Since 18 of December 2019 conferences.iaea.org uses Nucleus credentials. Visit our help pages for information on how to Register and Sign-in using Nucleus.

The Distortion-Correction of Transmission-Reconstruction of SGS

23 Oct 2014, 10:10
20m
Room M3 (M Building)

Room M3

M Building

Speaker

Zhongqi WANG (China Institute of Atomic Energy)

Description

In this paper, the correction of the linear attenuation coefficient was discussed. The coefficient used for self-absorption correcting of the emission data was reconstructed based on the transmission measurement data.Unlike the basic assumption of reconstruction, the data was measured from cone-like beam instead of the liner beam. The deviation of the coefficient reconstructed has contributed to the deviation of the final result of SGS.The correction technique was developed to reduce the deviation of coefficient by using the Monte Carlo simulation. An iterative process was used to narrow the difference between the coefficient reconstructed and real value by minimizing the difference of the penetration between measurement and simulation. The technique was used to improve the accuracy of final result of SGS and supported by experimental data.
Country or International Organization China

Primary author

Zhongqi WANG (China Institute of Atomic Energy)

Co-authors

Bo Zong (State Nuclear Security Technology Center ,China) Lei Bai (China Institute of Atomic Energy) Qiang Miao (China Institute of Atomic Energy) xiaolin Liu (China Institute of Atomic Energy)

Presentation materials

There are no materials yet.