Since 18 of December 2019 conferences.iaea.org uses Nucleus credentials. Visit our help pages for information on how to Register and Sign-in using Nucleus.

22–27 Oct 2018
Mahatma Mandir Conference Centre
Asia/Kolkata timezone
CONFERENCE MATERIAL NOW AVAILABLE!

Development of a High Temperature Black Body Source for ITER ECE Diagnostic

23 Oct 2018, 08:30
4h
Mahatma Mandir Conference Centre

Mahatma Mandir Conference Centre

Gandhinagar (nearest Airport: Ahmedabad), India
Poster FIP - Fusion Engineering, Integration and Power Plant Design P1 Posters

Speaker

Mr RAVINDER KUMAR (ITER-INDIA,INSTITUTE FOR PLASMA RESEARCH)

Description

For ITER Electron Cyclotron Emission (ECE) diagnostic, there is a requirement of high-temperature black body radiation source operating at atmospheric pressure. This source needs to be operated at high temperature (~ 500 0C) having a microwave emissivity > 0.95 in the frequency band 100-500 GHz, and > 0.75 for 500-1000 GHz. Moreover, the radiation surface should have temperature uniformity within ±10 0C. This source will be utilized for characterizing the ITER ECE measuring instruments like Michelson Interferometer and radiometer. For this purpose, a radiation source has been designed and developed. The radiation source consists of a heater and an emissive surface. The emissive surface is made of silicon carbide (SiC), as it has high thermal conductivity, low thermal coefficient of expansion, excellent machinability, good vacuum compatibility and high emissivity in the mm-wave region. The diameter of the emissive surface is 150 mm.The suitable heating element has been used having high resistivity and good oxidation resistance nature. This paper deals with the design, analysis, and characterization of the developed high-temperature black body radiation source in the frequency range 100 to 1000 GHz. The Finite Element Method based software, “COMSOL”, has been used to analyze and optimise the heating coil design to get desired temperature uniformity of the emissive surface. Experimentally, the temperature uniformity is measured by an IR camera and microwave emissivity is measured by the Michelson interferometer.The operating temperature of 500 0C is achieved in the developed source with temperature uniformity within ±10 0C. The short and long-term temperature stability up to ± 2 0C and ± 10 0C respectively has also been achieved. Further, the microwave emissivity of ~0.8 - 0.9 has been observed over wideband 100-1000 GHz. The above measured values are in compliance with ITER requirement.
Country or International Organization India
Paper Number FIP/P1-32

Primary author

Mr RAVINDER KUMAR (ITER-INDIA,INSTITUTE FOR PLASMA RESEARCH)

Co-authors

Dr Hitesh Pandya (ITER-India,IPR) Mr Jignesh Pathak (The M.S University of Baroda) Mrs Suman Danani (ITER-India,IPR) Dr Vinay Kumar (ITER-India,IPR)

Presentation materials