at the Institute of Nuclear Science and Technology, University of Nairobi in Kenya. On filter samples Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn and Pb; the abundant elements were Ca, Ti, Mn, Fe and Zn and in glacier snow, ice and water it was Mn, Ca, Ti and Fe. These analyzed elements are common tracers of mineral dust thus implicating local and distance arid lands and anthropogenic activities as sources of pollution that contribute to the degradation Mt. Kenya eccosystem. However more comprehensive studies are necessary, despite the difficult terrain and conditions. Corresponding Author: Gatari M.J. G. at mgatari@uonbi.ac.ke
        Speaker: Mr Michael J. G. Gichuru (Institute of Nuclear Science & Technology, College of Architecture and Engineering, University of Nairobi, Kenya)
    • 16:15
      Coffee break
    • A10: Development in Electron Accelerators Technology IAEA Board Room B/M1

      IAEA Board Room B/M1

      Conveners: Mr Lixin Shen, TSec Bum Soo Han
      • 198
        Addressing Challenges Posed by Electron Beam Irradiation through Innovation
        Over the past decade, the use of electron accelerators for sterilization and disinfection has made considerable progress and the offer has greatly diversified. The challenges that gamma technology is facing has also raised considerable interest in E-Beam and X-Ray technology as a possible alternative to the use of radioisotopes. However, commercial operation of electron accelerators faces several challenges. The penetration depth of electron beams, even at 10MeV, does not permit to process all of commercial packages that are encountered. Companies operating a single e-beam machine are often confronted to downtime that results in delays in production due to the time necessary to repair. The presentation will introduce an innovative solution that allows overcoming these challenges and was designed and proven through a long and broad experience of using and manufacturing electron accelerators. This solution is based on an optimal mix of electron accelerators types (Linac and HFHV), different energies (10MeV and 5MeV) and different types of ionizing radiation (e-beam and X-ray). In conclusion, a recent example of successful use of this combination will be shown.
        Speaker: Ms Yuwei Zhang (Wuxi El Pont Radiation Co., Ltd., China)
      • 199
        Illinois Accelerator Research Center
        The Illinois Accelerator Research Center (IARC) hosts a new accelerator development program at Fermi National Accelerator Laboratory. IARC provides access to Fermi’s state-of-the-art facilities and technologies for research, development and industrialization of particle accelerator technology. In addition to facilitating access to available existing Fermi infrastructure, the IARC Campus has a dedicated 36,000 sqft heavy assembly building (HAB) with all the infrastructure needed to develop, commission and operate new accelerators. Accelerator infrastructure available for use in collaborative efforts will be detailed. Connected to the HAB is a 47,000 sqft Office, Technology and Engineering (OTE) building, paid for by the state, that has office, meeting, and light technical space. The OTE building contains the Accelerator Physics Center, and with nearby Accelerator and Technical divisions, provides IARC collaborators with unique access to world class expertise in a wide array of accelerator technologies. IARC scientists and engineers from Fermilab and academia work side by side with industrial partners to develop breakthroughs in accelerator science and translate them into applications for the nation's health, wealth and security. Some of the current collaborative efforts will be detailed.
        Speaker: Mr Charlie Cooper (Fermi National Accelerator Lab, United States of America)
      • 200
        A Compact Superconducting RF Accelerator for Electron Beam and X-ray Irradiation
        As commercial and industrial applications of electron beam and x-ray irradiation have developed, new applications have emerged that require very high beam power to create the required radiation field. These new applications require dependable, efficient, high energy, high power electron accelerators. Recent developments in Superconducting Radio-Frequency (SRF) technology can now enable accelerators with lower costs and improved performance. Cryogenic heat loads are dramatically reduced through use of new materials and improved component designs. New cooling methods allow the replacement of complex systems requiring cryogenic fluids with simple robust systems with no fluids. New RF sources can greatly reduce the cost of RF power. Each of these developments has been individually proven and an effort is underway at the Illinois Accelerator Research Center at Fermilab to integrate them into the first prototype of an entirely new class of industrial SRF-based accelerators. These accelerators will enable robust, turn-key operation with very high electrical efficiency. The accelerator prototype under design will be capable of 10 MeV beam, CW operation, and 250 kW of electron beam power. These modular systems are small enough to be palletized and transported to the point of use. Their high electrical efficiency mean that portable power generation systems can be enable their use in mobile applications. The goal is a compact, cost effective, high power accelerator suitable for many of the applications covered by this conference. Fermilab is actively working to build the prototype and identify partners for commercialization. The end product will be a commercially available, robust, turn-key system for applications requiring reliable electron beam or X-ray irradiation.
        Speaker: Mr Thomas Kroc (Illinois Accelerator Research Center at Fermilab, United States of America)
      • 201
        Low-Energy Electron Irradiation for Novel Applications in Medical Production and Pharma
        Currently most $\gamma$ or high energy EB ionizing irradiation processes for medical and pharmaceutical production are provided by external services. Only a few applications rely on low energy electron irradiation: e.g., syringe tub sterilization at high throughput filling lines. But more complex and expensive logistics as well as demands for flexibility in small customized production batches calls for an irradiation processes integrated into the production chain. The simple implementation of irradiation technologies into typical production environments. is hindered by the limited penetration depth of low energy electrons and the expense of multisource arrangements needed for 3D-objects. Therefore, Fraunhofer FEP and partners has developed a new low energy electron irradiation application available for production integrated solutions. To avoid multisource arrangements for homogeneous irradiation of 3D-objects, a toroidal shaped electron beam source was developed. By using high-voltage glow discharge for electron generation, a compact and robust electron source for energies up to $150$ kV was born. Original targeted for treating bulk goods, a single source is perfectly adapted for surface modification or sterilization of 3D products like implants, or continuous feed material like tube packaged parts. First experimental results of operation, the electron generation principle and the first application (seed treatment) will be presented. Liquids irradiation traditionally requires high energy irradiation because of the penetration depth requirements. Especially in the case of vaccine production, virus inactivation by irradiation is very interesting because of the high efficiency in antigen conservation. But high energy irradiation at external facilities is not practicable because of the strong safety requirements. Within an ongoing Fraunhofer funded project, an interdisciplinary team developed a low energy irradiation method for virus containing suspensions to produce inactivated but still very efficient vaccines. Actually results about irradiation technology and vaccine testing will be presented. The new inactivation technology will make vaccine production faster and cheaper with higher efficacy at the same time. Together with some actually additional development directions like: - Miniaturized electron beam sterilization compartment for on-site sterilization of packaged products; - Electron beam modification of cell-therapeutic substrates; we can show an enormous potential for low electron irradiation processes in medical and pharmaceutical production. More flexibility in small batch production and a close production chain inside the facility increase the safety level and the production efficiency at the same time. Low energy electron irradiation will play an important role in this paradigm change over the next years to fulfil the requirements of more than just the healthcare industry.
        Speaker: Mr Frank-Holm Roegner (Fraunhofer Institute for Organic Electronics, Electron Beam and Plasma Technology FEP, Germany)
      • 202
        DC ELV Accelerators: Development and Application
        ELV accelerators are widely used for electron beam processing. The use of these machines enabled to develop the manufacture of a wide range wires, cables and heat-shrinking goods, films, bands and so one. All of them are of high security and reliability during operation as under standard and extreme operating conditions. ELV are DC electron accelerators with high power of electron beam. The efficiency of a conversation of electricity to electron beam power is also high. Budker Institute of Nuclear Physics (Novosibirsk, Russia) had started the activities with ELV accelerators at the 1970 according to the request of former USSR cable industry. From that time over 140 accelerators were delivered inside Russia and abroad. ELV accelerator can be equipped with a wide set of supplementary devices extending the application range. There are systems of ring and double side irradiation, 4-side irradiation system, extraction device for focused electron beam, transportation systems for cable, film and grain. There are special device for improving of dose uniformity during film and band irradiation. ELV accelerators can be easily integrated in the technological processing due to control system based on a computer. We study the requirements of accelerators market and follow the requests of electron beam technologies users. Lifetime of accelerators usually is some tens of year. Very often the modification of accelerator for users is more attractive in a comparison with installation of new machine. So very often old accelerators have upgrade and continue operation. The development of ELV accelerators is concerning with: stability in operation, new energy region (the minimum energy became 200 keV instead of 400 keV. Accelerators with energy less 1.0 MeV can be assembled inside the steel local shielding. There was developed the system after warranty service of delivered accelerators. We are manufacturing ELV accelerator both inside BINP and in collaboration with South Korea or China firms. Accelerator with 400 kW power of electron beam was developed and manufactured together with EB-TECH.co.
        Speaker: Mr Nikolay Kuksanov (Budker Institute of Nuclear Physics, Russian Federation)
      • 203
        Electron Treatment of Seed
        Providing the world´s growing population with nutritious food is an enormous challenge, that solution starts very early in food production. Beside the known chemical seed dressing there is another way for killing pathogens. This environmental friendly, purely physical disinfection of seed, bases on the biocidal effect of accelerated electrons. Electrons are a versatile tool for numerous applications in all fields of industry. Beside the known and established processes in medicine and pharma the electron treatment of seed became more and more important. The electron treatment of seed bases on the biocidal effect of accelerated electrons. The penetration depth of the electrons into every single seed grain can be adjusted via the kinetic energy of the impinging electrons. Thus, the sterilizing effect can be restricted to the surface, pericarp and tegument, without affecting the seed embryo inside the seed grain. The Fraunhofer FEP developed a technology that allows to treats seed in air in a continuous process. Thus, two large plants with throughputs up to 30 tones of cereals per hour were constructed and successfully established in Germany. Large field tests, among others by federal institutes, shows the success and comparability in field yield to conventional seed dressings, without the disadvantages of chemical treatment, like the environmental effects, dressing dust and the high costs of the chemicals. Beside the treatment of cereal seed, FEP and its partners proofed the feasibility of killing bacteria such as E.COLI on sprouting seed. Due to the current demands, after EHEC crises in 2011there is a growing demand for safe pathogen killing measures. Infected seeds were treated with electrons and there germination force, germination rate and load of pathogens are investigated. More than 90 % of the fenugreek and clover samples and more than 80 % of the mung bean samples are sterile, proved with fluid turbidity tests, after electron treatment. Not to influence the embryo, can be proved by testing germination rate and germination force. Both are kept unchanged. Tests show that the treatment of sprouting seed (Mung bean, clover and fenugreek) to reduce bacteria load is possible, without influencing the embryo.
        Speaker: Mr André Weidauer (Fraunhofer Institute for Organic Electronics, Germany)
      • 18:20
        Discussion
    • B10: Radiotracers for New Materials Development Conference Room M2

      Conference Room M2

      Conveners: Mr Gerardo Maghella (Instituto Peruano de Energia Nuclear), TSec Patrick Brisset
      • 204
        Quality Control of Neutron-Absorber Materials for the Nuclear Fuel Cycle. Principle of the JEN_3 Neutron Backscattering Gauge
        It is projected that by 2030 there will be other nuclear reactors in addition to 437 reactors already operating commercially today in the world. A quarter to the third of the spent fuel rods from these reactors must be removed from a reactor every 12 to 24 months and stored between one and two years in the spent fuel pools. This delay allows the decrease of their radioactivity and thus their cooling, in order to facilitate transportation to the reprocessing plant. During that pool storage period, prevention of critically is ensured by the borated stainless steel plates, used as coated of the of the spent fuel pools. In general, this material plays a major role in the nuclear fuel reprocessing industry as a neutron-absorber material. Several metallurgy techniques have been developed for manufacturing the borated stainless steel plates. To ensure a functional of radiation protecting and criticality, this material must meet strict specifications regarding the boron content and uniform distribution of the boron in the stainless steel plate. CEA (French Atomic Energy Commission) has designed several gauges to provide proof through non-destructive inspection that the finished products fully satisfy their intended objectives. The main geometries have been considered: • Backscattering geometry, when the criticality shield must reduce the reflection of neutrons. • Transmission geometry, when the shield must reduce the interaction of exchanging neutrons. In this paper, we present the JEN-3 Backscattering neutron gauge. This gauge contains a neutron radio-isotopic sealed source whose activity depends in the final control and the site constraints. The neutron measurement is affected by randomness of the neutron emission and their interactions with the matter so, the uniform distribution of the boron will be checked by statistical criteria of acceptability. The industrial prototypes are already installed and their performances have been validated in two manufactures of borated stainless steel plates (the first one in Austria and the second one in the US).
        Speaker: Mr Hamid Makil (Commissariat à l'énergie atomique (CEA), France)
      • 205
        Radionuclide Technique in Mechanical Engineering, a Powerful Measrueing Method for Tribological Tasks. Installations at and Services of ZAG Zyklotron AG.
        The Radionuclide Technique in Mechanical Engineering RTM is a powerful and sensitive method to measure online the wear rates at running engines or tribometers in the range of nm/h. The three parts of this technique will be explained. 1. The process of radioactive labelling at a cyclotron, 2. The two possible measurement procedures and 3. The measurement equipment. The installations for machine part activations at the cyclotrons of ZAG Zyklotron AG are shown. Based on measurement examples the possible sensitivity of this method is demonstrated. Special developed activations and the status of implantations of radioactive ions are discussed.
        Speaker: Mr Achim Kleinrahm (ZAG Zyklotron AG, Germany)
      • 206
        Replacing the Isotopic Radiation Sources in Thickness Measurement on X-Ray
        Currently, there is a tendency in the industry by refusing isotopic radiation sources in favor of the X-ray machines. This is due to several factors, chief among them radiation safety and maintenance problems, movement and disposal of gamma-ray sources. Compared to the gamma ray source devices have a number of disadvantages. The spectral energy distribution and therefore change in the spectrum as the radiation passes through the controlled material. Instability of radiation compared with gamma sources. All this complicates the use of X-ray sources for the thickness measurement of materials with different chemical compositions. We offer solutions that reduce the measurement error when using X-ray radiation sources below the 0.2% of the measured value.
        Speaker: Mr Boris Artemiev (ZAO RII MSIA SPECTRUM, Russian Federation)
      • 207
        Development of Thin Layer Activation for Wear Measurement
        Since the early 80s, when a cyclotron was installed in our laboratory, besides the fundamental research also application areas have been established. In the first years of operation a relatively big amount of radioactive isotopes was produced for medical purposes. Parallel with the medical isotope production, a number of other isotopes has been developed for industrial and agricultural purposes. These isotopes were intended to use for radioactive tracing. During the cooperation of national and foreign companies and research institutions the idea of using the radioactive tracers for wear, corrosion and erosion measurements emerged. Appropriate irradiation facilities were elaborated for activation of different parts of different forms and sizes as well as simple pieces of equipment (grinding machine, Microtom, etching desk, etc.) were installed to monitor the wear of the activated parts. During the cooperation real machine parts were activated and investigated in tribometers or test benches. By broadening the range of the materials and samples to be investigated it turned out that the nuclear data, especially the cross-section and yield data for nuclear reactions necessary to estimate the produced activities are poor in some cases, that’s why we launched a nuclear data measurement and compilation program to establish a database for these reactions in cooperation with the IAEA. The materials, which cannot be activated directly were labelled using the secondary recoil activation. The international transport regulations and cooperation partners without license for using radioactive materials in their premises motivated us to elaborate the Thin Layer Activation (TLA) method by using activities under the Free Handling Limit (FHL). The irradiations/activations are performed on a dedicated beam line of our cyclotron laboratory mainly with proton or deuteron activation. The bombarding energy is set to a value so that the activity distribution of the main radioisotope produced is constant up to a given depth of the surface (homogeneous activation). If it is not possible the distribution is set to linear. Single or multiple spots, larger areas are activated into a depth required by the particular task. The depth can be adjusted by altering the irradiation angle. A particular task may require the presence of different radioisotopes in the same sample or in two samples with friction contact. In this case a non-interfering pair of isotopes are chosen. The first measurements are performed by using high resolution gamma-spectrometers in order to assess all isotopes and their activities, the real wear (corrosion or erosion) measurement can be performed by high efficiency detectors (e.g. scintillation crystal) with discrimination to a given radiation of the chosen isotope. During more than 20 years’ experience in Thin Layer Activation we could successfully use both the high activity method and the FHL activations in solving real wear measurement tasks, as well as developed the production of a series of radioisotopes applicable for wear measurements. Our results also extend to the nuclear data measurements, where much more radioisotopes are measured and discussed from the point of view of TLA.
        Speaker: Mr Ferenc Ditrói (Institute for Nuclear Research, Hungarian Academy of Sciences, Hungary)
      • 208
        Industrial Applications of the IEA-R1 Research Reactor in Brazil
        The IEA-R1 is an open pool type research reactor located at the Nuclear and Energy Research Institute (IPEN-CNEN/SP) site and achieved its first criticality on September 16, 1957. IEA-R1 is the largest research reactor in operation in Brazil, with a core composed of $24$ fuel elements with $20\%$ enriched uranium silicide, $4$ control rods (Ag$+$In$+$Cd) and many irradiation positions supplying thermal neutron fluxes ranging from $10^{12}$ to $10^{14}$ n/cm$^2$s. Currently, IEA-R1 is operating at $4.5$ MW on an $8$ hours per day and $4$ days per week cycle. The IEA-R1 reactor is a multipurpose facility used for basic and applied research in nuclear and for the production of radioisotopes for industry and nuclear medicine. For industry, IEA-R1 produces radiotracers and sealed radioactive sources ($^{60}$Co and $^{192}$Ir) for industrial $\gamma$-radiography, as well as doped silicon by neutron transmutation. For radiotracer production, IEA-R1 has been working with a compact local staff (3 persons) and is assisted by the Radiation Technology Centre at IPEN-CNEN/SP, in which there are installed hot cells for high activity handling. Most of the radiotracers produced at IEA-R1 are irradiated in a quartz bulb inside an aluminium vessel; the only exception is for $^{41}$Ar production, where a special device that doesn’t require a hot cell is used. These are the radiotracers produced at IEA-R1 and their applications in industry and environment: - $^{203}$Hg: determination of the mercury mass immobilized in electrolytic cells from soda and chlorine producing industries ($46.6$ days and $0.28$ MeV). - $^{131}$I and $^{82}$Br: flow rate measurement and residence time distribution (RTD) studies in rivers, lakes and wastewater treatment plants ($8.04$ days and $36$ h, $0.36$ MeV and $0.55$ MeV, respectively). - $^{192}$Ir: environmental studies, in the form of a premixed sand (glass powder plus activated iridium), to study drag sediment in river ($73.8$ days and $0.32$ MeV). - $^{198}$Au: representative study, in real conditions, of the impact of great civil works for the construction of important artificial harbour, airport and hydroelectric reservoir, by labelling sand to be removed from the bottom with emulsion of gold ($2.7$ days and $0.41$ MeV). - $^{41}$Ar and $^{79}$Kr: study the gas phase of fluidized cracking catalytic plants ($110$ min and $35$ h, $1.29$ MeV and $0.51$ MeV, respectively). - $^{140}$La: study the solid phase (catalysts) of fluidized cracking catalytic plants in petroleum refineries ($40$ h, $1.16$ MeV). For doped silicon production, a device that affords the best axial and radial uniformity of the neutron dose is used. These doping uniformities as well as the doping accuracy are determined using resistivity values, showing an excellent doping quality. A recent improvement was the development of an irradiation system to produce gaseous radioisotopes ($^{41}$Ar and $^{79}$Kr), delivering the activated gases directly into the shield bottle without handling and dose exposition for operators, instead of via small quantities (batches), through quartz ampoules containing these noble gases.
        Speaker: Mr Wilson Calvo (Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP), Brazil)
      • 18:10
        Discussion
    • A11: Safety and Security Perspectives of Radiation Facilities IAEA Board Room B/M1

      IAEA Board Room B/M1

      Conveners: Mr András Kovács (Atomic Energy Engineering Company Ltd), TSec Sunil Sabharwal
      • 209
        Upgrading Safety and Security of Gamma Irradiation Facilities – Possibilities and Limitations
        Improvement of safety and security are important goals of gamma irradiation facility upgrades, besides improvement of more economical and product quality related features. Safety of gamma irradiators comprises three complexes which may require upgrades: - Shielding of radiation when in operation and in stand by - Protecting people from entering or staying inside the irradiation room - Preventing of dispersal of radioactive material A more general problem with respect to safety is safety culture, which is on very different levels at different places in the world. This is not limited to radiation protection but is a problem also in other fields of commercial and daily life (road traffic, electricity, health and safety at work). Here “upgrades” may be required as well. Fortunately, respect from radioactivity increases safety attitude, at least at the beginning. Limiting factors not only for upgrades but sometimes also for the safety level of new installations are - Lack of financial resources - Lack of know how - Lack of safety culture - “cheap – cheaper – cheapest” business culture Security is all about preventing theft of radioactive sources for terroristic goals and other abuse. Here it may be easier to overcome a possible lack of financial resources or of know how due to the interest of the international community to eliminate terroristic threats.
        Speaker: Mr Manfred Frenzel (GSG International GmbH, Germany)
      • 210
        Safety Improvements of an Industrial Irradiaiton Facility
        The operational experience feedback is a powerful tool to implement corrective actions after an incident. These corrective actions, discussed and adequately defined with the regulator consist in a powerful way to improve the safety of a facility. Belgium hosts two cobalt-60 industrial irradiators that have now been used for more than 30 years. During this period, the facility dealt with a few incidents that have driven improvements through implementation of adequate corrective actions in the existing design and processes. The licensee promoted transparency towards the regulator (Bel V and the FANC) and declared all technical events related to safety and radio-protection. The licensee has proposed technical and organisational solutions that were reviewed independently by Bel V to avoid the recurrence of similar incidents. Short term improvements were immediately set-up after the incidents. Mid-term improvements were also implemented. For more complex issues such as the removal of the broken sources, a long term planning was established requiring the participation of a large number of stakeholders: transport, safety authorities, waste disposal facility,… For this type of issue a long term approach was favoured. The will of the licensee to declare incidents to safety authorities and to implement adequate corrective actions in agreement with the safety authorities, allows a regular improvement of the facility in order to keep it up to date with safety standards and best practices. This proactive management of incidents and corrective actions has also strongly increased the safety culture awareness of the operators.
        Speaker: Mr Frederic Schmitz (BelV, Belgium)
      • 211
        Upgrading and Continuous Improvement of ININ Gamma Irradiation Facility
        The highlights of the updated activities at ININ GAMMA IRRADIATION PLANT facilities and improvements as well as in the irradiation process, to make it a multipurpose plant with greater capacity for products processing are shown in this work. The ININ gamma irradiation plant has a 6500 JS irradiator originally designed for processing medical disposables. Since its start in 1980, the irradiation Plant have been increasing their annual hours of operation and as a result their number and diversity of clients from the food industry, pharmaceutical companies, medicines and medical devices manufactures and health care products, to such an extent that by the year 2000 and 2011 started operations in the country, respectively, two new irradiation facilities of private capital. The importance of implementing and maintaining a certified quality management system, improving ergonomics, stablish a preventive maintenance system and critical spare parts inventory, maintain the operating license as a result of good radiation safety practices, and good customer relationships to support compliance with their regulations are remarked. Results are also presented in improved uniformity of dose delivery, dose catalog offered to clients, cobalt-60 reloads (with corresponding activities) and annual processing capacity obtained.
        Speaker: Mr Miguel Alcerreca (National Institute for Nuclear Research, ININ, Mexico)
      • 212
        Enhancing Nuclear Security System of Irradiation Facility SIBO INRA/Tangier Morocco
        Abstract Around the world, radioactive sources have been widely used for decades to benefit humankind—to diagnose and treat illnesses, monitor oil wells and water aquifers, irradiate food to eliminate microbes, and for many other uses. However, the malicious use of radiological sources poses a significant threat globally. As Irradiation facility for research the goal of this paper is to show a case study of application of nuclear security and nuclear security culture code of contact in irradiation facility using cobalt 60. And will show the necessary work done to achieve the goal of protection of radioactive material and continue working in safe conditions. This objective couldn’t be achieved without the collaboration of all department involved in security and nuclear safety. In all irradiation facility in the world the level of this control is always done to achieve safety procedures in usual work on this field. In this work we applied the nuclear security and nuclear security culture procedures in order to define the type of system used to achieve the global objective in accordance with Global Threat Reduction Program to reduce the threat of a Radiological Dispersion Device (RDD) in collaboration with The United States Department of Energy’s National Nuclear Security Administration (NNSA). This work has been done with other operation in the same facility as local upgrading of cobalt 60 in our irradiator In Tangier and upgrading of safety and technical system of the irradiator made in collaboration with IAEA , detail of this works are presented in others scientific papers. The objective of this paper is to share a local experience in upgrading security with return of experience in practice and very good collaboration with General direction of national security and all departments involved in security and nuclear safety
        Speaker: Mr Mohammed MOUHIB (INRA Tanger, Morocco)
      • 213
        Development and Application of Electron Linear Accelerator of CIAE
        As an artificial radiation source, electron linear accelerator is not only widely used in basic science research, but also more and more used in industry, agriculture, medical and environmental protection and other fields. China Institute of Atomic Energy (CIAE) began to engage in research and development of electron linear accelerator from its early establishment, and has converted the research outcomes successfully into products and services in the cause of China's prosperously development. These outcomes are mainly divided into two categories. The first category is the Non-Destructive Testing (NDT) electron linear accelerator (LINAC). In the 1990s, CIAE successfully developed China's first NDT electron LINAC, then successively developed a series of accelerator products with different X-ray beam energy like 2MeV, 4MeV, 6MeV, 9MeV, the detection thickness of equivalent steel reach to 380 mm, mainly used in the detections of weld joints of thick-walled pressure vessels, pipes, boilers, valves equipped in petrochemical industry, thermal power plant and nuclear power plant, testing of the defect of key components of the high-speed train, rocket engine and so on. The national standards of NDT electron LINAC was drafted by CIAE and the corresponding international standard project launched to International Electro-technical Commission (IEC) from CIAE has been started and is progressing well; The second category is electron LINAC for radiation processing. The first radiation facility based on high-power high-energy electron LINAC developed by CIAE was put into trial operation in 2007. The Electron Beam (EB) energy of this accelerator is 10MeV, and the power exceeded 15kW, which was the highest power of the same type around that time. Currently, the EB power of this type has reached 20KW, and was capable of stable operation. Number of radiation processing enterprises has purchase this type of accelerators, which are used for garlic, tea preservation and pet food, seasoning sterilization. In China, R&D direction of NDT electron LINAC is miniaturization and digitalization, while for irradiation accelerators, scientists and engineers are striving to improve the EB power or X-ray conversion efficiency.
        Speaker: Mr Guolong Yu (China Institute of Atomic Energy, China)
      • 10:40
        Discussion
    • B11: Seeing the Invisible: Structure Imaging - Safe and Effective Industry II Conference Room M2

      Conference Room M2

      Conveners: Mr Ghiyas Ud-Din (Pakistan Institute of Nuclear Science and Technology [PINSTECH]), TSec Patrick Brisset
      • 214
        Investigation of Two-Phase Flow Behavior Across a 90 Degree Horizontal Bend: CFD Simulation and Gamma Computer Tomography Validation
        Investigation of two-phase (gas-liquid) flows is of vital importance due to their numerous applications in process industry. In the era of high speed and high capacity computers, such process engineering investigations are carried out using the Computational Fluid Dynamics (CFD) simulation. But there is always a need to validate fascinating CFD simulation results with experimental technique. Gamma Computer Tomography (CT) provides a means for validation of CFD results. In this technique, transmission property of gamma rays is used to exploit density distribution of materials in the process under investigation. This procedure is carried out by obtaining several radiographic projections of the process followed by image reconstruction using various image reconstruction algorithms. Two-phase flow regimes in straight pipes are well established and reported in literature but a little has been focused to define these flow regimes across bends. This paper presents investigation of two-phase (air-water) flow behaviour across a 90 degree horizontal bend for a range of superficial velocities of phases using CFD and gamma CT techniques. Simulation of the system is carried out using the software FLUENT 6.3.26 while computational grid was generated using the pre-processor GAMBIT 2.4.6. Euler-Euler multiphase model is used while turbulence is incorporated using the Standard K-Epsilon model. Validation of simulation results is carried out using the First generation Gamma CT system GORBIT. The 90 degree horizontal bend is scanned at various cross-sections for this purpose. Stratified flow patterns with major portion of void at the upper section of bend have been observed on the inlet and outlet of bend on the studied operating parameters. However, the void has been noticed to move towards the inner curvature of bend at the central location. Key Words: Two-phase flow, Computational Fluid Dynamics, Gamma computer tomography, bends
        Speaker: Mr Ghiyas Ud-Din (Pakistan Institute of Nuclear Science and Technology [PINSTECH], Pakistan)
      • 215
        New Developments on the Automatic Gamma Column Scanner
        Gamma transmission scanning of distillation columns is one of the most frequently used radioisotope techniques in industry. Recently, a new version of automatic gamma column scanner was developed under the cooperation of Korea Atomic Energy Research Institute (KAERI) and GammaTech Inc. to facilitate high quality gamma scanning services to local industry. The scanner controls the movements of the source and the detector, records radiation counts and shows graphically the result of scanning on the screen. Instead of using multiple lines (guide cables, holding cable, signal cable and ruler) for the source and the detector in manual column scanning system, only one line is used in each side by employing tensioning tools and wire signal cable in the automatic system. Remarkable improvement in both hardware and software were made in the new version. The new system features shockless movement of a source and a detector for their precise control which is pivotal for acquiring measurements with high confidence. Software and associated hardware of the system was built with the products that have a worldwide reputation as standard tools in engineering fields to make the maintenance as well as further improvement more convenient. The improvements in the tensioner system, the encoder and its calibration method, radiation detection system and gamma energy spectrum, control box, software program and its operation methods are introduced. The procedures for installation and operation of the scanner are presented.
        Speaker: Mr Joon-Ha Jin (GammaTech Inc., Korea, Republic of)
      • 216
        Radiotracer Applications in Industry and Environment
        Radiotracer techniques are widely used for troubleshooting, measurement of hydrodynamic parameters, flow visualization and evaluation of design of process equipment in industry and environment because of their many advantages over conventional tracers. The main advantages of radiotracers are their physico-chemical compatibility, high detection sensitivity, ability of in-situ detection, availability of a wide range of radiotracers for different phases, non-degradability in harsh industrial environment and limited memory effects. In a radiotracer application, the radioactive material in a suitable physo-chemical form, similar to that of the process material, is instantaneously injected into the system at the inlet and its passage is monitored at the outlet or along the system at strategically selected locations using collimated radiation detectors. The monitored tracer concentration data is plotted as a function of time and interpreted to obtain qualitative as well as quantitative information about process parameters, hydrodynamic behavior of the system and occurrence of malfunctions, if any. The commonly carried out applications of radiotracers in industry and environment across the world include: • Leak detection in buried pipeline and heat exchangers • Mixing/blending studies • Flow rate measurements • Studies on residence time distribution in process vessels • Sediment transport investigations in port • Effluent dispersion studies in water bodies • Wear rate measurements • Radioactive particle tracking technique for flow characterization • Radiotracer applications in oil field investigations These applications across the world are either carried out by private companies or atomic energy establishments of the different countries. The end-user industries have been enormously benefitted from these applications. In recent years, some new developments have also taken place in tracer techniques. During the presentation, a few case studies recently conducted in India and emerging trends in radiotracer applications in industry and environment will be discussed.
        Speaker: Mr Harish Jagat Pant (Bhabha Atomic Research Centre, India)
      • 217
        Tomographic Methods for Multiphase Flow Measurement
        Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain. These are related to reducing measurement uncertainties arising from variations in the flow regime and the fluid properties, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. Tomographic imaging is a powerful tool to unravel the dynamics of the gas liquid distribution in multiphase pipe flow and is regularly applied to provide reference data in the development of multiphase flow meters and for experimental validation and development of flow models. A high-speed $\gamma$-ray tomograph developed at the University of Bergen has been developed for this purpose. The image capture rate in the example shown is $100$ frames/second, however, the system is capable of identifying the gas-liquid distribution at rates up to $1000$ frames/second. The high-speed imaging systems are designed for use in laboratories and at test facilities and are not suitable for in situ or permanent installations. For this purpose simpler systems with fewer projections are applied. These are referred to as tomographic measurements, tomometry or agile. An example of a $\gamma$-ray system using one source and multiple beams, will be presented. This concept can be applied as a stand-alone meter or to provide accurate measurements of the gas volume fraction for a multiphase flow meter. The pipe flow is split into temporal segments of which the gas volume fraction is measured. One $^{241}$Am source with principal emission at $59.5$ keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second and eventually the third are positioned to the sides so that these beams are close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the instantaneous cross sectional gas-liquid distribution, i.e., the instantaneous flow pattern. By counting the intensity in short time slots ($< 100$ ms), rapid variations are revealed. In conclusion the sensitivity to temporal flow regime variations multiple beams are considerably reduced by this multiple beam principle and is now implemented in commercial meters.
        Speaker: Mr Geir Anton Johansen (University of Bergen, Norway)
      • 218
        Determination of Interfaces in Packed Columns by Using Sealed Sources”
        Process involved is the application of nuclear gauges to evaluate interfaces of bed in packed columns, which are used in different industries, petrochemicals, etc. In this case, different types of packing have been used within a PVC column in order to analyze the response of the attenuation of the gamma radiation that different materials with different density present when a radioactive source whose beam passes through them is used. Thus, the results obtained by the detector from the attenuation of radiation gives information about the distribution and height of the packing material within the column. The present study performed in the laboratory consisted in the determination of phases within a column packed with material of different density, to which a gamma profiling was done by means of a source-detector system, in order to establish the interfaces of the packing distributed within the mentioned column. Cs-137 source (Activity = 10 µCi) was used, with a scintillation detector mobilized by a stepper motor (v = 6.6 m/s) and the packing consisted of several types: sand and gravel, fine gravel, clay, coarse gravel, fine sand, air and water. This experiment was carried out with 02 types of measurement: 2 measurements/s and 5 measurements/s and it was demonstrated that that this technique used to estimate packing heights and interfaces is very efficient and that with a profile made with more measurements per second, best results with lower percentages of variation are obtained.
        Speaker: Mr Gerardo Maghella (Instituto Peruano de Energia Nuclear, Peru)
      • 219
        A Gamma Ray Computed Tomography for Investigating the Wood Structure
        The gamma ray computed tomography (CT) technique represents an effective solution for the control of the internal of the objects and allows to obtain, after measure and appropriate treatment of the data, a mapping of the inside of an object. The idea is to control and to characterize the status of several trees of the forest of Mamoura. We will begin by measuring thickness of the bark and trying to identify the rings of growth.
        Speaker: Mr Abdelaziz saadaoui (National Center of Energy Sciences and Nuclear Techniques (CNESTEN), Morocco)
      • 10:30
        Discussion
    • 11:00
      Coffee break
    • A12: Radiation for Environmental Protection II IAEA Board Room B/M1

      IAEA Board Room B/M1

      Radiation for Environmental Protection II

      Conveners: Ms Erzsebet Takacs (Centre for Energy Research, MTA), TSec Sunil Sabharwal
      • 220
        Virucidal Potential of Gamma Radiation
        Enteric viruses are a major cause of human water and foodborne diseases. These type of viruses primarily infect the intestinal tract through ingestion of contaminated water or food. Enteric viruses, like norovirus (NoV) and adenovirus (AdV), can enter the environment through the discharge of waste materials from infected individuals and be transmitted back to susceptible individuals. The stability of these viruses and their presence in waters and food can thus cause serious implications on public health. In this scenario, gamma irradiation could be an efficient technology to achieve elimination of viral pathogens. The goal of this study was to investigate the inactivation by gamma irradiation of murine norovirus type 1 (MNV-1), as a NoV surrogate, and human adenovirus type 5 (AdV-5) in six different aqueous substrates and two types of fresh berry fruits. Phosphate Buffer Saline (PBS), demineralized water, tap water, Fetal Bovine Serum (FBS) and aqueous solutions of 10% and 50% FBS as well as fresh strawberries and raspberries, were inoculated either individually with MNV-1 and AdV-5 or with a viral pool of both viruses. The spiked samples were irradiated in a Co-60 chamber at several doses 0.87 up to 11.35 kGy at a dose rate of 1.6 kGy/h. For fresh berries samples, the viruses were recovered from spiked samples and then purified and concentrated by low speed centrifugation. The infectivity of viral particles of MNV-1 and AdV-5 was tested by plaque assay using Raw 264.7 and A549 cells, respectively. D10 values and virucidal efficiency of gamma irradiation were estimated for each virus and substrate. A reduction on MNV and AdV titers of 4 log10 PFU/ml was achieved after irradiation at 3 kGy on PBS, demineralized and tap water suspensions. However, it was found that MNV-1 and AdV-5 were approximately 3 times more resistant to gamma radiation when irradiated in FBS suspensions. Concerning the obtained results for fresh berries, a reduction on MNV-1 and AdV-5 titers of 2 log10 PFU/g was achieved after irradiation at a dose of 4 kGy. Non-linear inactivation survival curves were obtained for both virus in fresh berries, leading to the detection of infective viral particles at a dose of 11 kGy. MNV and AdV indicated to have the same radioresistance when irradiated in a viral pool or in individual viral suspension for all tested matrices. The viral inactivation by gamma radiation was found to strongly depend on the substrate where the viruses are suspended. The study of viral behavior in different substrates could open new insights on the inactivation mechanism caused by gamma irradiation. The selection of the gamma radiation dose for the disinfection treatment of berry fruits, must achieve the balance to guarantee food safety and preserve food quality. The irradiation process presented virucidal potential. This technology can be an effective virus mitigation tool to treat polluted waters, which are the major vehicle of contamination for minimally processed food products.
        Speaker: Ms Sandra Cabo Verde (Instituto Superior Técnico, Portugal)
      • 221
        Removal of Wastewater Pharmaceutical Chemical Contaminants Using AOPs
        Quantitatively removing all remaining traces of pharmaceuticals such as antibiotics and estrogenic steroids from effluent wastewater is essential before its further use or release into the environment. In particular, the presence of antibiotics and even their metabolites in wastewaters can enhance the proliferation of antibiotic-resistant bacteria such as MRSA and ND-1. Unfortunately, conventional primary and secondary water treatments that rely mainly upon adsorptive and chemical-physical processes have been demonstrated to be insufficient for quantitative large-scale treatment. These removal treatments are considerably complicated by the presence of much higher levels of other water constituents such as dissolved organic matter (DOM) and carbonate. Therefore, to prevent increasing levels of antibiotics entering environmental waters, additional treatment using radical-based, advanced oxidation processes (AOPs), are being considered to augment our traditional water treatments. In real-world waters most AOPs utilize the hydroxyl radical (HO•), which can be created using a variety of techniques including combinations of ozone, hydrogen peroxide and UV-light. O3/H2O2, O3/UV-C, and H2O2/UV-C. Other AOPs that produce a mixture of reducing and oxidizing radicals include the light irradiation of titanium dioxide, sonolysis, or the irradiation of water via electron beams or γ rays. Once these radicals are generated the dissolved oxygen present will predominately react with the reducing hydrated electron or hydrogen atoms produced. However, the deliberate addition of a compound such as persulfate to these waters can augment HO• reactions through the concomitant production of the sulfate radical (SO4-•) by the reaction of both these two reducing radicals. While this is a promising enhancement in the AOP treatment methodology the effectiveness of the sulfate radical augmentation approach must be fully established before its use at large scale. In particular, the cost-effectiveness of this approach will depend upon the reactivity of the sulfate radical with other water constituents. Therefore, we have performed electron pulse radiolysis measurements to determine reaction rate constants for hydroxyl and sulfate radicals with a large number of DOM fractions from various sources. The sulfate radical rate constants were found to be effectively independent of the DOM aromatic/ aliphatic constituent fractions, and in general about an order of magnitude slower than determined for the analogous HO• radical reactions. The slow reactivity of the sulfate radical with DOM is encouraging, as it would allow a greater fraction of these radicals to react with the contaminants present at much lower concentrations. To further investigate this, we have also now performed preliminary measurements on the use of sulfate radicals to remove low-levels of beta-lactam antibiotics in the presence of different DOM species. Kinetic and efficiency data for penicillin-G in the presence of varying ratios of Suwannee River fulvic acid and Elliot Lake humic acid have been determined and will be reported.
        Speaker: Mr Stephen Mezyk (California State University at Long Beach, United States of America)
      • 222
        Applications of Radiation Technology in Control and Treatment for Environmental Pollution
        Radiation technology including electron beam and γ-ray irradiation has great potential in the field of environmental protection due to its special characteristics. The investigations and applications of radiation technology in the treatment of wastewater, waste gas and solid waste are introduced in this paper, including the treatment of printing and dyeing wastewater, paper mill wastewater, nitroanilines, halogenated flame retardants, endocrine disrupting chemicals, algal toxin, volatile organic contaminants and sludge etc., and the removing of SOx and NOx in coal-fired and automobile exhausts. The degradation efficiency of these organic pollutants by electron beam or γ-ray radiolytic degradation is discussed in various conditions, such as different initial concentrations, irradiation doses, pH values, solvents, radiolysis systems and the addition of H2O2 etc. Besides, the radiolysis products of certain pollutants are listed and radiolytic degradation mechanisms of these organic pollutants are illustrated. These results demonstrate that radiation technology is an effective method to degrade the organic contaminants, especially the persistent organic pollutants, hydroxyl radicals and hydrate electrons play significant roles in the radiolysis of organic pollutants. In addition, the limitations and the future tends of radiation technology applied in the environmental protection are also discussed.
        Speaker: Mr Ming-hong Wu (Shanghai University, China)
      • 223
        Application of Mobile Electron Beam for Remediation of Soil and Groundwater Contaminated with Leachate from Animal Carcass Burial Sites
        Leachates of livestock burial sites have raised a concern regarding their potential impact on the environment and public health in Korea. They contain high concentrations of organic and inorganic contaminants, and pathogenic microorganisms such as Campylobacter jejuni, Salmonella spp., Clostridium perfringens, and Shigella spp. Several studies have attempted to remove contaminated groundwater by leachates, but an effective method has not been found. Thus, the objective of this study was to treat leachates from livestock burial sites using a combined process of pre-treatment and an electron beam. The pre-treatment system consists of two columns: activated carbon and zeolite. Leachates used in this study were collected from groundwater near a livestock burial site located in Gyeonggi-do, Korea. The removal efficiencies of suspended solids and total organic carbon were 98% and 77% by an activated carbon process, respectively. NH3-N was removed about 80% through the zeolite process. In addition, microorganisms showed a removal efficiency of 99.99% using an electron beam at an absorbed dose of 2 kGy. Consequently, the combined processes of pre-treatment and an electron beam can be applied to the remediation of groundwater contaminated by leachates.
        Speaker: Mr Seungho Yu (Atomic Energy Research Institute, Korea, Republic of)
      • 224
        Electron Beam Treatment for Potable Water Reuse: Removal of Bromate and Perfluorooctanoic Acid
        Water availability is a major problem facing many regions around the world. To meet growing residential and agricultural needs, effective technologies have to be adopted to address microbial and chemical contaminants as part of water reuse programmes. The underlying hypothesis was that electron beam (EB) technology can breakdown the emerging contaminants of concern in water reclamation and reuse projects. We also hypothesized that the inactivation and elimination of contaminants by EB technology can be achieved cost-effectively. Having this technology in the “tool-box” of water reclamation technologies would open up innovative high-value, commercially-viable, and environmentally sustainable solutions and strategies for water reuse. In this study, EB irradiation was investigated as a method for removing bromate and perfluorooctanoic acid (PFOA) from a synthetic water designed to simulate a treated wastewater intended for potable water reuse. In the absence of oxygen, an exponential model was able to relate bromate concentration to absorbed dose. However, a more complex model was needed to describe PFOA defluorination, so a model was developed that assumed formation of one partially defluorinated intermediate and this model was used to describe the relationship between free fluoride concentration and absorbed dose. Nitrate negatively affected the removal of bromate and the dose constant was inversely proportional to the nitrate concentration as predicted by a simple model that assumes the presence of radical scavengers. In contrast, the presence of nitrate improved the degradation of PFOA, possibly due to formation of oxidizing radicals or by other reactions of nitrate degradation products. Fulvic acid and alkalinity exerted negligible influences on bromate removal. Fulvic acid dampened the defluorination efficiency, probably due to the scavenging of oxidizing radicals such as the hydroxyl radical ($^\bullet$OH). Alkalinity was found to accelerate PFOA defluorination, possibly because of the formation and reactivity of the carbonate radical (CO$_3^{-\bullet}$). As pH increased from $5.0$ to $7.3$, the dose constant for bromate removal increased from $0.45/$kGy to $0.69/$kGy, but it barely changed when pH was further increased to $9.0$. In the presence of oxygen, both contaminants were degraded less efficiently and showed more complex patterns of degradation. Pretreatment to remove dissolved oxygen would probably be needed to apply EB in practice for degradation of bromate and PFOA.
        Speaker: Mr Suresh Pillai (National Center for Electron Beam Research, United States of America)
      • 225
        Changes in the Biological Degradability and Toxicity of Sulfonamide Antibiotics in Activated Sludge and River Water due to Ionizing Radiation Treatment
        During conventional wastewater treatment, the removal of pharmaceutical compounds is usually inadequate as most of the xenobiotics show high resistance to biological decomposition by activated sludge. This deficiency can be counteracted by application of ionizing radiation treatment that leads to oxidation of organic molecules mainly by reactions of hydroxyl radicals. Oxidation may result in a complete solution to the final disposal of pollutants with no further purification steps required, but may also contribute to formation of biodegradable, less harmful transformation products. The biodegradability and toxicity have been examined on $10^{-4}$ mol$/$dm$^3$ sulfonamide antibiotic solutions with considerably different chemical structure (sulfanilamide, sulfaguanidine, sulfathiazole and sulfamethoxazole) and their products at different stages of oxidative decomposition. The biodegradability in activated sludge and freshwater has been specified by the ratio of the biological and chemical oxygen demand (BOD/COD), while the toxic properties have been evaluated by activated sludge respiration inhibition tests and acute toxicity experiments done on *Vibrio fischeri*, *Pseudokirchneriella subcapitata* and *Daphnia magna*. Test organisms were placed under the exposition of same loads of test substances and the interfering effects of H$_2$O$_2$ forming during irradiation procedure have been eliminated. Initial sulfonamide solutions inoculated with activated sludge showed low BOD/COD ($0.16$–$0.21$), while complete resistance has been observed when river water was used as inoculum. The biodegradability continuously increased as a function of absorbed dose in both matrices and ready biodegradability (BOD/COD $\sim 0.7$) has been reached at $1.5$ kGy and $2.0$ kGy in case of activated sludge and river water, respectively. This difference in absorbed doses means that higher degree of oxidation is needed, when sulfonamides are subjected to river water community, to achieve same biodegradability level under same time as in case of activated sludge. Nevertheless, already a few tenth kGy of absorbed dose led to increment in biological availability. Activated sludge respiration inhibition tests showed no toxic effects of both initial and treated solutions. Growth inhibition on *Pseudokirchneriella subcapitata* has been reduced during treatment. *Vibrio fischeri* was susceptible to treated solutions, as the inhibition increased in case of sulfamethoxazole and sulfathiazole. Mortality of *Daphnia magna* considerably reduced in treated solutions, with the exception of early products of sulfathiazole. It can be concluded that biological treatment at conventional wastewater treatment plants is not adequate for removal of sulfonamide antibiotics. Nevertheless, ionizing radiation led to formation of products biologically degradable by activated sludge. Notable toxic effects of initial sulfonamides have been observed on *Daphnia magna* and *Pseudokirchneriella subcapitata*. These effects generally reduced in treated solutions, but increased toxicity has been also detected in some cases. Experiments done on natural water samples showed that there is a possibility of transformation product removal by biological processes taking place under natural conditions. However, this process may take a long time that ensures probability for manifestation of adverse effects on the state of biological community, or ecosystem.
        Speaker: Mr Gyuri Sági (Hungarian Academy of Sciences Centre for Energy Research, Hungary)
    • B12: Radiation Techniques for Industrial Processes Optimization and Safety II Conference Room M2

      Conference Room M2

      Radiation Techniques for Industrial Processes Optimization and Safety II

      Conveners: Prof. Geir Anton Johansen (University of Bergen), TSec Patrick Brisset
      • 226
        Radiotracer Residence-Time Distribution Method in Diagnosing Industrial Processing Units: Case Studies
        Radiotracers are unique in troubleshooting and diagnosing industrial processing units in harsh and opaque field conditions; the success of radiotracers is primarily due to their certain advantages such as online detection without shutting down or disturbing the process. The paper gives examples showing how the information obtained by radiotracer experiments is used to analyse the operation of industrial processing units, to eliminate troubles and to optimise the performance of processes. Radiotracer residence time distribution (RTD) measurement has been applied to investigate the pulp flow characteristics in the superphosphate production chamber using the radiotracer 51Cr impregnated in the solid phase of the pulp in the mixing chamber; the mathematical model constructed on the basis of the experimental RTD showed an unsatisfactory functioning of the reactor; ways were proposed to correct this shortcoming, both in the existing chamber and in that which was being designed for a new plant. Characterization by radiotracer RTD of flow dynamics in laboratory and pilot-plant molecular sieves columns dehydrating organic liquids is another case study. Experiments with 113mIn radiotracer in 0.01M aqueous solutions of EDTA have been carried out to investigate the fluid flow dynamics in columns of three different diameters filled with molecular sieve spherical particles. The dependence of the fitting of experimental with theoretical RTDs upon the column diameter-to-particle diameter ratio was found and rather bad fitting for ratios smaller than 10 were observed. The influence of these phenomena on the adsorption process was investigated.
        Speaker: Mr Jovan Thereska (Institute of Applied Nuclear Physics, Tirana, Albania)
      • 227
        Investigation of the Multiple Side Injections on Hydrodynamics of the Gas-Solids Fluidized Bed Using Radiotracer Based Techniques
        Introduction Fluidized bed reactors are the core of the chemical industries. The contact between fluid and solid phase plays an important role in the overall yield and performance. The liquid injection of the reactants has tremendous application in the various industries such as polypropylene production, catalytic cracking, coating and drying etc. These processes are occurred in the fluidized bed reactors in which precursors are added to the reactor in atomized form through side injections. The jetting phenomena affect the system locally as well as globally and may change the solid recirculation profile in the reactors. These recirculation profiles contribute to the solid mixing and hence the quality of fluidization. The present works emphasis on the effect of the multiple injection(s) on the solid distribution and velocity field via radiotracer based techniques. Experimental Methodology The experiments are carried out at three different air inlet velocities, which correspond to 1.5, 2 and 3 Umf. For each air inlet velocities, experiments are performed with secondary gas injection through single and two side nozzles (placed at the same and different planes) operated at three different nozzle flow rates (80,100,120 LPM). Glass beads of 660 micron size and density 2500 kg/m3 is used in all the experiments. The solid distribution and solid velocity profiles are estimated using the gamma ray densitometry and radioactive particle tracking (RPT) technique respectively. Densitometry provides line averaged attenuation measurement for each radial location. The term “densitometry” refers to measurement of the density of a material by determining the degree to which that material attenuates radiation of a given energy. By using Beer-Lambert's law, the phase holdup can be calculated along the chord length in which the attenuation in the radiation is measured. In RPT motion of a single radioactive particle, which has same size, shape and density as of the other particles, is tracked by using NaI(Tl) scintillation detectors. In current experiments Sc-46 embedded in glass beads is used as a tracer particle. Results and Discussions Densitometry and RPT experiments are performed for different nozzle configurations and flow rates. The time average radial solid distribution profile is estimated at different axial planes. Figure 1 shows the comparison of solid volume fraction at the nozzle injection plane. The bed is operated at 3 Umf at different nozzle injection velocities. Results indicate that compared to without nozzle case with nozzle injection cases show higher fraction of solids Similarly, The other experimental finding will be addressed in full paper. Conclusions It was observed that most of the injected gas flow near the injection wall even at the higher flow rate and resulting in the low solid fraction at the wall in the case of single nozzle injection. The multiple nozzle injection (their location and configurations) have significant impact and depending upon injection velocity the second nozzle may increase or decrease these effects.
        Speaker: Mr Jitendra Singh Rawat (Indian Institute of Technology-Guwahati, India)
      • 228
        Radiotracer and Sealed Source Technologies for Measurements in Industry
        The field of radiation technology came into being right at the discovery of radioactivity in 1896 by Henri Becquerel. In the coming years, several useful applications of radiation influenced the development of various radiation detector and analysis systems so that qualitative observations can be converted to precise measurements of energy, intensity and location of radiation. Some of these major applications include medical applications, industrial applications, high energy physics and nuclear security. Various means of development of artificial radionuclides and their transformation to useful radiotracers were explored keeping in view of these applications. Portable radionuclide/radiotracer generator systems were established for on-site production of radionuclides which have proved very successful in medical and industrial applications. The objective of this presentation is to give an overview of the applications that are driving radiation technology research for making useful measurements. Keeping in view of the substance involved in subject research field and my special field of research, the talk is focused on radiation technology for measurements in industrial applications. The principle and applications of radioisotopes for making measurements and troubleshooting in industry will be discussed. The development of various nucleonic control systems for on-line measurements in industry will be presented. Thin Layer Activation technique for wear measurements in industrial systems will become under discussion. In addition to this, radiotracer applications for industrial process optimization will also be covered. Modern day approach for diagnosing complex industrial systems (multiphase flow systems) using radiotracers in combination with Computational Fluid Dynamics (CFD) technique will also be elaborated during the presentation. **Key words:** Radiation technology, application areas, radiation detection and measurement systems, industry, radiotracer, nucleonic control systems, CFD
        Speaker: Mr Ghiyas Ud Din (Pakistan Institute of Nuclear Science and Technology [PINSTECH], Pakistan)
      • 229
        Radioisotope Techniques for Detection of Coking in Liquid Flow through a Solid Phase in a Lab-Scale Distillation Column's.
        The petrochemical industry is one of the most important sectors of radioisotope technology applications. The distillation columns are considered as one of the most critical components in oil refineries. In packed bed distillation columns, the coking phenomenon is likely to occur inside the packing (solid) through which a liquid is flowing. The aim of the proposed work is to try to address the coking phenomenon as a challenging issue in petrochemical industry by combining or integrating sealed radioactive source techniques and radiotracer techniques. The results correspond respectively to tests using two radioisotopes with gamma scanning technique and radiotracers. In the first approach the structural characteristics of a laboratory constructed distillation column have been investigated by using the Gamma scanning technique which consists in using a 60Co as a gamma ray sealed source associated to a NaI(Tl) detector. The second approach by radiotracers consists of an injection of an appropriate quantity of a specific radiotracer (99mTc) at the inlet of the process and studying its presence in the column. Results shows that the radiotracer method may be a good approach for detecting the presence of coke in case of liquid flow through solid packing in distillation columns. Further, data will be useful in numerical modelling and validation by CFD simulations.
        Speaker: Ms Khadija EL KORCHI (National Center of Energy Sciences and Nuclear Techniques (CNESTEN), Morocco)
      • 230
        Measurement of Residence Time Distribution of Wastewater in a Constructed Wetland System Using Radiotracer Technique
        **1. Background of the study:** Constructed Wetlands (CW) are human engineered systems that utilize natural process for treatment of wastewater. They have been highly applicable in developing countries, due to their characteristics like utilization of natural processes, simple construction, operation and maintenance, process stability, and cost effectiveness. The design of constructed wetland requires multidisciplinary inputs involving biological and ecological sciences, aquatic chemistry, engineering hydrology and flow hydrodynamics. The CW are heterogeneous in nature. Thus, they are prone to show deviation in the designed flow pattern and residence time for the treatment of wastewater. Thus, the aim of the present study is to measure mean residence time (MRT) and flow patterns of CWs using radiotracer technique. **2. Methodology employed:** The wetland is 13.0 m long, 3.0 m wide and 0.7 m deep. The geometric volume of the system is 27.3 cubic meter. The system walls and bottom were lined to prevent leakage. The wetland has slope of 1% at the bottom and an average porosity of 52%. About 100 MBq of of Tc-99m (Half Life: 6.6 h, Gamma Energy: 139 KeV) as sodium pertechnatate used in each run. The radiotracer concentration monitored at different planes across the width and outlet using NaI(Tl) scintillation detectors were connected to a computer controlled data acquisition system (DAS) was set to record tracer concentration at an interval of every one minute at outlet and across the bed of the system. **3. Data analysis and Results** The RTD data was treated and analyzed using a RTD analysis software. The data treatment includes background subtraction, tail correction, radioactive decay correction, zero shifting, smoothing and normalization. The data was used to calculate MRT, dead volume of system and hydraulic efficiency of the plant. A four-parameter model i.e. tank in series exchanging with dead volume model prefixed with plug flow component was used to simulate the RTD data. **4. Conclusions** Radiotracer experiments were successfully conducted in an artificially constructed wetland system and mean residence times and dead volumes were determined at different operating conditions. No bypassing/short-circuiting was observed in the CW. The proposed four parameter model was found suitable to describe hydrodynamics of wastewater in the wetland. The hydrodynamic parameters were indicating that CW works efficiently at bed height=0.6m, wastewater flow rate=2.3 cubic meter per second and two point distributor geometry. However, the results of the study also indicate that on increasing the no of injection points, the efficiency of the CW will increase.
        Speaker: Mr Sunil Goswami (Isotope Production and Applications Division, Bhabha Atomic Research Centre, Mumbai 400085, India)
      • 231
        Radiotracer Investigation Of The Effect Of Impeller Type On Mixing In Industrial Process Simulator
        Radiotracer Investigation Of The Effect Of Impeller Type On Mixing In Industrial Process Simulator S.Y. Adzaklo,* C.P.K. Dagadu, I.I. Mumuni, P.S. Adu, H.A. Affum, G.K. Appiah, A. Coleman National Nuclear Research Institute, Ghana Atomic Energy Commission, P. O. Box LG 80, Legon-Accra *s.yadzaklo@gaecgh.org Abstract Radiotracer technology has been applied in the industry for the investigation of process performance, online monitoring of conditions of process plants, troubleshooting and diagnosing anomalies including mixing conditions in continuous stirred tank reactors. In this study, radiotracer methodology was used to carry out investigation on a laboratory water flow rig which serves as simulator of industrial processes. The aims of the investigation were to assess: i) the effect of impeller type on mixing, and ii) the fluid dynamics of the water in the vessels since both the vessels and the impellers were redesigned and reconstructed. Four similar vessels in series circuit with different impeller configurations were investigated. Tank 1 has 1 axial impeller, tank 2 has 2 axial impellers, tank 3 has 2 radial impellers and tank 4 has no impeller. The data was collected by introducing $8$ mCi liquid $^{99m}$Tc at the inlet stream of the vessels and the $\gamma$-signal was collected with thallium activated NaI detector placed at the outlet of the vessels. Residence time distribution (RTD) curves for the outlet tracer concentration were generated from which the mean residence time (MRT) and variance were calculated by the method of moments. The extent of material mixing in the vessels was inferred from the variances and the fluid dynamics was obtained by modelling. The extent of mixing was highest in tank 3 followed by tank 1, and tank 4 gave the poorest mixing. The outlet response curves were fitted with mathematical models using DTS pro and RTD Software. The best fit for tanks 2, 3 and 4 was perfect mixers in series with exchange (PMSE) model while perfect mixers in series with recycle (PMSR) model best described the fluid dynamics of the material in tank 1.
        Speaker: Mr Ishmael Mumuni (Ghana Atomic Energy Commission, Ghana)
      • 12:45
        Discussion
    • 13:15
      Lunch break
    • B13: Radiotracer for managing of natural resources, energy and processes Conference Room M2

      Conference Room M2

      Conveners: Mr Jefferson Vianna Bandeira (Centre for Development of Nuclear Technology (CDTN) - Brazilian Nuclear Energy Commission (CNEN)), TSec Patrick Brisset
      • 232
        Investigation of Heavy Metal Release at a Municiapal Solid Waste Incineration Facolity – an Excellent Example for the Unique Potential of Intrinsic Radiotracer Aapplication to the Investigation of Industrial Processes in Chemical Engineering
        Radiotracers are widespread in use for investigation of material transport processes in industry and environment. Often they are used for the measurement of the residence time distribution in continuously operating chemical engineering facilities and reactors. Mostly intrinsic or physical tracers are used for these purposes. In case of phase transformation processes are in the focus of interest physical or extrinsic tracers are not the labelling material of choice. Intrinsic or chemical tracers are required in that case. At example of the heavy metal release investigation at a municipal solid waste incineration facility the unique potential of intrinsic radiotracers will be demonstrated in the given paper. Goal of the investigation at the municipal solid waste incineration facility reported in this paper was the behaviour study of different heavy metal species at various incineration conditions. With the help of short lived radioisotopes of copper (Cu-64) and zinc (Zn-69m) could be shown at which position of the incinerator and in which amount the heavy metal under investigation was released. The experimental results of this investigation were an essential contribution for better understanding the processes inside the incinerator and to optimize the processing conditions.
        Speaker: Mr Thorsten Bruno Otto Jentsch (Helmholtz-Zentrum Dresden-Rossendorf e.V., Germany)
      • 233
        Radiotracer Investigation in an Aeration Tank of a Waste Water Treatment Plant
        A radiotracer experiment was conducted in an aeration tank of a waste water treatment plant in a chemical plant in Malaysia. Idoine-131 (half-life: 8 days, energy: 360 keV (80%), 640 keV (9%)) as sodium iodide was selected to be used as a radiotracer. About 12.5 GBq (200 mCi) activity of radiotracer was used. The radiotracer was diluted in a volume of about 30 liter and injected into the splitter pit at a constant rate for a period of about 10 minutes using a specially fabricated injection arragnment. This ensures good mixing of the tracer with the inlet stream of wastewater and almost equal division of radiotracer into two individual tanks (tank A and tank B). The period of injection is negligibly small as compared to expected mean residence time of the wastewater in the tank and hence the tracer injection can be considered as an impulse or instantaneous injection. The radiotracer was monitored at different strategically selected locations using 11 waterproof scintillation detectors (2 inch x 2 inch). All the detectors were connected to a common 12-channel computer controlled data acquisition system programmed to monitor tracer concentration data at an equal time intervals. During the acquisition, the data was saved at regular intervals. The continuous on-line monitoring of tracer was conducted for a period of 26 days. Results revealed that no malfunctioning such as bypassing or short-circuiting of the flow was observed in the tank. The mean residence time in the tank was estimated to be about 6 days, which matches with the theoretical mean residence time (hydraulic retention time). The residence time in the membrane was negligible as compared to the residence time in the tank. No considerable dead volume was found in the tank(s). This indicated that the entire volume of the aeration tank was used for the treatment of the wastewater. A model with a tank connected to a dispersed plug flow component in series with a recycle flow was found suitable to describe the flow of wastewater. The results of the model simulation showed that the aeration tank (s) behave as an ideal mixer. However, the membrane behaved as a plug flow reactor. The result of simulation indicated that the recycle flow rate is about 1.4 times of the inlet flow. The results of the investigation will help the plant engineer to evaluate the performance of the aeration tank.
        Speaker: Mr Jaafar ABDULLAH (Malaysian Nuclear Agency (Nuclear Malaysia), Malaysia)
      • 234
        Data Fusion Approach for Improving the Reliability of Radiographic Testing and other Complementary NDT Techniques
        Non-negligible uncertainty and imprecision in defect detection and defect sizing exist when only using one single Non Destructive Testing (NDT) technique. To increase the reliability and reduce the uncertainty of defect detection and defect sizing, the complementarity and redundancy of radiographic and ultrasonic testing data is exploited. The reliable concept to improve the detection and characterization of defects is by combining the data sets of these NDT techniques. This goal is achieved by employing mathematical Data Fusion techniques [1][2]. These are techniques allowing for simultaneously taking into account heterogeneous data coming from different sources in order to get an optimal estimation and evaluation of defects under investigation. The present study focuses on the development of a data fusion approach based on the evidence theory (Dempster-Shafer theory) [3][4] in order to merge a large number of data sets, in a suitable manner, and obtain more reliable results of localization and characterization of defects inside a component. The proposed method is validated by a real ultrasonic and radiographic NDT data of different industrial components. References: [1] D.L. Hall, Mathematical Techniques in Multisensor Data Fusion, MA: Artech House, 1992. [2] X.E. Gros, NDT Data fusion, John Wiley and Sons, New York, 1997. [3] A.Shafer, Mathematical Theory of Evidence, Princeton University Press, Princeton, NJ, USA, 1976. [4] A.Dempster, Upper and lower probabilities induces by multi-valued mapping, Annals of Mathematical Statistics, AMS-38, 1967.
        Speaker: Mr Rachad Alami (National Center of Energy Science and Nuclear Techniques, Morocco)
      • 235
        Neutron Backscatter Technique as an Alternative Method for Quality Assurance and Standardization of Petroleum Products
        Crude cost is one of the most important parameters in the operation of an oil company. The choice of crude is very vital in that it determines the profit margins of oil companies, hence the selection of an optimum crude for processing requires a lot of consideration. Neutron backscatter technique is a non-destructive method used for industrial investigation, including determination of hydrogen content of crude and its finished product. This method has a wide scope of application and is faster in comparison with the chemical methods employed by the petroleum industries which are destructive, product specific and often requires several hours of heating samples at temperatures up to 75 0℃ to obtain results. Neutron backscatter technique was used in this work to determine the total hydrogen contents of petroleum samples from Tema Oil Refinery (TOR) and crude oil samples from the Jubilee oil field in Ghana and Bonny light and Forcados oil fields in Nigeria. Excess neutron counts were measured and reflection parameters determined as a function of hydrogen content of the samples. Liquid hydrocarbons of known hydrogen and carbon contents were used as standards to draw calibration curves against which the total hydrogen contents of the samples were determined. The total hydrogen contents were found to be in the range of 7.21(hw %) - 15.06 (hw %) for vertical geometry and 7.20 (hw %) - 14.94 (hw %) for horizontal geometry respectively. The results obtained agreed well with other results obtained using different methodologies. The results shows a high hydrogen content in both Nigeria's bonny light and Ghana's Jubilee crude oil samples however, in Nigeria's Forcados crude oil sample there was a low hydrogen content. This confirms that neutron backscatter technique is able to distinguish between light sweet crude and heavy sour crude.
        Speaker: Mr Ishmael Iddisah Mumuni (Ghana Atomic Energy Commission, Ghana)
      • 236
        Identification of the Internal Condition of Crude Oil Distillation Unit Using Gamma Column Scanning Technique in Myanmar
        Gamma Column scanning technique was utilized to identify of mechanical problems such as missing, collapsed or buckled trays in trayed column of Crude Oil Distillation Unit C at the No. (1) Refinery (Thanlyin), Yangon, Myanmar. It has 52 trays, diameter is 2 meter and height is 43.55 meter. Scanning type of work is Blank Scan and this unit has been shutdown since 2010 due to some processing problem. Refinery wanted to know internal condition of a column before operation. The scanning work was performed using 50 mCi 60Co gamma source, NaI (Tl) scintillation detector, manipulation system (winchers) and ColScanCK1 Data Acquisition (DAQ) system with NibraS software to investigate condition of all trays. Refer to the mechanical drawing of the tower, the point at elevation of 7350 mm was assigned as starting point of the scan and it was notified as 0 mm. Three scan lines were selected; one for single pass trays and two for double pass trays within the left and right down comer areas of Distillation Unit. Radiation source was placed at 44 degree, 59 degree and 107 degree and detector was placed at 224 degree, 291 degree and 224 degree in respectively. It was challenged to scan because the space between insulator and ladder is very narrow, in some places detector and source were passed the ladder with considering of radiation safety aspect. Although size of tray # 1 to 8 are very small and wall of column is very thick in these place, we could determine tray # 1 to # 8 were in their positions. From identification, all scan profiles interpreted that tray # 1 to # 52 were normal and in their positions.
        Speaker: Ms Moe Phyu Hlaing (Department of Atomic Energy, Myanmar)
      • 15:55
        Discussion
    • P-A2: Radiation Creation of Materials from Fundamentals to Application IAEA Board Room B/M1

      IAEA Board Room B/M1

      IAEA Headquarters

      Poster Session on Radiation Creation of Materials from Fundamentals to Application. Authors will present.

      Conveners: Mr Laszlo Wojnarovits (Centre for Energy Research, MTA), TSec Agnes Safrany
      • 237
        A Comparative Study of Radiation Sterilization of Cell Culture Media and Filtration Sterilization Method in Cell Culture Laboratory
        Cell culture media is uses in biopharmaceutical processes to stimulate the natural environment of the cell. Media used in cell culture have a balanced salt solution; the most commonly used is sodium bicarbonate with a pH of $7.2$–$7.4$ at $37^\circ$C that the optimal growth of cells. Filtration is a safe method used for media sterilization in cell culture laboratory; it helps to removes the microorganisms, but is unable to separate microorganisms that have the same size. The most common types used in tissue culture has a pore size $0.2~\mu$m. The aim of this study is using $\gamma$-radiation to sterilize media in cell culture laboratory compared to filtration sterilization method. For media preparation, RPMI-1640 media in powder form, containing vitamins, minerals, amino acids and red phenol, was added to NaHCO$_3$ and dissolved in distilled water, and a pH meter was used for pH determination. A $^{60}$Co $\gamma$-irradiator was used for dose irradiation of $5$ kGy and $20$ kGy at $1.26$ kGy/h dose rate. The irradiation was carried out at the Chemistry and Physics Institute of the Sudan Atomic Energy Commission. Testing of bacteria included total viable aerobic count and total coliform count. Cell viability testing was made by adding $0.5$ m$\ell$ of lymphocytes to $4.5$ m$\ell$ from RPMI media, $1.2\%$ penicillin/streptomycin, $1\%$ fetal bovine serum, $30~\mu$m$\ell$ Phytohaemagglutinin glutamine, and then incubated for $24$ hours in CO$_2$ incubator. Cells were then counted using jumper. A $\gamma$-radiation dose of about $20$ kGy was found to be enough to destroy most type of bacteria rather than $5.0$ kGy, but not suitable for sterile media cell culture in laboratory because increasing the probability of poor cell growth. While a dose of $5$ kGy does not completely sterilize the media and cell growth observed. Physiology of media environment is summarized as follows for Lymphocytes growth and pH control for $\gamma$ radiation dose and filtration for sample media: | ---------------| ------------| -------------| ----------| -----------| ------------| | Media | Cell Death | Cell Growth | pH (pre) | pH (post) | Media | | Sterilization | (24 Hours) | (48 hours) | | | Colour | | $5$ kGy | $50\%$ | $50\%$ | $7.2$ | $7.2$ | change | | $20$ kGy | $70\%$ | $10\%$ | $7.2$ | $8.0$ | colourless | | Filtration | $10\%$ | $>60\%$ | $7.2$ | $7.3$ | no change | | ---------------| ------------| -------------| ----------| -----------| ------------| Media can be sterilized by $\gamma$-radiation with doses larger than $5$ kGy, but red phenol that indicator pH of media was degraded with increases the $\gamma$-dose. This result suggests that $\gamma$-doses larger than $5$ kGy and less than $20$ kGy should be tested to achieve the dose range accepted for cell culture media sterilization without affecting cell integrity. Then, radiation sterilization among RPMI media may useful for liquid RPMI media without red phenol, used in stem cell. Further research on red phenol degradation by $\gamma$-radiation, and amino acids concentrations post-$\gamma$ irradiation is strongly recommended, and might help in sterilization and modifications of media for various cell culture applications using $\gamma$-rays.
        Speaker: Ms Alkhansa Mahmoud (Sudan Atomic Energy Commission, Sudan)
      • 238
        Application of Gamma Radiation and Physicochemical Treatment to Improve the Bioactive Properties of Chitosan Extracted from Shrimp Shell
        **Abstract** The aim of this study is to improve the different bioactive properties of chitosan extracted from chitin by different physicochemical treatments including gamma radiation. Chitin was prepared from shrimp shell upon deproteination, decalcification and oxidation with 4% NaOH, 4% HCl, and 2% H2O2 respectively. To find out a more efficient, economically reasonable and time saving chitosan extraction method other than existing methods, eight different physicochemical treatment methods (designated as A, B, C, D, E, F, G and H) varying different parameters were applied for chitosan extraction. Chitosan produced by these extraction methods were compared with commercially available chitosan and assessed with respect to degree of deacetylation (DD-value), molecular weight, antimicrobial activity and solubility. DD-value of chitosan extracted by method A, B, C, D, E, F, G and H were 75.0±0.28%, 92.0±0.34%, 81.0±0.51%, 89.0±1.34%, 69.0±0.05%, 87.0±0.35%, 82.0±1.4% and 92.0±0.92% respectively whereas the DD-value of the commercially available product was ~75.0%. Viscosity-average-molecular-weights were found 1.77×105±0.28, 1.6×105±0.50, 1.82×105±0.46, 1.19×105±0.39, 2.25×105±0.39, 1.41×105±0.67, 1.77×105±0.28 and 1.16×105±0.69 Dalton respectively. Antimicrobial activity of all chitosan samples was found insignificant and all the samples could be dissolved completely at minimum 0.5% of acetic acid solution. For further quality improvement, chitosan with highest DD value (prepared by method B) was irradiated with different doses (5.0, 10.0, 15.0 and 20.0 kGy) of gamma radiation and again assessed for different quality parameters. Though no significant changes in DD value of chitosan was observed upon irradiation, it causes significant changes in the molecular weight of chitosan samples. Molecular weight gradually decreased as the radiation dose increased. Molecular weight of the samples treated with the radiation doses of 5.0, 10.0, 15.0 and 20.0 kGy were 1.786×103, 1.518×103, 1.134×103 and 1.046×103 Dalton respectively. Radiation treatment of chitosan samples also increased the antimicrobial activity in concentration dependent manner. One and half (1.5%) percent chitosan solution treated with a radiation dose of ~10.0 kGy showed highest antimicrobial activity. Repeated alkali treatment (20 M NaOH) and autoclave for 30 minutes was found to be the best extraction method and irradiation of chitosan solution with 5.0 to 10.0 kGy further increased its bioactive characteristics including enhanced antimicrobial and solubility properties.
        Speaker: Mr Md. Kamruzzaman Pramanik (Microbiology and Industrial Irradiation Division,Institute of Food and Radiation Biology, Atomic Energy Research Establishment, Bangladesh Atomic Energy Commission, Bangladesh)
      • 239
        Biopolymer-Silver Nanoparticle as a CIELAB Colour Space Dosimeter
        A new purpose of silver nanoparticles (AgNPs) in chitosan (CS) biopolymer is proposed as a radiation dosimeter for application in the dose range of food irradiation. The biopolymer-AgNPs are simply prepared from AgNO$_{3}$ precursor and CS (DD ${=} 90$%, $M_v = 580$ kDa) aqueous solution. The optimum formula of biopolymer-AgNPs dosimeter was studied. A series of the prepared biopolymer-AgNPs dosimeter relatively response by colour changing to the electron beam irradiation doses. With this system, the colours were measured in a CIELAB colour space using a colourimeter. The biopolymer-AgNPs dosimeter is exposed to various irradiation doses ranging from $0$ to $10$ kGy. Based on CIELAB colour space, the colour of biopolymer-AgNPs dosimeter is changed from white to yellow and dark brown by irradiation. The numerically measured colour is presented in the CIELAB colour difference ($\Delta$E$_{ab}$). The relationship of dose and colour showed that $\Delta$E$_{ab}$ linearly increased with irradiation dose. The colour change is due to the particle size of biopolymer-AgNPs dosimeter. The colours from the developed biopolymer-AgNPs dosimeter can be applied using general purpose scanner and the measured colours were then calculated to their corresponding radiation doses. The biopolymer-AgNPs dosimeter is expected to be a simple, economical, effective and alternative device as the food irradiation dosimeter.
        Speaker: Mr Thananchai Piroonpan (Department of Imaging and Printing Technology, Faculty of Science, Chulalongkorn University)
      • 240
        Chemical Reduction of Nitrate by Zerovalent Iron Nanoparicles Adsorbed Radiation Grafted Copolymer Matrix
        Nitrate contamination of global water resources due to the globalization of modern agricultural practices is an emerging threat worldwide. In spite of the usefulness of nitrate and nitrogenous compounds as essential elements in life processes, nitrate is potentially hazardous when present in drinking water at sufficiently high concentrations. Due to its high solubility nitrate may actually be the most widespread and priority contaminant in drinking water. It acts as a precursor for several health hazards ranging from blue baby syndrome to gastric cancer. Treatment of nitrate containing water is challenging due to its stability. The reduction is the only possible way to fully remove nitrate contamination from ground water as it does neither form insoluble minerals that could be removed as precipitates nor does it significantly adsorb under aquifer conditions. The nitrate molecule is a good electron acceptor and hence an efficient electron donor is required for its reduction. nZVI can play a major role in this situation as it is a good electron donor with a high reactivity due to its extremely small size and strong reduction capacity. The results obtained in this work suggest that metallic-Fe can support chemical reduction of nitrate contaminated water. This research specifically focused on development of novel methodologies to reduce excess nitrate in drinking water utilizing nZVI stabilized radiation grafted copolymer matrix. nZVI was synthesized by borohydrate reduction of FeCl3 and stabilized on a radiation grafted copolymer matrix. Acrylic acid (AAc) grafted non-woven polyethylene/polypropylene (NWPE/PP-g-AAc) fabric was used as the supportive copolymer matrix and Co-60 gamma radiation was applied. In previous research, this material has been extensively characterized. The chemical reduction of nitrate by nZVI adsorbed NWPE/PP-g-AAc (nZVI-Ads-NWP) fabric was examined in batch experiments at different pH values with the aim of optimizing ammonia production (ammonia being the major end product) for subsequent conversion to chloroamines upon chlorination. The pH of the solution showed a marked effect on nitrate reduction with enhanced efficiency in acidic conditions compared to the micro-scale iron particles. After about 24 h, at pH 3, almost 96% of nitrate was degraded. According to characterization data for the material, the surface of the nZVI due to the core-shell structure contains ferrous hydroxide and other protective layers. At low pH values, these protective layers can be readily dissolved exposing the pure iron particles for efficient chemical reduction of nitrate. Experimental results suggest that this reduction process is an acid-driven surface mediated process. The nZVI water interface has been fully characterized by the 1-pK Basic Stern Layer Model (BSM) and an Eley-Rideal like mechanism well described the nitrate reduction kinetics. In accordance with green technology, newly synthesized nZVI-Ads-NWP has great potential in designing a nitrate reduction process required in drinking water industry.
        Speaker: Ms Sanduni Ratnayake (Sri Lanka Atomic Energy Board, Colombo, Sri Lanka)
      • 241
        Correlation of Traditional and One-Step Irradiation Process for Chitosan Production from Charybdis Hellerii Crab Shell’s
        Chitosan is a polysaccharide obtained from chitin’s molecule deacetylation, which is the main composition of certain fungi species and crustaceans and insects exoskeleton. The amino groups present in chitosan give it important biological properties such as biodegradability and biocompatibility, activity/immunological effects and antibacterial healing. The deacetylation of chitin is an aggressive process, which reaction processes in 6 to 8 hours under hot concentrated alkali solution. In this work, Charybdis hellerii crab shell’s was fragmented and pre-treated for chitosan production and each conversion step, from in natura material pre-treatment to final chitosan, were investigated in deteails. It was observed dose and dose rate applied as in natura as pre-treated chitin have not influence neither pre-treatment process nor chitin deacetylation step; at 20 kGy (from gamma or electron beam sources), the conversion process was performed in 60 minutes. The obtained chitosan presented low weight and deacetylation degree compared to standard chitosan, considering specific irradiation conditions.
        Speaker: Ms Maiara Salla Ferreira (Instituto de Pesquisas Energéticas e Nucleares, IPEN - CNEN/SP, Brazil)
      • 242
        Decoloration and Degradation of Erythrosine by Gamma Irradiation
        In this study, the decoloration and mineralisation of aqueous solution of the erythrosine dye irradiated under gamma rays from 60Co are investigated. From the results of absorption UV visible spectra erythrosine solution as function of dose, the concentration of erythrosoine decrease exponentially with increasing the gamma irradiation dose and the plot on a logarithmic scale against the dose shows a clear pseudo first order rate. The apparent pseudo first order constant was calculated .The change in decoloration percentage removal of chemical oxygen demand (COD) and total organic carbon (TOC) were investigated with respect to the applied dose influences of absorbed doses. Complete mineralization of erythrosine dye was achieved with gamma irradiation.
        Speaker: Ms Amira ZAOUAK (National Centre for Nuclear Science and Technology, Tunisia)
      • 243
        Determination of the Radiation Dose Required to Obtain Desired Viscosity Average Molecular Mass Using Commercially Avaible Chitosan and Signification of this Technique in its Applications
        Radiation processed chitosan polymers are used in many applications in the field of Agriculture such as plant growth promoters, elicitors, fungicides and self-life extending coatings for fruits etc. Radiation or chemical degradation techniques or a combination of both methods can be used to convert higher molecular masses of chitosan to its different low molecular masses. The applicability of the chitosan in the above applications highly depends on the molecular weight of chitosan. However viscosity average molecular masses of commercially available chitosan (CAC) show huge variations and these variations arise due to the use of different techniques in the extraction process. This variation of the molecular masses of the CAC makes it difficult to determine the correct radiation dose to obtain the desired molecular weight. The main objective of this study is to construct a correlation between the variation of viscosity average molecular mass of CAC samples vs. irradiated doses. The above correlation enables the determination of the radiation dose required to get the desired molecular weight from a known initial molecular weight. The viscosity average molecular mass is the key factor of the performance of the products developed using chitosan. CAC samples with similar degree of deacetylation (DDA) and various molecular masses were irradiated at different radiation doses using GC-5000 Gamma Cell under 3.4 kGy/h dose rate. The viscosity average molecular mass of these irradiated samples were analyzed using Capillary Viscometric method. AVS 470 Visco system with a standard solvent system (0.25 M CH3COOH/ 0.25 M CH3COONa at 25oC) and Mark-Houwink-Sakurada equation were used for the determination of viscosity average molar masses. The relationship between the varying viscosity average molar masses vs. absorbed dose was constructed using regression analysis and desired molecular weight was obtained using this relationship. Oligo chitosan with selected molecular masses are used in the production of some agro-products and the above technique can be used as an initial step of the production of oligo chitosan with required molecular weight using CAC. Oligo chitosan can be produced using a combination of chemical and Gamma irradiation techniques (synergic technique) in aqueous media. However, a standard procedure cannot be followed in the production of oligo chitosan due to the dissimilarities of the molecular masses of CAC. Therefore, a fixed initial molecular weight (compatible with existing standard procedure) should be produced using CAC in order to follow a standard procedure based on the synergic technique. The regression curve developed under this study was used to find out the required dose to produce fixed molecular weight using CAC. Therefore the procedure developed through the above study can be utilized to derive the fixed low molecular weight chitosan to follow the standard procedures used in pilot and commercial scale productions of Agro products which are based on Oligomer/Low molecular weight chitosan.
        Speaker: Mr Kumarawadu Ruwan Chandima De Silva (Sri Lanka Atomic Energy Board, Colombo, Sri Lanka)
      • 244
        Developing a Simple Method Using Ionizing Radiation to Produce Polyacrylic Acid Based Nanoparticles
        The present work aims at synthesizing polyacrylic acid-based nano- particles using ionizing radiation without surfactants. In this regard, acrylic acid in a solution in the presence of poly aliphatic ester polymers like polycaprolactone and polylactic acid was exposed to ionizing radiation at different dose rates to produce chemically crosslinke poly aliphatic ester /PAAc nanoparticles. Particle size and swellability of the prepared nanoparticles can be controlled by irradiation dose, irradiation atmosphere, and feed copolymer composition and concentration. Characterization of the prepared nanoparticles including morphological structure, pH sensitivity and rheological characteristics was carried out using dynamic light scattering (DLS), viscometry, transmission electron microscopy (TEM) and atomic force microscopy (AFM) techniques
        Speaker: Mr Hassan Abdelrehim (Atomic Energy Authority of Egypt, Egypt)
      • 245
        Development of Advanced Scaffolds and Polymeric Systems for Improved Cell and Tissue Growth
        The recent concern related to skin compromised patients, apart from the nature of the condition itself, such as wounds, chronic ulcers, or burns among others, has triggered and highlighted the importance of the development of artificial skins available in allogeneic donor tissue banks and/or scaffolds, composed by a wide variety of biocompatible, biodegradable and bioactive biomaterials. Within this context, tissue engineering has been in expansion as an attempt overcome difficulties faced in such situations. The application of scaffolds, produced or not by nanotechnology, in the skin of a patient induces cells to proliferate and get organized on extracellular matrix regenerating tissue. Ionizing radiation is a particularly useful technology capable of promoting sterilization and crosslinking of the scaffolds structure thus offering several possibilities for the development of advanced systems suitable for cell growth.Taking into account the variety of clinical applications of tissue engineering, the aim of this study was to investigate by means of histological tests, chemistries and non-destructive tests, the interaction of mesenchymal stem cells grownin vitro in conjunction with different frameworks in order to understand how the mesenchymal stem cells behave in different niches. Among those collagen, PVA, chitosan, PDLLA scaffolds were the systems of choice and gamma irradiation was applied for sterilization of the systems, as well as crosslinking for the PVA based scaffold. Thus this work allowed the achievement of dermo-epidermic matrices populated by epidermal cells that make up the skin and will contribute to the development of a more robust and useful material to be used in several treatments.
        Speaker: Mr Gustavo Henrique Costa Varca (Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, Brazil)
      • 246
        Development of Nanocomposite Coatings by Radiation Curing
        Kencana Fibercomposite is a manufacturer producing high performance fiber composite derived from a revolutionary green technology. These composites are alternative to wood and used in building construction. At present, these materials are ready to be used without coating or painting, however they are vulnerable to scratch and abrasion during handling and transportation. Therefore, Kencana Fibercomposite and Nuclear Malaysia have collaborated to develop scratch and abrasion resistant nanocomposite coating materials. The most appropriate process to cure the materials is using radiation curing technology. The technology offers several advantages such as fast curing, improved productivity and product performance, curing at room temperature and elimination of volatile organic compound (VOC). In this research work, the incorporation of silica nanoparticles into radiation curable resins is to enhance scratch and abrasion properties of the coating materials while retaining transparency and glossiness. Radiation curable nanomaterials can be prepared using heterogeneous hydrolytic condensation technique. Composite materials that exhibit a change in structure and composition over nanometer length scale have been proven in imparting remarkable property enhancement with respect to stiffness and strength. The technique is also capable of overcoming several major issues related to compatibility between the matrix and the nanoscale component, and also agglomeration of nanosized component during processing. This will produce a homogeneous distribution of nanosilica in the radiation curable nanomaterials. Silico-organic nanoparticles have relatively large surface areas compared to microparticles, therefore modification effects from the polymerization activity should have a great influence on the properties of the composites. During curing process, electron beam (EB) radiation and ultraviolet (UV) light were used to initiate radical polymerization. These polymerization active nanoparticles were obtained from heterogeneous hydrolytic condensation of the silane to the silanol groups of the silica particles. The above reaction could be verified by the application of FT-Raman spectroscopy (intensity measurement of the C=C vibration band at 1640 cm-1) and gel permeation chromatography to show the impact of polymerization activity of the nanoparticles on the silico/acrylate dispersion. In the curing process, the nanoparticles form crosslinkages to produce radiation cured polymeric composite with improved scratch and abrasion resistance. From Taber abrasion, it can be observed that the weight losses of radiation cured materials are significantly reduced when the amount of silica particles (SiO2) increases. The nanoparticles added into the coating materials significantly improved the scratch property. Finally, it can be concluded that polymerization active silico-organic nanoparticles could be prepared by in situ reaction. Formulations useful for technical coating process could be prepared and cured using the low energy electron beam (EB) and ultraviolet (UV) light. The composite materials showed highly improved mechanical properties. These polymeric nanocomposites show excellent resistances toward abrasion and scratch properties when compared to pure materials without nanoparticles.
        Speaker: Mr Nik Ghazali Nik Salleh (Malaysian Nuclear Agency, Malaysia)
      • 247
        Distinct Polymeric Based Materials Prepared/Functionalized by Gamma Irradiation for Biomedical Applications and Roman Mosaics Preservation
        Polymeric based materials are being successfully prepared/modified or functionalized by ionizing radiation processing techniques targeting an increasing number of specific applications in different areas. We have been particularly focused in two reactional systems: 1) Chitosan based copolymeric biocompatible and biodegradable matrices to be used as skin scaffolds for tissue regeneration processes and, 2) PDMS-Silica ormosils (organically modified silicates) hybrid materials for medical applications (bioactive component for bone substitution/reparation /consolidation for orthopedic and dental surgeries) and for the consolidation of ancient Roman mosaics (additive with biocide activity for the composite materials used in ancient mosaics panels conservation processes). Regarding chitosan based copolymeric biocompatible and biodegradable matrices, a methodology involving freeze-dry of (co)polymeric solutions followed by gamma irradiation from a Co-60 source was tested. In order to compare the performance of matrices concerning cell-matrices interaction, the effect of matrices content in poly(vinyl alcohol) and gelatin was evaluated in terms of matrices’ structural properties and cellular viability. Results evidence that for the same radiation dose matrices’ composition can be used to tailor the matrices’ surface in terms of porosity/roughness. Moreover, in vitro tests revealed that cells adhered and proliferated in all irradiated matrices. Concerning the preparation of hybrid materials by gamma irradiation we have been investigating the system PDMS-TEOS-PrZr (polydimethylsiloxane, tetraethylorthosilicate and zirconium propoxide, respectively) in different conditions. Materials are prepared by direct energy deposition on a mixture of PDMS silanol terminated (33 wt% fixed content), TEOS and a minor content of PrZr that varied from 1 to 5 wt%, in a closed system under nitrogen atmosphere, using gamma radiation from a Co-60 source. The samples, dried in air at room temperature, are bulk, flexible, transparent and nanostructured. Depending on the polymer Mw and on the amount of PrZr it is possible to tailor the size and distribution of the oxide regions as so the hybrid porosity. Results obtained evidence, although relatively low, their natural bioactivity and biocide activity. The introduction of new components in the hybrid formulation to improve these properties seems to be effective, without compromising their natural affinity and compatibility with the materials to which they are intended to “work together”. Preliminary results shows good perspectives for their intended use.
        Speaker: Mr Luis M. Ferreira (Centro de Ciências e Tecnologias Nucleares (C2TN), Instituto Superior Técnico, Universidade de Lisboa, Portugal)
      • 248
        Dyestuff Free: Coloring Fabrics by Graft Polymerization
        Laundering durable functional fabrics are obtained by means of radiation-induced graft polymerization methods, via the graft polymerization of functional monomers or co-graft polymerization of the monomers and certain nanoparticles[1-4]. The laundering durability lies in the formation of the covalent bonds between the cellulous macromolecules and the graft chains or together with the nanoparticles, which is the most advantage of the radiation methods in fabric modification. Dyestuffs, normally referring to the organic molecules which can be dissolved or dispersed in solutions, are used to coloring cotton fabrics since they can be absorbed by the nanoporous structure and the non-crystalline zone, or even the lamella of the crystalline zone of the fabrics. Reactive dyestuffs can react with the hydroxyl groups on the cellulous macromolecules under high temperature and basic conditions. Although dyestuffs are well-developed chemical products and the dying process is mature too, the long treating period and high pollution of the waste water are need to be solved. In our previous study, we found that radiation-induced graft polymerization methods will be a dyestuff-free way to color the cotton fabrics by co-graft polymerization the colorful nanoparticles. For example[5], MIL-101, a typical metal organic framework (MOF) which comprises a nontoxic chromium(III) cluster and benzene-1,4-dicarboxylate ligand, was co-graſt polymerized onto nylon fabric with 2-hydroxyethyl acrylate (HEA), owing to the abundance of benzene rings in MIL-101 which is favor for free radicals generation on its surface. The color of MIL-101 is dark green, and the color of the grafted nylon fabrics is green and darkens with the increasing degree of grafting of MIL-101. More important, the robustness of the product was demonstrated by 30 hours dry-cleaning test using tetrachloroethylene as the organic solvent, and most of the MIL-101 particles still adhered to the nylon fabric after the washing. Base on the above facts, we are now developing the dyestuff-free coloring fabric procedure by fixing pigments micro- or nanoparticles onto the cotton fabric under radiation-induced co-graft polymerization methods. References: (1) Deng, B.; et al.; Adv. Mater. 2010, 22, 5473−5477. (2) Wu, J. X.; et al.; Sci. Rep. 2013, 3, 2951. (3) Wu, B. T.; et al.; Sci. Rep. 2015, 5, 11255. (4) Yu, M.; et al.; ACS Appl. Mater. Interfaces 2013, 5, 3697−3703. (5) Yu, M.; et al.; Sci. Rep. 2016, 6, 22796.
        Speaker: Mr Jingye Li (Shanghai Institute of Applied Physics, Chinese Academy of Sciences, China)
      • 249
        Effect of $\gamma$-Irradiation on the Molecular Weight and Structure of Guar Gum
        Background ---------- This work was done in order to evaluate the degradation in polysaccharides structure of food additives guar gum processed with $\gamma$-irradiation. The IR absorbance spectra of the material prior to irradiation is a good tool to determine the molecular weight and molecular weight distribution. Material and method: -------------------- Guar gum samples were irradiated in powder and aqueous solution in two concentration ($1$ and $0.5$ g/100 m$\ell$ prepared at room temperature) with different doses ($0$, $2.5$, $5$, $7.5$, $10$, $20$, $30$, $40$ and $50$ kGy) of $^{60}$Co $\gamma$-rays ($0$ held as control sample). The changes of molecular weight and structures of the processed samples were investigated and characterized using Fourier-transform infrared spectra (FTIR), ultraviolet-visible spectral (UV-vis). The results showed the molecular weight decreased gradually with increasing irradiation dose. The infrared spectra of the control and irradiated powder were recorded using Ashemaduze model Fourier transform infrared spectrometer, in the range $4000$–$350$ cm$^{-1}$. The KBr pellet technique was adopted for recording the spectra. The solid samples were obtained through following the procedure of adsorption measurement. Approximately $2$ mg of desired powder sample was thoroughly mixed with $200$ mg of spectroscopic grade KBr and pressed into pellets for recording the spectra. The measurement was carried out by transmittance scans of dilute solutions of $0.5$ and $1\%$ from control, irradiated powder samples and standard (solutions of $1\%$ Glactose, $1\%$ Mannose) and irradiated solutions concentration ($0.5$ and $1\%$) in the wave length range $250$–$600$ nm. Results and dissection: ---------------------- Results by FTIR and UV-Vis spectra showed that the effect of irradiation on guar gum is random. Especially with high doses FTIR spectra indicated that $\gamma$-irradiation introduced no significant changes into the structure and crystal texture, but UV spectra showed an absorption peak at about $265$ nm, increasing with irradiation dose, which was attributed to the formation of carbonyl groups or double bond. Conclusion: ----------- $\gamma$-irradiation effects on guar gum properties (chemical and physical) depend on the state of the gum when irradiated as powder or solution. The effect of the same dose in low concentrations is more than in high concentrations.
        Speaker: Ms Hoiam Sayed (Sudan Atomic Energy Commission, Sudan)
      • 250
        Effect of Gamma Radiation on the Physicao-Mechanical Properties of Gelatin-Based Films and Jute-Reinforced Polymer Composites
        Gelatin, a natural protein, is insoluble in water and is solubilized by hydrolysis. Gelatin based polymeric films were prepared in aqueous medium by casting. The mechanical properties were evaluated by proper method. The tensile strength was found to be 27MPa. Gelatin films were soaked in different formulations containing 2-hydroxyethylmethacrylate (HEMA), methanol and photo-initiator and then irradiated under gamma radiation. Again, a series of gelatin solutions was prepared by blending varying percentages (10–50% by wt) of HEMA and then films were prepared and irradiated under gamma radiation. It was found that tensile properties of gelatin films improved significantly. In another investigation, jute fiber reinforced polypropylene (PP) composites were prepared by compression molding. Composites were fabricated with varying percentages of jute and irradiation dose. Total radiation dose varied from 250-1000 krad and composites made of using 500 krad showed the best results. Key words: 2-Hydroxyethylmethaacrylate; Gamma radiation; Gelatin; Grafting; Polymer matrix composites (PMCs), Surface treatment
        Speaker: Mr Mohammad Zahirul Islam Mollah (Bangladesh Atomic Energy Commission, Bangladesh)
      • 251
        Effect of Spatial Confinement on the Radiolytic Efficiency of High-Energy Ions in Polymers
        In this work, the radiolytic efficiency of MeV-GeV heavy ions in polymer thin films has been quantified, following the induced chemical damage as the layer thickness h of the films is systematically reduced (2
        Speaker: Mr Ricardo PAPALÉO (Pontifical Catholic University of Rio Grande do Sul, Brazil)
      • 252
        Electron Beam Synthesis of Inulin Hydrogels Extracted from Helianthus Tuberosus L.
        Background of the study: Obtaining hydrogels from various classes of natural polymers has undergone significant growth over time especially for applications in the biomedical field. Hydrogels made from natural polymers have the advantage of being biocompatible and biodegradable. In this context, an important role is played by inulin-based hydrogels, which is a natural polysaccharide. In our study we describe a method for extracting inulin from Jerusalem artichoke (Helianthus tuberosus L.) while current methods imply obtaining inulin form the root of chicory (Cichorium intybus). Methodology: Inulin form Jerusalem artichoke was supplied by S.C. Hofigal Export Import S.A. The concentrated inulin extract was obtained after three consecutive extractions in vacuum. The Ar-saturated inulin extract was irradiated with an electron beam at the dose rate of 2-4 kGy/min up to 25 kGy in „paste-like” conditions and in the presence of tannic acid (TA) and glycidyl methacrylate (GMA). Sol-gel analysis was performed in order to determine the polyssachride-gel conversions ratio, the radiochemical yield of crosslinking and degradation. In order to follow the formation of a 3D hydrogel network and its composition, dynamic rheological measurements and FT-IR analysis were performed. The swelling capacity was determined in deionized water and phosphate buffer solution pH=7.4 at 37oC. Results and Conclusion: Gel fraction is dependent on the absorbed dose and on the increasing concentrations of TA and GMA. The value of radiochemical crosslinking yield was larger than degradation yield. The rheological measurements revealed the obtaining of a gel with G’>G”, were the G’ value has decreased with dose. The maximum value of swelling capacity for the inulin hydrogel was found to be around 10 000 %, with smaller values for gels that were swollen in phosphate buffer solution. This gel offers a promising route of administration for various drugs with anti-inflammatory and analgesic properties. This study will be continued by embedding natural extracts obtained from arnica, pepper, aloe vera and Echinacea, in the inulin hydrogel, in order to obtain a product with applicability in treatment of chronic colon disease.
        Speaker: Mr Ion Cosmin CALINA (National Institute of Research & Development for Laser, Plasma and Radiation Physics, Romania)
      • 253
        Evaluation of Thorium Adsorbent Prepared by Radiation Grafting and Functionalization with Glucamine
        Adsorption is considered as the most effective and simplest approaches to separate metal and others chemicals from aqueous systems. Activated carbon is one of the most widely used adsorbents and it can be used to remove almost all pollutants and metals. However, activated carbon adsorption is suffered from costly regeneration, high attrition rate and low selectivity of pollutants. The low cost adsorbents with good mechanical strength, high adsorption capacities and selectivity have attracted increasing interest from researchers to develop a practical economically adsorbent for separation/extraction of metals. In the past decades, polymeric adsorbents having ion exchanger property have been identified as potential candidate as compared to other adsorbents. This is because it has large surface area, excellent mechanical stability, adjustable surface modification and chemistry, high selectivity and stable after multiple regeneration cycles. Polymeric adsorbents having fibrous structure have been found to perform better in term of its adsorption kinetic and capacity. Radiation induced graft copolymerization is an effective method to prepare adsorbent precursor in fibre form by grafting of monomer onto the fibre and subsequent functionalization to produce fibrous polymeric adsorbents. Thorium adsorbent was prepared by grafting of glycidyl methacrylate (GMA) onto nylon fibres in methanol mediated grafting system. The degree of grafting was calculated from the weight gained of fibers before and after grafting. The grafting was carried out by electron beam irradiation using the pre-irradiation grafting method. The GMA grafted nylon fibres were further modified by reaction glucamine. Then, batch adsorption tests were conducted by adding adsorbent to Erlenmeyer flasks containing thorium solution. The remaining thorium in the solution was tested using inductively coupled plasma mass spectrometry (ICP-MS, Agilent 7900) and standard solutions of thorium at 1 ppb, 10 ppb, 100 ppb and 1000 ppb were used to prepare a calibration curve. Grafting yield of 220% were obtained at 100 kGy absorbed dose, 2 hours reaction time, 40 oC reaction temperature and 10% monomer concentration. The parameters to obtain glucamine density of 2.2 mmol/g adsorbent were 10% glucamine concentration, 80 oC reaction temperature and 1 hour reaction time. The new graft copolymers of GMA and incorporation of glucamine onto grafted fibres were confirmed by scanning electron microscope (SEM) and Fourier transform infrared spectroscopy (FT-IR). A thorium adsorbent containing glucamine functionalized onto GMA grafted nylon-6 was prepared and the maximum adsorption of thorium was achieved at pH 2. The fibrous adsorbent showed > 98% separation of thorium from aqueous solution using adsorbent dose of 0.5 g at 50 mg/L thorium concentration, 3 h reaction time, 30 oC reaction temperature, 200 rpm stirring speed and pH 4. It can be concluded that the thorium adsorbent having fibrous structure was successfully prepared and can be applied for thorium separation from aqueous solutions.
        Speaker: Mr Teo Ming Ting (Malaysian Nuclear Agency, Malaysia)
      • 254
        Fabrication of Advanced Soft Magnetic Nanomaterials Using the Radiation
        Soft magnetic materials have been investigated for applications in magnetic devices such as transformers, inductor, electromagnetic (EM) wave shielding, etc. Its magnetic properties are determined by composition, crystal structures and size. Many kinds of researches are focused on the control of material size chemically and mechanically. Synthesis of particles using an electron beam (EB) irradiation provides stable and high quality. In this study, we synthesized the iron oxide particles using a 10 MeV EB irradiation. This material has fine nano-sphere with Fe3O4 phase in the result analysis of FE-SEM and XRD. And it also possible to fabricate the α-Fe2O3 phase with different precursor compositions. As increasing the electron beam irradiation dose, the saturation magnetization of particles dramatically increased up to 300 kGy. This result is related to the growth of crystal phase. To evaluate the uses of this material in high frequency, the complex permittivity and permeability of composite were measured by network analyzer from 300 kHz to 8.5 GHz in forms of composite in wax matrix. This material shows the high return loss (over than -40 dB) near the 6 GHz. These results clearly demonstrate that the radiation is a good candidate for the nanoparticle fabrication and industrial applications.
        Speaker: Mr Seungho Yu (Korea Atomic Energy Research Institute, Korea, Republic of)
      • 255
        Functional Properties and Ecotoxicity of Bionanocomposites Based on PHBV/PLA Blend under Electron Beam Irradiation
        Aseptic food packaging material is therefore essential to preserve food quality over time. For biodegradable packaging, these materials have to be sterilized or decontaminated prior to use to protect against possible microbial contamination. Since our knowledge about polyhydroxyalcanoates (PHA) for food packaging is rather limited, the challenge is to produce biodegradable primary packaging materials which remain stable without affecting mechanical and barrier properties as well as not resulting in toxicological side-effects during both storage and usage. Therefore, the present article reports some experimental data on the oxidative degradation under e-Beam irradiation of neat poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV), neat polylactide (PLA) and PHBV/PLA blend (50/50 w/w) with and without organo-modified montmorillonite, i.e. Cloisite 30B (C30B) (3 wt %) at absorbed doses of 1 and 10 kGy. The changes in the chemical structure, the molecular weight, the thermal, mechanical and barrier properties as well as the morphology were evaluated. The data showed that e-Beam irradiation of PHBV/PLA blend leads to oxidation reactions involving ester groups in both neat PLA and neat PHBV resulting in the formation of hydroperoxides groups. The presence of C30B in the polymer blend has no influence on the nature of the degradation process. However, the good dispersion of C30B nanoparticles provides more stability to the molar mass and the thermal, mechanical and barrier properties of PHBV/PLA blend. At absorbed dose of 10 kGy, the irradiated samples are completely safe. Though there were drastic changes in the chemical structure of the blends, there was no resulting toxicity as measured using the luminescent bacteria-based bioassay (Microtox).
        Speaker: Ms Mustapha Kaci (University of Bejaia, Algeria)
      • 256
        Functionalization of Polypropylene Films with Glycidyl Methacrylate by Gamma Radiation
        ***Background*** Polymeric materials with biologically active components immobilized onto surfaces are very important for biotechnological and biomedical applications. However, conventional polymers have no appropriate functional groups (amine, imine, carboxyl, hydroxyl, etc.) to immobilize biomolecules. Indeed the polymeric surfaces should be modified to introduce such functional groups; although there are many possible routes to functionalize surfaces, radiation grafting has advantages such as facility in synthesis process and purification of products, initiators or additives are not necessary, etc. Therefore, a possible alternative to obtain surfaces rich in amines is carry out the surface modification by gamma radiation, grafting monomers with functional groups such as primary amino (allylamine), secondary (acrylamides) and derivatives, which can react with diamines such as hydrazine or ethylenediamine to obtain free amino groups. ***Methodology*** Glycidyl metahcrylate (GMA) was grafted onto polypropylene films (PP) using gamma radiation. Direct and oxidative pre-irradiation methods were studied. The evaluated parameters were solvent, monomer concentration, doses, time and temperature. Subsequently, PP-g-GMA films were reacted with amines (ethylenediamine and hydrazine) to obtain functionalized films (amines rich surfaces). Different reaction conditions were tested and optimized. The grafted (PP-g-GMA) and functionalized films were characterized by FTIR, DSC, TGA, angle contact and swelling behavior. ***Results and Conclusions*** GMA was successfully grafted onto PP films using oxidative pre-irradiation and direct method. In both procedures were easy to control the graft percentages (10-200%) varying any parameter such as solvent or dose. The PP-g-GMA was reacted with diamines to obtain aminated films; the introduction of amine groups was confirmed by monitoring the disappearance of epoxy group band at 906 cm-1 in FTIR spectra. The radiation grafting technique can be an easy and quick alternative way to functionalize polymeric materials. ***Acknowledgments*** The authors wish to express their thanks to B. Leal, F. García and M.L. Escamilla from ICN for technical assistance. enter code here
        Speaker: Ms Alejandra Ortega (Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Mexico)
      • 257
        Gamma Radiation Enhancement of Photocatalytic Activity of Conducting Polyaniline–TiO2 Nanocomposites for Degradation of Methyl Orange Dye under Visible Light Irradiation
        Gamma Radiation Enhancement of Photocatalytic Activity of Conducting Polyaniline–TiO2 Nanocomposites for Degradation of Methyl Orange Dye under Visible Light Irradiation H. A. Abd El-Rehim, E. A. Hegazy, S.A. Ismail, N. M. Deghiedy National Centre for Radiation Research and Technology (NCRRT), Egyptian Atomic Energy Authority P.O. Box: 29 Nasr City, Cairo, Egypt Abstract Environmental pollution on a global scale, as well as the lack of sufficient clean energy sources, have drawn much attention to the need for developing ecologically clean chemical technology, materials, and process. Synthetic dyes are used almost in all branches of the consumer goods industry. About 10000 tons of dyes are produced per year. Inevitably, there are dye losses (approximately 12 % of used amount) during manufacturing and processing operations. The effluents from these operations are usually highly colored, toxic, carcinogenic or mutagenic. As the most of the synthetic dyes is resistant to the light or other degradative environmental conditions, it is necessary to remediate these effluents before they are released to the environment. However, common wastewater treatment plants are ineffective in removal of dyes from the wastewaters. One of possible options to modify these facilities to get better outcome is an application of the Advanced Oxidation Processes (AOPs), i.e., chemical methods based on generation of highly reactive hydroxyl radicals. In current research, a series of polyaniline-modified TiO2 nanocomposites for photocatalytic degradation of dyes, have been successfully synthesized by sol–gel reactions on TiO2 followed by the chemical oxidative polymerization of aniline using ammonium persulphate (APS) as an oxidant. Fourier-transform infrared spectra (FT-IR), Thermal gravimetric analysis (TGA), X-ray diffraction (XRD), and UV–vis spectra, were carried out to characterize the composites with different TiO2 contents. The UV–νis spectra confirmed that the optical absorption for PANI-TiO2 nanocomposite was more intensive than that for pristine PANI and TiO2 nanoparticles in the visible light region. The intensive visible light absorption and effective charge separation owing to the heterojunction built between TiO2 and PANI lead to remarkable improvement of visible light photocatalysis. The photocatalytic activities of the prepared nanocomposites were evaluated by photocatalytic degradation of methyl orange (MO) aqueous solution under visible light irradiation. The results showed that the surface polyaniline sensitization had no effect on the crystalline structure but aggravated the agglomeration of TiO2 nanoparticles by forming multi-particles. After being sensitized by PANI, the light response of TiO2 was extended to visible-light regions and the photocatalytic activity of the composite photocatalysts was enhanced. MO could be degraded more efficiently on PANI-TiO2 than on the bare TiO2 when the weight percent of TiO2 was 10wt%. Since gamma-irradiation is able to modify the electronic properties of the photocatalyst, the influence of gamma irradiation on the photocatalytic performance was investigated. A notable enhancement in degradation efficiency and time was found when irradiated nanocomposites were used. It can be included that gamma radiation plays an important role in the photocatalytic activity of PANI-TiO2 nanocomposites.
        Speaker: Ms Sahar Ismail (Egyptian Atomic Energy Authority, Egypt)
      • 258
        In-Situ Compatibilization of Polyblends and Polymer Based Composites Induced by γ-Irradiation
        Interfacial compatibility is an essential factor for polyblends and polymer based composites, which is traditionally improved by addition of copolymers with grafting structure or coupling agents, and reactive blending. The generation and recombination of macromolecular radicals at interface makes gamma-irradiation a potential mean to improve the compatibility of immiscible polymer based multiphase materials. In the present work, polyethylene terephthalate (PET), polylactic acid (PLA), and nylon based polyblends and composites were prepared by melt blending, respectively. Gamma-irradiation in nitrogen atmosphere with various absorbed dose were employed following sample molding. Morphology, chemical structure and mechanical property changes were investigated by SEM, FTIR, gel extraction and mechanical testing. The refinement of the separation particles, the ductile deformation at cross-section and the rough surface of pull-out fibers indicated the obvious improvement of compatibility. Gel extraction results and FTIR of the gel confirmed the generation of grafting polymer containing each component. Mechanical properties were significantly increased as a result of in-situ compatibilization. According to the evidently positive effects on miscibility found in all multiphase materials, gamma-irradiation can be widely-used as an innovative solution to immiscible materials.
        Speaker: Mr Yuan Yin (Changchun Institute of Applied Chemistry (CIAC), Chinese Academy of Science (CAS, China)
      • 259
        In-situ Deposition of Nanohydroxyapatite within N,O-Carboxymethylchitosan/Polyvinylpyrrolidone Hydrogels: Characterization and Bioactivity Evaluation
        Background: Bone is a natural composite; its primary purpose is to provide mechanical support for soft tissues and serves as an anchor for muscles that generate motion. Although, bone has a remarkable ability to regenerate when damaged, treatment of bone defects caused by various reasons still a clinically confusing problem. Of possible choices, autogenous bone transplantation is the optimum choice. Unfortunately, the limited donor source, the damage and complications that may happen to the donor site are the worse limitations. Currently, bone tissue engineering strategies offer promising alternatives for autografts and allografts using scaffolds for guided tissue regeneration. Scaffolds are synthetic grafts, have the ability to promote bone regeneration within the defect site. Scaffolds should be porous to ensure nutrient and waste transport, tissue in-growth, and biological fixation with surrounding tissue. Also, they should be osteoconductive to facilitate bone formation on its surface. Scaffold should have adequate mechanical strength to support bone in-growth at the site of implantation, maintain structural integrity during in vivo tissue remodeling and it should degrade over time in concert with bone formation. Recently, polymeric composite scaffolds are gaining increased attention as synthetic alternatives for bone grafting materials. They improve the bioactivity and mechanical properties so as to meet the basic requirements for bone repair. The development of bone-like composites with enhanced biocompatibility calls for a biomimetic approach using hydroxyapatite [Ca10(PO4)6(OH)2]as a guide. Methodology: Hydrogel matrices based on N,O carboxymethylchitosan and polyvinylpyrolidone (NOCMCs/PVP) were synthesized using -radiation as clean initiator. Alternate soaking method was used to obtain (NOCMCs/PVP)–nanohydroxyapatite composite scaffolds. In vitro bioactivity and biocompatibility evaluation was investigated before and after immersion in simulated body fluids (SBF) to follow the formation of bone like carbonated hydroxyapatite (HCA) layers. Results: After alternate soaking process; the deposition of guided nHA layers onto (NOCMCs/PVP) hydrogels were confirmed using FTIR, EDX, XRD and SEM techniques. EDX analysis confirmed that Ca/P molar ratio (1.62) was very close to the theoretical value of Ca/P molar ratio in human bone (1.67). The development of nHA crystals was confirmed from XRD measurements and the average grain size was found to be in the range of 12-37 nm. The compressive strength for the tested composites recorded comparable values compared to the cancellous bone. Post immersion in SBF, the growth of carbonated apatite (HCA) particles increased by time and the surface appears smooth after 28 days of immersion as it is clear in Figure (1).By increasing HA content, the weight of blood clot formed and the percent heamolysis decreases and tends to zero. Conclusion: synthesis of guided nano-hydroxyapatite layer within (NOCMCs/PVP) hydrogels using alternate soaking is a simple and efficient method. biomineralization process in SBF contributes to the formation of bone like carbonated hydroxyapatite (HCA) layers. In vitro bioactivity and blood compatibility evaluation indicated that nHA-(NOCMCs/PVP) scaffold was bioactive and biocompatible and may be promising for bone repair.
        Speaker: Ms Amany Raafat (National Center for Radiation Research and Technology (NCRRT), Egyptian Atomic Energy Authority, Egypt)
      • 260
        Influence of the Coolant Chemistry on the Structural Materials Surfaces Exposed into the Candu NPP Primary Circuit
        One of the most important plant system is Primary Heat Transport System (PHTS) having in view its role in active zone cooling and heat transfer to steam generators. In PHTS the chemical control is directed to keep chemical parameters within specified limits in order to mitigate the corrosion of the key equipment and related piping, to control the corrosion rate and impurities concentration, such as corrosion and fission products and to minimize activity transport and heat transfer surfaces fouling. By operation in aqueous environment at high temperature and pressure, the structural materials from PHTS cover with protective oxide films, which maintain the corrosion rate in admissible limits. A lot of potential factors exist, which conduct to degradation of the protective films and consequently to intensification of the corrosion processes. The existing experience of different nuclear reactors shows that the water chemistry has an important role in maintaining the integrity of the protective oxide films. In order to minimize the adverse effects, an optimal water chemistry control and corrosion monitoring programme were established. The understanding of the corrosion degradation phenomena that conduct to failure of some components from PHTS of CANDU NPP implicates the investigation of the structural materials corrosion processes, in different conditions of water chemistry and temperature. To investigate the corrosion process of some structural materials from PHTS (Zr and Ni alloys) of CANDU 6 reactor were perfomed the following activities:  out of pile corrosion experiments in different conditions of water chemistry;  corrosion experiments in autoclaves assembled in by-pass of CANDU 6 reactor PHTS;  corrosion analysis performed on some corroded components. The gravimetric method, optical metallographic microscopy, XRD analysis, as well as electrochemical measurements have been used to evaluate the corrosion behavior of the pressure tube and steam generator tubing materials. The obtained results allowed us to establish the contribution of the water chemistry in the initiation and evolution of some accelerated corrosion processes.
        Speaker: Ms Dumitra LUCAN (RATEN ICN, Romania)
      • 261
        Investigations on Immobilizing Anthocyanin and Betacyanin onto Polyethylene Films
        The use of plastic polymers for food packaging has increased significantly over the past decades and the global market for polymers has increased to about 100 million tons today. Most of the packaging polymers are petroleum-based for cost reasons, ease of application and worldwide availability. However, besides serving as a physical containment for foods there is a growing need for food packaging to have additional properties. These include but not limited to serving as a substrate for antimicrobials and phytochemicals, platform for sensors to detect food spoilage, food deterioration, pathogen presence, potential deliberate contamination, as well as physical contaminants such as glass, metal pieces. Phytochemicals are the secondary metabolites formed in fruits and vegetables that have a variety of health benefits. Two major phytochemicals present in fruits and vegetables are anthocyanins and betacyanins. Anthocyanins are a large subclass of flavonoids that are distinguished for their strong red to blue color in a variety of fruits and vegetables. Anthocyanins are potent antioxidants due to their phenolic structure and have antimicrobial function. We hypothesised that anthocyanin and betacyanin can be grafted directly onto PE using varying doses on eBeam and utilizing different types of extracted phytochemicals (source, and extraction method). We studied the grafting yield as well as the quality and functionality of the grafted phytochemicals. It is concluded that anthocyanin specifically when extracted with alcohol has a relatively good stability to high doses of eBeam even all the way up to 100 kGy. Anthocyanins can maintain their properties to a considerable degree; however, betacyanins are not resistant to eBeam irradiation. Polyethylene is a very strong and resistant polymer that even a high dose of 1000 kGy does not affect its surface or its properties. Therefore, polyethylene is not an ideal polymer backbone for grafting organic and phenolic materials.
        Speaker: Ms Shima Shayanfar (Texas A&M University, United States of America)
      • 262
        Ionizing Radiation as a Tool to Affect Polymer Biodegradation
        The great stability and durability of conventional synthetic plastics and their outstanding properties have allowed a wide range of potential applications among which packaging constitutes the larger market segment. However, due to the specific function, packaging rapidly becomes waste that increasingly accumulates in the environment. Therefore, nowadays the need of biodegradable polymers is growing up and great efforts have been devoted to optimize the use and the disposal of conventional non-biodegradable plastics favoring their degradation in the environment. Aliphatic polyesters have attracted considerable attention combining biodegradability and biocompatibility features with physical-chemical properties comparable with some of the most extensively used polymers. It is well known that ionizing radiation can modify polymers and enhance or degrade their properties, affording many practical applications. In particular, gamma radiation can facilitate the material degradation by inducing oxidative fragmentations of polymer backbone. In this viewpoint, experimental activities have been addressed to investigate if a radiation treatment of bio-based plastics in an ambient promoting or accelerating degradation, could represent an effective pre-treatment for improving their biodegradation. Commercial and synthesized polymers, such as polyethylene (PE) and polybutylene succinate (PBS), have been irradiated by Co-60 sources and the impact on the rate of biodegradation in compost has been evaluated. Polyesters, in films up to 200 µm, have been irradiated at absorbed doses up to hundreds of kGy in air and aqueous solution, and examined by different techniques. Radiation-induced changes of the chemical properties have been evaluated as a function of the absorbed dose and the effect of the oxidative ambient has been compared with that of irradiation in air. The molecular weight data obtained by Gel Permeation Chromatography indicate that biodegradable polymers show a more significant loss of molecular weight with respect to PE as the dose increases. On the contrary, the thermal behavior investigated by Differential Scanning Calorimetry does not seem to be affected by the treatment at these absorbed doses. In addition, the surface properties have been carefully evaluated in order to correlate their changes to the biodegradability in compost. In the case of PBS systems water contact angle measurements show that the hydrophilicity is affected already at the lowest absorbed doses, coherently with the remarkable decrease of molecular weight. The research performed confirmed that the radiation-induced degradation could be considered as an effective pre-treatment able to enhance the biodegradation rate of some polymeric systems.
        Speaker: Ms Maddalena Negrin (Politecnico di Milano, Italy)
      • 263
        Ionizing Radiation Engineered Functional Nanogels for Biomedical Applications
        Nanoscale therapeutic systems have emerged as novel therapeutic modalities for cancer treatment and are expected to lead to major advances in cancer detection, diagnosis and treatment. At Nuclear Malaysia we have developed a nanoplatform that would be suitable to use for the targeted delivery of imaging and therapeutic agents. Nanogels are nanoparticles consisting of internally cross-linked hydrophilic polymers of sub-micrometer size. The polymeric nanogels used in this study were synthesized via irradiation of polyethylene glycol-diacrylate (PEG-DA) using electron beam. Radiation induced synthesis of nanogels not only ensures polymer cross-linking, but also particle size control, chemical functionalization and sterilization of the product material. In addition it has the advantage of ease of scale up and the absence of potentially toxic monomers and cross-linking agents. With superior colloidal stability, inertness in the bloodstream and high drug loading capacity, nanogels make an ideal nanocarrier for biomedical applications. The prepared nanogels were characterized by scanning electron microscopy (SEM). Their size and zeta potential were measured using dynamic light scattering and zeta potential analyzer respectively. Biocompatibility of the nanoparticles were assessed by MTT assay. To assess the applicability of the nanogels as a drug carrier, a tumor targeting peptide is appended to the nanoparticle to endow it with tumor homing/targeting capability. Additionally, to track its biodistribution in vivo, it was radiolabeled with a suitable positron emission tomography (PET) radioisotope and scanned using a PET camera to assess its tumor targeting capability and accumulation.
        Speaker: Ms Siti Mohd Janib (Medical Technology Division, Malaysian Nuclear Agency)
      • 264
        Irradiation Effects on Structure and Spectroscopic Properties of Sugar Doped Sol–Gel Silica.
        The silica xerogels doped sucrose was prepared via sol-gel process and exposed at room temperature to different doses of high energy (60Co) gamma irradiation. Changes in the physical properties of the xerogels before and after irradiation were characterized by using UV–visible and FTIR spectra of pristine and irradiated xerogels with varying of gamma doses rays, showing a variation in the gap energy. It was found that the gamma irradiation influences the optical properties and modifies the network structure. Then, results indicate that the gap energy of the investigated silica xerogels decreases with increasing the gamma irradiation doses. Thereby the irradiated samples reveal behaviour changes, from an insulator (Eg ~5.8 eV) towards a semiconductor with (Eg~ 3.5 eV).
        Speaker: Ms Kaouther MARZOUKI (National Center for Nuclear Sciences and Technologies, Tunisia)
      • 265
        Lifetime Study of Electronic Devices for Extreme Radiation Conditions
        **Background** Recent boom in radiation technology development and increasing number of its emerging applications bring new requirements on related devices. Electronic devices connected to all aspects of our lives today proceed presently with highest speed. However, they are sensitive to radiation. The study of radiation effect on electronic devices is important for increasing their lifetime and the reliability of the whole technology, when used in radiation harsh environment like space, large accelerators, nuclear reactors etc. Our University Centre of Electron Accelerators (UCEA) is equipped with modern research linear electron accelerator with convertor to X-rays. We have studied the effect of both the X-rays and the high energy electrons on lifetime of devices used in radiation extreme conditions. The CERN accelerator component was tested by high energy electrons, the semiconductor devices for the first Slovak satellite were irradiated by X-rays and the semiconductor detectors for radiation imaging and dosimetry were tested by high energy electrons and compared to the experimental results obtained by their gamma-ray and fast neutron irradiation. **Methodology** The devices were tested at linear electron accelerator UELR-5-1S with scanning pulsed beam at UCEA in Trenčín, Slovakia with 5 MeV electrons. The repetition rate of the beam pulse can be set in the range from 5 to 240 Hz, which enables the dose rate to be modified. The electron beam has been scanning the width of 40 cm and the irradiated object either moved beneath the scanning beam (CERN accelerator component) or was irradiated in steady mode (small objects). The CERN accelerator component was irradiated by 5 MeV electrons up to a dose of 2 MGy, to reveal its most radiation sensitive parts. Various commercial semiconductor devices for the skCUBE satellite power supply unit were tested by electrons converted to X-rays up to a dose of 1300 Gy representing the dose obtained by satellite on its orbit during more than 3 years. Finally, the semiconductor detectors were irradiated by 5 MeV electrons studying the effect of radiation of their detection properties and compared to the effects of other kinds of radiation: the fast neutrons and gamma-rays. **Results and conclusions** Our study has proved the functionality of the CERN accelerator component, the engine for dipole precise positioning, up to 2 MGy. However, the plastic parts of the component were destroyed mechanically only and had to be removed in final product. The commercial semiconductor devices for satellite power unit from various manufacturers were tested up to a dose of 1300 Gy of X-rays. The tested voltage references exhibited increasing output voltage with applied dose, spoiling the reference functionality. In the second kind of device degradation, the functionality was preserved, but the input current dramatically increased (e.g. battery chargers). In the case of semiconductor detectors, some of their detection properties improved (energy resolution) at small doses (1-2 kGy) followed by their degradation. However, after 120 kGy dose of electrons, the detectors were still functional with acceptable detection properties.
        Speaker: Ms Andrea Sagatova (University Centre of Electron Accelerators, Slovak Medical University in Bratislava, Slovakia)
      • 266
        Low Dimensional Nanomaterials-Based Interfacial Engineering in Organic Solar Cells
        We have demonstrated a facile but efficient preparation of a solution-processable transition metal oxide nanoparticles or nanosheets-incorporated reduced graphene oxide (TMONP/RGO or TMONS/RGO) and excellent organic photovoltaic cells using the TMONP/RGO or TMONS/RGO to function as a hole extraction layer (HEL). The TMONP/RGO or TMONS/RGO, featuring uniformly decorated high-quality TMONPs or TMONSs on RGO, can be synthesized via a simply adding a precursor solution into RGO prepared by an electron beam irradiation method. Compared with the reference PEDOT:PSS-based cells, the TMONP/RGO or TMONS/RGO HELs provide superior performance characteristics as a result of better electrical conductivity and more uniform film quality than that of PEDOT:PSS. In particular, the high performance can be realized irrespective of the thermal treatment conditions of a solution-processed TMONP/RGO or TMONS/RGO layer, which is a crucial difference from the previously reported solution-processed metal oxide-based HELs. These results clearly demonstrate that the TMONP/RGO or TMONS/RGO, prepared by a facile and efficient method, is a promising hole-transporting material and a potential alternative to PEDOT:PSS, thus further realizing an efficient and stable OSCs.
        Speaker: Mr Seungho Yu (Korea Atomic Energy Research Institute, Korea, Republic of)
      • 267
        Mechanical Characteristics and Antibacterial Properties of Ag-Poly(Vinyl Alcohol)/ws-Chitosan Hydrogel Nanocomposites Synthesized by $\gamma$-Irradiation Combined with Freeze/Thaw Cycles
        Hydrogels have been used successfully in many biomedical applications including scaffolds for wound healing applications or soft tissue implants. A problem for the biomedical application of hydrogels is that microorganisms may grow in hydrogels due to their natural biocompatible properties. Improvement in application of hydrogels is often achieved by the addition of natural polysaccharide or non-specific antimicrobial species such as Ag nanoparticles. The antibacterial bio-synthetic hydrogel nanocomposites consist of blends between water soluble derivatives of radiation processed chitosan (ws-chitosan) and poly(vinyl alcohol) cross-linked by $\gamma$-irradiation (via $^{60}$Co source) and radiation in situ incorporated Ag nanoparticles (AgNPs). Chitosan is a copolymer composed of glucosamine and N-acetyglucosamine sugars, linked by $1$–$4$ glucosidic bonds, both of which are constituents of mammalian tissues. Chitosan degradation by ionizing radiation gives structural diversity which contributes to its wide application in biomedicine. The radiation technology platform allows synthesis by environmentally friendly and biocompatible radiolytic products of water. The postirradiation hydrogel freeze-thaw procedure was performed to enhance mechanical properties and to prevent liking of un-grafted ws-chitosan during AgNPs synthesis. The thus obtained ws-chitosan, poly(vinyl alcohol)/ws-chitosan polymer matrix and nanocomposites were subjected to molecular weight determination (by Zetasizer), FT-IR, NMR, SEM, elemental analysis and mechanical characterization by thermomechanical analysis, in static stress/strain and dynamic mode. The antibacterial properties against *Escherichia coli* and *Staphylococcus aureus* were assessed by using the agar diffusion test. Results revealed the partial formation of Maillard reaction products during radiation degradation of chitosan. The non-linear stress-strain data from unconfined compression test were fit by the Kennedy equation and by an elastic model (Rige and Wright). The results indicated changes in matrix mechanical resistance upon incorporation of ws-chitosan. In contrast, AgNP incorporation decreased the polymer matrix elasticity while increasing the cross-linking density of polymer network and provides more rigidity to the structure which increases the values of storage modules (obtained in dynamic mode) and, as a consequence, causes a better mechanical stiffness of the network. The antibacterial activity of Ag-poly(vinyl alcohol)/ws-chitosan hydrogels show enhanced antibacterial potential in comparing with poly(vinyl alcohol)/ws-chitosan hydrogel matrix only. For investigated hybrid hydrogel, zone of inhibition is greater against *Staphylococcus aureus* than for *Escherichia coli*. This is important for the treatment of wound infections in diabetic patients which are dominantly caused by aerobic Gram-positive cocci. These promising results give possibility for development and optimization of synthesized antibacterial Ag-hydrogel nanosystems.
        Speaker: Ms Jelena Krstić (Vinča Institute of Nuclear Sciences, University of Belgrade, Serbia)
      • 268
        Metal Surface Modification with Fatty Acids Using Ionising Radiation
        **Background of the study.** Various metals and alloys are commonly used in medicine. As such they are often exposed to aggressive environments and thus subjected to corrosion, i.e. dissolution. Thus, modification of the metal surface is interesting since this way the resistance to corrosion can be increased and the durability of the object can be prolonged. Medical equipment, in most cases, must be sterilized and a common method is using ionizing radiation. While ionizing radiation does not markedly influence the properties of the metal it can influence the protective layer that is formed on its surface. Fatty acids are non-toxic compounds which have an affinity for self-assembling on metals and therefore lately they have been investigated as possible protective layers on metals. The influence of ionizing radiation on the formation of such a layer is needed to determine weather it changes the properties of the protective layer or maybe even enhances them. **Methodology.** Procedures for adsorption of self-assembling layers of fatty acids on metals exist in literature. This work studies influence of ionizing gamma-radiation on the process of assembling such a layer and the efficiency of the outcoming layers in corrosion protection. Various variables are studied. The most important variables are the applied dose of gamma irradiation, as well as the dose rate at which it is applied. The quality and efficiency of the obtained layers in corrosion protection are studied by electrochemical methods. **Results.** The results have shown that the layer of fatty acid that forms on the surface of the metal using ionizing radiation offers additional protection to the bare metal making it more resistive to corrosion. **Conclusion.** For successful formation of a protective layer on the metal it is essential to determine the proper molecule which has good adhesive properties and to irradiate with an appropriate dose, at an optimal dose rate.
        Speaker: Ms Katarina Marusic (Ruder Boskovic Institute, Croatia)
      • 269
        Monodispersed Polypyrrole Nanoparticles Prepared via Water Padiolysis and their Photothermal Therapy on Cancer Cells
        The combination of NIR photothermal therapy and chemotherapy is considered as the promising technique for the future cancer therapy.[1] The key point for this technique is the design and synthesis of photothermal agents with high-efficiency phtotothermal effect and high chemical drug loading capacity.[2] Herein, submicron-sized raspberry-like hollow-structured polypyrrole microspheres (H-PPy) were facily prepared through the in-situ polymerization of pyrrole on monodispersed polystyrene (PS) template microspheres with a diameter of 220 nm, followed by the chemical etching of the PS templates. The prepared H-PPy microspheres show rapid and remarkable photothermal effect in water under the irradiation of NIR laser (808 nm) only for 5 min. Further, a model small molecular drug, (S)-(+)-camptothecin (CPT), were loaded into the void core by a simple dispersion-permeation process through the micro-pores on the raspberry-like PPy shell, with a load capacity of 0.14 mg/(mg H-PPy). The MTT assay and the in vitro NIR-laser triggered release behavior indicated that the pure H-PPy microspheres have good biosafety, but the release of loaded CPT in H-PPy microsphere can be achieved with remarkable spatial/temporal resolution after NIR laser irradiation, which results in the excellent synergistic effect of photothermal and chemical ablation on HeLa cells, as proved by the fluorescence microscopy. This work provides a convenient synthesis of a promising cancer therapy agent with high drug-loading capacity and efficient NIR light photothermal effect, which can perfectly achieve the synergistic NIR photothermal therapy and chemotherapy of PPy microspheres. [1] K. Dong, Z. Liu, Z. H. Li, J. S. Ren and X. G. Qu, Adv. Mater., 2013, 25, 4452-4458. [2] J. P. Yang, D. K. Shen, L. Zhou, W. Li, X. M. Li, C. Yao, R. Wang, A. M. El-Toni, F. Zhang and D. Y. Zhao, Chem. Mater., 2013, 25, 3030-3037.
        Speaker: Mr Xue Wu GE (Department of Polymer Science and Engineering, University of Science and Technology of China, China)
      • 270
        Morphological, Physico-Chemical and Mechanical Properties of Radiolytically Synthesized Nano-Ag/poly(N-isopropylacrylamide) Hydrogels
        Hydrogels have unique properties and many potential applications, especially in the field of medicine and biotechnology. The gel porosity and swelling properties, stability and strength, biodegradability and biocompatibility are characteristics which are widely variable and easily adjusted. Stimuli responsive or intelligent hydrogels are special class of these materials which shows significant response to small changes in surrounding environment such as temperature, pH, ionic strength, electric field and light. From a biomedical point of view, thermo- and pH-sensitive polymers are the most frequently studied. Poly(N-isopropylacrylamide) (PNiPAAm) is one of the most investigated thermosensitive polymer with a sharp lower critical solution temperature (LCST) at around 32 °C which can be adjusted by copolymerization and/or addition of salts or surfactants to the initial polymer solution. On the other hand, silver nanoparticles (AgNPs) have been the subject of intense interest due to their size-dependent optical, catalytic and electronic properties as well as remarkable antimicrobial potential. AgNPs possess capability to release Ag+ ions in a controlled manner which leads a powerful antibacterial activity for large number of bacteria. This controlled release can be provided by incorporation of nanoparticles in crosslinked polymer network. Among many methods for synthesis of nanocomposites, gamma irradiation induced synthesis has been recognized as highly suitable tool. In this work, synthesis of nanocomposites was conducted as two-step process. In the first step, polymerization and crosslinking of polymer chains occurs and PNiPAAm hydrogels with a large number of pores were obtained. In the second step, these pores serve as nanoreactors for reduction of Ag+ ions and formation of AgNPs. Absorption spectra of nano-Ag/PNiPAAm hydrogel nanocomposites, with characteristic peaks in the range of 390-415 nm, confirm the successful formation of AgNPs inside PNiPAAm hydrogel matrix. Morphological analyses (SEM and micro-CT) reveal the existence of pores with different size, dependent on PNiPAAm concentration, but independent on incorporation of AgNPs. Structural analysis indicates the presence of spherical AgNPs, with the mean diameter up to 20 nm and face centered cubic crystal structure. Swelling processes of investigated systems show thermoresponse with the volume phase transition temperature (VPTT) between 30.5 and 31.6 °C. The possibility to apply nanocomposites for controlled release of active silver was investigated by monitoring the release kinetics of Ag+ ions in a buffer solution (pH 7.4) at 25 °C. The obtained results are modeled by applying five different pharmacokinetic models (Korsmeyer-Peppas, Higuchi, Hixson-Crowel, Kopcha i Makoid-Banakar model). The best fit solution gave Kopcha and Makoid-Banakar models, indicating that the release of Ag+ ions was predominantly controlled by a diffusion process. The results obtained from compression measurements shows that mechanical properties of investigated hydrogels strongly depend on concentration of polymer matrix as well as on concentration of incorporated AgNPs.
        Speaker: Ms Aleksandra Radosavljević (Vinča Institute of Nuclear Sciences, University of Belgrade, Serbia)
      • 271
        Nanocarbon Based PolyLY(Ethylene-Terephtalate) Nanocomposites and Various Irradiations
        Background of the study Ionizing and UV radiation produce reactive species in irradiated material. The concentration and distribution of those species depends on the linear energy transfer rate of a corresponding radiation type. Electromagnetic radiation like gamma or X-rays has high penetration but relatively few reactive species form relatively far apart. Particulate radiations like protons produce high concentration of ionizations and break a lot of chemical bonds along their tracks but have much lower penetration. All ionizing radiation types have enough energy to break any type of chemical bonds while UV can induce breaking only of some less stable chemical bonds. The type of radiation and its quantity, dose, are not the only factors that determine the response of polymers and (nano)composites. It depends also on the chemical structure of the polymer matrix so the overall outcome can be degradation, cross-linking and/or latent track formation. Poly(ethylene terephtalate) (PET) is widely used thermoplastic polymer with excellent engineering properties and its radiation stability is expected increase on addition of appropriate (nano)fillers. Methodology Pure PET film and two of its nano-carbon containing nano-composite films, one with nano-diamonds (ND) and the with other combination of nano-diamonds and graphene nanoplatelets (NGP) were studied. One group of samples was irradiated with 60-Co gamma radiation in range between 0.2 and 1. 05 MGy at a dose rate of 2.5 Gy/s, in contact with air. The other group was irradiated with a 3 MeV proton beam delivered by the 1.0 MV Tandetron (at the fluences of 1014 p/cm2 and 1016 p/cm2) in vacuum. The third group was exposed to UVC radiation (wavelength 254 nm, the lamp intensity 9 mW). Irradiation effects were studied using thermal and spectroscopic methods. Results Thermal analysis by DSC showed that the crystallinity of PET was just minimally affected by introduction of nanofillers. Various irradiation types produced different outcomes. DSC revealed that ordered amorphous phase of irradiated samples was more influenced than its mobile segment and crystalline was the least affected. Only slight changes were observed in PET and the nanocomposites irradiated up to 0.5 MGy with gamma irradiation. Proton irradiation produced much more damage. Graphene containing nanocomposite was more resistant to proton irradiation than the one containing only nano-diamonds. On the other hand UV radiation produced the most significant degradation in all samples and particularly in graphene containing nanocomposite. Conclusions The irradiation outcome of PET and its nano-carbon containing nano-composites depended primarily on the radiation type while nanofiller had only slight influence. The most sensitive part was ordered amorphous phase of PET matrix. All samples were relatively stable to gamma-radiation. Pure PET was significantly degraded by proton irradiation while UV produced the most degradation in graphene containing nanocomposite.
        Speaker: Ms Irina Pucić (Ruđer Bošković Institute, Croatia)
      • 272
        Nanogels of Polyvinylpyrrolidone Obtained by Gamma Radiation. Physicochemical and Biological Characterization
        Background of the study Nanogels are nanoscale polymeric matrices with strong affinity for aqueous media. They exhibit stability, are inert to blood flow and favour the incorporation of medicinal drugs and bioactive molecules improving their therapeutic value by increasing bioavailability, solubility and retention time. The aim of this work was the preparation of polyvinylpyrrolidone nanogels induced by $\gamma$-irradiation, for evaluation as potential drug delivery system. Methodology Experiments were performed in absence of oxygen using diluted aqueous solutions of PVP. The synthesis was carried out in sealed vials in N$_2$O atmosphere irradiated with different absorbed doses on a $\gamma$-irradiation facility ISOGAMMA LLCo. The nanogels were characterized by viscometry, spectroscopy (ATR and UV-vis), thermogravimetry (TGA), diffraction (XRD), electron microscopy (TEM and SEM), dynamic light scattering. Cytotoxicity studies were performed by the of NBT and MTT tests. Results The viscometric results show a decrease in intrinsic viscosity with increasing dose accompanied by an increase in molecular weight. Such behaviour indicates the formation of intramolecular cross-linking by nanogels. The nanogels have an average size of $50$ nm with a dispersion of $1.04$. The XRD showed certain order in the morphology of the nanogels. Gels are spherical in shape and have a marked protective effect on cell viability. In the interval of concentrations studied ($0.001$–$0.8\%$) the more dilute systems favoured the formation of nanogels, whereas the more concentrated ones promoted the appearance of microgels IR spectra and thermal behaviour of nanogels coincided with those of the polymer in bulk. Biological test showed a high biocompatibility. Conclusion Nano PVP gels were obtained using $\gamma$-radiation. It was shown that the degree of cross-linking of the polymer depends on nanogels concentration and the absorbed dose. The obtained nanogels do not exhibit toxicity to cells, and rather have a protective or stimulator effect on cell viability, property which makes them good candidates as platforms for delivery systems.
        Speaker: Mr Manuel Rapado Paneque (Center for Applied Technologies and Nuclear Development CEADEN, Cuba)
      • 273
        Obtention and Characterization of Gamma Irradiated Recycled HDPE/EPDDM Blends
        Elastomeric materials have specific properties that allow the development and use of a variety of products. The application of elastomeric compounds in the automotive industry has increased considerably; due this, high volume of parts are disposal and among these, thermosetting materials, that are not easily recyclable. High Density Polyethylene (HDPE) is a commodity material with a wide range of uses in the industry. What make this polymeric material so interesting to the market are its unique properties such as good conformability, high resistance to heat and chemicals, and a relative low cost. Another characteristic for this material is its good reprocessability, which is the ability of being recycled many times.Thus, the environmental impact of both materials is evident, thereby promoting essential damage. The present work the High Density Polyethylene (HDPE) matrix has been recycled four times from original substrate and mixed to EPDM rubber not vulcanized in proportions from 1 % to 10 %. The gamma irradiation process was applied at 50 kGy and 100 kGy in both original and recycled blend samples; in this way, mechanical properties and morphologic characteristics were evaluated. The results shown EPDM in quantities of 1 % bring high tensile strength and yield strengh to recycled non-irradiated blends compared to higher concentration of 10 %, that present high impact resistance. Irradiation process applied to these samples carried an increase in these parameters and the recycled blends presented higher tensile strength values than pristine HDPE samples. Blends are homogeneous and presented no specific morphologic aspects that suggests HDPE and EPDM are miscible and compatible components; crystallinity is higher in low EPDM content blend and at a dose value of 50 kGy the crystallinity reached the maximum value of 79,5 % compared to 72,2 % for pristine HDPE. These results suggest irradiated blends formed by recycled HDPE with 1 % of EPDM present high viability for industrial use due its high mechanical performance compared its low production cost.
        Speaker: Ms Aurea Geraldo (Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, Brazil)
      • 274
        Optimization of Electron Beam-Induced Synthesis of Polypropylene-g-poly(Glycidyl Methacrylate) for Cr(VI) and Cd(II) Adsorption Using Full Factorial Design
        Graft copolymerization is an efficient and attractive method to impart a variety of functional groups to commercially available polymers. This method allows the development of new materials that cannot be synthesized using conventional processes. In this work, carboxylic acid- and amine-type adsorbents were developed from polypropylene nonwoven fabric (PP NWF) using the emulsion phase radiation-induced graft polymerization (RIGP) technique. The set of optimum parameters (e.g. absorbed dose, reaction time, monomer concentration) for grafting glycidyl methacrylate (GMA) on PP trunk polymer was determined using full factorial design. Post-grafting reactions of the poly(glycidyl methacrylate) (PGMA) grafted on PP NWF with ethylenediamine (EDA) and iminodiacetic acid (IDA) imparted approximately 3.0 and 1.2 mmol functional groups per gram-adsorbent, respectively. These covalently bonded chemical groups serve as active sites in the removal of Cr(VI) and Pb(II) from aqueous solutions. Preliminary data suggest that the EDA and IDA functionalized PP has high affinity for Cr(VI) and Cd(II) ions, respectively.
        Speaker: Mr Jordan Madrid (Philippine Nuclear Research Institute, Philippines)
      • 275
        Prediciting the Behavior of a Biomaterial as Bone Replacement
        When an artificial material is implanted into the body, a fibrous capsule may appear separating the material and the tissue. But when the material is bioactive, this capsule doesn’t appear, and the biomaterial conducts the formation of an interfacial bonding between the implantable device and living tissues, called apatite. The bioactivity is defined as the biologic positive answer in a determined biological environment (human body or a simulated human environment). When the feasibility of developing a new biomaterial is evaluated, it is important to know their bioactivity because this may predict the bone-forming ability of an implantable material for bone tissue replacement. Another property that helps in this prediction is the bio-evaluation of these materials, where the initial evaluation involves the citotoxicity, among others. The citotoxicity determines the possible toxicity produced on cells by the device, and also considers the nature of body contact and duration of contact. The objective of this study was to analyze the bioactivity and cytotoxicity of a biomaterial considered for bone replacement, consisting of high density polyethylene (HDPE) with a load of hydroxyapatite (HA). Biomaterial samples were prepared by extrusion as flat and rectangular specimens composed of HDPE and different loads of HA (100:0; 90:10; 70:30; 50:50); and they were irradiated with different gamma radiation doses (15; 30 and 45 kGy). Radiation is used to promote crosslinking of the material, minimizing wear under physiological conditions, and also for sterilization. To assess the bioactivity a blood similar solution was used (ISO 23317). The samples were incubated for 30 days. Their surfaces were analyzed by Scanning electron microscopy (SEM) and the cristallinity of the HA produced on the surface was determined by X-ray diffraction (XRD). Citotoxicity was conducted using the MTT assay determining the cellular viability (ISO 10993-5). The results obtained by XRD and SEM showed an homogeneous formation of HA crystals, without differences between compositions and irradiation doses. Only in the samples 100 % HDPE did not present apatite crystals on its surface. All samples showed viability higher than 70%, indicating that no cytotoxicity was generated in any condition. Based on the obtained results, the biomaterial samples composed of HDPE and HA were bioactive and non-cytotoxic. Therefore the biomaterial seems to be a good bone tissue implant. These studies carried out, showed to be very useful, as a preliminary or screening step, before starting with the clinical trials. They can reduce costs, when the composition or the process has to be changed before going forward. On the other hand, when the results are satisfactory, they can predict that these materials will generate an appropriate beneficial cellular or tissue response in that specific situation. It has been demonstrated that materials that possess favourable hydroxiapatite layer formation integrate more successfully in the body. Additional tests are underway on this biomaterial to define which the best composition is and which is the optimal radiation dose that generates a simil-bone biomaterial, with similar mechanical properties, and with minimal degradation debris.
        Speaker: Ms Maria Carolina Anessi (Laboratorio de Biotecnologia, CNEA, Argenina)
      • 276
        Preparation of Selective Hazardous Metal Ion Adsorbents from Acrylic Monomer Grafted PET Films
        Heavy metal pollution has become one of the most severe environmental problems today. The well-known environmental destruction cases caused by heavy metals: Minamata disease (organic mercury poisoning), Itai-itai disease (cadmium poisoning) imposed stricter regulation on the treatment of metal contaminated waste water prior to its discharge to the environment. In the present study acrylic monomer grafted polyethylene terephthalate (PET) films were prepared and examined for selective adsorption of hazardous heavy metal. The γ-ray induced grafting of acrylamide (AAm) and acrylic acid (AAc) onto PET films were carried out separately. Grafting of AAm and AAc on PET films was characterized by FTIR and SEM. The grafted films were further modified through alkali hydrolysis to improve the metal adsorption capacity. The hydrolyzed AAm grafted PET films containing amide groups were used to study Hg(II) adsorption and the hydrolyzed AAc grafted PET films containing carboxylate groups were used to study Cu(II) adsorption. The hydrolyzed AAm grafted PET films were investigated for selective Hg(II) adsorption from mixture of Hg(II) and Pb(II) and the absorbent film showed high selectivity for the adsorption of Hg(II) over Pb(II) throughout the entire pH range (2.2–5.6) studied. The hydrolyzed AAc grafted PET films were used to study the selective Cu(II) adsorption from mixture of Cu(II), Co(II) and Ni(II) and the adsorbent film showed high selectivity towards Cu(II) in presence of Cu(II), Co(II) and Ni(II) in the pH range 1.5 to 4.5. Isotherms of selective metal adsorption were analyzed by using Langmuir isotherm model and kinetics of selective metal adsorption were investigated using pseudo-first-order and pseudo-second-order kinetic models. Desorption and reuse of the adsorbent films was also studied. Thus present study indicated that the functional monomer grafted PET films can be effectively used for selective adsorption.
        Speaker: Ms Nazia Rahman (Bangladesh Atomic Energy Commission, Bangladesh)
      • 277
        Radiation Development of (Polyvinyl Pyrrolidon/Acrylic Acid)- Silver Nanocomposite for the Disposal of Phenolic Compounds from their Aqueous Solutions
        Nitroaromatic compounds are considered to be amongst the most prevalent organic pollutants in waste water. They are intermediates or side products of many industrial products such as dyes, pharmaceuticals, agrochemicals, cosmetics, photographic chemicals, additives, chelating agents, and other products. 4- nitrophenol (4-NP) is a notorious industrial pollutant exhibiting a high solubility and stability in waste water. The direct exposure to these pollutants causes inflammation of eyes, skin and respiratory tract and prolonged contact with skin may cause an allergic response. Much effort has been expended to develop methods for removing the aromatic pollutants from wastewater. The reduction of nitroaromatic compounds to the benefit amines is considered to be the most efficient, green, and economical approach to disposing of the nitro-compounds. The reduction product, 4-aminophenol (4-AP), can be reused because it is important intermediate for the synthesis of drugs and dyes. Therefore, various nano-particles have been employed as an effective catalyst for the reduction of nitroaromatic compounds in aqueous solutions under mild conditions. The main issue hinders the pervasive use of homogeneous metal nano-particles as a catalyst is their high tendency to aggregate as a result of the size and high surface energy of metal nano-particles. Moreover, the problems in separating the products contaminated with unstable residuals and recycling the expensive catalysts. To prevent aggregation of metal nano-particles, diverse supportive materials such as hydrogels are widely employed. Hydrogels are hydrophilic polymeric three-dimensional networks capable of absorbing a large amount of water. The catalytic reactions can take place within the boundaries of hydrogels, no need to change many reactor conditions in industrial applications; just a right choice of hydrogel-composites can supply all the necessary conditions. In this study poly vinyl pyrrolidone/acrylic acid (PVP/AAc) hydrogels were prepared via gamma irradiation technique. (PVP/AAc) hydrogel was utilized as a supporting material to stabilize Ag nano-particles by employing in situ method to obtain (PVP/AAc)/Ag nanocomposite. The catalytic activity of (PVP/AAc)/Ag nano-composite was investigated in the reduction of (4-NP) in sodium borohydride solution (NaBH4). Parameters that affect the reduction rate were investigated. It was found that the reaction proceeded with the conversion exceeding 99.8% at a reaction time of about 5 min for (PVP/AAc)/Ag nano-composite loaded with 231.76mmol/L Ag. The rate of the reduction reaction decreased with increasing the concentration of 4-NP and the optimum concentration of NaBH4 was found to be 0.16mol/L.
        Speaker: Ms Ghada Mahmoud (National Center for Radiation Research and Technology, Atomic Energy Authority, Egypt)
      • 278
        Radiation Synthesis of Acrylic Acid onto Poly(tetraflouroethylene-perflourovinyl ether) Film: Chemical Modifications and Electrical Conductivity
        Graft-polymerization of acrylic acid (AAc) monomer onto poly(tetraflouroethylene-perflourovinyl ether) copolymer film was carried out using gamma irradiations techniques to synthesize graft copolymer membranes PFA-g-PAAc (PFA-COOH). The effect of the irradiation dose on the degree of grafting of AAc onto PFA films was investigated. The results showed that the degree of grafting increases with increasing the irradiation dose. the grafting yield 19, 47 and 73 % of the prepared films [PFA-COOH] were selected for chemical modification by reaction with aniline to produce modified membrane [PFA-CO-NH-ph] followed by sulphonation reaction to introduce sulfonic acid (SO3H) groups to get other modified membrane [PFA-CO-NH-ph-SO3H]. The chemical structures of the grafted and modified membranes were characterized by (FT-IR), (XRD), and (SEM) techniques. It is of particular interest to measure the Ac conductivity of flexible chemical modified membranes as a function of degree of grafting. The modified membranes of the grafting yield 40 and 80 % exhibited AC electrical conductivity. The electrical conductivity increases with increasing the degree of grafting and by chemical modification especially aniline modified grafted films. The electrical conductivity of modified membranes considered for use as semiconductor materials in fuel cell applications.
        Speaker: Mr Naeem El-Sawy (National Center for Radiation Research and Technology (NCRRT), Egypt)
      • 279
        Radiation – Induced Oxidation in Gamma-Irradiated UHMWPE Modified with Hydroxyapatite
        The medical use of ultra-high molecular weight polyethylene (UHMWPE) as the bone replacement as well as the manufacture of sterile sealed cases and envelopes require detailed investigations on the chemical stability over long time wearing. To impart high similarity to substituted hard parts of osseous system, the addition of hydroxyapatite to the polymeric material is an attractive option. The present study investigates three polymer composites consisting of UHMWPE and LDPE to which hydroxyapatite (HAP) was added in the concentration of 10 %. Some of samples were stabilized with rosemary extract powder (0.5 %). Films and flat plates were obtained by melting in a BRABENDER Plastograph, under a mixing temperature of 180°C for 10 min and screws rotation rate of 40 rpm followed by the thermal processing in a laboratory press type POLYSTAT 200 at the following conditions: temperature: 165°C, pressing time 3-6 minutes, pressure of 125-150 atm and cooling time of 30 minutes. Gamma exposure for the accelerated degradation was carried-out in air inside of Ob Servo Sanguis (Hungary) irradiator provided with 60Co source, whose dose rate was 1.1 kGy h-1. The stability and structural characterization were done by isothermal (180 oC) and nonisothermal (heating rate: 10 oC min-1) differential scanning calorimetry in inert and air environments and by ATR-FTIR spectroscopy. The influence of hydroxyapatite and rosemary powder is noticed by the improvement in the kinetic parameters: the decrease of oxidation rates and the extension of total oxidation periods. The progress in the ageing degree is described by the carbonyl index, whose variation is connected to the inhibition promoted by the large surface of hydroxyapatite particles playing the role of adsorbent of free radicals and by the scavenging activity of rosemary components, where the predominant active principle is carnosic acid. In spite of the difference in the behavior of polymeric components relative to the oxidative degradation the evolution of oxidation looks similarly in respect to the accumulation of initiators, hydroperoxyl radicals. The oxidation resistance of studied blends is ameliorated because the both polymeric components are regarded as sources of free radicals, but the addition of hydroxyapatite and rosemary powder makes possible the manufacture of products with long term applications. The contribution of HAP and rosemary additive is significant not only on the early stages of ageing, but also during the exposure to a severe energetic transfer. The efficiency in the oxidation delay in UHMWPE/LDPE blends can be expected when the stress agents are less strong than -radiation. However, the comparative study involving indoor weathering degradation is foreseen, because the oxidation strength of these compositions including hydroxyapatite allows the extension of usage ranges in several areas as outdoor components of industrial devices.
        Speaker: Mr Eduard-Marius Lungulescu (National Institute for Research and Development in Electrical Engineering ICPE-CA, Romania)
      • 280
        Radiochemical Stability and Life Time of LDPE-Based Flexible Composite Filled with Ce-Doped PZT-PbZrTiO3
        The inorganic compounds like mixed oxides doped with certain low amounts of salts play the role of stabilizers for many polymer matrices. This property is related to the crystalline network, where the difference in charge distribution allows the scavenging new formed radicals. During the irradiation of polymers the basic processes involve free radicals. They must not be consumed in parallel reactions as it is occurred in their oxidative degradation. Under this condition, the doped inorganic phase behaves as an antioxidant. Its protection activity is similar to the synthesis antioxidants, which delay the decay of free radicals by their reactions with molecular oxygen. The preparation of Ce-doped PZT – PbZrTiO3 was accomplished by heat treatment at 920 oC for 4 h of lead oxide, zirconia and titania with four concentrations (0.25, 0.50, 0.75 and 1.25 w/w%) of cerium chloride. After milling and drying, the powder was added in low density polyethylene in various proportions (3 and 5 w/w%). The XRD and granulometry on inorganic compound were done for the depicting the morphological state. The films and plaques were obtained by pressing at 175 oC for 5 minutes. Gamma irradiation was accomplished in air at room temperature in Ob Servo Sanguis (Hungary) irradiator provided with 60Co source, whose dose rate was 1.1 kGy h-1. The exposure doses were 25, 50, 100 and 200 kGy which were compared with pristine samples. The stability characterization of modified LDPE samples was performed by FT-IR spectroscopy, isothermal (190 oC) and nonisothermal (heating rate 10 oC min-1) chemiluminescence and thermal analysis. The increasing dependence of protection efficiency on the concentration of dopant in inorganic filler explains the participation of these structural defects at the coupling of oxidizable free radicals. The oxidation state of basic polymer is described by the increases in carbonyl and hydroxyl indexes, which allow the calculation of the radiochemical yields for these degradation products. The stabilization effect is related to the surface activity of powder, whose grain size distribution influences the amplitude of protection. The factors that influence the stabilization activity and kinetic parameters of oxidative degradation are doping degree, the filler concentration and the exposure dose, which determine the interaction probability between solid state defects and free radicals prior their oxidation. The expected stabilization feature is the required feature for the preservation of low oxidation level in many organic products like polymers, paints, vanishes, anticorrosive layers, used in different areas of nuclear units especially nuclear power plants or during their radiation processing.
        Speaker: Mr Traian Zaharescu (Nuclear Agency and Radioactive Wastes, INCDIE ICPE - CA, Romania)
      • 281
        Radiolytical Synthesis and Mechanism of Gold Nanoparticle Formation
        Gold nanoparticles (AuNPs) are widely used in analytical chemistry, biomedicine and catalysis. Reducing agent is very important parameter in the synthesis of AuNPs, however, hypothesis of this study is that AuNPs could be synthesized without using reducing agents, i.e. that due to very low affinity of gold for oxygen AuNPs could be synthesized under highly oxidizing conditions. AuNPs were synthesized in a microemulsion water/TritonX-100/1-pentanol/cyclohexane using various reducing agents: (i) strong chemical reducing agent (NaBH4), (ii) γ-irradiation under moderately strong reducing/oxidizing conditions, and (iii) synthesis under highly oxidizing conditions (with addition of NaOH aqueous solution). All were performed at room temperature (RT). The size, size distribution, aggregation and stability of AuNPs in the microemulsions depend on the strength of reducing agent. When a strong chemical reducing agent NaBH4 was used AuNPs are not well-stabilized and rather polydisperse. Rather small and monodisperse AuNPs were obtained using γ-irradiation (30 kGy; 8 kGy/h). γ-irradition was able to produce AuNPs in air-saturated microemulsions under highly oxidizing conditions. Smaller AuNPs were obtained by irradiation in the presence of N2 in comparison to the air. The γ-irradiation of nitrogen-saturated microemulsion at acidic pH produced AuNPs about 10 nm, which aggregated under isolation by centrifugation. The microemulsion stirred at RT and at pH<7 under oxidizing conditions did not produce AuNPs, while at pH>7 (stronger oxidizing conditions) well-dispersed 12 nm AuNPs were formed. Synthesis of AuNPs in 1-pentanol by adding NaOH aqueous solution at RT without using microemulsions and irradiation confirmed that oxidation of alcohols was responsible for AuNPs formation. Based on these findings we propose the base-catalyzed alcohol oxidation at RT as a new, simple and versatile synthesis route for obtaining gold nanoparticles. In order to further exploit the oxidation of organic molecules for AuNPs synthesis we studied the radiolytical synthesis of AuNPs in the presence of citrate. The γ-irradiation of Au(III)/citrate precursor solutions produced well-dispersed and highly concentrated gold colloids in the presence of dissolved oxygen, without adding any reducing or stabilizing agents. AuNP size can be controlled by saturating gases (air or nitrogen) present in the precursor solution. AuNPs synthesized in the presence of air (10 nm) were approximately two times larger than AuNPs synthesized in the presence of nitrogen (5 nm), as determined by UV-Vis spectroscopy. An easy radiolytical reduction of Au(III)/citrate precursor solution in the presence of dissolved oxygen could be explained by enhanced radiolytical oxidation/decarboxylation of citrate to dicarboxyacetone, acetone and other products. Thus, we confirmed that classical approach of using a reducing agent to synthesize AuNPs is not a determining factor, since diametrically different approach can be used, namely in stimulating the oxidation of organic molecules close to gold ions. However, the mechanism of oxidation of organic molecules during the synthesis is not clear and due to these reasons we introduced NMR spectroscopy in order to study the oxidation products of alcohol and citrate ions during the AuNPs synthesis.
        Speaker: Ms Tanja Jurkin (Ruđer Bošković Institute, Zagreb; Croatia)
      • 282
        Recycled HDPE/Vulcanized EPDM Mixtures Obtained by Irradiation Processes
        Recycling polymers process includes techniques that present solutions to the problem of plastic waste in the environment. This process is important to improve the economic sector in many countries, like cooperative societies. Primary recycling is related to the reuse of plastic waste directly from the production site in the industry, that carry on some advantages besides the low cost involved in the reuse of this waste: the raw material is free from dust of many kinds (metals, different powders and plastics). Among this polymeric waste, packaging dominates this scenario, covering 62.2 % of the total, where polyolefins account more than 50 % of the packaging production. In the same way, the recovering of sulfur cured rubber contribute to release the environment from this almost non-degradable rubber. The goal of this work is to produce an alternative recycled product composed by mixing twenty-times reused HDPE (by primary recycling process) with vulcanized EPDM rubber. The twenty-times recycled thermoplastic was reached by extrusion, which intention was to simulate a polyolefin like a scrap. The EPDM rubber was fragmented and incorporated to the thermoplastic matrix in proportions of 1 % and 5 % w/w, from both kinds of rubber, like received and after a thermal treatment. One of the thermal treatment of rubber consisted in an oven aging in the temperature of 100 oC; the other was a simultaneous heating under irradiation process by electron beam at 130 oC and at 100 kGy absorbed dose (at 22,4 kGy/s dose rate). The final mixture was obtained by injection molding and specimens from injection process were gamma irradiated at 50 kGy and at 100 kGy. Mechanical analysis of stress-strain, infrared FTIR spectra and thermogravimetric degradation were performed to evaluate the final product. The obtained product showed heterogeneous; the rubber without thermal treatment was better incorporated to thermoplastic matrix and the irradiated samples present mechanical resistance that suggests this new material intended to be viable to industrial use.
        Speaker: Ms Jessica Cardoso (Instituto de Pesquisas Energéticas e Nucleares, IPEN - CNEN/SP, Brazil)
      • 283
        Shelf Life Assessment of Sliced Bread by Sorbic Acid Based Active Film
        Food waste and food spoilage is a leading issue facing the world recently. Researchers and industries have made continuous attempts to find out ways to minimize the spoilage by making use of active packaging technologies. The development of active food packaging with antimicrobial functionality enables inhibition of microorganism that caused food spoilage and thus, extends food’s shelf life. Radiation-induced grafting has been used in this study to develop sorbic acid (SA) grafted active film. The SA active film was then use to investigate the performance of sorbic acid (SA) based active film on shelf-life extension of sliced bread. The effectivess of active film against micro-flora formation on bread, moisture content,weight loss, texture and color change was elucidated and discussed. The bread packed with SA active film showed lower in moisture content,weight loss, hardness and color change compared to control. Visual observation of bread packed with SA active film was performed against control film. The SA active film was observed to extend shelf life of bread up to 7 days when compared with the control group, indicating significant reduction of microbial count.
        Speaker: Ms Nor Azwin Shukri (Malaysian Nuclear Agency, Malaysia)
      • 284
        Simultaneous Radiation Grafting of Acrylic Acid on Polypropylene Films: Optimization, Biodegradability and Evaluation of Ecotoxicological Impact
        Abstract Background of the study: Polypropylene (PP) is used as a packaging material because of low cost and water resistance properties. However, it has been much criticized for its lack of degradability. Simultaneous radiation grafting is a versatile method by which acrylic acid (AAc) has been grafted on the surface of PP. From our previous work, it was found that the biodegradability of AAc grafted PP did not significantly improve beyond 34% degree of grafting. Now, there is a need to optimize the grafting condition for ~ 35% degree of grafting, and study the effects of process parameters on it. It is also important to know the ecotoxicological impact of biodegradation product of grafted PP films. Methodology: Simultaneous radiation grafting was done with Co-60 gamma radiation. Experiments were designed based on response surface methodology (RSM) to optimize the monomer concentration (6.88-13.52 wt%), radiation dose (6.74-13.42 kGy), inhibitor concentration (0.01-0.11M) and solvent concentration (0.12-0.36 M) for the 35% degree of grafting. The grafted PP films were characterized by tensile test, fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC) and biodegradability. Ecotoxicological impact was evaluated by microbial test and plant growth (corn and tomato) test as per guidelines of Organization for Economic Co-operation and Development (OECD 208). Results: The number of experiments reduced to 30 only for the optimization of grafting conditions for the 35% degree of grafting. The suggested optimized conditions for 35% degree of grafting were monomer concentration 12.09 wt%, radiation dose 12.40 kGy, inhibitor concentration 0.07 M and solvent concentration 0.12 M, it was also experimetlly verified in triplicate and average degree of grafting achieved was 34%, which is almost same as suggested 35% by the RSM. Grafting of AAc onto PP films was confirmed by FTIR. Tensile strength of PP18 (35% grafted) was 21.1 MPa which is suitable for packaging applications (as against 38.8 MPa of PP). The crystallinity of PP18 (26%) was lower than PP (59%) shown by DSC. The biodegradation achieved was 5.5% at 35% degree of grafting by following the guideline of American Society for Testing and Materials (ASTM D 5338-11) shown in Fig 1. Ecotoxicological test indicated that biodegradation products were non-toxic in nature. Conclusion: Grafting conditions were optimized by RSM for 35% degree of grafting and experimentally verified. Biodegradation 5.5% was achieved with 35% grafted PP film. Eco-toxicological test confirmed that no degradation product of grafted PP has any environmental toxicity. Keywords: Polypropylene films; Radiation grafting; Response surface methodology; Biodegradability; Ecotoxicological impact
        Speaker: Mr Haripada Bhunia (Department of Chemical Engineering, Thapar University, Patiala, India)
      • 285
        Sorption of Iodine on Ion Exchange Resins
        Sorption of iodine on ion exchange resins N.H.Kamel, M.R.Shehata, N.S.Farahat One of the most important applications of radiation in the field of chemistry is the modification of polymeric species for the purpose of separation and purification of radioactive species is radiation induced graft polymerization (RIGP) and Emulsion polymerization both in which various factors affect the polymerization process most important of which is the radiation dose. The monomer Glycidyl methacrylate has been polymerized by Radiation induced graft polymerization on polyethylene tubes with optimum solvent concentration, radiation dose, radiation time, and also GMA has been polymerized by radiation emulsion polymerization influenced by the irradiation dose rate and the type of emulsifier namely TWEEN 80 in this study. The GMA is a significant monomer due to the presence of the epoxy group which can further modified for purpose of ion exchange. Ion exchange is the optimum technique for treatment of radioactive wastes and or purification of produced radioactive isotopes especially for medicinal uses, so the development of lost cost ion exchange resins that are capable of adsorbing ions in interest from high volumes of effluent on the least amount of adsorbent with high adsorption capacity and low amount of solid waste. Radioactive isotope production facilities have been established all around the world for manufacturing of radioisotopes for pharmatheutical uses either by neutron activation or by fission of uranium as molybdenum 99, Technicium 99m and iodine 131. The PolyGMA prepared by both techniques was modified using triethyl amine for embedding with tertiary amino groups for acting as an anion exchanger for purification of iodine 131 produced from other fission products. A comparative study for the adsorption of iodine 131 in the form of iodide between the synthesized resins and four commercial anion exchange resins namely (Biorex 5,Dowex 1-8x (20-50 mesh), Dowex 1-8x (100-200 mesh) and Dowex 21 )by the radiotracer technique using radioactive iodine 131 manufactured locally, Characterization of different stages of anion exchange was performed by Fourier transformation infra red and scanning electron microscope incorporated with EDX, Scanning electron microscope and EDX image of Poly GMA in iodide form Conclusion: The poly GMA prepared by TWENN 80 so no adsorption for radioactive iodine, while the poly GMA prepared by radiation induced graft polymerization on polyethylene tubes showed adsorption of about 30% which was verified with infra red and scanning electron microscope and EDX all resins obeyed the pseudo second order rate of reaction indicating chemical sorption of iodide ions, and obeyed Langmiur and Freundlich equations.
        Speaker: Ms Noha Farahat (Egyptian Atomic Energy Authority, Egypt)
      • 286
        Structural Characterization, Antibacterial Properties and Citotoxicity of $\gamma$-Irradiation Synthesized Ag-poly(N-isopropylacrylamide/itaconic acid) Hydrogel Nanocomposites
        Silver (Ag) impregnated dressings are intended to promote healing, prevent infection, to produce a sustained, steady supply of active Ag and to meet the challenges about safety. Hydrogels impregnated with nanocrystalline Ag (AgNPs) have the potential to meet most of these requirements. Here hydrogel nanocomposite formulations are based on thermo- (NiPAAm) and pH-sensitive (IA) copolymer hydrogel matrix doped with AgNPs, (Ag-P(NiPAAm/IA), as a system for the controlled release of therapeutically active Ag ions with the aim to obtain the effective smart, antibacterial and nontoxic device. Synthesis of cross-linked polymer matrix (hydrogel) and in situ incorporation of AgNPs is made by biocompatible radiolytic products of water (using a $^{60}$Co source) which provides a basis for the wide range of advanced or innovative applications in the biomedical field. The aim of the work was to investigate structural characteristics of the AgNPs, the micromorphologycal and physicochemical characteristics of hydrogel, and biomedical potential of $\gamma$-irradiation synthesized nanosystems. FTIR analysis confirms formation of 3D structure of copolymeric hydrogel with thermo- and pH responses. Swelling experiment was performed at different temperature ($25^\circ$C and $37^\circ$C) and pH ($2.2$, $4.5$ and $46.8$) values. Internal morphology, examined by SEM and micro-CT analysis, showed the porous structure, dependent on the IA content, while AgNPs have no influence on the micro-structure. UV-Vis confirmed the synthesis of spherical AgNPs by the peak at around $400$ nm. XRD studies confirmed the face centred cubic (fcc) crystal structure of AgNPs with the diffraction maxima at $2\Theta$ angle values that correspond to the Bragg reflections from the crystal planes $(111)$, $(200)$, $(220)$ and $(311)$. The changes of lattice parameter, interplanar spacing, strain, stress, and dislocation density of crystalline AgNPs depend on the pore size and the diameter of AgNPs. The controlled release of active substances was monitored by the release kinetics of Ag ions in a buffer solution (pH${=} 7.4$, $T=37^\circ$C). The content of Ag ions was determined by Argon arc plasma and obtained results are modelled by pharmacokinetic models (Korsmeyer-Peppas, Higuchi, Hixson-Crowel, Kopcha and Makoid-Banakar). Antibacterial potential against the gram-negative (*Escherichia coli*) and gram-positive (*Staphylococcus aureus*) bacteria was investigated by the disc diffusion and optical density methods. Considering that the basic condition for the biomedical application of these types of materials is absence of toxicity in the surrounding tissue, cytotoxicity of synthesized nanocomposite device was examined by the effect on HaCaT cell line (healthy human keratinocytes). The results show that it is possible to achieve and fine-tune optimal antibacterial activity, below the cytotoxicity level, and without any harmful effects on the surrounding cells.
        Speaker: Ms Zorica Kačarević-Popović (Vinča Institute of Nuclear Sciences, University of Belgrade, Serbia)
      • 287
        Studying the Biological Efficacy of Radiation-Treated Radiolabeled DOTA-Bombesin-Decorated Nanoconstructs as Potential Nanosized Drug Delivery Systems
        **Aim:** The over-expression of neuropeptide receptors in human breast or prostate cancer leads to potential application of these peptides as new generation of agents for cancer diagnosis and therapy. In this study, we have developed 177Lu-labeled bombesin (BBN) based albumin nanoparticles (Alb-NPs) and papain nanoparticles (Pap-NPs), thus resulting highly specific radiolabeled nanoconstructs decorated with DOTA-BBN, and used as emerging novel ‘nanotheranostics’ for pre-clinical imaging. The synthesis of gold nanoparticles was developed by the use of green technology, through the stabilization with natural gums (Arabinoxylan - AX isolated from ispaghula seed husk). **Methods:** As a part of IAEA CRP, the albumin nanoparticles (Alb-NPs) were prepared in Argentina while papain nanoparticles (Pap-NPs) were prepared in Brazil by ionizing radiation cross linking. Particle size of Alb-NPs was tailored by changing the water/ethanol ratio in the protein solution, reaching particles in the range of 20 nm to 40 nm. The biological efficacy of DOTA-Bombesin-(Alb-NPs) was tested in Pakistan after labeling with 177Lu. The quality control was performed by using ITLC-SG strips as stationery phase. There was a good separation with radiochemical purity (RCP) of 97.3 %. The biological efficacy of 177Lu-DOTA-Bombesin-(Alb-NPs) was tested by determining *in vivo* uptake through imaging scintigraphy in normal rabbit models and biodistribution in normal mice. A solution of 177Lu-AlbNPs-DOTA-Bombesin (2 mCi ml-1) was injected intravenously into the ear vein of rabbits (n = 3). Dynamic study acquisition comprised of 10 frames of 60 sec each. It was followed by anterior and posterior whole body Static images acquired at 15 min, 24h, 48h, 72h, and 96h, post injection. All of these protocols have been established and are further applied to novel bombesin-derivatized (radiation-treated) nanoconstructs from other partner labs. **Results:** Radiolabeling and quality control was established for 177Lu-Alb-NPs-DOTA-Bombesin. The effect of activity on labeling efficacy was studied by varying the amount of activity from 5 mCi to 30 mCi by keeping all parameters constant. Similarly, the effect of volume over labeling efficacy was studied by varying the amount of volume from 10 to 200 µl. The maximum labeling efficacy was found at 10 µl and beyond 50 µl, the solution became turbid. Regarding imaging scintigraphy in normal rabbit models, immediately after the injection of radiolabeled nanoconstruct, activity was observed to form the blood pool that was visible in dynamic study of 15 min. In static images, it was further observed that the compound showed a slower uptake with a significantly higher retention time in liver and spleen, thus leading to sufficient renal excretion to allow absorption of the labeled compound into tumor, with rapid body clearance. **Conclusion:** In summary, this approach might be further extended to tumor-specific targeting by using BBN derivatives as carrier of chemotherapeutic agents. Imaging studies performed with 177Lu-Alb-NPs-DOTA-Bombesin demonstrate its ideal therapeutic potential to be further developed as a feasible theranostic agent, during this CRP.
        Speaker: Mr Irfan Ullah KHAN (Institute of Nuclear Medicine & Oncology (INMOL), New Campus Road, Lahore-54600, Pakistan)
      • 288
        Swelling and Drug Release Kinetics of Polyacrylamide/Sodium Alginate Copolymer Hydrogels Synthesized by Gamma Irradiation
        Hydrophilic hydrogels based on different ratios of polyacrylamide (PAAm) and sodium alginate (AG) were synthesized by gamma irradiation in aqueous solutions. The pH-sensitive character of PAAm/AG hydrogels was investigated in a wide range of buffer solutions of different pH values (2-8). The pH-sensitive character of PAAm/AG hydrogels was utilized for the possible use in drug delivery; the release profiles of chlortetracycline and ketoprofen, as drug models, was investigated. The swelling and release were further analyzed by Ficks power law equation, and the possible mechanisms of the water diffusion and release were suggested. The hydrogels were characterized by different techniques; FT-IR spectroscopic analysis, swelling, drug release measurements and kinetics of drugs Release Results and discussion Release of tetracycline The drug release from loaded PAAm/AG hydrogel films, in different buffer solutions of pH 2.0, 5 and 8 was studied. Clearly, it can be seen that the drug release from loaded films is very sensitive to the pH of the medium. The release was increased by increasing the pH values depending on hydrogel composition. The high the ratio of AG in the hydrogel composition, the lower was the release. The results were in consistent with the water swelling ratio of non-loaded PAAm/AG hydrogel films in different pH values. As the amount of COO− on alginate is almost equivalent to the amount of NH3+ on PAAm, in the blank matrix film at pH 2.0, the macromolecular chains in the film matrix attract each other inducing a shrink in this system. So, the value of water swelling ratio of blank matrix film was the lowest at pH 2.0. When the equilibrium between the amount of COO− and NH3+ was broken at high pH, the chains macromolecules of the film matrix toke each other apart, increasing the water swelling ratio of the film and accelerating the drug release. Release of Ketoprofen Ketoprofen is a non-steroidal anti-inflammatory drug and it has a pKa of 4.94. The chemical name for ketoprofen is 2-(3-benzoylphenyl)-propionic acid. When this drug is loaded onto the networks of PAAm/AG hydrogels, it will be reacted through hydrogen bonding inside the network structure of hydrogels. These hydrogen bondings are through the COO- of AG molecules and those on chemical structure of ketoprofen.. For both hydrogel compositions, ketoprofen released rapidly at first and then gradually reached equilibrium release at ~ 3 h depending on the pH of medium. The equilibrium release of ketoprofen from PAAm/AG hydrogel (50/50%) is much higher than the release from PAAm/AG hydrogel (80/20%) and 50/50%, irrespective of the pH value. Opposite trends were found in the case of the release of tetracycline drug at similar conditions. Conclusion In this study, films of a new pH-sensitive copolymer hydrogel based on polyacrylamide (PAAm) and sodium alginate (AG) was successfully prepared by gamma radiation in the form of interpenetrating polymer networks (IPN). The pH-sensitivity of hydrogels affects the drug release
        Speaker: Ms Horia Nizam El-Din (National Center for Radiation Research and Technology, Atomic Energy Authority, Egypt)
      • 289
        Synthesis and Characterization of PP Films Rich in Primary Amines for Cell Cultures, by Gamma Radiation
        Development of biomaterials have been increased, due the necessity to find bio-inert materials able to present a specific cellular response. Biomaterials are very important for tissue engineering. They can be used as bridges to regenerate damaged tissue growth, as well as support for immobilized biomolecules (drugs, fungicides, enzymes, etc.). Polymer surface modification can be carry out by incorporating functional groups on polymeric materials for the appropriate cell adhesion. It is well known that hydrophobic polymeric surfaces cannot add cells, however, hydrophilic surfaces, mainly rich in nitrogen, facilitate the adherence. The amine functional groups (-NH2) are one of the most important for cells and protein adhesion. Nowadays, the modification can carry out by physical or chemical methods. One of this methods is plasma surface modification, even though is the more common, the systems synthesized are partly soluble in water, besides the formation of a great amount of free radicals, which generate the incorporation of oxygen when is in contact with the air. To overcome this problem, the modified films were synthesized by gamma radiation in two step method. In this work, radiation grafting of acryloyl chloride onto polypropylene (PP) has been applied to insert carboxyl functionalities on PP; and then, the radiation grafted films were reacted with some diamines. Amine concentration was determined and after a period of time, the effect of aging on the amine functional groups was determined by derivatization with 4-trifluoromethyl benzaldehyde (TFBA), and subsequently characterized by XPS ( N/N/C ratios), ATR-FTIR and contact angle. Acknowledgements: the authors thanks to M.Cruz, and A. Ortega for technical support and DGAPA UNAM Grant IN200116 for financial support.
        Speaker: Ms Mitzi Paulina Pérez-Calixto (Instituto de Ciencias Nucleares UNAM, ICN/UNAM, Mexico)
      • 290
        Synthesis by Gamma Radiation and Characterization of Poly(Vinylpyrrolidone) Nanogel
        The synthesis of Polyvinylpyrrolidone (PVP) nanogels by ionizing radiation techniques (gamma irradiation), for their evaluation as potential system of drug delivery was the aim of this research. Solutions were prepared with water purified by distillation and in order to remove any dust particles and/or polymer aggregates, solutions were filtered subsequently through filters of 0.45 and 0,22 um pore size. Gamma irradiation was carried out with a panorama 60 Co source at dose ranging from 5 to 25KGy. Particularly, the polivynilpirrolidone nanogels can be obtained by gamma radiation, based not on polymerization, but on intramolecular crosslinking of polymers chains, in aqueous solutions. The nanogel characterization was performance by electron microscopy (TEM, SEM), DRX, spectroscopy (UV-visible and IR), light scattering, viscosimetry, delivery of an active agents and cytotoxicity trials The results showed that in dependence on the polymer concentration and the rate dose two different crosslinking reactions can take place. Irradiation experiments at room temperature in diluted solution with further increasing of the radiation dose lead to the formation of PVP nanogels due to an intramolecular crosslinking reaction. By using both light scattering and TEM the PVP nanogels were measured, these showed a size distribution of 50.10 nm. They have lots of advantages over conventional systems since they enhance the delivery, extend the bioactivity of the drug by protecting them from environmental effects in biological media, show minimal side effects, demonstrate high performance characteristics, and are more economical since minimum amount of expensive drugs are used.
        Speaker: Mr Yuri Aguilera-Corrales (Higher Institute of Technologies and Applied Sciences, Cuba)
      • 291
        Synthesis of Crosslinking Films Based of 3-(Trimethoxysilyl) Propyl Methacrylate Silanized Xantham Gum/Lignin and their Crosslinking by Gamma Radiation, to Potential Application and Films Packing
        The production of biodegradable and edible films based on biopolymers has attracted attention and represents one of the most advanced challenges in the field of food packaging and coating. Polymers derived from natural products offer the greatest opportunities as component of edible films since their biodegradability and environmental friendly [1]. Xanthan gum has been used in a wide variety of foods (in many low fat food systems due to its water binding capacity) for a number of important reasons, including emulsion stabilization, temperature stability, compatibility with food ingredients and its pseudoplastic rheological properties [2]. Xanthan gum is classified E 415 in the European List of Permitted Food Additives. According to JECFA (Joint WHO/FAO Expert Committee on Food Additives), it has the status of ADI-nonspecified (Acceptable Daily Intake), i.e., no quantitative limitation is stated, and, as such xanthan gum is recognized as a non-toxic additive for human consumption. Lignin, a natural biopolymer, mostly derived from wood, is an enormous and renewable reservoir of latent polymeric materials and aromatic chemicals. Due to their very complex structure, lignins are amorphous polymers with rather limited industrial use. They are usually seen as waste products of pulp and paper industry and often used as fuel for the energy balance of the pulping process [3]. Unfortunately, the use of biopolymers as food packaging materials has drawbacks such as poorer mechanical, thermal, and barrier properties as compared to the conventional non-biodegradable materials made from petroleum. The incorporation of nanofillers such as silicate, clay, and titanium dioxide (TiO2) to biopolymers may improve not only the biopolymers’ mechanical and barrier properties but also offer other functions and applications in food packaging such as antimicrobial agent, biosensor, and o xygen scavenger [4]. In this work, the xanthan gum/lignin mixture was silanized with 3-(trimethoxysilyl) propyl methacrylate, and consequently crosslinking by gamma radiation. The best conditions to prepared hybrid biofilms were 95/5 ratio of xanthan gum/lignin, 5 % wt. of organosilane at 20 kGy at 5 kGy h-1 of dose and dose rate respectively. By FTIR-ATR and NMR spectroscopy was possible confirm the silanized reaction. The morphological aspect and size dimension were determined by SEM and TEM. The thermal behavior was analyzed by DSC and TGA. References: 1. N. Akdeniz, S. Sahin, G. Sumnu. Journal of Food Engineering 75 (2006), 522–526. 2. F. Jiangyang, W. Kang, L. Meimei, H. Zhimin. Carbohydrate Polymers 73 (2008), 241–247. 3. J.K. Saini, R. Saini, L. Tewari. 3 Biotech 5 (2015), 337–353. 4. J.W. Rhim. Carbohydrate Polymers 86 (2011), 691-699.
        Speaker: Ms Lorena Garcia-Uriostegui (Departamento de Madera Celulosa y Papel-Universidad de Guadalajara, carretera Guadalajara-Nogales Km. 15.5, Zapopan, Jalisco 45110, Mexico.)
      • 292
        The Effect of NAtural Antioxidiants in Thiyl Radical-Induced Lipid Modification Processes
        **Background of the study.** Polyunsaturated fatty acids (PUFA), major constituents of biological membranes are sensitive to a free radical attack. The reactions of PUFA with free radicals are known to occur via two main processes: (i) lipid peroxidation and (ii) *cis–trans* isomerization. Lipid peroxidation can be inhibited by thiols, due to their H-donation ability. On the other hand, thiyl radicals are known to catalyse the double bond isomerization in PUFA. Both processes have damaging potential that must be carefully considered for its consequences in a biological systems. Therefore, the protection against lipid degradation under oxidative and free radical conditions is of special interest. The aim of this study is to elucidate the influence of different naturally occurring antioxidants on lipid peroxidation and *cis–trans* isomerization processes in biomimetic model system under different conditions. **Methodology.** Model system containing mixed surfactant micelles and buffer was prepared by slow solubilization of linoleic acid (LH) in non-ionic surfactant micelles previously formed by mixing Tween®-20 and PB, pH 6.5. The composition of the investigated systems was typically 0.5 mM LH, 0.28 mM Tween®-20 and 5 mM PB (pH ~ 5). Ascorbic acid (AscH), α-tocopherol (α-TOH) and resveratrol (ResOH) of defined concentrations were added during preparation of model systems. The addition of the amphiphilic 2.8 mM 2-mercaptoethanol was added to previously prepared micelles just before irradiation. Model lipid systems were irradiated up to the dose of 400 Gy, in equilibrium with air or after saturation with N2O at room temperature using panoramic 60Co source at the Ruđer Bošković Institute. Accurate dose rates in the irradiating positions were established with the ethanol-chlorobenzene dosimetry system (ISO/ASTM 51538:2009). The concentrations of hydroperoxides of linoleic acid were determined by the spectrophotometric ferric thiocyanate method, and the geometrical isomerization of LH methyl ester was studied by capillary gas chromatography. **Results.** Under air-equlibrated conditions the addition of different natural occuring antioxidants retarded the process of lipid peroxidation among which ResOH showed the best antioxidative property. In model systems where process of *cis–trans* isomerization prevailed, the presence of antioxidants influenced on a decrease of the *trans* isomerization level; AscH was the the most effective inhibitor of radiation-induced *trans*-isomer formation. Among the natural compounds analyzed in this work an amphiphilic ResOH has proven to be the most effective antioxidant, also significant inhibitor for *cis–trans* isomerization process at the low formation rate of initial radical species. **Conclusion.** Results indicate that the *cis–trans* isomerization and lipid peroxidation processes level could be dependent on the hydrophilic/lipophilic properties of particular antioxidant and its localization in model lipid system. This study contributes to the understanding of the role of antioxidants in radical processes which are not only able to prevent peroxidation but can also behave as anti-isomerizing compounds.
        Speaker: Ms Ivana Tartaro Bujak (Ruđer Bošković Institute, Croatia)
      • 293
        The Effect of Radiation Environment on Electrical Insulation Materials
        Due to recent renewed interest in reactor safety and many reactors approaching end of useful lifetime, emphasis on durability of power and instrumentation electrical Insulating Materials is growing. While current materials have shown suitable radiation tolerance in lab testing, combined effects of radiation, temperature, and water at normal or abnormal conditions have led to cable failures. Effects of radiation types and dose rates on selected cable insulating materials have been studied. Effects of dose-rate temperature during radiation on service endurance are considered. Dielectric materials used to fabricate various parts of electrical equipment systems, nuclear and electronic devices often operate in ionizing radiation fluxes, problems of radiation resistance and changing of insulating materials and devices are urgent. It is necessary to develop ways to improve the radiation resistance. Radiation damage to dielectric and insulating materials is a function of temperature and atmospheric conditions as well as the radiation environment. Many materials are more resistant to radiation in the absence of oxygen or moisture and at lower temperatures. Because of this influence of environmental conditions it is impractical to attempt to compile detailed information that would be directly applicable to all circuit requirements and environmental conditions. The fabrication method used by the manufacturer can also be a factor in the amount of damage that occurs from radiation. Both temporary and permanent changes occur in the characteristics of organic insulating and dielectric materials as a result of exposure to a radiation environment. Enhancement of the electrical conductivity is the most important of the temporary effects with increases of several orders of magnitude being observed. The conductivity increases exponentially in response to ionizing radiation until it reaches equilibrium at a value that is determined by the rate of exposure and ambient temperature for a specific material. Following the termination of the irradiation the induced conductivity gradually decreases. Other temporary effects, in addition to the enhanced conductivity, are a reduction in breakdown and flashover voltages, increases in AC loss characteristics, and variations in dielectric constants. These changes in electrical characteristics, however, are often not large enough to prevent the use of the insulators in a radiation environment, particularly if allowances are made to minimize their effect on the circuits’ performance. Permanent effects of radiation on organic insulating materials are normally associated with physical changes, including decreases in hardness, tensile strength and melting point, and greater solubility. This physical degradation in the advanced stages is disastrous in that the insulating material breaks, crumbles, or powders thus losing structural integrity and causing failure. Changes in dissipation factor and insulation resistance have also occurred as permanent effects, but they are normally quite small and offer few problems except in the most uncommon applications. A comparison of the relative radiation resistance of organic insulating materials to permanent effects is presented. Gas evolution, a secondary reaction that occurs when organic insulators are irradiated, is a problem because of pressure build up in confined enclosures.
        Speaker: Mr Ezzat Eisawy (Nuclear and Radiological Regulatory Authority, Egypt)
      • 294
        The Hormetic Effect of of X-rays on Biosynthesis of Gold Nanoparticles by Actinobacteria.
        Background: Gold nanoparticles (GNPs) play an important role in medical, health and environmental applications. All kinds of microorganisms were found to be able to synthesize GNPs. This study assesses the enhancing effect of low-level X-rays on the biosynthesis of GNPs by Actinomycetals isolated from Angouran mine in Zanjan province in North West of Iran. Methodology: The isolated Actinomycetes were grown aerobically in MGYP broth media. The cultures were centrifuged and the harvested bacteria were suspended in 50 mL aqueous HAuCl4 in 12 Erlenmeyer flasks in 3 groups of 4. Two groups of samples were irradiated by 30mGy and 5mGy X-rays. The third group was considered as control without any radiation. The solutions were shake- incubated for 120 h. Results:After 5 days, the color of first group samples were changed from milky to purple, while the color changing occurred after 10 days in the 2nd group samples and the control samples. The UV-vis absorption spectrometry of the irradiated aqueous medium by 30 mGy X-rays confirmed the formation of GNPs. Conclusion: The findings showed that 30 mGy ionizing radiation stimulated the microorganism to form GNPs in a half time in comparison to other groups.
        Speaker: Ms Faranak Saghatchi (Zanjan University of Medical Sciences, Iran, Islamic Republic of)
      • 295
        γ-Ray Induced Reduction and Modification of Graphene Oxide
        Graphene has attracted increasing attention due to its striking electronic, mechanical and thermal-conducting properties. Up to now, graphene has been produced by numerous techniques such as micromechanical exfoliation of graphite, chemical vapor deposition, epitaxial growth and the reduction of graphene oxide (GO). Among these, the reduction of GO by γ-ray irradiation has been regarded as the most green, facile and economical method of the large-scale production of graphene and graphene-based composites. A series of graphene were prepared by γ-ray induced reduction of GO suspension in different solvents, such as H2O, alcohol, ethylene glycol, N, N-dimethyl formamide (DMF), N-methylpyrolidone (NMP) and p-phenylene diamine (PPD) aqueous solution. Thermogravimetric analysis (TGA), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD) were used to study the structure of GO after γ-ray irradiation. The results show that GO in these solvents were all reduced. Alkyl groups are attached onto the reduced GO (RGO) in alcohol or ethylene glycol solution due to the recombination of radicals. Besides, the protonated amine groups which generated from the radiolysis of DMF, NMP and PPD are interacted with residual COO- groups on the edge of the as-synthesized RGO with the driving force of electrostatic interaction. This work provides a new approach to obtain different graphene.
        Speaker: Ms Hui-Ling Ma (Beijing Research Center for Radiation Application, China)
      • 296
        γ-Ray-Radiation-Scissioned Chitosan as a Gene Carrier and its Improved in vitro Gene Transfection Performance
        Chitosan (CS) has long been expected to be an ideal gene carrier for its high biosafety.[1] However, the low transfection efficiency of the raw chitosan-based vector has long been a problem troubling the researchers in medicine due to its poor water solubility, low electric charge density, dissociation problem, and other disadvantages.[2] In this work, CS with low molecular weight (MW) were prepared through the γ-ray radiation on the acetic acid solution of CS. The CS chains were scissioned under the γ-ray radiation. When the absorbed dose was above 30 kGy, the MW decreased about an order of magnitude, i.e. from the original 3.5 × 105 g·mol-1 to 9.0×104 g·mol-1 (30 kGy) and 5.0×104 g·mol-1 (50 kGy). The γ-ray-radiation-scissioned CS can effectively bind with plasmid (pEGFP) through complex coacervation method, forming pEGFP/γ-ray-radiation-scissioned CS complex particles with a size of 200 ~ 300 nm. The complex particles has a good stability and little cytotoxicity. The γ-ray-radiation-scissioned CS can protect pEGFP from being digested by DNase I according to the gel electrophoresis analysis. The in vitro gene transfection efficiency of the pEGFP/γ-ray-radiation-scissioned CS complex particles were investigated by fluorescence microscope and flow cytometry. The results showed that the gene vectors using γ-ray-radiation-scissioned CS as the carrier will possess better gene transfection efficiency than those using natural high-MW CS as the carrier. The higher the absorbed dose, the smaller the MW of CS and the better transfection efficiency of the corresponding gene vector. This work provides a green and simple method on the preparation of CS-based gene vectors with high efficiency and biosafety. [1] J.M. Dang, K.W. Leong, Advanced drug delivery reviews, 2006, 58, 487. [2] S. Mao, W. Sun, T. Kissel, Advanced drug delivery reviews, 2010, 62, 12.
        Speaker: Ms Mozhen Wang (Department of Polymer Science and Engineering, University of Science and Technology of China, China)
    • 16:15
      Coffee break
    • A13: Advanced Nano Materials IAEA Board Room B/M1

      IAEA Board Room B/M1

      Advanced Nano Materials

      Conveners: Mr Piotr Ulański (Institute of Applied Radiation Chemistry, Faculty of Chemistry, Lodz University of Technology, Lodz, Poland), TSec Agnes Safrany
      • 297
        Radiation Synthesis of Nanosized Drug Delivery Devices
        The radiation chemistry of polymer aqueous solutions is a successful synthetic methodology for large scale production of nanosized drug delivery systems. That is particularly true for nanogel drug carriers. Nanogels are fascinating nanoparticles that, for their tunable chemical structure and swelling ability by water molecules, can be designed to be biocompatible, to offer conformable cavities to incorporate bulky therapeutic proteins, but also small hydrophobic pockets to host barely polar molecules, which is the case of most medical drugs. They can display reactive groups to conjugate targeting ligands, such as monoclonal antibodies, peptides and oligonucleotides. These nanoparticles can be used to target specific cells and cellular microenvironments with high specificity and affinity. They can also incorporate chelating agents that bind radioactive ions, either for bio-imaging or therapeutic purposes. The possibility of producing nanogels as aqueous dispersions, without going through a drying step for purification since no recourse to organic solvents and surfactants is made, is the best guarantee for preserving their size, hence functionality. Water radiolysis provides a means of generating initiating radicals at the desired rate. These radicals can either recombine or react with the polymer solute, transforming the otherwise chemically inert macromolecule into multi-radical species. Radicals formed on the polymer can either react with molecular species present or formed in solution, or combine with other macroradicals. Intramolecular combination creates permanent loops and crosslinking points within the same chain, transforming the linear or branched polymer chain into a nanoscalar network. Intermolecular combination, binding polymer chains together, contributes to increase the nanogel size and molecular weight. By tuning the irradiation conditions we expect to be able to tailor both particle size and chemical composition. In order to establish relevant process–structure–property relationships, irradiations are performed with pulsed electron beams varying the irradiation conditions and system composition. The efficiency of the polymer in scavenging the initiating radicals is estimated. The produced nanogels are characterised for their composition and particle size. The possibility of generating nanogels with controlled hydrodynamic diameter in the range from 20 to 200 nm and relatively narrow particle size distributions (PDI<0.3) is demonstrated. Irradiation conditions that favour intra-molecular crosslinking are identified, the most important parameter to control being the polymer molar concentration. Functional groups are generated on the polymer by the reaction of some macroradicals with molecules that may be produced in situ by irradiation (e.g. H2O2, O2) or purposely added to the system (unsaturated monomers). These groups are used to bind therapeutic biomolecules, that can be protected by the nanogel from degradation when in solution and be exposed to their receptors when the nanoparticles experience a change in their microenvironment (e.g. at the cell membrane). The easy of manufacture and purification of the base nanogels, the possibility to use them as substrates for different therapeutic strategies by attaching specific ligands and drugs, and their properties when evaluated in relevant cellular and animal models represent today a very promising prospect for translation into clinic.
        Speaker: Ms Clelia Dispenza (Università degli Studi di Palermo, Italy)
      • 298
        Protein-Based Nanoparticles Prepared by Radiation-Induced Cross-Linking
        The powerful of ionizing radiation of electron beam or gamma sources to crosslink polymers has been largely demonstrated. Preparation of crosslinked hydrogels for wound dressing by this technique has important advantage to other chemical process. In addition, ionizing radiation technology has the ability to generate intermolecular or intramolecular crosslinking. Conversely, for several decades have been demonstrated that irradiation of protein solutions generates mainly degradation products. Only protein solutions in frozen state can be sterilized by gamma rays avoiding protein degradation. Low amounts of polar solvents can be added to protein solutions without produce denaturation. By Dynamic Light Scattering (DLS) it is possible to follow the protein aggregation process in solution; however this effect is reversible. In this work, novel methods of Albumin NPs (Alb NPs) and core/shell gold/Albumin NPs (Au/Alb NPs) preparations are shown by radiation induced crosslinking. Albumin dissolved in ethanol/water solutions were irradiated with ionizing radiation sources (gamma rays or electron beam). In both cases NPs were obtained after irradiation with at least 2 kGys [1,2]. NP size can be modulated with the ethanol concentration. In the same way, core/shell Au/Alb NPs has been prepared by a similar technique. In this case a multilayer of crosslinked Albumin coated the Au NPs. NPs were characterized by different techniques such as DLS, UV-visible and infrared spectroscopy, transmission electron microscopy and atomic force microscopy. NPs sizes were in the range of 20-40 nm for Alb NPs and 60-80 nm for Au/Alb NPs. In the last case, TEM images showed that the NPs have spherical shape and the presence of a low-density halo around the metal core confirms the presence of Albumin. Using an antigen-antibody recognition analysis was able to demonstrate the biospecificity of the NPs surfaces. References [1] Espinoza, S. L. S., Sánchez, M. L., Risso, V., Smolko, E. E., & Grasselli, M., Radiation synthesis of seroalbumin nanoparticles. Radiat. Phys. Chem., 81 (2012), 1417-1421. [2] Achilli, E., Casajus, G., Siri, M., Flores, C., Kadłubowski, S., Alonso, S. D. V., & Grasselli, M. Preparation of protein nanoparticle by dynamic aggregation and ionizing-induced crosslinking. Coll. Surf. A, 486 (2015), 161-171.
        Speaker: Mr Mariano GRASSELLI (Universidad Nacional de Quilmes - IMBICE (CONICET), Argentina)
      • 299
        Molecular Design and Synthesis of Different Polymer-Based Nanoparticles as Nanocarriers Using Irradiation Techniques
        Significant progress has been made during the past decade in preparing
polymer-based nanoparticles (NPs) as nanocarriers for a wide range of applications. One of the next
critical challenges is developing a green, robust and versatile method using irradiation techniques which allows
the synthesis of different polymer nanoparticles into functional structures tailored for each specific
purpose. In this work, we proposes the molecular design and irradiation-assisted synthesis for the creation of polymer-based nanostructures, i.e., amphiphilic polymer core-shell NPs, inter-polymer complex NPs, polymer-capped metal NPs and hydrid NPs to be applied as nanocarrier for drug delivery, agrochemical entrapment, paint and coating additives. According to the different molecular structures, radiation-induced degradation, grafting and polymerization were carried out in particular water-based system at room temperature. Gamma rays and electron beam irradiation doses ranging from 5 to 100 kGy were selected and controlled to achieve nanocale structure with the size of 10-300 nm. The amphiphilic core-shell water-soluble chitosan NPs (~120 nm) could encapsulate Berberine and Paclitaxel anticancer drugs with the drug content of 37% (w/w). Chitosan-polyacrylic acid interpolymer complex NPs (54 nm) efficiently entrap 20% (w/w) ammonium nitrate fertilizer and exhibit pH responsive function. Gold nanoparticle (5-50 nm) was successfully green synthesized in the water-soluble chitosan (WSCS) produced from radiation-induced degradation. In addition, electron beam can also accelerate the production of AuNPs in WSCS. The polymer brush shells were grafted onto silica NPs and silver NPs (5 nm) were then constructed on the polymer brush-grafted-silica NPs (98 nm). The obtained hybrid NPs effectively inhibited the growth of building fungi, i.e., *Spergillus Niger* and *Syncephalastrum Racemosum*. All types of polymer-based nanoparticles with different functions were successfully designed and prepared using irradiation techniques.
        Speaker: Ms Wanvimol PASANPHAN (Department of Materials Science, Faculty of Science, Kasetsart University, Thailand)
      • 300
        Green Nanotechnology in Nuclear Medicine—Tumor Specific Radioactive Gold Nanoparticles for New Approaches in Cancer Therapy
        We report herein, for the first time, on the application of Mangiferin—a glucose functionalized xanthanoid found in abundance in mangoes peel—as a tumor targeting agent for the selective delivery of inherently therapeutic radioactive gold nanoparticles (Au-198) into prostate tumors in mice. Mangiferin functionalized radioactive gold nanoparticles (MGF-198AuNPs) have been synthesized and fully characterized for their potential applications in tumor therapy. The highly innovative feature of this green nanotechnology focused work is the ability of Mangiferin to serve dual roles of chemical reduction, to produce gold nanoparticles, with subsequent encapsulation to afford in vivo stability and tumor specificity. Laminin receptor specificity of Mangiferin affords site specific accumulation of optimum therapeutic payloads of this new therapeutic agent within prostate tumor cells (PC-3) of human prostate tumor origin. Over expression of laminin receptors in human prostate tumors and the selective affinity of Mangiferin toward such receptor subtype has allowed effective treatment of prostate tumors in mice using the new MGF-198AuNPs—thus demonstrating that small sized phytochemicals will play important roles in achieving tumor specificity in drug design. The dual beta and the gamma emissions of Au-198 provides unique advantages for tumor therapy, through the beta energy while gamma rays are used for the quantitative estimation of gold within the tumors and various organs through radio scintigraphy. Detailed in vivo therapeutic efficacy studies, through the intratumoral delivery of MGF-198AuNPs, revealed that over 80% of the injected dose (ID) of MGF-198AuNPs was retained in prostate tumors up to 24 h. There was minimal/no leakage of MGF-198AuNPs to non-target organs including liver, blood and stomach. This unprecedented retention of MGF-198AuNPs within prostate tumors translated into excellent ability of this nanoceutical to reduce tumor volumes in comparison to saline control groups. By three weeks post treatment, tumor volume of control group (saline) was significantly lower than the tumor volume of the two different groups of prostate tumor bearing mice injected with radioactive nanoparticles (1.31±0.00cm3 for control versus 0.18± 0.17cm3 for MGF-198AuNPs for group 1, and 0.22±0.02 cm3 for MGF-198AuNPs for group 2). Observation of normal blood parameters, body weights and the overall systemic tolerance of MGF-198AuNPs, in both the experimental and control groups, suggested new opportunities in oncology for the application of this agent for the treatment prostate and various other tumors.
        Speaker: Mr Kattesh V. Katti (Department of Radiology, University of Missouri, United States of America)
      • 301
        State of the Art and Current Advances on Protein Crosslinking by Irradiation - Protein Based Nanocarriers and Bioactive Nanoparticles
        The highlighted role of protein and peptide based delivery systems relies upon the possibility to develop biocompatible drug carriers featuring site specific delivery, biological affinity among unique advantages. Recently, a technique for protein nanostructuring by the use of radiation has been recently reported by our group. Advantages of the use of radiation over conventional methods are related to the possibility to achieve protein crosslinking and sterilization in a single step, as well as the capacity to allow the design of nanocarriers without the need of monomers or toxic crosslinkers. This work reports the use of high energy irradiation towards the design of size-controlled protein-based nanocarriers and bioactive nanoparticles, using bovine serum albumin (BSA) and papain as model protein and protease, respectively, including the state of the art and current advances of the technology. The technique implies on protein desolvation/solvation techniques followed by crosslinking by e-beam radiation or gamma irradiation alone, although nanoparticles were also achieved in absence of the cosolvents. Size-controlled BSA nanocarriers were manufactured up to 80 nm and papain bioactive nanoparticles up to 12 nm, as determined by dynamic light scattering. Nanocarrier morphology was evaluated by and negative staining transmission electron microscopy. Protein crosslinking and changes in aromatic the amino acids were evaluated by fluorescence measurements. Biocompatibility experiments were also performed by means of cytotoxicity and cytokines production. The potential of the systems for the delivery of radiopharmaceuticals or chemotherapeutic agents were also assayed, using Technetium or Paclitaxel respectively. In conclusion, the technique allowed the production of biocompatible and bioactive protein nanoparticles suitable for the administration of radiopharmaceuticals and chemotherapeutic agents.
        Speaker: Mr Gustavo Henrique Costa Varca (Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP, Brazil)
      • 302
        Radiation-Chemical Synthesis of Nanocomposite Adsorbents Based on Polypropylene Fibers for Selective Removal of Heavy Metals and Radionuclides
        Polypropylene (PP) fibers are widely used in sorption processes. The range of their possible applications can be extended by modification with the use of radiation-induced graft polymerization method. This method allows grafting of nano- microchains of a vinyl monomer with a desired functional group onto the inert surface of PP base, ensuring control over the length and density of the grafted chains. The resulted material consists of two parts: the polymeric base and the chemically bound chains with functional groups (ion-exchange or chelating), and so it can be used as polymer adsorbent. In the past decades, fibrous polymer adsorbents have been considered as potential alternative to granular ion exchange resins because of their high adsorption parameters. Numerous adsorbents on the base of PP fibers have been synthesized, but only a few of them could be adjusted for selective removal of pollutants from water effluents because of limited variety of available functional groups. In recent years, hybrid adsorbents (polymer/inorganic nanoparticles) have been developed as a new class of adsorption materials. They were fabricated mostly by the in-situ formation of inorganic nanoparticles or by incorporation of preliminary formed inorganic nanoparticles into voids of macroporous ion exchange resins. Although polymer fibers are very attractive support in preparing hybrid adsorbents, there are only a few publications on this theme. The considered research was focused on the fabrication of novel hybrid adsorbents based on the polypropylene fibers coated with inorganic nanoparticles for selective removal of heavy metals and radionuclides. The hybrid adsorbents were synthesized through a two-stage experiment: radiation-induced graft polymerization of a vinyl monomer with functional group (ion-exchange or chelating) onto the PP fibers' surface, followed by the in situ formation of inorganic nanoparticels within the grafted chains. For selective removal of radionuclides from contaminated waters (natural or industrial origin) 4 types of hybrid adsorbents based on grafted polypropylene fibers have been synthesized: PP fibers coated with ferrihydrite (iron hydroxide) nanoparticles; PP fibers coated with manganese hydroxide; PP fibers coated with K-Ni and K-Cu hexacyanoferrate; PP fibers coated with hydroxyapatite nanoparticles. FT-IR-ATR, and X-ray diffraction techniques confirmed the formation of inorganic nanoparticles on the PP fibers surface. SEM study revealed that nanoparticles form a homogeneous layer of nanosized aggregates which are rather regular in shape and closely fit one to another forming a compact texture the fibers' surface. The synthesized composite fibers were found to be stable in aggressive solutions for long time. The targeted radionuclide’ adsorption on the composite fibers was studied as a function of contact time, pH, initial ion concentration and the presence of competitive ions. The synthesized adsorbents demonstrated fast adsorption kinetics, high adsorption capacity and rather high selectivity. The proposed strategy of the nanocomposite fibers synthesis opens ample opportunities for the fabrication of adsorbents, catalysts, biochemical and chemical sensors on the base of commercially available polymer fibers, fabrics, resins and membranes.
        Speaker: Ms Yuliia Bondar (Institute of Environmental Geochemistry, Kiev-142, 03680, Ukraine)
      • 303
        Preparation of Polyurethane Acrylate/ Organically Modified Montmorillonite Nanocomposites by Electron Beam Radiation Curing
        The electron beam radiation curing of Polyurethane acrylate (PUA)/Montmorillonite (MMT) modified by octadecylamine (ODA-MMT) nanocomposites was investigated in this article. The nanocomposites were obtained and characterized by different techniques. The produced nanocomposites, showed remarkable improvement in their mechanical and morphological properties, compared to the pristine PUA. The XRD results revealed that the ODA-MMT silicate interlayer spacing increased up to 39 Å, indicating the intercalation structure. Whereas, the pristine MMT microcomposite showed agglomeration. The FTIR results confirmed the intercalation of the PUA chains in the silicate layers, nevertheless, the chemical structure of the PUA was not influenced by the presence of the silicate layers in the matrix. The mechanical properties of the nanocomposites showed incredible increasing in the modulus value, from 8.53±0.40 to 132.43±6.60 MPa by the dispersion of 5 wt% ODA-MMT in the PUA matrix, as well as the tensile and the dynamic mechanical properties were also improved. The radiation dose and the amount of the tri-functional monomer (TMPTA) in the formula were affected significantly the cross-linking affect the cross-linking density of the cured PUA nanocomposites.
        Speaker: Mr Ashraf Salih (Department of Radiation Processing, Sudan Atomic Energy Commission, Khartoum 1111, Sudan)
    • B14: Radiation for Cultural Heritage Characterization Conference Room M2

      Conference Room M2

      Radiation for Cultural Heritage Characterization

      Conveners: Mr Jean Louis Boutaine (consultant), TSec Patrick Brisset
      • 304
        A Survey of the Possibilities of Various Radiographic Techniques for the Non Destructive Examination of Cultural Heritage Artefacts
        How, where and when artefacts were manufactured, how they were exchanged between folks, when, where and how techniques appeared, prospered or disappeared, what has been their evolution and/or degradation during time… are topics of increasing interest. How can we better understand art objects and cultural heritage artefacts and keep them available, in condition as satisfactory as possible, for future generations is a very significant challenge. Due to the broad diversity of materials, and as the artefacts have various, often complex and undetermined compositions, as their elaboration processes are often unknown or at least uncertain, it is generally useful or necessary to combine various examination, characterisation and analysis methods, in order to get pertinent information and thus to give a rational basis for their restoration and conservation. Furthermore, because of the unique or rare nature of cultural heritage artefacts, as a general rule, the techniques which can be used must be either well tested and proven non destructive and non contact methods without any sampling, or tests with strictly authorised small size sampling Radiography has long been applied to the medical diagnosis & to the non-destructive examination of industrial objects. In the area of cultural heritage, it has proven to be invaluable for the examination and the study of works of art. In a first part, a brief survey will be given of the basic physics principles of the different possible variants of the radiographic techniques. They include: conventional X-ray radiography, gamma radiography, radiography using accelerator, radioscopy, beta radiography or secondary electron radiography, electron emission radiography, neutron radiography, autoradiography & computer assisted tomography. Many major types of artefact collections are concerned by radiographic examination: easel paintings (X-ray, electron emission, autoradiography), ceramics (X-ray), stone, metal & wooden statues (X-ray &  ray, tomography), paper & drawings ( particles & secondary electrons), archaeological objects (various techniques), musical instruments (X-ray & tomography). The second part will provide examples of applications of these different techniques on various types of artefacts, focusing on issues related to the study of historical fabrication techniques, the diagnosis of eventual previous restoration & of the object’s condition. If this palette of techniques, eventually associated with complementary NDT techniques, is used by a competent & skilled technician, & if there is a real dialogue between himself & the curator, or the conservator-restorer, or the art historian, or the historian of techniques, or the archaeologist…, it can provide many pertinent elements, contributing to a deeper knowledge of the artefact & insure a conservation process as pertinent as possible.
        Speaker: Mr Jean Louis BOUTAINE (Restauration des Musées de France, France)
      • 305
        Application of Ionising radiation in Studying Akaba and Masai Art Objects Made from Glass
        Glass is known to deteriorate under environmental conditions and therefore it is of major concern to conservationist, cultural heritage funs and Museum Institutions. However, glass art products are common wares, which are made and sold by artists in the low-income groups of different Kenyan communities. They are therefore an economic asset and bread provider for many poor households. For the authorities to make a decision on how to help the involved artists and resellers, to add value to their products and capture a winder market, especially within the tourist and business visitors, better understanding of their structure, morphology and elemental content was seen to be necessary. Ionizing radiation instrumentation are good tools for this kind of study and therefore XRF and radiography facilities at Institute of Nuclear Science and Technology were used to analyze randomly purchased objects from street hawkers and market resellers. The spectra and radiographs will be analyzed and the resultant data used to assess the source of deterioration and give informed recommendations to policy makers and stakeholders in the business.
        Speaker: Mr Michael J. G. Gichuru (Institute of Nuclear Science & Technology, College of Architecture and Engineering, University of Nairobi, Kenya)
      • 306
        Radiographic Investigation of Archeological Objects
        RADIOGRAPHIC INVESTIGATIONS OF ARCHEOLOGICAL OBJECTS Şinasi EKİNCİ Turkish Atomic Energy Authority Çekmece Nuclear Research and Training Centre, Department of Nuclear Techniques Istanbul, TURKEY sinasi.ekinci@taek.gov.tr ABSTRACT Radiography is a versatile technique with many applications to archaeological and art historical artefacts. It can be used to assess the condition of objects before conservation or restoration treatment, to gain information of materials used and methods of construction, and to reveal the secrets of the embalmer’s art, hidden within mummified remains. The techniques can be applied to materials as diverse as papers, fabric, wood, ceramic and metal, as well as to human and other animal remains. Radiographic examination basing on film imaging or digital imaging techniques may provide images of objects concealed within a mass of corrosion and may even reveal a previously unknown painting, hidden beneath a later work. All of this can be carried out non-destructively, making radiography an invaluable tool for the study of cultural materials. Radiographic investigations of the archaeological objects at Çekmece Nuclear Research and Training Centre were carried out since 2004 in collaboration with Archaeology Museum of Istanbul and Directorate of Istanbul Central Laboratory for Restoration and Conservation. This work describes radiographic investigations of the archaeological objects in order to support museums, laboratories and archaeology specialists for the restoration, conservation and replica processes, as well as inventory purposes. Film based, flat panel and imaging plate radiographic techniques were used in the examinations. Some of the investigated objects in this study are anchors of 13th Century of Byzantine Empire taken out from a wracked excavation, chains used in the Golden Horn during the period of Byzantine Empire, head of the Snaky Statue from Roman Period being situated in Sultan Ahmed Square in Istanbul, metal objects from Bathonea excavation in Istanbul, etc. Findings obtained from the examined objects were assessed together with archaeology specialists in order to make comment about their history and production methods and to decide for the restoration and conservation processes. The use of radiographic examination for the preservation of cultural heritage became a very important tool that allows scientists and archaeologists to accurately identify and conserve items that would have been lost or damaged in the past. The results obtained from this study were very beneficial for the Istanbul Archaeology Museum and Conservation and restoration Laboratory for determining the internal structure and surface condition of the objects before treatment for restoration, conservation, replica works and a lot of other processes.
        Speaker: Mr Sinasi ekinci (Turkish Atomic Energy Authority, Çekmece Nuclear Research Center, Turkey)
      • 307
        Using X-rays to Detect Hidden Images (Old Masters) on Priming Canvases
        Improving the technology of radiation: enhancing the stability of the sources, the possibility of fine adjustment of the anode voltage, emission control range and high sensitivity and stability of detectors allow the use of this equipment for the detection of latent images on the canvases (paintings). Experience in the use and methods of application of this equipment to solve the problem of detection of illegal movement of works of art. Emerging issues and their solutions.
        Speaker: Mr Boris Artemiev (ZAO RII MSIA SPECTRUM, Russian Federation)
      • 308
        Some Applications of the X-Ray in the Service of the Archeological Site of Volubilis
        The studies done during this work are part of the collaboration agreement between the Ministry of Culture and CNESTEN. Investigative studies, diagnosis and characterization of a cultural archaeological heritage, carried out before any repairs or restoration and conservation. The studies are to implement two approaches combined namely industrial radiography X and PMI (Positive Material Identification) for quantitative and qualitative evaluation of a variety of archaeological items on the site of Volubilis. These two complementary methods allowed us firstly to evaluate the condition of structures for possible restorations, mobilizations and characterize in situ controlled materials without sampling.
        Speaker: Mr Rachad alami (National Center of Energy Science and Nuclear Techniques, Morocco)
      • 309
        Secrets and Mysteries of our Past Revealed by Neutron and X-Ray Radiography/Tomography
        Heritage is our legacy from the past, what we live with today and what we pass on to future generations. Our cultural and natural heritages are both irreplaceable sources of life and inspiration. Places as unique and diverse as also the wilds of East Africa’s Serengeti, Cradle of Humankind in South Africa, the Pyramids of Egypt, the Great Barrier Reef in Australia and the Baroque cathedrals of Latin America make up our world’s heritage. What makes the concept of World Heritage exceptional is its universal application. World Heritage sites belong to all the peoples of the world, irrespective of the territory on which they are located. It is a universal need to reveal those important and in most cases hidden features of findings such as artefacts or fossils in a non-invasive manner in order to preserve, sometimes only artefact ever found, in the most a responsible manner for future generations to also study with possible new developed analytic techniques. Currently, neutron and based analytical techniques play an important role in both applied research and practical applications. Today, various experimental setups of neutron techniques can be used effectively for imaging purposes. Moreover, recent developments of methods, which are used primarily for medical applications, like diagnostics or treatment (e.g., based computer tomography, tomotherapy, image guided radiotherapy, etc.), use advanced imaging principles. However, both neutron and imaging techniques do not offer directly analysis of elemental composition of studied entities. One important application of neutron and radiation based imaging techniques is the non-invasive study on objects from cultural heritage importance, where these probes reveal valuable hidden information in a non-destructive and non-invasive manner. The aim of this presentation is to highlight the non-destructive analysis of cultural artefacts using the capabilities of neutrons and ’s as penetrating probes. Several case studies will be discussed about neutron and radiography and tomography investigations of cultural artefacts being practiced at various research institutions worldwide.
        Speaker: Mr Frikkie De Beer (South African Nuclear Energy Corporation (Necsa), South Africa)
      • 310
        The Radiography in the Service of the Preservation of the Moroccan Historical Heritage
        Abdeslam BENSITEL1, Rachad ALAMI1 , Khadija BOURCHOUK2 1Division of Instrumentation & Industrial Applications, CNESTEN (Centre National de l’Energie, des Sciences & des Techniques Nucléaires), Rabat, Morocco Ab.bensitel@gmail.com 2Musée Archéologique de Rabat, Division des Musées, Direction du Patrimoine Culturel Marocain, Ministère de la Culture, Rabat, Morocco. Abstract The Moroccan historical heritage is extremely rich and varied. The history more than millennium of Morocco bequeathed us objects of the heritage going of the prehistoric and antique Art to the Amazighe and Arab-Islamic art by way of Greco-Roman period. Numerous objects of the Moroccan heritage suffer from a doubtful state of preservation even critic in certain cases. It is consequently indispensable to develop and to apply techniques of examination, characterization and analysis of the oeuvres of art or the Moroccan cultural heritage, constituent materials of these works, to know the mechanisms of their elaboration, their evolution and\or degradation and establish recommendations with the aim of their restoration and of their preservation. For that purpose, we privilege the non-destructive methods, without contact (when possible), without sampling. Among these methods, some make use of the X-rays and the gamma. These methods, the only ones or associated with other techniques are applied to very diverse works and materials of all kinds, any origin and any age. The application of the X radiography in numerous pieces of the Archaeological Museum of Rabat, in particular the statue of Ptolémée (marble), a Roman ceremonial helmet (bronze), a pyxidium with relief (bone) so allowed: - To estimate the area and the extent of the damages undergone by these objects; - To contribute to a better knowledge of the techniques of manufacturing by the artists having realized these works as well as the previous restorations made on the studied pieces; - The assistance-advice for the benefit of the curators and the restorers for the establishment of specific methodologies of restoration to every type of object. The radiography also allows the contribution to the establishment of detailed identification sheets of valuable museum pieces, particularly those being often the object of loans between museums. Keywords: Radiography, archeology, marble, bronze, bone
        Speaker: Mr Rachad ALAMI (National Center of Energy Sciences and Nuclear Techniques (CNESTEN), Morocco)
      • 18:15
        Discussion
    • A14: Technical Cooperation Success Stories IAEA Board Room B/M1

      IAEA Board Room B/M1

      Technical Cooperation Success Stories

      Conveners: Mr Luis Carlos Longoria Gandara (IAEA), TSec Sunil Sabharwal
      • 311
        Recent Radiation Research and Technology Development in Croatia
        The Ruđer Bošković Institute is Croatia’s leading scientific institute. The Radiation Chemistry and Dosimetry Laboratory (RCDL) has remained until the present day the only unit in the country pursuing both basic and applied scientific research in the fields of radiation chemistry, dosimetry and radiation processing. Physico-chemical effects of irradiation, being function of absorbed dose, are used for the quantitation of absorbed energy, i.e., dosimetry. Two families of liquid chemical dosimetry systems have been developed by the RCDL. The low-dose system is nowadays one of the best characterized chemical dosimetry systems in the range of therapy and accident doses. The high-dose system, based on the ethanol-chlorobenzene (ECB), has been accepted as a joint ISO/ASTM 51538 standard. Research in applied radiation chemistry and radiation microbiology, analyses of epidemiologic and economic data, our presence on national and international bodies generating and maintaining corresponding regulations, permanent improvements of our irradiation facilities and other activities all have helped introduce into Croatia the necessary scientific, technical, legal, economic and other prerequisites for technology transfer in the yield of radiation processing. At present, RCDL has the only facility of its kind in Croatia and the region. The main equipment is a batch type panoramic $\gamma$-irradiator ($95$ kCi ${}^{60}$Co) which has been designed by the RCDL staff, and its periodical upgrading has been regularly assisted by the IAEA. Although only an experimental facility at the beginning, it was designed with the future role of a multipurpose pilot scale irradiation facility in mind, capable to contain more than $100$ kCi of ${}^{60}$Co. The irradiator is suitable for a variety of applications, from medium dose range used in radiobiology to high doses used in radiation processing and radiation chemistry. The capacity of the irradiator chamber is $4$–$6$ m$^3$ of material per batch. There is no conveyor to transport goods into and out of irradiation chamber giving maximum flexibility with respect to the dimensions and weight of the objects. Performing commercial scale irradiation for sterilization, pasteurization, decontamination and disinfestation of various materials such as medical supplies, pharmaceuticals, foods, cosmetics and toiletries, packaging, etc., provided the necessary understanding of practical aspects of irradiation processes and dosimetric control methods. In recent years the interest for irradiation protection and conservation treatment of cultural artefacts has been strongly increased and successfully carried out in Croatia and region. In this lecture a review of scientific research and development of the RCDL over the past five years will be presented, with special attention given to the recent upgrading of the facility. This upgrading has enabled the RCDL to offer the exchange of knowledge and experience in many areas of scientific research as well as to offer more extensive and diverse applications of radiation technology. The support of the IAEA in ensuring timely supplies ${}^{60}$Co over the years, especially through the recent Technical Co-operation Project CRO/1/006 (2014-2015) is gratefully acknowledged.
        Speaker: Ms Branka Mihaljević (Ruder Boskovic Institute, Croatia)
      • 312
        Multipurpose Gamma Irradiator and Mobile Unit with an Electron Beam Accelerator Developed in Brazil
        The radiation processing technology for industrial and environmental applications has been developed and used worldwide in the fields of water treatment, advanced materials, nanotechnology, medicine, tissue engineering, disinfestations and disinfection of books and documents, processes and industrial production and natural resources, among others. The Radiation Technology Centre in Nuclear Energy Research Institute (IPEN), of the National Nuclear Energy Commission (CNEN) developed a small size continuous run and multipurpose industrial gamma irradiator with a revolutionary design and national technology to be used as a demonstration facility for manufacturers and contract service companies that need economical and logistical in-house irradiation system alternatives. In addition, it will be useful for supporting the local scientific community on development of products and processes using gamma radiation, assisting the traditional and potential users on process validation, and for training and qualification of operators and radioprotection officers. The developed technology for this facility consists of continuous tote box transport system comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a revolving door integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m2 of floor area, the irradiator design is product overlap sources and the maximum capacity of cobalt-60 wet sources is 37 PBq, tote boxes, Category IV, wet storage. The performed qualification program of this multipurpose irradiator was based on AAMI/ISO 11137 standard, which recommends the inclusion of the following elements: installation and process qualification. Nowadays, installed activity in the multipurpose irradiator is 7.4 PBq (200 kCi) with cobalt-60 sources. For irradiator dose optimization, the source distribution was done using the software Cadgamma developed. The poly-methylmetacrylate (PMMA) dosimeters system was used for irradiator dose mapping. The economic analysis and performance, concerning to the dose uniformity and cobalt-60 utilization efficiency were calculated and compared with other commercial gamma irradiators available in the market. Nowadays, the Radiation Technology Centre is involved in the establishing of a mobile unit with an electron beam accelerator to treat industrial effluents for reuse purposes. The mobile unit will be equipped with an electron beam accelerator (0.7MeV and 20kW) with safety requirements (BSS, IAEA and CNEN Safety Standards), and can be used for treatment of effluent from petroleum production, for petroleum desulfurization, and, in addition, for degradation of toxic organic compounds in wastewater for reuse. This project is supported by the IAEA (TC Project BRA1035 - 2016-2018) and by the Brazilian Financial of Studies and Project (FINEP). To enlarge the national capacity to treat industrial effluents using electron beam accelerators, the mobile unit treating effluents on site from 1m3/h up to 1,000m3/day, will provide an effective facility between a laboratory-scale plant to a large-scale plant, with the objective to demonstrate the efficacy and to transfer the technology. Studies have taken place in various productive sectors in the country and in other foreign laboratories to prove that the radiation treatment offers technological and economic benefits over the conventional techniques for treating recalcitrant pollutants.
        Speaker: Mr Wilson Aparecido Parejo Calvo (IPEN-CNEN/SP)
      • 313
        Radiation Processing in the Philippines: Developments and Prospects
        Radiation processing is the treatment by radiation to get the desired effects in the products. It offers various advantages in the field of sterilization of medical products, food irradiation and a treatment of a variety of products, which have direct relevance to industrial productivity and healthcare. Various R&D activities in the Philippines have been undertaken since 1965 by the Philippine Atomic Energy Commission/Philippine Nuclear Research Institute (PAEC/PNRI), the academe and other government research institutions utilizing the gamma irradiation facility of PNRI and the recently established electron beam (EB) irradiation facility. These are demonstration facilities to assess the techno-commercial viability of the processes such as decontamination of spices, herbal products and cosmetic raw materials, food irradiation and radiation sterilization of medical devices. The new areas being explored include the use of EB-grafted non-woven fabrics as metal adsorbents and the use of modified carrageenan as plant growth promoter. These studies strongly indicate that radiation processing has a strong potential for technology transfer to Philippine industries. This paper presents an overview of current developments in research activities and commercial applications of radiation processing in the Philippines, the different radiation processing facilities, the ongoing upgrading of the gamma irradiation facility to meet the demands of the industry and the technology transfer activities currently being undertaken.
        Speaker: Ms Luvimina Lanuza (Philippine Nuclear Research Institute, Philippines)
      • 314
        Radiation Processing in Ghana: Achievements, Prospects and Challenges.
        Ghana Atomic Energy Commission (GAEC) commenced research and development activities in the area of radiation processing in 1970 with a laboratory scale irradiator through the assistance of the International Atomic Energy Agency (IAEA). The programme was facilitated by training of the relevant scientific and technical expertise at the national level . In 1994, a semi-commercial irradiator (Gamma Irradiation Facility, GIF) was installed by the Government of Ghana with the assistance of the IAEA. The GIF was further upgraded in 2010 with funds from the Export Development and Agricultural Investment Fund (EDAIF) to enable full-scale commercial operation. The Ghana Standards Authority has developed two standards to regulate radiation processing in the country. Currently the GIF provides irradiation services to the agricultural, medical and export sectors of the economy notwithstanding further emerging prospects in the agro-processing sector. The School of Nuclear and Allied Sciences has developed a postgraduate programme in radiation processing to ensure a sustainable requisite human resource base. Realistic mechanisms for public-private partnerships need to be identified and implemented to assist with transfer of the technology of radiation processing in the country. Continued support of the government, regional collaboration, and strategic cooperation with the IAEA will be vital in the successful commercialization of radiation processing technology.
        Speaker: Mr Abraham Adu-Gyamfi (Ghana Atomic Energy commission, Ghana)
      • 315
        The Radiation Processing in Cuba. Past, Present and Perspective.
        ABSTRACT In the present paper is shown the evolution of the radiation processing in Cuba and the development reached until today and the perspectives, as well as, the technical characteristics of our radiation facilities, the results obtained with the application of this technology in several branches of the science, like the medicine, the biology and the agriculture, so much at research scale as pilot, it point out the most significant aspects related with the sterilization of medical-pharmaceutical material, the food irradiation, of biological products, modification of materials, detection of irradiated foods, quality control management, dosimetric systems employed in the process control and the regulatory aspects of the radiation processing in our country.
        Speaker: Mr Enrique Francisco Prieto Miranda (Centro de Aplicaciones Tecnológicas y Desarrollo Nuclear, CEADEN, Cuba)
      • 316
        Drafting and Preparation of Proposals of Irradiation Plants: Mexico Experience
        The drafting, integration and evaluation of infrastructure projects face huge challenges. Each Project has a relevance and a unique nature, although, they are developed in conditions and environments more or less similar. This paper describes different progress that were accomplished in drafting, integrating and evaluating various projects focused to specify, design, build and commissioning industrial irradiation plants based on electron beam in mexican territory. Having as a background the experience that ININ has gained since 1980, when its Gamma Industrial Irradiation plant was commissioned and 1983, when its commercial operation started, the key elements required to take into account related with the installation of new irradiation plants based on electron beam are: 1)The market demand that justifies the need to have the facility. 2)Other additional key drivers that strength the arguments to install a new facility. 3)The different kinds of regulations, the legal framework, types of technologies and the particular requirements of industries wherein the supply of irradiation services will be focused like medical disposables and food products. 4) The technical details to fulfill the specification of irradiation service that the facility will offer to the customers: desired effects on materials, uniformity and range of doses, guarantee, quality control and complementariy services like microbiological analysis or dose mapping, risk management among users and services by the supplier. As a result of the main considerations just mentioned, it may be possible to have a solid basement to draft, integrate and evaluate a new project. The next step should be the cost-benefit analysis taking into account aspects related with market study, the legal framework and a sensitivity analysis. Costs of the project should be treated with the sufficient detail according with the level of development of the Project. From what was mentioned above, any organization has the possibility to define the technical characteristics of the main equipment, basically, the e-beam accelerator required: energy, e-beam or e-beam and X rays, power, type of technology (Linac, RF), among others. The experience shows that if at the very beginning exists uncertainty about the financial resources for the project, it is very convenient to have alternatives available since the very early stages to face changes on the scope and on the specific requirements of diverse budget sources, these issues could assure the sucess of the project.
        Speaker: Mr J. Walter Rangel Urrea (National Institute of Nuclear Research (ININ), Mexico)
    • 11:00
      Coffee break
    • A15: Emerging Radiation Technologies IAEA Board Room B/M1

      IAEA Board Room B/M1

      Emerging Radiation Technologies

      Conveners: Ms Monique Lacroix (INRS-Institut Armand-Frappier), TSec Bum Soo Han
      • 323
        Economics of Radiation Processing Technology: Posers and Prospects
        Radiation processing of materials for a variety of applications has been well-established, and is also continuing to evolve further. The cost of radiation treatment, that is, say, dollar per kGy per kg, is dependent on several factors of the radiation facility and operations, and almost always irrespective of the nature of material being treated. Consequently, materials of higher value like medical disposables, most spices, etc. have been more favourable for radiation treatment from the point of view of economics. Furthermore, certain minimum overhead cost is invariably present in all cases, and thus low-dose requirement for certain commodity may not necessarily mean lower cost for radiation treatment. The absorbed radiation dose required is known to vary (Gy to kGy) over a few orders of magnitude, and a single radiation facility to cater to the entire range is a known challenge. There are technology options but they come with added complexities. The scope for year-round availability of the same material, or a group of materials, requiring radiation processing is another key issue to be addressed. Yet another dimension of technology has been the availability of a choice between gamma radiation plant and electron accelerator (EB machine) facility, each with its own strengths and issues. The ease and ruggedness of operation of Cobalt-60 based plants and their modest infrastructural needs are appreciable and proven records are available. However, the availability and transportation of sources for replenishment, and mostly fixed-dose delivery feature of gamma facility pose certain limitations. EB systems, especially of variable energy and power, would prove advantageous, while the ease and ruggedness of their routine functioning over sustained, long-periods has very limited record, leave alone the need for assured availability of high-quality power supply (issue in many countries). Mostly two major areas of use are contemplated by the stakeholders, namely, sterilisation or hygienisation of products on one hand, and tackling and treating pollutants, on the other hand. Safe and often prolonged preservation is the need in the former case and for cost consideration. The risk and cost to society and environment by not-treating the harmful pollutants in managing them are the drivers in the latter case. Placing a simple dollar figure here may not be necessarily feasible or easy. Naturally, for policy makers and end-user stakeholders, the above scenario presents an equivocal picture, of an attractive technology available for value-addition, but with techno-economic challenges. The author has had experience in dealing with stakeholder experts from IAEA Member States, and earlier in India with different industries seeking to use radiation processing. Invariably, objective, frank analysis of every specific case has been necessary and useful to better understand and/or explain the various aspects and factors to be addressed. It is imperative for technology experts to speak in single unequivocal language to the national policy makers and end-user stakeholders, so that the considerable merits of radiation processing are well harnessed to meet every specific national need and priority.
        Speaker: Mr Natesan Ramamoorthy (Retiree from IAEA, Vienna and BARC, DAE, Mumbai, India)
      • 324
        Radiation Modification of Carboxymethylated Chitosan – from Basics to Applications
        The mainstream of radiation modifications of polysaccharides was limited to reduction of molecular weight due to main-chain degradation in order to facilitate further processing or induce specific biological activities. On the other hand, graft polymerization of functional monomers initiated through radicals crated by ionizing radiation on polysaccharide chains, or as effect of glycosidic bonds cleavage, was also extensively explored. Besides, possibility of crosslinking of polysaccharides by radiation initiation was demonstrated, firstly for water-soluble cellulose derivatives – high degree of substitution (DS) of cellulose with side chains and high concentration in aqueous solution were found to be advantageous to obtain significant yield of gel fraction. In the present investigations behavior of carboxymethylchitosan under ionizing radiation was explored and exemplary application proposed. Carboxymethylchitosan (CMCS) of the deacetylation degree (DDA) 93.8%, DS 96% was obtained from Kraeber & Co. GmbH (Germany). Medical grade chitosan (CS) obtained from Heppe Medical Chitosan GmbH (Germany), with DS 90% was also used. Solutions of CMCS and CS were irradiated by electron beam (EB) with and without a crosslinking agent of poly(ethylene glycol) diacrylate (PEGDA, Sigma-Aldrich). Obtained gels were evaluated by standard sol-gel analysis. Results of this study indicated that ionizing radiation is a convenient tool to synthetize hydrogels based on CMCS either with or without PEGDA when irradiated in highly concentrated solutions, whereas CS, its parent polysaccharide, as expected, is prone to form gels only in the presence of the crosslinking agent. The method engaging PEGDA allows formation of macroscopic gels even from a CMCS and CS solutions of low concentration resulting in gels of gel fraction as high as 80%, which is distinct from the known technique of polysaccharide crosslinking in the paste-like state – irradiation of CMCS 20% concentration results in gel fraction less than 50%. The CMCS gels were found no to cause cytotoxicity (as tested by LDH assay) and demonstrated antimicrobial activity, especially towards gram negative bacteria. If the dose applied for gel formation is of 25 kGy or more, it may be sterilized simultaneously during its synthesis. This was explored (CMCS aqueous solution) in manufacturing of internal hydrogel scaffold for nerve regeneration guides. Regular nerve guidance tubes of polylactide & polycarbonate, elaborated in our laboratory, were filled with CMCS mixture with water – paste like-state or physical gel, based on conditions determined in this study – and irradiated with EB. After in situ synthesis of the gel inside the tube, the product is ready for immediate use, because applied technology combines gel formation and sterilization into a single process.
        Speaker: Mr Radoslaw Wach (Institute of Applied Radiation Chemistry, Lodz University of Technology, Poland)
      • 325
        Remediation of Petroleum Impacted Soils with Electron Beam Irradiation
        Pollution of soil by heavy hydrocarbons (HH, C12-C40) is a major global environmental issue. Heavy hydrocarbons pose a significant remediation challenge because they are recalcitrant and relatively immobile in soils, and hence will persist in the environment for a long time. Electron beam has the potential to both crack and polymerize hydrocarbons at lower temperatures than similar energetic methods for HH remediation such as thermal desorption and pyrolysis. Electron beam remediation must be proven fast, efficient, and economical at large scales. To this end, the present research has several objectives: show reduction in mass of heavy hydrocarbons in soil for proof of concept; assess impact of testing parameters (such as radiation dose); and design an experimental setup to evaluate soil treatment, both in a batch configuration and in a continuous configuration. Samples with initial HH contamination ranging from 2% to 10% (w/w) were irradiated with an 18kW, 10 MeV RF LINAC in various configurations. Configurations including stationary and moving soil containers were developed to irradiate samples ranging in size from 100 g to 3 kg. Various doses were tested from 50 kGy to 2000 kGy to assess the energy cost and effectiveness of various levels of remediation. Beam penetration profiles and HH reduction profiles in the soils were measured. Similar soil samples were also thermally desorbed and pyrolyzed to compare energy input to irradiation at similar maximum temperature (~420ºC) and to characterize chemical reduction mechanisms during irradiation. Treated and untreated samples were characterized using colorimetry and gas chromatography (GC-FID) performed with hydrocarbon solutions in dichloromethane. Tests showed effective HH mass reduction, which resulted in TPH reduction (below 0.1%, satisfying environmental regulations) in both batch and continuous treatments. Temperature Programmed Desorption and Oxidation (TPD/TPO) showed evidence of both volatilization and char formation as the means of heavy hydrocarbon mass reduction.
        Speaker: Mr David Staack (Texas A&amp;M University, United States of America)
      • 326
        Electron Beam Pretreatment of Lignocellulosic Biomass
        Background: Cellulose is the major structural component of wood and plant fibers and is the most abundant polymer synthesized by nature. Despite this great abundance, cellulosic biomass has seen limited application outside of the paper industry. Its use as a feedstock for fuels and chemicals has been limited because of its highly crystalline structure, inaccessible morphology and limited solubility. Any economic use of lignocellulosic resources for the production of fuels will require a ‘‘pretreatment’’ technology to enhance the accessibility of the biomass to enzymes and/or chemical reagents. Most pretreatment techniques either are energy intensive or require the use of toxic chemicals. In this study electron beam irradiation was used as a pretreatment technique. Methodology: Samples were irradiated at IBA Industrial, Edgewood, New York USA, using a 90 kW, 3 MeV Dynamitron. Most samples were less than 0.5 cm thick with a bulk density of <0.6 g/cc, thus giving equal in equal out dose. Thick (2.5 cm) wood boards were irradiated from both sides giving a uniform dose profile. The dose was determined with cellulose triacetate films. Molecular weight was determined using a Waters Breeze size exclusion chromatography system fitted with a Waters 2414 refractive index detector, and two Polymer Laboratories Polypore columns (330×7.5 mm2). The relative1 crystallinity was determined using a Rigaku DMAX-1000 X-ray diffractometer with Ni-filtered Cu Kα radiation (λ=0.15418 nm). All other tests were conducted in accordance with ASTM or TAPPI standards and gravimetric analysis. Results: As the dose was increased from 0 to 1,000 kGy, the molecular weight decreased from 80,000 to 5,000 Da and the relative crystallinity decreased from 0.87 to 0.45. The wood toughness and energy required for milling was decreased by about an order of magnitude. The solubility of irradiated wood in water, 0.2N NaOH and 2.0N NaOH increased with increasing dose with 95% of the wood soluble in 2.0N NaOH after 1,000 kGy. The hot water extraction of hemi cellulose and lignin increased along with dose. The extracted lignin also showed an increase in solubility in acidic solutions. Most importantly, the rate and total sugar yields from enzymatic hydrolysis increased with increasing dose. There did not appear to be any “poisoning” of fermentation to ethanol due to the presence of furfurals. Sugars extracted from irradiated wood shows an increase in the rate of fermentation. Conclusion: Electron beam irradiation of lignocellulosic biomass appears to be an excellent pretreatment technique to reduce the recalcitrance of the biomass. Electron beam treatment is less energy intensive and does not use or produce toxic chemicals than other pretreatment techniques. Electron beam treatment reduces the crystallinity and molecular weight of cellulose, increases hot water extraction of lignin and hemicellulose, and increases the rate and total sugar produced by enzymatic hydrolysis.
        Speaker: Mr Mark Driscoll (SUNY College of Environmental Science and Forestry, United States of America)
      • 327
        Radiation-Induced Admicellar Polymerization of Methyl Methacrylate on Cassava Starch
        Cassava starch (CS) is a natural polymer that is inexpensive and abundant, especially in Thailand. In addition to being cost-effective, CS is also biodegradable, compostable, non-toxic and most importantly renewable. Consequently, blending CS with other biodegradable synthetic polyester such as poly(lactic acid) (PLA) is economically interesting, due to a high potential of cost reduction as well as biodegradability of their blends. Nevertheless, it is very difficult to blend starch with other synthetic polymers, due to their incompatibility. Several research groups reported their attempt to improve the compatibility between synthetic polymers and starch using different techniques. Among these available methods, the modification of starch surface by admicellar polymerization is rarely investigated. Admicellar polymerization offers several advantages over traditional techniques. Accomplished in aqueous solution, this environmentally friendly technique can form nanoscale polymeric thin films, with minimum chemical usage and without the use of organic solvents. Additionally, this benign technique is able to maintain basic properties of the original material. Admicellar polymerization is applied to induce surface modification to make two components of their polymeric composites more compatible. Applications of admicellar polymerization are numerous, from reinforcements of composites to value addition of functional textiles. These examples emphasize the advantages of using admicellar polymerization as an effective method to enhance compatibility between a filler and a polymer matrix, which ultimately leads to improved mechanical properties of their composites. Our recent work has proven that admicellar polymerization, induced by thermal process, can be successfully applied to coat the surface of starch with poly(methyl methacrylate) (PMMA) to render it more hydrophobic and more compatible with PLA. The objective of this research is to further expand our previous study by applying gamma radiation to induce admicellar polymerization. The third step of admicellar polymerization is traditionally induced by thermal process, with chemical initiators. However, radiation process requires no catalyst to initiate the reaction, thus resulting in contamination-free products. In this study, methyl methacrylate (MMA) is used as a monomer for the formation of ultra-thin PMMA film on the surface of CS. Surface modified CS is characterized by iodine test, floatation test, film formation analysis, Fourier transform infrared spectroscopy (FTIR) as well as thermal gravimetric analysis (TGA). The comparison is made between cassava starch modified by radiation process (RS) and thermal process (TS). Results from film formation analysis, FTIR and TGA indicate that RS shows higher percentage of PMMA film formation than TS, hence confirming that radiation processing can be applied as an alternative method for surface modification through admicellar polymerization.
        Speaker: Ms Kasinee Hemvichian (Thailand Institute of Nuclear Technology (Public Organization), Thailand)
      • 328
        Preparation and Characteristics of Reduced Graphene Oxide in Ethanol/Water Solution by γ-Ray Irradiation
        Reduction of graphene oxide (GO) in ethanol/water solution in the presence of oxygen by γ–ray irradiation was studied. Suspension of GO was prepared by dispering graphite oxide in the ethanol/water solution at a concentration of about 1 mg/ml under ultrasonic condition, and then irradiated by γ–rays in an absorbed dose range of 0 – 250 kGy. The characteristic properties of GO and reduced GO (RGO) samples were analysed by Ultra-violet visible (UV-Vis) spectroscopy, Fourier–transform infrared spectroscopy (FTIR), X–ray diffraction (XRD), Raman spectroscopy, Transmission electron microscopy (TEM), Contact angle and Electrical conductivity measurements. The conductivity of the RGO was increased from 2.4x10-2 to 2.2 S/cm with increasing the absorbed doses from 25 to 250 kGy. Results of this study were indicated that a promising way could produce a large amount of pure graphene from GO with a simple reducing process using the gamma irradiation method.
        Speaker: Mr Binh Doan (Research and Development Center for Radiation Technology, Research and Development Center for Radiation Technology, Viet Nam)
      • 329
        Radiation Induced Oxidation, Cross-Linking and Grafting of Ultra-High Molecular Weight Polythylene
        Ultra-high molecular weight polyethylene (UHMWPE) has excellent chemical inertness, biocompatibility, mechanical property and wear-resistance, which is widely used in engineering and medical fields. Some drawbacks of UHMWPE need overcome by radiation processing, such as poor compatibility, creep-resistance and yield strength. In this work, radiation oxidation and grafting were adopted to modify the surface property of UHMWPE. Radiation cross-linking and annealing were used to improve the creep-resistance, yield strength and wear resistance of UHMWPE. The results indicated that radiation oxidation and grafting could effectively change chemical groups on the surface of UHMWPE. However, radiation oxidation could not remarkably improve the surface property of UHMWPE, such as hydrophilicity, even at a dose of 300 kGy by gamma irradiation in air [1]. Radiation grafting of acrylic acid could significantly improve the hydrophilicity of the UHMWPE powder. The UHMWPE powder with grafting yield of less than 10% presented a good dispersion in water. Radiation cross-linking and annealing improved creep-resistance and yield strength of the UHMWPE sheets. The cross-linked UHMWPE sheet with a dose of 300 kGy was without obvious deformation under a load of 0.06 MPa at 270 °C in 4 h [2]. In addition, the cross-linked UHMWPE powder as an additive, even at low content, could improve the wear resistance of pristine UHMWPE. In conclusion, the surface and mechanical properties of UHMWPE can be effectively improved by radiation processing.
        Speaker: Mr Guozhong Wu (Shanghai Institute of Applied Physics, China)
      • 12:35
        Discussion
    • B16: Technical Cooperation Success Stories - country reports Conference Room M2

      Conference Room M2

      Technical Cooperation Success Stories

      Conveners: Mr Joon-Ha Jin (GammaTech Inc.), TSec Patrick Brisset
      • 330
        The Participation of the Technological National Centre in the Technical Cooperation Program Activities
        The National Technological Centre (CTN) with headquarter in Luanda, is a public institution tutored by the Ministry of Science and Technology, in charge to realize applied scienti-º3fic research. This paper aims to inform the success of the participation of Technological National Centre in the activities of the cooperation between Angola and the International Atomic Energy Agency through the Technical Cooperation Program. The purpose of the Cooperation is to help the country to build, strengthen and maintain human and institutional capacities for the safe, peaceful and secure use of nuclear technology in support of national development. The participation of Technological National Centre starts from 2006 up to now. To achieve the goals proposed, three main phases have been set up in the projects implementation: outward specialists visits (from other latitudes), human resources empowerment and training (member mobility in the projects) and laboratories equipment acquisition (Creation of laboratory-based infrastructure). With this program, the Technological National Centre was able to set up the laboratories of Non- destructive Testing and radioisotope tracers. Around 20 project members were trained in renowned centres in different regions. Through these laboratories, the Centre has got the capacity of radioisotope tracers application in oil industrial as well as the use of non destructive techniques to improve quality of industrial goods and service. In term of contribution to socio-economic development in the country, in the process of empowerment and training of science, technologies and innovation system’s actors in Angola, the National Technological Centre through this laboratories trained 21 trainees in Nondestructive test , level I, in Penetrant Testing, Magnetic Particle Testing, Ultrasonic Testing and Radiography testing, 09 are working now in local companies, and another group of 5 trainees are training on radiotracer techniques in Technological National Centre. Future prospects are to empower human recourses in various techniques to use the maximum potential of machines existing in the Centre to solve practical problems and address basic human needs. The cooperation concept always ends up in a win-win. From experience, the National Technological Centre thinks that feedback is not significant enough in term of sponsorship assessment but this does mean it will never be noticeable. It cannot appear at this initial time, it will surely
        Speaker: Mr Kabey Mbaz Rodolfo (Centro Tecnologico Nacional, Angola)
      • 331
        Progress, Problems and Prospects of Radioisotope Technology in Nigeria
        Nigeria as a member State of the International Atomic Energy Agency (IAEA) has benefited immensely in the field of radioisotope technology through the agency’s support in manpower development, deployment of relevant equipment and other relevant support towards the Centre’s desire to setup an Industrial Isotope Technology (IIT) laboratory at the Centre for Energy research and training (CERT), Ahmadu Bello University (ABU), Zaria. The Center has organized many trainings in this regard, among these is the National Seminar organized in collaboration with the Kaduna Refinery and Petrochemical Company Limited (KRPC) hosted by CERT and supported by the IAEA. This national conference was held on 12th to 16th August, 2013 which saw a large number of participant mainly from the oil and gas industries in attendance. Nigeria with its position as one of the top nine oil exporters worldwide, with five functional refineries, eleven licenses issued for construction of new refineries, a host of other process related industries and thousands of kilometers of pipelines transporting crude and refined petroleum products that crosscut the country, is believe to be an ideal terrain for radioisotope technology application. This paper highlights the progress, evaluates the problems and prospects of this technology in Nigeria.
        Speaker: Mr Arabi Suleiman ABDULLAHI (Centre for Energy Research and Training, Ahmadu Bello University, Nigeria)
      • 332
        Industrial Application of Radioisotopes in Zimbabwean Industries: a Report on RTD Experiments in Cement Industry, Radon Monitoring in Coal and Fly Ash of a Small Thermal Power Plant and NDT Activities
        Major activities carried out Zimbabwe with support from IAEA towards industrial applications of radioisotopes are presented. Au198 was used to determine the Residence Time Distribution (RTD) of limestone and clay in the production of clinker at PPC Colleen Bawn factory near Gwanda with the objective of determining hold-up and grinding efficiencies of a ball mill operating in a closed circuit regime. Three experiments were conducted using Au198 radiotracer and highly sensitive NaI(Tl) detectors for radiation measurement. In two experiments, 50 mCi of Au198 was used to tag limestone and clay which were fed into the ball mill at 85 tonnes/hr and 90 tonnes/hr respectively. In the other experiment 100 mCi of the tracer was used to tag limestone with a feedrate of 90 tonnes/hr. The estimated efficiency of the separator of nearly 90% showed that the performance of the separator is satisfactory. It was concluded that the grinding process of raw materials inside the mill was not optimal. In order to determine the amount of gamma radiation released to the environment by coal-fired thermal power generation and environmental gamma radiation levels we have monitored radon concentrations in a coal powered thermal power station (ZPC Bulawayo). Results obtained suggest that there were no high radon concentrations in the coal nor in the fly ash produced by the power plant. Four IAEA Fellows in NDT are currently doing their fieldwork before certification. NDT field work activities using radiography, ultrasound and liquid penetrate techniques were carried out and details of the field work carried out are presented.
        Speaker: Mr Peter Baricholo (National University of Science and Technology, Department of Applied Physic, P. O. AC939, Ascot, Bulawayo, Zimbabwe)
      • 333
        Computed Tomography for Characterizing Industrial Materians
        Computed Tomography (CT) is a non-invasive technique that can provide two-dimensional cross-section image and information on the internal structure of an object including abnormalities and their dimensions using spatial measurements across it. CT has been long used and is well established in the medical and NDT applications but because of emerging technologies and through research and development, it is now carried out for industrial applications. CT is a powerful tool of quality control and has shown a wide range of industrial applications in mechanical, plastic and chemical and ceramics industry. The benefits that the technology offers to industries make gamma-ray CT an interest for research and development endeavours. This paper reports the capability of a first generation gamma ray CT system is characterizing different material in terms of the density distribution along the cross section of each sample. Measurements were taken from samples of wood, industrial steel piper and polyethylene products using a single-source, single-detector system and images were recreated using an image reconstruction software. Reconstructed images show relatively good representations of the actual samples that provide a qualitative density distribution along the object cross section. With further refinement and optimization of measurement parameters and review of reconstruction algorithms, the technique could be a useful tool for inspection and troubleshooting in a variety of industries.
        Speaker: Mr Denis AQUINO (Philippine Nuclear Research Institute, Philippines)
      • 334
        Measurements of Radiotracer Residence Time Distribution Using a Flow Rig in Kenya
        The Kenya Bureau of Standards (KEBS) in partnership with IAEA has set up a Radiotracer Data Analysis measurements facility using a flow rig under Project RAF/0/004 : Cleaner and safer management of industrial. The purpose of the facility is to promote the radiotracer RTD method extensively to industries, in order to optimize processes, solve industrial problems, improve product quality, save energy and reduce pollution. The radiotracer methodology includes the accurate measurement of the residence time distribution (RTD) and its utilization for troubleshooting and diagnosis. The process involve injecting a compatible radiotracer into an appropriate inlet upstream of the flow rig vessel and monitoring its passage through, therefore allowing RTD of fluid to be measured. Sensitive radiation detectors of scintillation nature, are placed at strategic elevations and locations on the flow rig. The scintillation detectors are used because they are relatively small and easy to mount at each position. Each scintillation detector are connected by a cable to a central data logging device that records radiotracer concentration versus time information. The data acquisition system ensures collection, treatment and visualization of the data . When the radiotracer passes each detector a response is registered and recorded. Before the investigation, each detector is assessed and its response normalized so that each detector responds identically to a given unit of radiotracer. The flow rig consists of a tank with four stirrers, a pump flowing the water inside the rig, two flow meters for measuring flow rates in two different branches, several two and three way valves for regulating the flow direction and regime, two injection points, pipes and ion exchange resin column for trapping the radiotracer after a test. Radiotracer used is Tc-99m with relatively low activity for each test. From the results, different flow patterns are then simulated using flow rig. The investigation performed are dead volume measurement, by-pass measurement, determination of residence time distribution (RTD) measurements that include parallel flow measurements, re-circulation experiment, pump mixing and flow rate. The important feature and benefit radiotracer above conventional methods is that measurements can be carried out while a plant is on-line, with no disruption to operating processes. PRESENTER COLLINS OMONDI, KENYA BUREAU OF STANDARDS, RADIOTRACER LABORATORY, cyallar@kebs.org / collinsyallar@yahoo.co.uk
        Speaker: Mr Collins OMONDI (Kenya Bureau of Standards, Kenya)
      • 12:55
        Discussion
    • 13:15
      Lunch break
    • Conclusion Session IAEA Board Room B/M1

      IAEA Board Room B/M1

      Convener: Ms Meera Venkatesh (INTERNATIONAL ATOMIC ENERGY AGENCY)
      • 335
        Closing Remarks on Irradiation Facilities and their Applications
        Speaker: Mr Wilson Calvo (, Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP), Brazil)
      • 336
        Closing Remarks on Radiation Creation of Materials from Fundamentals to Application
        Speaker: Prof. Xavier Coqueret (Universite de Reims Champagne Ardenne)
      • 337
        Closing Remarks on Radiation Technologies for Measurement
        Speaker: Mr Rachad ALAMI (CNESTEN (Centre National de l'Energie des Sciences &amp; des Techniques Nucléaires))
      • 338
        Summary
        Speaker: Mr Suresh Pillai (National Center for Electron Beam Research, United States of America)
      • 339
        Closing of the Conference
        Speaker: Ms MEERA VENKATESH (INTERNATIONAL ATOMIC ENERGY AGENCY)