Conveners
Thursday afternoon - Poster Presentations - Screen5
- Oleg Belyakov (IAEA)
Mohammad Taghi Bahreyni Toossi
(Mashhad University of Medical Sciences)
6/22/17, 3:30 PM
Poster
**Introduction:** Breast cancer treatment techniques include mainly surgery, radiation therapy, chemotherapy, hormone therapy, targeted therapy. Breast cancer patients may experience local-regional recurrence in the chest wall or regional nodes. A combination of surgery followed by radiation therapy significantly reduces the risk of local recurrence. One of the controversial issues of the...
Abdelkader Toutaoui
(Départment de Physique Médicale et de Radioprotection, Hôpital Chahids Mahmoudi, Tizi Ouzou, Algeria)
6/22/17, 3:40 PM
Dosimetry
Poster
The experimental determination of relative output factors presents the greatest challenge, especially for small fields with different detectors yielding measurements that exhibit a high degree of uncertainty and deviate significantly (Westermark et al., 2000). The position and configuration of jaws above tertiary collimators could change dosimetric characteristics in both SRS and IMRT. The X-Y...
Abdelkader Toutaoui
(Départment de Physique Médicale et de Radioprotection, Hôpital Chahids Mahmoudi, Tizi Ouzou, Algeria)
6/22/17, 3:45 PM
Dosimetry
Poster
In this study, the comparison of dosimetric accuracy of Acuros XB and AAA algorithms were investigated for small radiation fields incident on homogeneous and heterogeneous geometries.
Small open fields of Varian iX21 linear accelerator on a 6 MV photon beam 1×1, 2×2, 3×3, 4×4 cm2 were used for this study. The fields were incident on homogeneous phantom and phantom containing lung, air, and...
Yury Kirpichev
(CRT "Oncostop")
6/22/17, 3:50 PM
Dosimetry
Poster
**Introduction.**
Readings of detectors used for reference dosimetry depend on beam energy therefore reference beam calibration requires utilization of beam quality correction factor kQ,Q0. This correction factor was calculated and published in IAEA TRS – 398 for wide range of detectors and beam quality indexes (Q). Beam quality index is used because in clinical practice it’s impossible to...
Sivananthan Sarasanandarajah
(Peter MacCallum Cancer Centre, Australia)
6/22/17, 3:55 PM
Dosimetry
Poster
Introduction
With the increasing concern to measure beam attenuation caused by treatment couch and immobilization devices [1, 2], the objective of this study is to propose a simple and fast method to measure beam attenuation using the current generation of clinically available amorphous silicon electronic portal imaging device (a-Si EPID) without complex procedures to convert the signal to...