Conveners
B13: Radiotracer for managing of natural resources, energy and processes
- Jefferson Vianna Bandeira (Centre for Development of Nuclear Technology (CDTN) - Brazilian Nuclear Energy Commission (CNEN))
- TSec Patrick Brisset
Mr
Thorsten Bruno Otto Jentsch
(Helmholtz-Zentrum Dresden-Rossendorf e.V., Germany)
27/04/2017, 14:15
RADIATION TECHNOLOGIES FOR MEASUREMENT
Oral
Radiotracers are widespread in use for investigation of material transport processes in industry and environment. Often they are used for the measurement of the residence time distribution in continuously operating chemical engineering facilities and reactors. Mostly intrinsic or physical tracers are used for these purposes.
In case of phase transformation processes are in the focus of...
Mr
Jaafar ABDULLAH
(Malaysian Nuclear Agency (Nuclear Malaysia), Malaysia)
27/04/2017, 14:35
RADIATION TECHNOLOGIES FOR MEASUREMENT
Oral
A radiotracer experiment was conducted in an aeration tank of a waste water treatment plant in a chemical plant in Malaysia. Idoine-131 (half-life: 8 days, energy: 360 keV (80%), 640 keV (9%)) as sodium iodide was selected to be used as a radiotracer. About 12.5 GBq (200 mCi) activity of radiotracer was used. The radiotracer was diluted in a volume of about 30 liter and injected into the...
Mr
Rachad Alami
(National Center of Energy Science and Nuclear Techniques, Morocco)
27/04/2017, 14:55
RADIATION TECHNOLOGIES FOR MEASUREMENT
Oral
Non-negligible uncertainty and imprecision in defect detection and defect sizing exist when only using one single Non Destructive Testing (NDT) technique. To increase the reliability and reduce the uncertainty of defect detection and defect sizing, the complementarity and redundancy of radiographic and ultrasonic testing data is exploited. The reliable concept to improve the detection and...
Mr
Ishmael Iddisah Mumuni
(Ghana Atomic Energy Commission, Ghana)
27/04/2017, 15:15
RADIATION TECHNOLOGIES FOR MEASUREMENT
Oral
Crude cost is one of the most important parameters in the operation of an oil company. The choice of crude is very vital in that it determines the profit margins of oil companies, hence the selection of an optimum crude for processing requires a lot of consideration. Neutron backscatter technique is a non-destructive method used for industrial investigation, including determination of...
Ms
Moe Phyu Hlaing
(Department of Atomic Energy, Myanmar)
27/04/2017, 15:35
RADIATION TECHNOLOGIES FOR MEASUREMENT
Oral
Gamma Column scanning technique was utilized to identify of mechanical problems such as missing, collapsed or buckled trays in trayed column of Crude Oil Distillation Unit C at the No. (1) Refinery (Thanlyin), Yangon, Myanmar. It has 52 trays, diameter is 2 meter and height is 43.55 meter. Scanning type of work is Blank Scan and this unit has been shutdown since 2010 due to some processing...