Conveners
5.5 Large Component Technology I
- Christian LATGE (CEA Cadarache 13108 Saint Paul lez Durance)
- Boris MARGOLIN
Mr
karl vulliez
(CEA, DEN, SDTC, Laboratoire d’Etanchéité, 30207, Bagnols Sur Cèze France.)
27/06/2017, 15:30
Track 5. Fast Reactor Materials (Fuels and Structures) and Technology
ORAL
In the framework of the ASTRID (Advanced Sodium Technological Reactor for Industrial Demonstration) project, the CEA Sealing Laboratory with its partner TECHNETICS (TGF) was involved to propose a new concept of rotating plug seals to replace the commonly used liquid-metal seals. An innovative combination of static, dynamic and inflatable seals in silicone rubber ensuring double...
Dr
Hyungmo Kim
(KAERI)
27/06/2017, 15:50
Track 5. Fast Reactor Materials (Fuels and Structures) and Technology
ORAL
A separate effect test facility called SELFA (Sodium thermal-hydraulic Experiment Loop for Finned-tube sodium-to-Air heat exchanger) using liquid sodium and air as operating fluids has been developed. SELFA is one of the requisite sodium thermal-hydraulic test facilities within the framework of STELLA (Sodium Test Loop for Safety Simulation and Assessment) program, which is indispensible for...
Mr
Sergey Rukhlin
(JSC “Afrikantov OKBM”)
27/06/2017, 16:10
Track 5. Fast Reactor Materials (Fuels and Structures) and Technology
ORAL
To purify primary sodium in the advanced BN-1200 reactor plant, a purification system with cold traps has been used that are located in the reactor vessel (in-built purification system). Such decision has excluded external communications of the auxiliary system with radioactive sodium and respectively a possibility that sodium will outflow to compartments outside the reactor.
The sizes of...
Mr
david plancq
(CEA)
27/06/2017, 16:30
Track 5. Fast Reactor Materials (Fuels and Structures) and Technology
ORAL
Within the framework of the French 600MWe Advanced Sodium Technological Reactor for Industrial Demonstration project (ASTRID), a Gas Power Conversion System (PCS) based on a Brayton cycle is studied. This innovative option has never been implemented in any Sodium Fast Reactor and is mainly justified by safety and acceptance considerations in inherently eliminating the sodium-water and...